This paper provides a new management method (MM) to optimally operate standalone direct current (DC) photovoltaic water pumping system (PVWPS) and synchronize its hydraulic performance to variable daily irradiance. The proposed approach well considers the issues from PV generator and a positive displacement pump mismatching to deserve a hydraulic network. Accordingly, Management Method uses small pumps mounted in parallel scheme to displace the hydraulic power point (HPP) in order to satisfy the mal adequacy between supply and load. Based on experimental Study; this approach showed a yielded standalone system, possibility of running pumping system using only photovoltaic supply (Without use of capacitance), and possibility to design more economical PV systems as the maximum peak power demand for each month can be satisfied using small power pumps in parallel and adjusting their switch with accordance to varying daily irradiance. Moreover, an analytical model was developed with reference to the obtained experimental results. This model based on a daily occurring irradiance as inputs in order to predict optimal performance outputs. It can be considered as a decision tool to track power point resulting from optimal electrical and hydraulic performances of the pumping system according to changes of the daily irradiance.