Rooftop solar water heaters face a mismatch through the year. They collect the least heat in winter, when households need it most, and the most in summer, when the surplus overheats the system. This paper examines a collector, proposed by Chen et al., that tackles both problems passively. Rows of horizontal evacuated tubes sit on a 20° roof, each backed by a shallow, one-sided reflector shaped by the edge-ray method. When the sun’s projected altitude is below 50°, as it is in winter, the reflector concentrates light onto the tube. When the sun is higher, the reflected light misses the tube and returns to the sky. The 6 cm deep module showed a peak optical efficiency of 0.76, falling to about 0.35 at high sun. Outdoor tests gave daily efficiencies of 0.28–0.42, and the thermal model matched them with R2 = 0.985. Simulations for 371 Chinese cities reported 100–125% more winter heat than a flat-plate collector in cold northern regions and 4–26% less in summer. We reconstructed the reflector profile from the published equations and ray-traced it ourselves. Our curve, after a single loss factor of 0.83, reproduces both reported efficiency levels. A clear-sky seasonal analysis then shows that the reflectors raise winter beam capture by 1.5–1.7 times over bare tubes and leave summer capture unchanged. On beam optics alone, however, the module does not out-collect a flat plate in winter, so most of its winter advantage comes from the low heat loss of the evacuated tubes. We also note inconsistencies in the reported payback and seasonal figures.
Keywords: 
;  ;  ;  ;  ;  ;  

I. Introduction

Buildings use about 30% of the world’s final energy, and much of that goes to space heating and hot water [1]. Solar thermal collectors are a cheap, mature way to supply this heat, and small rooftop systems that serve a single home avoid the large land area of district schemes [2], [3]. Their main weakness is timing. In winter the days are short, the sun is low, and a gently sloped roof faces it poorly, just when heat demand peaks. In summer the opposite happens. The system collects more heat than it can use, and the excess drives the collector into stagnation, which degrades fluids, seals, and coatings [4], [5].
Large plants handle this with seasonal storage [6], but that is not practical for one house. Several fixes have been tried at the collector level. Concentrators raise winter output, but tracking types such as micro-parabolic troughs and linear Fresnel units add cost and moving parts [7], [8]. Stationary compound parabolic concentrators (CPCs) need no tracking when the concentration ratio is below about 3 [9], [10], [11]. To limit overheating, others have added venting ducts [12], [13], thermochromic absorber coatings [14], or temperature-switching covers [15], all of which add cost or complexity. An earlier asymmetric CPC by Chen and Yang used shading between tube rows to cut summer output, but it only worked at steep mounting angles [16].
Chen et al. proposed a design that does both jobs with fixed optics on an ordinary low-slope roof [17]. The key observation is that, at mid-latitudes, the sun’s altitude in winter and in summer falls in two separate ranges. A reflector that accepts light only below a chosen cut-off angle will therefore work hard in winter and switch itself off in summer. This paper reviews the concept and results, then tests the optical claim independently. Our contributions are:
  • A reconstruction of the reflector profile from the published design equations, with a check that it satisfies the edge-ray condition exactly.
  • An independent two-dimensional ray trace of the tube array, compared with the reported optical efficiency.
  • A clear-sky seasonal analysis that separates the effect of the reflectors from that of the vacuum insulation, and a check of the economic and seasonal figures.

II. Design Concept

A. Season as an Optical Switch

For a collector whose tubes run east–west, what matters is the projected solar altitude θp, the sun’s elevation seen in the north–south vertical plane [18]. In Beijing (39.9° N), θp stays between about 16° and 54° from November to March, but lies between about 60° and 94° from June to August [17]. Figure 2 shows how the noon value varies with latitude. A cut-off at θc = 50° sits in the gap between the seasons. North of about 40° N, the noon sun stays below the cut-off for roughly half the year. Farther south, the concentrating window shrinks to the core winter months.

B. Reflector Profile

Each tube has a single reflector on its sunward lower side. The profile is built from the involute of the absorber. A point T on the reflector lies a tangent distance ρ from the tangent point P on the absorber of radius Ri, at polar angle ω:
x = R i   sin   ω − ρ   cos   ω ,     y = − R i   cos   ω − ρ   sin   ω
The edge-ray rule requires every ray arriving at θc to be reflected tangent to the absorber. This fixes the local slope, and it leads to
d ρ d ω = R i + ρ   tan ω − θ c 2
which integrates to
ρ ( ω ) = R i ( ω − θ c + sin ( ω − θ c ) ) + 2 ρ o 1 + cos ( ω − θ c )
Here ρo = (Ro2 − Ri2)1/2 leaves room for the outer glass tube [17]. The prototype values are listed in Table I. We evaluated (1)–(3) numerically. The resulting curve matches the slope required by the edge-ray rule to within 0.01° along its whole length. Every ray arriving at 50° leaves it tangent to the absorber, so the published equations are self-consistent.
Table I. Main design parameters of the module [17].
Parameter Value
Absorber/glass diameter 47 mm/58 mm
Acceptance limit θc 50°
End polar angle ωe 133°
Tube pitch dc 110 mm
Roof slope β 20°
Tubes, length 10, 1.7 m
Depth, aperture 6.0 cm, 1.87 m2
Because the reflector sits on one side only, the module is just 6 cm deep and fits flush on a roof, which also helps it resist wind loads. Each tube is a standard double-glass evacuated tube with a selective coating, an aluminum fin, and a U-pipe carrying the water. The reflectors are thin aluminum strips covered with a high-reflectance film and held in 3D-printed side brackets [17].
Figure 1. Ray paths through the reconstructed array at projected sun angles of (a) 35°, where light is concentrated onto the absorber, and (b) 70°, where reflected light escapes. Red: rays reaching an absorber; orange: rays lost (computed in this work from (1)–(3)).
Figure 1. Ray paths through the reconstructed array at projected sun angles of (a) 35°, where light is concentrated onto the absorber, and (b) 70°, where reflected light escapes. Red: rays reaching an absorber; orange: rays lost (computed in this work from (1)–(3)).
Preprints 246028 g001
Figure 2. Noon solar altitude through the year at four latitudes, relative to the 50° acceptance limit (computed in this work).
Figure 2. Noon solar altitude through the year at four latitudes, relative to the 50° acceptance limit (computed in this work).
Preprints 246028 g002

C. A Simple Design Rule

For tubes running east–west, the projected altitude at an equinox stays at exactly 90° − φ all day, where φ is the latitude. Figure 5 shows this for Beijing. Below the equinox line, the sun stays inside the acceptance band for the whole winter day. Above it, the summer sun stays outside the band from sunrise to sunset. This gives a simple rule. Choosing θc = 90° − φ makes the collector switch modes at the equinoxes. The chosen 50° is therefore the equinox setting for Beijing (90° − 39.9° = 50.1°). At other latitudes, a fixed 50° moves the switch dates, as Table III shows. In Guangzhou, the reflector works for only about 89 days around midwinter. In Harbin it works for about 212 days, well into April and September. To switch at the equinoxes in the south, θc would have to be about 67°.
Figure 5. Projected solar altitude over the day in Beijing (39.9° N) at the solstices and equinoxes. The equinox curve is flat at 90° − φ ≈ 50° (computed in this work).
Figure 5. Projected solar altitude over the day in Beijing (39.9° N) at the solstices and equinoxes. The equinox curve is flat at 90° − φ ≈ 50° (computed in this work).
Preprints 246028 g003
Table III. Concentrating window at noon for θc = 50° (computed in this work).
City Latitude Concentrating period Days per year
Guangzhou 23.1° N Nov 7 – Feb 4 89
Chongqing 29.6° N Oct 18 – Feb 24 129
Shanghai 31.2° N Oct 13 – Feb 28 138
Beijing 39.9° N Sep 21 – Mar 22 182
Harbin 45.8° N Sep 6 – Apr 6 212

III. Optical and Thermal Model

The absorbed beam power is Gb = DNI·cos Ψ·ηb(θp)·Ap. Here Ψ is the sun’s deviation from the north–south plane, ηb is the optical efficiency, and Ap is the aperture area. Diffuse and ground-reflected light are added with an isotropic sky model that averages ηb over all angles [18]. In the original study, ηb(θp) was found by ray tracing 5000 parallel rays in TracePro at 1° steps [17]. It rose to 0.76 just below 50°, dropped quickly to about 0.35 above it, and fell further beyond 140° as neighboring tubes shaded each other.
The useful heat follows the usual collector equation,
Q u = F ′ [ G abs − U L A abs ( T f − T a ) ]
with the efficiency factor F′ and loss coefficient UL built from a resistance network. The network includes glass-to-air convection, radiation across the vacuum gap, an edge-loss term, conduction through the fin, and Gnielinski convection inside the U-pipe [19], [20]. Because of the vacuum, UL stays near 1.1–1.3 W/m2K over the operating range, which is several times lower than for a glazed flat plate [17].

IV. Experimental Results

A 10-tube prototype was tested outdoors on a mock 20° roof facing due south from April 26 to 30, 2023, at a flow rate of about 2.2 L/min [17]. Pyranometers on horizontal and 20° planes were used to split the radiation into direct and diffuse parts. Table II summarizes the daily results. On the sunny day, irradiance on the 20° plane reached about 1260 W/m2 at noon and the heat output peaked near 750 W. The model followed the measured heat output closely, with an RMSE of 20.6 W and R2 = 0.985 over the five days. Note that in late April the noon sun is above 50° at any latitude in China south of about 54° N (Figure 2). The test therefore mainly exercised the de-concentrating mode near midday.
Table II. Daily outdoor test results [17].
Day type Solar (kWh/m2) Heat (kWh/m2) Efficiency
Partly cloudy 5.51 1.98 0.36
Cloudy 1.85 0.52 0.28
Sunny 6.72 2.82 0.42
In standardized efficiency curves, the module in winter conditions matched a one-sun CPC collector and stayed above 0.5 at a fluid-to-air temperature difference of 70 K [9]. In summer conditions it fell to 0.20–0.35 [17]. For a typical year in Beijing, it gathered 251 kWh/m2 from November to March against 85 kWh/m2 for a flat plate. From June to August it gathered 168 against 180 kWh/m2.

V. Independent Optical Check

A. Ray Trace of the Reconstructed Array

We placed 30 tubes at 110 mm pitch along a 20° slope, attached the reconstructed reflector to each, and traced parallel rays in two dimensions for θp = 2°–178°. Up to five reflections were allowed, the back faces of the reflectors were treated as opaque, and the glass was assumed clear. Efficiency was taken as the share of rays reaching the absorbers of the central tubes, relative to the flux through one pitch width. This is the same normalization as the cos Ψ form above.
Figure 3. Geometric optical efficiency of the reconstructed module from our ray trace, and the same curve scaled by 0.83 for glass, coating, and mirror losses, with the values reported in [17].
Figure 3. Geometric optical efficiency of the reconstructed module from our ray trace, and the same curve scaled by 0.83 for glass, coating, and mirror losses, with the values reported in [17].
Preprints 246028 g004
The geometric result (Figure 3) has the same shape as the published curve. For a bare tube array it gives 0.43, the ratio of tube diameter to pitch (47/110). It climbs steadily to 0.90 at 46° and collapses back to 0.43 just above 50°. It shows the same small bump near 130° and the same shading loss beyond 140°. A single loss factor of 0.83, which is a reasonable product of glass transmittance, absorptance, and mirror reflectance, brings the peak to 0.75 and the plateau to 0.35. These values almost match the reported 0.76 and 0.35. This gives good independent support for the optical part of the original work.

B. Where Does the Winter Gain Come from?

Using our curve, we computed clear-sky beam energy (Meinel model, beam only [18]) absorbed per unit aperture over November–March and June–August. We compared three cases: the module, the same tubes without reflectors, and a flat plate on the same roof with an optical efficiency of 0.85. Figure 4 shows the results. The reflectors raise winter beam capture by 1.5–1.7 times over bare tubes at every latitude and add nothing in summer, so the seasonal switch works as intended. As a result, the module’s winter-to-summer capture ratio is 1.3–2.2, while a flat plate’s is 0.6–1.4.
Figure 4. Clear-sky beam-energy ratios by latitude: reflector gain in winter, and winter (Nov–Mar) to summer (Jun–Aug) ratios for the module and a flat plate (computed in this work).
Figure 4. Clear-sky beam-energy ratios by latitude: reflector gain in winter, and winter (Nov–Mar) to summer (Jun–Aug) ratios for the module and a flat plate (computed in this work).
Preprints 246028 g005
The comparison with the flat plate shows something the original paper does not separate out. Per unit aperture, the module’s peak optical efficiency (0.76) is below a flat plate’s, and its plateau is less than half. Its clear-sky winter beam capture therefore comes out 9–26% below the flat plate’s, not above it. The large winter thermal gains reported for cold regions, of 100–125%, must therefore come mainly from the vacuum insulation. At 60 °C and sub-zero air, a flat plate with UL of perhaps 4–6 W/m2K loses most of its weak winter input, while the evacuated tube does not. This fits the authors’ finding that the winter gain rises with latitude and falls with mean air temperature [17], because the optical gain in Figure 4 barely changes with latitude. The reflectors’ real job is to concentrate the winter sun and reject the summer sun. The tubes are what make winter collection pay off.

VI. Consistency of Reported Figures

Seasonal effect. The national map gives winter gains of at most 100–125%, with the highest summer cuts of 24–30% at 37.5–42.5° N. The Beijing year, however, implies a winter gain of (251 − 85)/85 = 195% and a summer cut of only (180 − 168)/180 = 6.7%. The abstract also gives the summer range as 4–26%. These figures may rest on different assumptions, such as fluid temperature or weather data, but as written they do not match.
Payback. The system of six modules was reported to deliver 5205 kWh/yr. At the stated gas price of 0.13 $/kWh, that is worth about 677 $/yr, not the 346.7 $/yr used [17]. With the reported capital cost of 1397.6 $ and running cost of 139.8 $/yr, the payback would then be 1397.6/(677 − 140) ≈ 2.6 years rather than 6.8. The 346.7 $ figure corresponds to about 0.067 $/kWh. If a lower effective price was intended, for example to allow for boiler efficiency or a different tariff, it should be stated. The levelized cost of heat (0.049 $/kWh versus 0.047 $/kWh for a flat plate) does not depend on this price.
Table IV. Economic figures: reported and rechecked.
Item Reported [17] Recheck (this work)
Collector cost (module/flat) 88.7/50.4 $/m2 —
System capital cost 1397.6 $ —
Annual operating cost 139.8 $ 10% of capital
Annual heat output 5205 kWh —
Annual saving at 0.13 $/kWh 346.7 $ 676.7 $
Payback, module system 6.8 yr ≈2.6 yr
Levelized cost of heat 0.049 $/kWh unchanged

VII. Discussion

The design is attractive because the seasonal switch costs nothing to run and uses cheap materials, and because the shallow, one-sided reflector suits ordinary low-slope roofs. The optics behave as claimed. Three caveats are worth noting. First, south of about 30° N the concentrating window is short (Figure 2), so the benefit there is limited. Second, the outdoor test was run in spring, outside the concentrating season, so a winter test would be the strongest proof of the concept. Third, diffuse light, which dominates in cloudy regions, is handled by an isotropic average and is not switched by season, which may explain why the summer reduction is smaller in humid areas.

VIII. Conclusion

An asymmetric non-imaging reflector behind each evacuated tube gives a rooftop collector a passive seasonal switch. Light is concentrated when the sun is below 50° and rejected above it. Our reconstruction of the published profile is exact, and an independent ray trace, with a single realistic loss factor, reproduces the reported optical efficiencies of 0.76 and 0.35. The reflectors raise winter beam capture by 1.5–1.7 times over bare tubes while leaving summer capture unchanged. Much of the reported 100–125% winter advantage over flat plates, however, comes from the low heat loss of the vacuum tubes rather than from extra optical collection. With corrected seasonal and payback figures (a payback of about 2.6 years at the stated gas price), the concept looks practical for cold, sunny regions north of about 35° N.

References

  1. Wang, Y.; Guo, J.; Yue, Q.; Chen, W.-Q.; Du, T.; Wang, H. Total CO2 emissions associated with buildings in 266 Chinese cities: Characteristics and influencing factors. Resour. Conserv. Recycl. 2023, 188, 106692. [Google Scholar] [CrossRef]
  2. REN21. Renewables 2022 Global Status Report; Paris, France, 2022. [Google Scholar]
  3. Patel, D.; Sheth, K. Penrose-tiled Rhombus Solar Panels: A Novel Approach for Optimizing Rooftop Utilization and Aesthetic Integration [Preprint]; TechRxiv, 2026. [Google Scholar] [CrossRef] [PubMed]
  4. Harrison, S.; Cruickshank, C.A. A review of strategies for the control of high temperature stagnation in solar collectors and systems. Energy Procedia 2012, 30, 793–804. [Google Scholar] [CrossRef]
  5. Çimen, M.; Colakoglu, M.; Güngör, A. Overheating limitation of thermosiphon solar collectors by controlling heat pipe fluid in all glass evacuated tubes. Sol. Energy 2021, 230, 515–527. [Google Scholar] [CrossRef]
  6. Tosatto, A.; Ochs, F. Performance comparison of large-scale thermal energy storage and hydrogen as seasonal storage for achieving energy autarky in residential districts with different renovation levels. J. Energy Storage 2024, 98, 113009. [Google Scholar] [CrossRef]
  7. Yang, M.; Moghimi, M.A.; Zhu, Y.; Qiao, R.; Wang, Y.; Taylor, R.A. Optical and thermal performance analysis of a micro parabolic trough collector for building integration. Appl. Energy 2020, 260, 114234. [Google Scholar] [CrossRef]
  8. Sultana, T.; Morrison, G.L.; Rosengarten, G. Thermal performance of a novel rooftop solar micro-concentrating collector. Sol. Energy 2012, 86, 1992–2000. [Google Scholar] [CrossRef]
  9. Osório, T.; Horta, P.; Marchã, J.; Collares-Pereira, M. One-sun CPC-type solar collectors with evacuated tubular receivers. Renew. Energy 2019, 134, 247–257. [Google Scholar] [CrossRef]
  10. Adsten, M.; Helgesson, A.; Karlsson, B. Evaluation of CPC-collector designs for stand-alone, roof- or wall installation. Sol. Energy 2005, 79, 638–647. [Google Scholar] [CrossRef]
  11. Deng, C.; Chen, F. Preliminary investigation on photo-thermal performance of a novel embedded building integrated solar evacuated tube collector with compound parabolic concentrator. Energy 2020, 202, 117706. [Google Scholar] [CrossRef]
  12. Kessentini, H.; Castro, J.; Capdevila, R.; Oliva, A. Development of flat plate collector with plastic transparent insulation and low-cost overheating protection system. Appl. Energy 2014, 133, 206–223. [Google Scholar] [CrossRef]
  13. Hussain, S.; Harrison, S.J. Experimental and numerical investigations of passive air cooling of a residential flat-plate solar collector under stagnation conditions. Sol. Energy 2015, 122, 1023–1036. [Google Scholar] [CrossRef]
  14. Föste, S.; Pazidis, A.; Reineke-Koch, R.; Hafner, B.; Mercs, D.; Delord, C. Flat plate collectors with thermochromic absorber coatings to reduce loads during stagnation. Energy Procedia 2016, 91, 42–48. [Google Scholar] [CrossRef]
  15. Muehling, O.; et al. Solar collector cover with temperature-controlled solar light transmittance. Energy Procedia 2014, 48, 163–171. [Google Scholar] [CrossRef]
  16. Chen, X.; Yang, X. Solar collector with asymmetric compound parabolic concentrator for winter energy harvesting and summer overheating reduction: Concept and prototype device. Renew. Energy 2021. [Google Scholar] [CrossRef]
  17. Chen, X.; Zhu, W.; Si, P.; Yang, X.; Feng, C. Innovative solar collector on rooftop: Asymmetrical non-imaging optical design to reconcile seasonal energy mismatch. 2026. Available online: https://ssrn.com/abstract=6623468.
  18. Duffie, J.A.; Beckman, W.A. Solar Engineering of Thermal Processes, 4th ed.; Wiley: Hoboken, NJ, USA, 2013. [Google Scholar]
  19. Ma, L.; Lu, Z.; Zhang, J.; Liang, R. Thermal performance analysis of the glass evacuated tube solar collector with U-tube. Build. Environ. 2010, 45, 1959–1967. [Google Scholar] [CrossRef]
  20. Sheth, K.; Patel, D.; Shekhara, K.; Sajeev, S.K. From liability screening to design input: Structuring Phase I environmental site assessments for photovoltaic siting on post-extractive land. In 2026 11th International Conference on Communication and Electronics Systems (ICCES); IEEE, 2026; pp. 690–694. [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.