The sensitivity of DNBR(Departure from Nucleate Boiling Ratio) values to approaches of subchannel control volume selection has been investigated for the TS01 and TS03 out of HIPER17 CHF(Critical Heat Flux) tests. In general, the coolant-centered subchannel method is applied to subchanel analyses for fuel bundle. When it comes to predicting for CHF of high quality region, however, the rod-centered subchannel method was better over high quality region. As a result, the rod-centered subchannel method were more suitable at a conservative point of view than the coolant-centered subchannel method comparing major properties. Also, it was confirmed that the radial subchannel locations at the minimum DNBR were similar when comparing both analysis results by two kind of methods.