Preprint
Review

This version is not peer-reviewed.

Formation Mechanisms and Predictive Methods for Flashing Jets from Pressurized Hot Water Leaks

Submitted:

24 November 2026

Posted:

25 November 2026

You are already at the latest version

Abstract
When pressurized hot water leaks through an opening, depressurization and vaporization within the passage influence jet breakup and downstream two-phase transport. This review compares experiments and predictive models for hot-water and steam–water releases through orifices, short passages, slits, and cracks. Short-tube and crack experiments show that mass flux depends on the upstream thermodynamic state, flow resistance, and the time available for vaporization. Deformation under pressure can also alter the effective flow path in cracks. Near-field measure-ments link the vapor content at the exit to jet spreading and breakup. Downstream studies dis-tinguish droplets formed by liquid breakup from those formed by condensation during mixing. Critical-flow models have been evaluated extensively against discharge-rate data, while models that resolve finite-rate phase change and separate phase motion have also been assessed against local measurements of pressure, phase fractions, and bubble size. A key challenge is to measure the phase distribution and velocities at the exit of real cracks during hot-water discharge and re-late them to primary droplet formation, leak-detection signals, and jet impingement loads.
Keywords: 
;  ;  ;  ;  ;  ;  

1. Introduction

When pressurized hot water leaks through an orifice, slit, or crack, rapid depressurization, phase change, and flow acceleration interact and can produce vapor-liquid flow with substantial thermodynamic nonequilibrium. After leaving the passage, liquid that remains superheated relative to the local pressure may continue to flash. Jet expansion, interfacial instability, and liquid breakup then produce a two-phase jet containing steam, continuous or fragmented liquid, and atomized droplets. The associated transfer of mass, momentum, and energy changes the local temperature and humidity and generates jet reaction forces and impact loads on structures. Pressurized hot-water leakage therefore spans several coupled scales, from discharge within the passage and the establishment of the exit phase state to near-field evolution and downstream engineering effects.
Critical-flow studies have mainly addressed the release rate, expressed as either mass flow rate or mass flux [1,2], whereas jet-impingement studies have focused on the mechanical loads exerted by external flow on structural surfaces [3]. Predicting the external jet and its engineering effects generally requires more than the total mass flow rate. The external flow also depends on the thermodynamic and hydrodynamic state at the passage exit, including the vapor-liquid partition, phase velocities, pressure, temperatures, and characteristic interfacial length scales. Critical-flow models quantify the amount released; external-jet models additionally require the state in which the fluid enters the surroundings. Linking the internal flow to the external two-phase jet thus requires a set of exit source variables whose definitions are consistent, or can be converted consistently, across experiments, theoretical models, and numerical calculations.
Several largely separate areas of research contribute to this problem. Studies of flash boiling and flash atomization address nucleation, bubble growth, interfacial instability, and liquid breakup [4,5], while bibliometric work traces changes in the research topics [6]. Studies of two-phase critical flow and flashing inception examine how metastability, interphase slip, and finite-rate phase change affect the mass flow rate and extent of vaporization [1,2,7,8]. Reviews of flashing simulations and CFD for nuclear safety compare phase-change models, interphase interaction closures, and descriptions of interfacial length scales [9,10,11]. Research on releases of hazardous liquefied substances focuses on the relation between initial atomization and subsequent two-phase dispersion, evaporation, and rainout [12,13], while work on high-energy piping addresses jet reaction and impingement loads [3]. These studies constrain different parts of the discharge, interface evolution, and engineering response. Their source variables, phase definitions, and validation measures differ, however, so a result at one scale often cannot be used directly as an input at the next. A common description of how state information passes between scales remains less developed than the descriptions of individual processes.
Determining the exit state is also experimentally difficult. Phase change within the opening and expansion and breakup outside it often occur over similar spatial and temporal scales. In the dense two-phase region near the outlet, transient vaporization during rapid depressurization interacts with bubble growth and interface breakup, making the vapor-liquid partition and interfacial structure difficult to determine with a single diagnostic. Existing reviews discuss flashing jets and the compression waves or shocks that may accompany them [14], as well as evaporation-wave propagation in stationary and flowing superheated liquids [15]. Work on thermal management distinguishes phase-change-atomization coupling near the outlet from heat and mass transfer in the fully developed region [16]. Transparent-nozzle experiments, high-speed imaging, and nonintrusive diagnostics developed for fuel injection provide useful methods for linking internal bubble evolution to external breakup [17,18]. Fuels and refrigerants nevertheless differ from hot water in their thermophysical properties, surface tension, latent heat, and response to depressurization. Applying their empirical correlations or transition criteria to hot-water leaks requires checking similarity in fluid properties, geometric scales, and governing parameters.
Leakage through engineering cracks adds further complexity. Compared with a regular orifice or nozzle, a crack may have a load-dependent opening, a large aspect ratio, successive contractions and expansions, and irregular walls. The same nominal opening area therefore need not produce the same pressure drop, extent of phase change, or exit state. Studies of microcrack leakage have already related crack morphology and flow resistance to critical flow and thermodynamic nonequilibrium [19]. Assessing whether an orifice or short passage represents a real crack requires comparison of the exit vapor-liquid partition, velocity slip, and interfacial length scales, as well as the total leakage rate. The downstream consequences of these differences for droplet formation, heat and mass transfer, and load transmission must also be considered.
This critical review examines pressurized hot-water leakage as a connected sequence of internal discharge, exit-state formation, external two-phase flow, and engineering response. The exit state provides the connection between these scales. The main scope is the release of pressurized hot water or steam-water mixtures through orifices, short passages, slits, and cracks into a gas environment at lower pressure. The literature emphasizes water experiments, numerical simulations, and thermodynamic nonequilibrium models published over the past decade, together with representative earlier work on two-phase critical flow, flashing, and flash boiling. Vacuum water sprays, steam-air jets, and other pressure-release processes are included where they clarify a specific subprocess. Studies of fuels, refrigerants, and hazardous liquefied substances are used primarily to compare diagnostic methods, interphase exchange models, and the conditions for transferring models between fluids. Such comparisons are restricted to cases with comparable physical mechanisms or governing parameters because fluid properties and boundary conditions differ.
Studies are compared according to fluid properties, upstream thermodynamic states, ambient conditions, passage geometry, and measured variables. For quantitative results, the pressure reference, geometric scale, measurement location, and statistical definition are retained wherever possible. Direct measurements are distinguished from values inferred from experimental data, numerical predictions, and proposed physical explanations. Where several numerical studies use the same experimental dataset, the original data source is used to assess the independence of the validation evidence. Quantitative conclusions for specific operating conditions are drawn preferentially from original studies; reviews provide context and summarize findings shared across studies. Differences in boundary conditions, diagnostics, and evaluation measures often prevent direct pooling of results. The comparisons therefore focus on consistency of trends, variable definitions, ranges of applicability, and sources of uncertainty.
The review addresses three related questions: how well experiments and models determine the exit state for specified upstream, passage, and ambient conditions; whether exit variables, measurements, and predictions are comparable across studies; and under what conditions these source descriptions support reliable predictions of the external two-phase jet and engineering response. Section 2 describes the physical processes and defines the variables used to characterize the exit state. Section 3 reviews experiments on internal discharge, near-field flashing and dispersion, and downstream two-phase evolution, distinguishing quasi-steady boundary conditions from local transient observations. Section 4 compares the capabilities and validation ranges of critical-flow, nonequilibrium phase-change, and two-phase CFD models for different prediction tasks. Section 5 considers how source and flow-field information relates to temperature and humidity, jet reaction forces, target loads, and structural dynamics. Section 6 identifies research needs arising from uncertainties in the existing experiments and models, and Section 7 summarizes the findings and their ranges of applicability.

2. Physical Understanding of Flashing and Parameter Definitions

In their review of subcooled critical flow, Kim et al. [1] identify metastability after depressurization and delayed vaporization as central to explaining discharge rates. Yin et al. [7] compare nucleation and flashing-inception criteria, while Liao and Lucas [9] review numerical descriptions of two-phase flow after bubbles have formed. These studies describe flashing as a sequence involving depressurization-induced superheating, nucleation, and bubble growth, but emphasize different outputs: flow rate, inception location, and phase distribution, respectively. Differences in terminology therefore reflect differences in the quantities studied and stages observed, as well as naming conventions.

2.1. From Flashing Inception to Breakup and Cooling

The subcooled critical-flow data reviewed by Kim et al. [1] and the studies of Henry and Fauske [29] and Chun et al. [32] characterize the inlet state by the upstream subcooling, Tsat(p0) − T0. By contrast, the nucleation review by Yin et al. [7] and the injection experiments of Kitamura et al. [20] consider superheat relative to the local pressure, T − Tsat(p). Here, p0 and T0 are the inlet pressure and temperature, and Tsat is the saturation temperature. The first definition describes the liquid before it enters the passage; the second describes the driving force for vaporization after depressurization. Inlet subcooling and downstream superheating can therefore occur within the same discharge. Kim et al. and Yin et al. also relate vaporization delay to wall nucleation, gas content, and the depressurization history. The evidence considered below primarily concerns subcritical liquids; near-critical and supercritical releases are discussed in terms of their respective thermodynamic paths.
Studies referring to the completion of flashing use different endpoints. Yin et al. [7] discuss the conditions for the first formation of vapor. The classifications of complete breakup or full expansion used by Kitamura et al. [20], Busov [41], and Reshetnikov et al. [42] concern the liquid core and macroscopic jet shape. Mutair and Ikegami [23] instead describe subsequent cooling in terms of droplet temperatures approaching equilibrium. Moshkovich et al. [21] include the initial temperature and depressurization rate in a criterion for homogeneous flash atomization, while Sher et al. [4] relate bubble growth to breakup. The capillary and aerodynamic instabilities reviewed by Eggers and Villermaux [22] explain the role of mechanical breakup. Kitamura et al. found that the superheat required for complete breakup depended on velocity and orifice diameter, showing that the macroscopic breakup threshold contains both thermal and dynamic effects.
Mutair and Ikegami [23] studied superheated water droplets formed by flashing jets, and Hu et al. [24] investigated sessile droplets under depressurization experimentally and numerically. Both considered heat transfer and vaporization within droplets. Studies of steam-air jets by Lim et al. [25] and Burluka [26] show that entrainment and mixing can also generate new droplets through condensation. These findings explain downstream droplet evolution through both the sensible energy stored in the liquid and mixing with the surroundings. Ambient total pressure affects expansion and saturation conditions, whereas the water-vapor partial pressure relative to the equilibrium vapor pressure at the droplet surface determines the direction of net evaporation or condensation. Jet cooling may therefore continue after intense flashing has subsided, and an observed droplet population may contain both breakup and condensation droplets. Figure 1 relates these processes to the locations at which they are observed.

2.2. Phase-Fraction Definitions and Exit-State Descriptions

Isbin et al. [27], Moody [28], Henry and Fauske [29], and Chun et al. [32] characterize discharge by the mass flow rate m ˙ or mass flux G = m ˙ / A , where A is the flow area. Their phase fractions, however, do not all come from independent phase-resolved measurements. Isbin et al. inferred the tabulated xth from total energy under assumptions of homogeneous flow and thermodynamic equilibrium. They explicitly noted that the actual exit quality could only be determined with information on the kinetic energy of each phase. Their dataset therefore combines measured flow rates with model-assisted thermodynamic qualities, which are obtained in different ways.
Moody [28] defines quality as the vapor mass flow rate divided by the total mass flow rate and treats the vapor-to-liquid slip ratio as an independent variable. The homogeneous relaxation models discussed by Liao and Lucas [9] refer to vapor mass fraction as vapor quality, whereas Pinhasi et al. [30] define void fraction as vapor volume fraction. Here, these quantities are denoted by the flow quality xf, vapor mass fraction within a control volume xh (inventory quality), and void fraction α, respectively. For one-dimensional cocurrent flow with uniform representative states for each phase, the standard definitions give
x f = α ρ g u g α ρ g u g + ( 1 − α ) ρ l u l ;    x h = α ρ g α ρ g + ( 1 − α ) ρ l
where ρg and ρl are the vapor and liquid densities, and ug and ul are their respective velocities. Slip, as allowed in Moody’s model, causes xf to differ from xh, while the density difference distinguishes both from α. The relation xf = xh holds only for equal phase velocities evaluated at consistent representative states. Thus, the vapor share of the mass flow rate and the local void fraction cannot be interchanged simply because both describe phase content: cross-sectional flux averages, volume averages, and probe samples have different weighting.
Witlox and Bowen [12] and Polanco et al. [13] discuss descriptions of the initial jet state in their reviews of two-phase releases and dispersion, while Pinhasi et al. [30] relate exit conditions to source terms for external transport. The exit in these studies can be the geometric opening or a computational inlet selected after partial expansion of the jet. Section A in Figure 2 is the geometric exit, where pressure may exceed ambient pressure. Section B is selected from the downstream pressure field so that its pressure is close to ambient. The extent of acceleration, vaporization, and breakup at that section depends on the operating conditions. These two choices assign different parts of the release process to the downstream model.
Witlox and Bowen [12] and Polanco et al. [13] relate initial atomization to subsequent dispersion and rainout. Pinhasi et al. [30] identify flow rate, exit velocity, and void fraction as inputs to dispersion calculations, while the CFD study of nonaqueous liquefied substances by Calay and Holdø [31] demonstrates the influence of the initial droplet size. These studies provide complementary descriptions of the source: the release rate specifies the total mass entering the external flow per unit time, while the phase states and droplet sizes govern how it is transported. Correlations between droplet size, velocity, and direction also affect the spatial distribution of mass and momentum during rainout and interception by a finite target.
Exit descriptions also differ in the fluxes they constrain. Moody [28] combines continuity and energy equations to determine the maximum two-phase flow rate. Gorelik et al. [132] measured water flow rate and nozzle reaction together to infer a mass-averaged exit velocity, while the source models reviewed by Pinhasi et al. [30] connect release to external transport. To compare these outputs, Eq. (2) gives mass, normal momentum, and total-energy transport rates using standard control-volume definitions. A common static pressure and uniform representative phase velocities are assumed, with flow predominantly normal to the section. Viscous stresses, conductive heat flux, and potential energy at the section are neglected:
m ˙ = ∑ k m ˙ k Π n = ∑ k m ˙ k u k , n + ( p e − p a ) A e E ˙ = ∑ k m ˙ k h k + u k · u k 2
Here, k = l,g denotes the liquid and vapor phases, respectively; hk, m ˙ k , and uk are specific enthalpy, mass flow rate, and velocity, and uk,n is the normal velocity component. The selected cross-sectional area is Ae, and pe and pa are the static pressures at that section and in the surroundings. Πn combines normal momentum transport and pressure thrust, while E ˙ combines enthalpy and kinetic-energy transport. Nonuniform sections require area-integral forms. The jet reaction force and target impingement force are each determined from the complete momentum balance for the corresponding control volume.
Equation (2) identifies the physical quantities transferred between the models in these studies. The use of reaction-force measurements by Gorelik et al. [132] to determine exit velocity provides a momentum constraint in addition to mass flow rate. The exit source terms discussed by Pinhasi et al. [30] supply conditions for subsequent expansion and phase change. If the selected section is close to the opening, the remaining pressure difference and associated downstream acceleration are still part of the external-flow problem. Enthalpy transport also accounts for the latent energy consumed or released by phase change. Exit data taken at different sections thus assign different stages of the process to the downstream calculation.
Busov [41] discusses differences in jet morphology between constant-pressure outflow and releases with varying pressure, while Zhu et al. [69] studied jet breakup during vessel depressurization. These studies illustrate two boundary conditions. Approximately steady releases can be compared at specified inlet states; in releases from a finite inventory, pressure, temperature, and flow rate evolve together. Table 1 summarizes the relevant quantities and their observational interpretation. Section 3.4 compares the transient evidence in more detail.

2.3. Differences in Definitions and Measurements Across Studies

The short-tube experiments of Chun et al. [32] and the transparent circular-tube experiments of Pan et al. [33] examine geometric effects through the discharge rate and internal phase distribution, respectively. Chun et al. measured different mass fluxes even at similar length-to-diameter ratios L/D, whereas Pan et al. related the near-exit void fraction to external jet morphology. These results are complementary: the aspect ratio describes passage proportions, while the absolute dimensions and development of vaporization within the passage help determine the actual exit state. The thermodynamic boundaries also define different comparisons. Varying temperature and pressure together along the saturation curve does not isolate the same effects as changing temperature or back pressure independently.
Dimensionless descriptions retain differences in parameter definitions. Mansour and Müller [14] define the Jakob number as the ratio of sensible to latent heat, Ja = cp,lΔT/hfg. Bar-Kohany and Levy [5] call this form the Stefan number and define the Jakob number with a density ratio, Ja = ρlcp,lΔT/(ρghfg). Here, cp,l is the liquid specific heat capacity and hfg is the latent heat of vaporization; ΔT and the reference states for fluid properties follow the definitions in each study. Pan et al. [33] use the form containing the density ratio and define the Weber number using vapor density and orifice diameter. Ji et al. [64] found that increasing temperature and reducing chamber pressure both increased their Ja, but the flashing efficiency responded differently to the two paths. The first differences arise from naming and normalization; the latter reflects a dependence on the operating path that a single parameter does not fully capture.
The diagnostics also provide complementary observation scales. The flow rates measured by Isbin et al. [27] constrain integral transport, while the near-exit phase fractions and visualizations of Pan et al. [33] connect internal and external structures. Optical methods developed for nonaqueous sprays by Lu et al. [50], Du et al., and Qiu et al. [51,52,53] provide methods for spatially resolving droplets and spray structure. Thermal measurements by Cai et al. [55] and Busov et al. [59], together with the analysis of water and steam effects by Trofimov et al. [60], add temperature data and clarify how those measurements should be interpreted. Section 3 therefore compares flow rate, morphology, droplet size, and thermal response at their respective spatial, temporal, and statistical scales.

3. Experimental Evidence and Understanding of Flashing Jets

Experimental studies of water flashing have progressively extended from bulk discharge to local phase conditions and external transport. In 1978, Gorelik et al. measured flow rate, the axial pressure distribution, and reaction force together in a Laval nozzle [132]. In 1996, Chun et al. examined short-tube geometry, subcooling, and critical mass flux [32]. In 2024, Pan et al. combined a transparent passage, capacitance probes, and high-speed imaging to relate the phase fraction inside the passage to the external jet morphology [33]. These studies provide evidence on release rate, the progression of vaporization, and the relationship between internal and external structures, respectively. Measurements of droplet size, temperature, humidity, and transient behavior have further extended observations to transport after breakup.

3.1. Flow and Discharge Characteristics Within the Passage

3.1.1. Mass Flux and Vaporization State

Chun et al. found that both the absolute dimensions and the length-to-diameter ratio of short tubes affect mass flux [32]. In long transparent circular tubes, Pan et al. found that initial pressure mainly changes the discharge rate, whereas reservoir water temperature and bore diameter substantially alter the near-exit void fraction and external morphology [33]. The two studies address different manifestations of the same vaporization process: the former quantifies release rate, while the latter shows how the discharged vapor contributes to the formation of near-field structures.
Chun et al. compared short-tube specimens at the same stagnation pressure. At a given temperature and length, the larger-diameter specimen had a higher mass flux; at a given temperature and diameter, the longer flow path had a lower mass flux [32]. Even with similar length-to-diameter ratios, the mass fluxes read from the plots for the 3.4 mm × 100 mm and 7.15 mm × 200 mm tubes at 1.5 MPa and approximately 100 °C were approximately 4.0 × 104 and 3.3 × 104 kg m−2 s−1, respectively. This comparison shows that similar length-to-diameter ratios do not eliminate the effects of absolute scale. The dimensions and operating conditions of the four specimens are listed in Table 2.
The inlet mass fluxes for the two BNL runs reproduced by Jin et al. were 4.33 × 103 and 4.30 × 103 kg m−2 s−1 [93], normalized by the inlet area of the converging-diverging nozzle. The short straight-tube data of Chun et al. involve different temperatures, pressures, flow paths, and normalization conditions. In cold- and hot-water crack tests, Revankar and Riznic further found that, at a fixed stagnation pressure, the hot-water mass flux was lower and increased with subcooling [35]. Together, these studies show how inlet vaporization conditions and the effective flow path affect release rate. Numerical differences between facilities also reflect differences in the reference area and thermodynamic path.
In vacuum injection experiments with water and ethanol, Kitamura et al. related near-exit spreading and downstream breakup to the progression of vaporization inside the nozzle [20]. Wide-angle spreading close to the exit could occur near the boiling point at the chamber pressure, whereas at higher superheat the jet could travel some distance before breaking up rapidly. The superheat required for complete breakup also depended on flow velocity and bore diameter. The authors distinguished discharge that was already two-phase inside the nozzle from rapid boiling after the exit, indicating that residence time and the development of nucleation help determine the breakup location.
Using capacitance measurements in long transparent circular tubes, Pan et al. related the near-exit phase fraction to the external morphology under the same operating conditions [33]. The phase fraction varied with reservoir water temperature and bore diameter and distinguished the observed morphologies better than the inlet Jakob-number Ja-Weber-number We criterion evaluated in that study. Initial pressure had a weaker effect on the phase fraction during the stable stage. The actual vapor content thus provides direct evidence for morphological differences beyond inlet dimensionless parameters. The thresholds reported in that study apply to its long-tube conditions and sensor calibration; the authors estimated a measurement error of approximately 15%.
The breakup locations observed by Kitamura et al., mass fluxes measured by Chun et al., and near-exit phase fractions measured by Pan et al. reveal the relationship between flow time and vaporization development at different stages [20,32,33]. Bulk measurements in short tubes, morphology observations with long nozzles, and phase measurements in transparent tubes complement one another and support the role of internal vaporization in shaping external breakup. Absolute dimensions, length-to-diameter ratio, and back pressure are the main differences in conditions among these three bodies of evidence.

3.1.2. Crack Geometry and Equivalence

In preliminary tests on specimens with artificial axial cracks, Zhang et al. found that further pressurization could irreversibly increase the crack opening [34]. Before comparing cold- and hot-water tests on stress corrosion cracks, Revankar and Riznic applied cyclic loading until the area measured offline stabilized [35]. The former study directly recorded load-induced geometric changes, whereas the latter used stabilization by loading as a prerequisite for comparing cold- and hot-water flow rates. Both studies show that crack area depends on the loading state; geometric records and loading history jointly define its relevance to discharge.
Schmid et al. compared fatigue cracks and artificial slits with similar external opening areas and found appreciable differences in flow rate, alongside differences in roughness and hydraulic diameter [36]. The stress corrosion crack data of Revankar and Riznic [35] and the artificial short-slit data of Zhang et al. [37] also show the effects of initial thermodynamic conditions, passage dimensions, and opening orientation on mass flux. These results extend the interpretation of crack discharge from the external opening area to the entire flow path. The separate contributions of roughness and hydraulic scale remain unresolved.
In crack tests at multiple back pressures, Zhang et al. observed that, during discharge to the atmosphere with an inlet liquid temperature above 100 °C, flow rate decreased as temperature increased. They attributed this behavior to flashing near the exit based on the measured temperatures, pressures, and flow rates [38]. This hot-water behavior is consistent with the cold- and hot-water crack and short-slit data [35,37], showing that the initial thermodynamic state can change discharge characteristics within the same flow path. The vaporization location in this experiment was inferred indirectly, and the relevant temperature conditions also vary with back pressure.
Zhang et al. conducted controlled comparisons of fluid-structure coupling and nonequilibrium treatments for narrow axial slits in thin-walled tubes [39]. The mean flow-rate error decreased from 28.7% without either correction to 27.0% with the nonequilibrium treatment alone, 13.9% after additionally accounting for pressure-induced opening, and 9.5% after further accounting for temperature-induced opening. For these specimens and conditions, the incremental improvement from correcting the opening exceeded that from modifying the phase-change relation alone. Circumferential cracks were more sensitive to assumptions about the effective flow area. The study thus demonstrated the importance of crack type and geometry under pressure in discharge models.
The area-flow-rate comparisons of Schmid et al. [36] distinguish geometric and hydraulic levels of crack equivalence: similar external projected areas can still produce different flow-rate responses to pressure difference. The exit phase state and momentum also affect comparisons of the external source term. Figure 3 organizes these observables into three levels of comparison: area, hydraulics, and exit state. Crack data support the first two, whereas the third requires additional vapor-liquid and momentum information.
Crack studies have established links among loading, the flow path, and hot-water discharge [34,35,36,37,38,39]. Geometric measurements before and after loading reveal changes in the opening; comparisons of cold-water flow rates reveal effective resistance; and cold- versus hot-water comparisons reveal the combined effects of vaporization and deformation. Most evidence concerns geometry and total leakage rate. Phase-resolved exit conditions remain the main gap when extending these findings to the external jet.

3.2. Near-Exit Morphology and Droplet Size Distributions

3.2.1. Jet Morphology and Influencing Factors

Busov observed jet spreading followed by contraction in experiments with both semicircular exits and short circular passages [40,41]. Short-slit studies by Reshetnikov et al. and Pavlenko et al. further showed that adjacent surfaces and flange configurations alter spreading and reaction force [42,44,45]. Together, these results show that vaporization and the exit boundary jointly shape the near-field morphology. Temperature effects must therefore be interpreted in the context of the specific geometry and liquid-supply history.
In atmospheric discharge experiments with a short semicircular nozzle, Busov observed complete spreading over approximately 180° at saturation pressures of approximately 1.9-6.4 MPa, followed by contraction to approximately 30° in the deeply superheated regime [40]. Comparisons of short circular passages showed that the smaller-diameter passage maintained stable, complete spreading, whereas the larger-diameter passage contracted at higher initial temperatures; the author associated the latter behavior with an unstable supply pressure [41]. Contraction occurred at high superheat in both studies, but geometry and liquid-supply stability provided different clues to the mechanisms.
Reshetnikov et al. discharged water through a short slit with a diverging clamping flange to the atmosphere while varying the upstream state along the saturation line. The measured angle across the short side decreased from approximately 80° to 55°, while that across the long side remained approximately 20°. No abrupt critical transition in morphology or reaction force occurred in the tested configuration, and the reaction force on the high-pressure branch could exceed the cold-liquid hydraulic approximation by 30% [44]. Other comparisons of free short-slit jets, adjacent planes, and diverging flanges recorded wall attachment, complete spreading, and a decrease in reaction force during spreading [42,45]. Circular holes and slits also followed different spreading paths [43]. These studies show that the relationship between reaction force and spreading angle depends on geometry.
Busov et al. compared swirling short-slit jets along two thermodynamic paths: at fixed pressure and along the saturation line. With and without swirl, the morphologies were similar at low superheat; swirl produced a larger spray angle at moderate superheat, while the difference diminished at high and extreme superheat [46]. Their circular-orifice experiments with a twisted tape also recorded changes in the liquid core and morphological stability [47]. Swirl alters the local distribution of motion, but its effect on spreading angle depends on the vaporization state.
Busov’s semicircular nozzle [40] and the flanged short slit studied by Reshetnikov et al. [44] both used water, followed the saturation line, and discharged to the atmosphere, yet produced different extents and directions of spreading. Both studies defined angles from the visible boundaries, and the short-slit study reported angles in two observation planes. Under similar thermodynamic paths, these differences point to exit shape, adjacent surfaces, and supply-pressure history as explanations for spreading and contraction. They also show that direction-resolved spray angles retain more structural information than a single overall angle.

3.2.2. Droplet Size Distributions and Measurement Methods

Busov collected droplets discharged from a short semicircular nozzle to the atmosphere on epoxy-coated glass slides and calculated the Sauter mean diameter (SMD) from microscopic measurements [40]. As temperature and pressure increased along the saturation line, the SMD calculated using SMD = ∑ i n i D i 3 ∑ i n i D i 2 decreased from approximately 107 to 14 μm, as read from the plot, while the reduced saturation pressure ps/pc increased from 0.01 to 0.41. The sampling location was not reported, so these statistics describe the captured droplet population. Zalkind et al. reported a characteristic diameter of approximately 1 μm for a diverging nozzle at approximately 200 °C [48]; their metric was not the SMD defined above.
Rogóż et al. independently controlled liquid temperature and ambient pressure while maintaining a pressure difference of 5 bar across a 150 μm effective single orifice. They used a shadowgraph field centered on the jet axis and the same volume-to-surface-area mean definition [49]. At a fixed temperature of 120 °C, increasing the saturation-to-ambient pressure ratio from 0.90 to 2.47 reduced the SMD from 51.3 to 28.4 μm. This decrease in droplet size as back pressure was reduced at constant temperature agrees in direction with Busov’s decrease from approximately 107 to 14 μm along the saturation line [40], although the thermodynamic paths, nozzles, and sampling methods differ. Rogóż et al. also measured different size-distribution shapes at similar pressure ratios [49], further showing that the pressure ratio cannot fully replace the separate information carried by temperature and back pressure.
Lu et al. combined extended glare-point imaging with particle tracking in flashing fuel sprays to obtain spatially resolved joint size-velocity distributions [50]. Such measurements extend studies of droplet size reduction beyond a single SMD to the mass contribution of large droplets, correlations between size and velocity, and inertial trajectories, providing a diagnostic reference for hot-water sprays. Distribution tails and statistical weighting directly affect estimates of liquid carryover, settling, and interception by a target surface.
Du et al. used spatiotemporal tomography and structured illumination using two phase-shifted patterns to observe layers and three-dimensional structures in fuel sprays [51,52], while Qiu et al. used structured illumination using three phase-shifted patterns to measure droplet sizes in dense sprays [53]. Yang et al. related bubbles inside a transparent n-hexane nozzle to near-field image fluctuations [54]. These studies improve the observability of structure or droplet size under multiple scattering and demonstrate links between internal dynamics and the external spray. They use fluids other than water and address different spatial and temporal statistics. Application to hot-water jets must also account for vapor-induced refraction, evaporation, condensation, and pressure-resistant optical boundaries.

3.3. Downstream Heat and Mass Transport

3.3.1. Temperature and Humidity Responses and Influencing Factors

Cai et al. discharged hot water through a 2 mm orifice into an atmospheric chamber and recorded an axial temperature profile with a small initial change, rapid cooling, and gradual stabilization [55]. At 3.5 MPa and 423 K, increasing the mass flow rate from 0.04 to 0.06 kg/s moved the inflection point of the fitted K-type thermocouple temperature profile from 16.54 to 41.45 mm. This controlled comparison directly shows that the characteristic location in the measured temperature profile shifts downstream as flow conditions change. The inflection point characterizes the temperature response; the location at which vaporization is complete is a separate observable.
In their 1981 study of low-temperature sprays, Miyatake et al. estimated t = z/u using the mean nozzle-exit velocity and correlated it with temperature [56]. In their 2009 study of upward injection, Mutair and Ikegami accounted for velocity changes caused by drag and entrainment and instead correlated the temperature decrease with axial distance [66]; they subsequently extended the study to desalination conditions [57]. Fathinia et al. related dimensionless temperature to evaporation rate in fine sprays of water and saline solution [58]. Like Cai et al.’s high-temperature downward-injection results [55], these data show rapid initial cooling followed by a slower decrease. Differences in cooling length correspond to changes in injection direction, velocity, flow rate, and the definition of the measured temperature.
Busov et al. used visible-light and 7.5-14 μm infrared imaging separately to record rapid axial cooling and transverse apparent-temperature distributions in water jets from short circular orifices [59]. Although the emissivity was set to 0.95, the authors described the thermographic temperatures as approximate and qualitative. Trofimov et al.’s studies of optical paths containing water and droplet-laden steam demonstrated wavelength dependence [60], helping explain this measurement limitation. Thermography adds spatial thermal-field information under specified imaging conditions; accurate phase-resolved temperatures require additional evidence.
In a flashing chamber open to the atmosphere, Cai et al. found that increasing the feed-water flow rate or initial temperature produced a steeper humidity rise at upper-wall probe 2, while changing the injection direction altered the response history [63]. Their temperature study also recorded a downstream shift of the cooling-profile inflection point as flow rate increased [55]. Together, these results link local temperature and humidity responses to release rate and the transport path. The signals are sensitive to source-term changes, while probe location, temperature, and background humidity determine their spatial significance.
Ji et al. defined steam-generation efficiency as the ratio of generated-steam to feed-water mass flow rate in a saturated-steam chamber. Both increasing temperature and decreasing chamber pressure increased Ja, defined here to include the density ratio, but the slopes of the efficiency changes differed [64]. Under the tested conditions, downward injection generated more steam and produced less liquid carryover, which the authors attributed to earlier removal of upward-injected droplets by the steam. In low-temperature experiments, Ikegami et al. found that upward injection approached the chamber saturation temperature over a shorter distance under some conditions [65]. The former study addresses mass output, whereas the latter addresses local cooling length. The findings reflect different effects of injection direction on residence and carryover.

3.3.2. Evaporation, Condensation, and Settling

Fathinia et al. measured the spray angle and droplet size of full-cone nozzles in vacuum saline sprays and used downstream droplet sizes from one nozzle type to assess their model [61]. In subsequent multiple-nozzle experiments, they compared droplet size, evaporation rate, and an output ratio normalized by the supplied superheat energy under fixed-flow-rate and fixed-injection-pressure conditions [62]. Both studies relate nozzle configuration and the droplet population to system output. Fixed flow rate and fixed pressure represent different constraints on the liquid supply.
In a pilot-scale water facility, Hocquet et al. distinguished stable liquid columns, progressive mechanical breakup, and flashing breakup near the exit through jet observations. Collection troughs measured the downstream rainout distribution, which changed, together with the jet range, on transition to flashing breakup [67]. These measurements directly connect near-field morphology to downstream rainout. They record the liquid distribution jointly produced by initial breakup scales, droplet motion, and subsequent phase change.
In steam jets entering air, Kim et al. used a condensate separator to reduce upstream droplet carryover, yet still measured fine condensation droplets downstream. They also recorded changes in jet temperature, droplet velocity, and droplet size with flow rate [68]. Hocquet et al.’s liquid-water study related droplet formation to jet breakup and subsequent rainout [67]. Together, these studies identify breakup-generated droplets and droplets formed by condensation during mixing, showing that liquid water in a leakage plume can arise through different processes. Local temperature and humidity conditions and the liquid-water balance are the key quantities connecting these sources to their subsequent fate.
The droplet-size and evaporation measurements of Fathinia et al. [61,62], rainout collection experiments of Hocquet et al. [67], and condensation-droplet observations of Kim et al. [68] reveal droplet shrinkage after formation, deposition on the ground, and the formation of new liquid water, respectively. Figure 4 connects breakup, condensation during mixing, transport with the flow, settling, and impingement. Existing studies cover several possible fates, but the fractions following each path are still mainly derived from separate experiments.

3.4. Unsteady Discharge and Transient Response

3.4.1. Liquid-Supply History and Source-Term Evolution

During a single vessel blowdown, Zhu et al. combined pressure measurements, weighing, and high-speed imaging to directly record the coupled evolution of pressure, flow rate, and jet morphology [69]. Busov’s short-passage study also associated the inability to maintain complete spreading with unstable supply pressure [41]. Both studies extend the interpretation of morphology from initial temperature and pressure to the actual liquid-supply history, showing the coupling between depletion of a finite inventory and near-field vaporization and breakup.
Zhu et al. further combined stability analysis, bubble dynamics, and regression based on dimensional analysis to explain breakup evolution during vessel blowdown. In the external-flashing regime, slower growth of mechanical disturbances can allow more time for bubble growth, increasing the vapor volume and energy released when bubbles burst. In the internal-flashing regime, depressurization can advance nucleation and increase the number of bubbles inside the nozzle, strengthening thermodynamic effects [69]. These proposed mechanisms are linked to the source-term and morphology histories recorded in that study and help explain why flashing breakup can persist as pressure falls. The transient share attributed to each mechanism depends on the model decomposition.
Wang et al. coupled gas discharge from a chamber, evaporation, and changes in gas composition, and compared the results with water temperature and evaporated mass. Their study showed that the depressurization history arises from the combined system processes [70]. Compared with vessel-blowdown jets, this study makes the roles of liquid-supply and gas-discharge boundaries explicit. Its evidence concerns depressurization within a chamber rather than the startup of a free jet.
Wang et al. measured oscillations in flow rate, void fraction, and temperature in a scaled natural-circulation water loop and related them to flashing-induced acceleration, condensation in the heat exchanger, and loop feedback [71]. In contrast to the single depletion event recorded by Zhu et al. for a finite inventory [69], continuing loop feedback sustained the periodic changes. The two studies show the respective effects of a decaying source term and recirculating feedback on phase-change evolution under different system boundaries.
Figure 4. Downstream multiphase transport from a near-horizontal hot-water release. (a) The momentum-dominated near field in still air; Ta and RHa denote ambient temperature and relative humidity. Short axial arrows indicate the mean near-axis gas flow, adjacent dashed lines indicate gas-flow spreading within the jet, and outer curves indicate air entrainment. Green dots show the spatial distribution of droplets; purple lines trace the settling of some larger droplets after they depart from the gas flow. (b) Evaporation or condensational growth of existing droplets depends on the relation between the local water-vapor partial pressure pv and the equilibrium vapor pressure peq at the interfacial temperature Ts. Formation of new condensation droplets additionally requires nucleation. (c) Droplets can depart from the gas flow through inertia and impinge on a surface; their post-impact state depends on droplet and surface conditions. Dilution, phase change, and separation jointly affect liquid-water concentration. The far field is also influenced by ambient wind, heat and mass exchange, and mixture buoyancy [25,26,61,67,68]. Water-jet images [69] support the morphology, free-jet research [148] supports the distinction between mean convection and entrainment, and R134a flashing experiments [149] support the distinction between gas- and liquid-phase velocimetry. The latter two studies do not provide a quantitative gas-velocity field for the hot-water conditions shown here. Condensing-steam research [144] informs the phase-change mechanism; its scaling laws do not transfer directly to hot-water releases containing coarse droplets.
Figure 4. Downstream multiphase transport from a near-horizontal hot-water release. (a) The momentum-dominated near field in still air; Ta and RHa denote ambient temperature and relative humidity. Short axial arrows indicate the mean near-axis gas flow, adjacent dashed lines indicate gas-flow spreading within the jet, and outer curves indicate air entrainment. Green dots show the spatial distribution of droplets; purple lines trace the settling of some larger droplets after they depart from the gas flow. (b) Evaporation or condensational growth of existing droplets depends on the relation between the local water-vapor partial pressure pv and the equilibrium vapor pressure peq at the interfacial temperature Ts. Formation of new condensation droplets additionally requires nucleation. (c) Droplets can depart from the gas flow through inertia and impinge on a surface; their post-impact state depends on droplet and surface conditions. Dilution, phase change, and separation jointly affect liquid-water concentration. The far field is also influenced by ambient wind, heat and mass exchange, and mixture buoyancy [25,26,61,67,68]. Water-jet images [69] support the morphology, free-jet research [148] supports the distinction between mean convection and entrainment, and R134a flashing experiments [149] support the distinction between gas- and liquid-phase velocimetry. The latter two studies do not provide a quantitative gas-velocity field for the hot-water conditions shown here. Condensing-steam research [144] informs the phase-change mechanism; its scaling laws do not transfer directly to hot-water releases containing coarse droplets.
Preprints 246046 g004

3.4.2. Fluctuations in Jet Structure

In short-orifice experiments, Reshetnikov et al. found that complete spreading coincided with a decrease in reaction force and stronger fluctuations in transmitted-light intensity, whose power spectrum showed enhanced low-frequency components [72]. Short-slit transition regimes also exhibited an approximately 1/f low-frequency spectrum of transmitted-light intensity fluctuations [42]. Busov et al.’s swirl experiments further related transmission fluctuations to liquid-core oscillations and changes in morphology [73]. Across different geometries, these studies link structural transitions to optical fluctuations. The directly observed quantities reflect obscuration, scattering, and liquid-core motion; the reaction force in [72] was obtained separately by calibrating the working-chamber displacement. Spectra of transmitted-light intensity fluctuations and load spectra are distinct measurements.

3.4.3. Pressure Propagation and Transient Pulses

Mansour and Müller injected water at 40-100 °C into a vacuum chamber at 4-10 kPa and used schlieren imaging to record a moving density-gradient front surrounding the jet, which they interpreted as a shock wave [74]. This work extended observations of rapid flashing from the jet interior to an externally propagating structure and provided evidence of the front’s position and motion. Identifying the wave type and strength also requires pressure and propagation-speed information under the same conditions.
He et al. used piezoelectric measurements sampled at 20 kHz to record depressurization, pressure undershoot, and external pulses during rapid opening of a hot-water pipe end [75]. In one run with an initial pressure of 0.7 MPa and a subcooling of 15.5 K, the plotted absolute-pressure peak 25 mm from the pipe outlet was approximately 0.94 MPa. This value represents a local transient pressure, not the pressure difference across the propagating front. Compared with the schlieren data of Mansour and Müller [74], the two studies provide direct pressure histories and propagation structures, respectively. Their geometries, temperatures, pressures, and back pressures differ, so this complementary evidence still comes from different operating conditions.

3.5. Main Experimental Findings

Experimental studies have progressively connected the effective flow path, exit phase state, and environmental response. Geometry and the initial thermodynamic state affect discharge; exit vapor content, adjacent surfaces, and supply-pressure history affect spreading; and droplet size, cooling, and rainout reveal the downstream fate of liquid water. Controlled comparisons within a single facility provide direct evidence of parameter effects, while results from multiple facilities reveal common trends and different mechanistic explanations. The main differences governing cross-facility comparisons concern phase state, observation location, temporal statistics, and size weighting, beyond the numerical magnitudes alone.
Figure 5 shows the geometric coverage of representative water experiments, Table 2 summarizes their apparatus, operating conditions, and results, and Table 3 distinguishes the main findings, evidence types, and unresolved questions. On this basis, Section 4 compares the extent of model validation for bulk quantities, local phase conditions, and downstream transport.
The data of Chun et al. and Pan et al. in Figure 5 partly overlap in circular-tube diameter but differ substantially in flow-path length [32,33]. Zhang et al.’s short micrometer-scale slits and Busov’s semicircular nozzle use slit width and a flow-derived diameter, respectively [37,40]. These studies broaden the geometric coverage for water while introducing different combinations of scale and flow path. Table 2 retains the associated operating conditions and diagnostic definitions, allowing actual size effects to be distinguished from differences in cross section, observation plane, sampling weight, and thermodynamic path.
Droplet-size comparisons within a single facility further illustrate the information contained in different statistics. Rogóż et al. [49] independently controlled liquid temperature and ambient pressure at a fixed pressure difference across the orifice (5 bar) and fixed single-orifice geometry. Both sets of constant-temperature conditions reported in their Table 3 show that increasing the saturation-to-ambient pressure ratio reduces both the SMD and the size scale of the large-droplet tail. Figure 6 plots the changes in the mean size and tail using these experimental values. Comparisons across studies additionally require the geometries shown in Figure 5 and the thermodynamic paths and sampling methods listed in Table 2.
Table 2. Apparatus, operating conditions, diagnostics, and main findings of representative experimental studies.
Table 2. Apparatus, operating conditions, diagnostics, and main findings of representative experimental studies.
Study Apparatus and geometry Operating conditions Diagnostics Main findings
Chun et al. [32] Four short circular tubes, d/L (mm/mm): 3.4/100, 7.1/100, 7.15/200, and 7.15/400; corresponding L/D: 29.4, 14.1, 28.0, and 55.9 0.5-2.0 MPa; inlet subcooling of 0-199.3 K across the four specimens; 135 tests Mass flux inferred from water-level time histories; axial pressure measurements At the same stagnation pressure and temperature, mass flux increased with diameter at fixed length and decreased with flow-path length at fixed diameter. At 1.5 MPa and approximately 100 °C, plot readings for the 3.4 mm × 100 mm and 7.15 mm × 200 mm tubes were approximately 4.0 × 10⁴ and 3.3 × 10⁴ kg·m⁻²·s⁻¹, normalized by the straight-tube cross section
BNL data reproduced by Jin et al. [93] Converging-diverging nozzle; total length 787 mm, end internal diameter 51 mm, and throat diameter 25 mm RUN309/268: inlet temperatures 422.25/422.05 K; tabulated inlet/back pressures 555.9/378.3 and 575.2/451.8 kPa, respectively Inlet mass flux reproduced from the original experiments Inlet mass fluxes of 4.33 × 10³ and 4.30 × 10³ kg·m⁻²·s⁻¹ for the two runs, normalized by the nozzle inlet area; cross section, geometry, temperature, and pressure differ from Chun’s short straight-tube tests
Kitamura et al. [20] Long stainless-steel nozzle discharging into a vacuum chamber Water and ethanol, including conditions near the boiling point at the chamber pressure External imaging At higher superheat, the jet broke up rapidly some distance beyond the nozzle; the superheat required for complete breakup varied with flow velocity and bore diameter
Pan et al. [33] Transparent circular tubes, L = 800 mm and d = 1 − 6 mm Variable reservoir water temperature, bore diameter, and initial pressure Capacitance measurements of phase fraction; separate observations of internal and external flow under the same conditions Reservoir temperature and bore diameter affected the near-exit phase fraction and morphology; initial pressure mainly affected discharge rate; estimated sensor error of approximately 15%
Axial-crack tests [34] Artificial axial cracks Room-temperature water; initial opening of 0.15 mm in two preliminary specimens; stepwise loading by inlet gauge pressure Flow-rate response to pressure difference; microscopy before and after testing Further increases in inlet gauge pressure from 9 MPa to 10.2 or 15.5 MPa irreversibly enlarged the opening; 9 MPa was subsequently adopted as a conservative operating limit for this set of specimens
Revankar and Riznic [35] Five stress corrosion cracks in steam-generator tubes Cold- and hot-water leakage; cyclic preloading at 6.89 MPa until the area measured offline stabilized Offline microscopy and leakage flow-rate measurements At fixed stagnation pressure, hot-water mass flux was lower than cold-water mass flux and increased with subcooling; choked mass flux varied with pressure and passage dimensions; opening areas were stable values after high-pressure conditioning
Schmid et al. [36] Regular holes, artificial slits, and fatigue cracks (R6 and 010T16) Leakage flow-rate comparisons Opening-area and flow-rate measurements The R6 fatigue crack and 010T16 artificial slit had similar external opening areas but different flow rates; the fatigue crack also had greater roughness and a smaller hydraulic diameter
Zhang et al. [37] Artificial short slits, opening 46.5-220 μm and L/D = 4-21 Hot water Leakage flow-rate measurements Both inlet conditions and geometric differences between axial and circumferential openings affected leakage flow rate
Hot-water tests at multiple back pressures [38] Crack passages tested at multiple back pressures The reported flow-rate decrease occurred during atmospheric discharge with inlet liquid temperatures above 100 °C Flow rate, temperature, and pressure Flow rate decreased markedly with increasing temperature; the authors proposed near-exit flashing as an explanation based on temperature, pressure, and flow-rate measurements
Zhang et al. [39] Narrow cracks in thin-walled tubes Hot-water leakage Leakage tests, finite-element analysis, and a lumped-parameter model Mean flow-rate error for narrow axial slits: 28.7% without corrections, 27.0% with nonequilibrium alone, 13.9% with pressure-induced opening added, and 9.5% with temperature-induced opening further added; circumferential-crack predictions depended on the assumed effective flow area
Semicircular-exit tests [40] Semicircular nozzle; area inferred from cold-water flow rate and an assumed discharge coefficient, then converted to an equivalent circular diameter of 0.58 mm Water; temperature and pressure varied together along the saturation line; atmospheric discharge; saturation pressure of approximately 1.9-6.4 MPa on the fully spread branch Jet imaging Full included angle defined by visible boundaries: complete spreading over approximately 180°, followed by contraction to approximately 30° in the deeply superheated regime
Busov [41] Short passages, L = 1 mm, with d = 0.33 and 0.63 mm; atmospheric discharge Variable initial temperature Jet imaging and spray-angle statistics; vessel temperature and pressure monitoring Stable, complete spreading with the smaller diameter; contraction at higher initial temperatures with the larger diameter, attributed by the author to unstable supply pressure
Short-slit tests with adjacent surfaces [42] Short slit; comparisons among a free jet, an adjacent plane, and a diverging flange — Imaging, jet reaction force at the source, and laser-transmission fluctuations Adjacent surfaces altered spreading and wall attachment; the jet reaction force decreased at complete spreading; some transition regimes exhibited an approximately 1/f low-frequency spectrum of transmitted-light intensity fluctuations
Circular-orifice and slit comparison [43] Circular orifices and slits — Imaging The two exit types followed different spreading paths
Short-slit planar-jet tests [44] Short slit with a 4 mm × 0.2 mm cross section and a length of 0.7 mm; diverging clamping flange 373-573 K and pressures up to 10 MPa; upstream state varied along the saturation line; atmospheric discharge Simultaneous morphology and reaction-force measurements No abrupt critical transition in the tested configuration; spray angle across the short side decreased from approximately 80° to 55°, while that across the long side was approximately 20°; high-pressure reaction force could exceed the cold-liquid approximation by 30%
Short-slit comparisons with adjacent surfaces [45] Short-slit exit with and without an external adjacent surface — Imaging and reaction-force measurements Adjacent surfaces altered complete spreading and jet reaction force; falling-film heating was a separate experimental part of the same paper
Short-slit swirl comparisons [46] Swirling short-slit jets and a nonswirling baseline Initial state varied at fixed pressure or along the saturation line Imaging Similar morphologies with and without swirl at low superheat; larger spray angle with swirl at moderate superheat; weaker differences at high and extreme superheat under both control modes
Circular-orifice tests with a twisted tape [47] Circular orifice with a twisted tape approximately 3 mm from the nozzle — Imaging Changes in the liquid core and morphological stability were observed
Glass-slide collection tests [40] Semicircular nozzle Water; temperature and pressure varied together along the saturation line; atmospheric discharge; reduced saturation pressure approximately 0.01 → 0.41 Brief collection on epoxy-coated glass slides and microscopic statistics; histograms weighted by volume fraction; specific sampling location not reported SMD read from the plot: approximately 107 → 14 μm; droplet sizes approximately 15-220 μm at 393 K and 5-30 μm at 578 K; values describe the captured droplet population
Diverging-nozzle tests [48] Diverging nozzle Approximately 200 °C Droplet-size measurements Unimodal distribution with a characteristic diameter of approximately 1 μm, not defined as SMD in the original paper
Rogóż et al. [49] 150 μm effective single orifice, with two of the original three holes sealed; pressure difference of 5 bar across the orifice Water; independent control of liquid temperature and ambient pressure; Rp = psat(Tl)/pa, with absolute pressures in both numerator and denominator Shadowgraph field centered on the jet axis; volume-weighted droplet-size distribution and SMD At 120 °C: pressure ratio 0.90 → 2.47, SMD 51.3 → 28.4 μm, and diameter at 90% cumulative volume 133.9 → 55.2 μm. At 140 °C: pressure ratio 1.03 → 1.89 and SMD 50.3 → 35.5 μm. Distribution shapes differed at similar pressure ratios with different temperatures and back pressures
Lu et al. [50] Fuel spray Flash-boiling conditions Extended glare-point imaging and particle tracking Spatially resolved joint droplet size-velocity distributions
Cai et al. [55] 2 mm orifice discharging into an atmospheric chamber 3.5 MPa and 423 K: mass flow rate of 0.055 kg/s and a comparison over 0.04 → 0.06 kg/s Axial K-type thermocouple measurements Rapid-cooling region of approximately 59 mm in an example case; increasing mass flow rate from 0.04 to 0.06 kg/s shifted the fitted temperature-profile inflection point from 16.54 to 41.45 mm
Miyatake et al. [56] Spray evaporation Inlet water temperatures of 40, 60, and 80 °C Temperature measurements Mean nozzle-exit velocity used to estimate t = z/u and relate jet-centerline liquid temperature to travel history
Low-temperature upward-injection tests [57] Upward injection Low-temperature conditions Temperature measurements Empirical curves for the axial temperature decrease
Saline-spray study [58] Fine sprays of water and saline solution — Temperature and evaporation rate Comparison of dimensionless temperature and evaporation rate
Busov et al. [59] Water jets from short circular orifices — Visible-light photography for morphology; separate infrared apparent-temperature measurements at 7.5-14 μm with an emissivity of 0.95 Rapid axial cooling and transverse temperature distributions that varied with jet morphology
Cai et al. [63] Flashing chamber open to the atmosphere At 8 MPa and 473 K: mass flow rate 3.3 → 18.3 g/s; at 15 MPa and 15 g/s: variable initial temperature; at 8 MPa, 473 K, and 16.7 g/s: variable injection direction Temperature and relative humidity at upper-wall probes In the respective controlled comparisons, increasing flow rate or initial temperature produced a steeper relative-humidity rise at upper-wall probe 2; injection direction altered the response history
Pressurized saturated-steam chamber tests [64] Pressurized saturated-steam chamber Water temperature 135.0-150.8 °C and absolute chamber pressure 121-146 kPa; saturated-steam environment Efficiency defined as generated-steam mass flow rate divided by feed-water mass flow rate; injection-direction comparisons At the same Ja, efficiency depended on whether temperature was increased or pressure decreased; under the tested conditions, downward injection generated more steam and produced less liquid carryover
Full-cone nozzle study [61] Three full-cone nozzle types Saline spray in a vacuum chamber High-speed photography and shadowgraphy for spray angle and droplet size Downstream droplet sizes used to assess the model; droplet lifetimes estimated by the model
Multiple-nozzle saline-spray tests [62] Multiple-nozzle saline spray Saline spray in a vacuum chamber; comparisons at fixed flow rate and fixed injection pressure Droplet size, evaporation rate, and output ratio normalized by the supplied superheat energy Comparison of the effects of liquid-supply constraints and nozzle configuration on system output
Hocquet et al. [67] Pilot-scale water facility Variable inlet temperature, pressure, bore diameter, and flow-path length Jet observations; collection troughs arranged along the jet Three jet types: stable liquid column, progressive mechanical breakup, and flashing breakup near the exit; the rainout distribution and jet range changed markedly on transition from mechanical to flashing breakup
Kim et al. [68] Steam jet entering air Variable flow velocity Thermocouples for jet temperature; PDPA for droplet size and velocity Condensation response and its dependence on flow velocity
Zhu et al. [69] Blowdown of a 20 L vessel Liquid-release stages (I and II) during blowdown of a finite inventory Pressure measurements, weighing, and imaging at 1 kHz during the same discharge Direct records of the coupled evolution of the source term and morphology during a single discharge
Wang et al. [70] Depressurization of water in a chamber — Water temperature and evaporated mass; modeling Gas discharge, evaporation, and changes in gas composition combined in one model and compared with water temperature and evaporated mass
Natural-circulation loop tests [71] Scaled natural-circulation water loop — Flow rate, void fraction, and temperature Periodic fluctuations recorded and related by the authors to flashing-induced acceleration, heat-exchanger condensation, and loop feedback
Mansour et al. [74] Water injection into a vacuum chamber 40-100 °C; back pressure 4-10 kPa High-speed schlieren imaging and image filtering Moving front surrounding the flashing jet, interpreted by the authors as a shock wave
He et al. [75] Rapid opening of a hot-water pipe end Initial pressure 0.35-0.7 MPa; DN50 pipe, 1.6 m long; rapid opening of the break Piezoelectric pressure transducers inside and outside the pipe, sampled at 20 kHz with a 50 μs sampling interval Depressurization, pressure undershoot, and external pulses recorded. Run36: initial pressure 0.7 MPa, subcooling 15.5 K, and plotted absolute-pressure peak approximately 0.94 MPa at 25 mm from the outlet. This is not a pressure difference across the front; the shock-wave attribution remains the authors’ interpretation
Zhang et al. [76] Straight pipe discharging to an atmospheric environment 1-8 MPa and 20-344 °C; subcooled water, two-phase vapor-liquid flow, and superheated steam Impingement-force measurements Total forces on circular and square plates varied with target distance, size, and jet state; a representative 400 mm square plate showed approximately 60% attenuation under matched operating conditions
Note: Studies are ordered by passage discharge, crack flow paths, near-field morphology, droplet size, downstream transport, transients, and impingement. Numerical values and geometric definitions follow the cited sources. Values read from plots, authors’ interpretations, and model estimates are identified separately; limits of comparison are discussed in Section 3.1, Section 3.2, Section 3.3 and Section 3.4.
Figure 6. Experimental water-jet droplet sizes reported in Table 3 of Rogóż et al. [49]. (a) Sauter mean diameter D32; (b) diameter Dv,90 at which the cumulative droplet volume reaches 90%. The effective single-orifice diameter is 150 μm, and the nozzle pressure difference is Δp = pinj − pa = 5 bar. Each temperature includes two independent ambient-pressure conditions, and Rp = psat(T)/pa uses absolute pressures. Rp = 1 is a thermodynamic reference rather than a universal breakup threshold. Values beside the points give droplet sizes; no interpolation or fitting is applied. No corresponding uncertainty values were provided for the four entries, so error bars are not shown.
Figure 6. Experimental water-jet droplet sizes reported in Table 3 of Rogóż et al. [49]. (a) Sauter mean diameter D32; (b) diameter Dv,90 at which the cumulative droplet volume reaches 90%. The effective single-orifice diameter is 150 μm, and the nozzle pressure difference is Δp = pinj − pa = 5 bar. Each temperature includes two independent ambient-pressure conditions, and Rp = psat(T)/pa uses absolute pressures. Rp = 1 is a thermodynamic reference rather than a universal breakup threshold. Values beside the points give droplet sizes; no interpolation or fitting is applied. No corresponding uncertainty values were provided for the four entries, so error bars are not shown.
Preprints 246046 g006
Table 3. Main experimental findings, scope of the evidence, and remaining gaps.
Table 3. Main experimental findings, scope of the evidence, and remaining gaps.
Physical question and sources Main findings Evidence type and scope Remaining gaps or limits of comparison
Mass flux and exit vaporization [20,32,33,35,93] The effective flow path and initial thermodynamic state jointly affect mass flux; local vapor content helps interpret the total mass flow rate Controlled short-tube comparisons, cold- and hot-condition crack flow rates, and observations of phase fractions and morphology in transparent tubes; BNL values reproduced from [93]; applicability is limited to the respective flow paths and inlet conditions Temperature, pressure, flow paths and reference cross sections for normalization differ across facilities; a unified mass-flux-phase-state relation has not yet been established
Crack flow paths and deformation under pressure [34,35,36,37,38,39] Loading changes geometry; the external opening area alone cannot explain flow rate; correcting the opening can improve predictions for the narrow axial slits examined Measurements before and after loading, comparisons across flow paths and cold/hot conditions, and controlled model comparisons; vaporization location is inferred indirectly from temperature, pressure and flow rate Roughness and hydraulic-scale effects are not fully separated; geometry and flow-rate evidence is insufficient to establish equivalence of the complete exit state
Near-field spreading and directional distribution [40,41,42,43,44,45,46,47] High superheat does not guarantee further widening of the spray angle; surfaces adjacent to the outlet, supply pressure and swirl alter spreading and reaction force Jet imaging, direction-resolved spray-angle measurements and reaction-force comparisons; some studies share the boundary condition of saturated-water discharge to atmosphere Outlet shapes, observation planes and liquid-supply histories differ; thresholds for jet spreading across different geometries have not been unified
Droplet size reduction and distribution shape [40,48,49] SMD decreases along both thermodynamic paths examined; pressure ratio alone cannot determine the distribution shape Glass-slide collection and centerline shadowgraph statistics; [40,49] use comparable SMD definitions, while [48] reports a characteristic diameter The glass-slide sampling position was not reported; inconsistent thermodynamic paths and sampling do not support a unified SMD range or pressure-ratio curve
Cooling and humidity response [55,56,57,58,59,60,63,64,65,66] Temperature reduction has distinct stages; characteristic locations and humidity responses carry information on discharge rate and flow trajectories Thermocouple temperature drops, qualitative thermal images, fixed-probe humidity and steam-generation efficiency; coverage includes low-temperature sprays and some high-temperature chamber conditions A temperature-drop inflection does not establish that phase change is complete; probe response and wetting affect readings; local cooling, steam generation and liquid carryover are different metrics, and thermal images have not provided precise phase-specific temperatures
Droplet sources and the fate of liquid [61,62,67,68] Breakup changes settling and jet reach; mixing steam with air can generate condensation droplets Droplet sizes in vacuum saline-water sprays, pilot-scale liquid collection from water releases, and observations of new droplets in steam-air flow constrain different processes A complete accounting of the fractions from each source and reaching each destination is still lacking for a single release; vacuum chambers and open-air releases have different boundary conditions
Time evolution of the source term [41,69,70,71] Inventory depletion changes both the source term and morphology; loop feedback can sustain periodic oscillations Pressure measurements, weighing and imaging during the same vessel blowdown event; loop measurements of flow rate, void fraction and temperature Mechanical and thermodynamic contributions depend on model interpretation; boundary conditions for chamber depressurization, loops and free jets are not interchangeable
Fluctuations in jet structure [42,72,73] Optical fluctuations are associated with spreading and liquid-core motion, reflecting changes in structures that obscure and scatter light Laser transmission in short-slit, short-orifice and swirling-flow experiments; reaction force is obtained from separate measurements Spectra of transmitted-light intensity fluctuations do not directly provide pressure or load spectra; the correspondence between local structure and loading response remains unestablished
Opening pulses and propagating structures [74,75] Moving density-gradient fronts and directly measured pressure pulses were observed separately during rapid releases Schlieren imaging of water injection into vacuum and piezoelectric pressure histories during rapid opening of a hot-water pipe end; the two datasets have different geometries and boundary conditions Wave-type identification still lacks joint constraints from propagation speed, pressure across the front and the state of the medium under the same operating conditions
Note: Evidence is classified as direct observation, indirect inference, or model comparison. The scope of each conclusion is constrained by the fluid, thermodynamic path, geometry, and statistical definitions.

4. Predictive Models and Validation for Flashing Jets

Validation targets for flashing models have changed as the scope of research has expanded. Critical-flow studies compare discharge rates and critical pressures; channel CFD examines pressure undershoot, vaporization onset and phase fractions; external-spray studies also assess droplet size, motion and thermal response. Studies differ in their observables, the datasets used to establish parameters and the independent cases used for comparison. The discussion below follows these comparisons to identify the conditions under which models account for observations and the outputs for which discrepancies remain.
The premixed steam-water experiments of Isbin et al. in 1957, Moody’s slip relation and the finite-rate model of Henry and Fauske were early developments in research on critical discharge [27,28,29]. In 1996, Downar-Zapolski et al. established a relaxation-time correlation using Moby Dick data [87]; subsequent CFD studies extended comparisons to local phase fractions, interphase heat transfer and bubble-population evolution [9,10,11,100,101,102,103,104,105,106]. The homogeneous relaxation model (HRM), two-fluid model (TFM), volume-of-fluid (VOF) method and population balance model (PBM) address phase-change response, the conservation-equation framework, interface representation and size statistics, respectively. These descriptions are combined in the HRM-VOF approach of Lyras et al. [112] and the TFM–PBM approaches of Liao and Lucas and of Li et al. [105,106] (Table 4).

4.1. Critical Discharge and Exit Conditions

Moody treated vapor-liquid slip under thermal equilibrium using the maximum-mass-flux condition [28], whereas Henry and Fauske used empirical relations to represent finite-rate interphase transfer [29]. Relative to HEM, which assumes both thermal equilibrium and equal phase velocities, these approaches emphasize slip and delayed vaporization, respectively. Validation has therefore focused on whether these treatments explain the observed differences in mass flux and critical pressure.
De Lorenzo et al. assembled more than 450 operating conditions and used the same database to compare equilibrium and delayed-equilibrium predictions for long tubes and short nozzles [77]. For the short-nozzle subset with subcooled inlets, the magnitude of the mean relative bias in mass flux was 36.25% for HEM and 5.74% for DEM. In the long-tube subset, HEM had a smaller mass-flux bias but retained a substantial critical-pressure bias (Table 7). These comparisons within a common database identify short nozzles with limited vaporization development as the main area of improvement for DEM. They also show that pressure and flow rate have different sensitivities to the closures; rough cracks introduce an additional frictional contribution.
After He et al. optimized DEM for slit flow, the critical-pressure error decreased on the same screened dataset, but the flow-rate error increased slightly [78] (Table 7). Xu et al. developed a critical-flow lookup table spanning the full operating range and implemented it in ATHLET, using a six-equation model that solves mass, momentum and energy separately for each phase [79]. Mass-flux errors against the Henry data nevertheless remained approximately 20-30% [80]. Both studies extended or improved the model description, but the benefits depended on the predicted quantity and inlet state, indicating the importance of local closures and flow-regime treatment.
In microcrack simulations, Zhao et al. used an interfacial energy balance to describe evaporation/condensation mass transfer. The flow rate for a representative circumferential crack was overpredicted by approximately 3.5%, less than with the classical cavitation-model combinations examined [81] (Table 7). Crack experiments also show that the opening under pressure, crack length and flow resistance affect the total leakage rate [34,35,36,37,38,39]. The improvement in the simulation therefore reflects the combined performance of the specified flow path and phase-change treatment, consistent with experimental evidence that geometry and thermodynamic state act together.
Kim proposed a choking correction that varies with the stagnation state [82]. Tesinsky implemented the Moody and Henry-Fauske relations in APROS and compared them with five Marviken tests, finding that the preferred discharge coefficient changed between the initial subcooled stage and the two-phase discharge stage [83] (Table 7). These studies show that classical relations with state-dependent corrections can still describe system-level discharge. The pressure, temperature and vapor content of the fluid inventory also make the corrections dependent on the discharge stage.
Xu et al. compared determinant and pressure-gradient criteria for choking. The two criteria converged in the cases examined when the magnitude of the pressure-gradient threshold was sufficiently large; the determinant method was also constrained by a compatibility condition at the critical point [84]. This study extends the explanation of critical-flow differences to numerical detection: in addition to phase-change and slip relations, the threshold and discretization affect the calculated mass flux.
Zhang et al. compared the effects of microcrack opening, length, wall thickness and cross section on thermal-hydraulic outputs [85]. Łapka et al. used an axisymmetric mixture framework coupled to the Zwart-Gerber-Belamri cavitation model (ZGBM) to compare velocity distributions in stepped and conical diverging sections [86]. These numerical studies characterize sensitivity to different flow paths; local velocities are model outputs in these comparisons. The metastable-liquid jet approximation of Heckmann et al. instead addresses short passages through thin walls [125], with a different geometric and physical focus from two-phase development and resistance in very narrow, long channels.

4.2. Phase Change and Two-Phase Flow in Channels

4.2.1. Phase-Change Rates, Nucleation and Thermal Feedback

The relaxation model of Downar-Zapolski et al., the source-term comparison of Karathanassis et al., and the nozzle simulations of Dang Le et al. and Liu et al. all relate pressure undershoot and vaporization development to finite-rate phase change [87,88,89,90]. These studies show that advancing or delaying vaporization changes pressure recovery and phase fractions. Differences arise mainly from the treatment of effective relaxation, interfacial mass transfer, nucleation onset and thermal feedback. Pressure, temperature and phase fractions provide complementary quantities for comparison.
Within the existing HRM framework, Downar-Zapolski et al. used Dx Dt = x eq − x τ to describe relaxation of the vapor mass fraction toward local equilibrium. They established a relaxation-time correlation from Moby Dick mass-flux, pressure and void-fraction data, then compared the model with water safety-valve data [87]. In this equation, xeq is determined by local pressure and mixture enthalpy, τ is an effective timescale combining nucleation and bubble growth, and x is the vapor mass fraction in the model. The main advance was to reproduce overall vaporization and the pressure distribution with a single finite-rate relation; size information remained implicit in the relaxation correlation.
Karathanassis et al. compared HEM, HRM, a kinetic-theory relation and ZGBM within a common-velocity framework. The kinetic-theory relation outperformed HRM for the benchmarks used, whereas the standard cavitation coefficients produced excessively rapid vaporization [88]. This controlled comparison attributes the differences primarily to the phase-change source term and shows how limited heat availability in hot water and latent-heat feedback affect near-isothermal cavitation relations.
For the BNL converging-diverging water nozzle, Dang Le et al. found that increasing either the accommodation coefficient or the interfacial pressure difference in a mixture model with slip advanced vaporization onset [89]. Liu et al.’s modified Lee model showed that the evaporation frequency changes the void fraction and pressure undershoot [90]. The latter study used evaporation and condensation frequencies of 20 s−1 and 0.1 s−1 for several conditions, but used 10 s−1 and 25000 s−1 for RUN291 (Table 7). Such variation within one facility shows that the phase-change response must be interpreted in the context of the specific test and model combination. The Lee frequencies serve as closure coefficients rather than fixed material constants.
Dang Le et al. combined slip, an accommodation coefficient and an interfacial pressure difference in their BNL model [91]. Le coupled Hertz-Knudsen-Langmuir-type mass transfer to a simplified thermodynamic equation for Moby Dick simulations [92]. Jin et al. compared cold-water cavitation with hot-water flashing, including both pressure-driven and Lee-type thermal phase-change source terms in the hot-water calculations [93]. Despite using different source terms, all three studies showed that latent-heat cooling feeds back to the driving force for vaporization through temperature and saturation pressure.
Narayanan’s compressible multiphase simulations showed that changes in the treatment of latent heat, saturation pressure and specific heat can alter downstream void fraction and pressure recovery even when mass flow rates are similar [94]. Consistent with the thermal-feedback studies above, this result attributes local prediction differences to the combined effects of properties, phase-change source terms and energy treatment. Adjustments to empirical frequencies may also compensate for simplified properties or energy treatment.
Yin et al. used explicit nucleation treatment to distinguish vaporization onset from subsequent growth and compared predictions of mass flux, pressure and void fraction with data [95]. Ding et al. coupled a nonhomogeneous equilibrium formulation to the Lee relation for discharge across a large pressure drop through an AP600 orifice plate. Their predicted exit flow quality was close to the experimental value, whereas the mass flow rate was substantially overpredicted [96] (Table 7). These studies refine vaporization modeling at different levels and show that different outputs respond differently. Ding et al.’s description of temperatures approaching saturation refers to the thermodynamic state within the calculation.
Mat et al. applied HRM to BNL RUN309 and RUN362. The mass flow rate for RUN309 was close to the measured value, but pressure recovery in the diverging section remained underpredicted [97] (Table 7). Subsequent extensions to lower inlet pressures and subatmospheric back pressures showed sensitivity to relaxation and trends with the model parameters. Experimental comparisons in the study were confined to the BNL tests; the additional low-pressure cases were numerical investigations. These two parts therefore address observed behavior and predictions awaiting validation, respectively.

4.2.2. Phase Motion and Evolution of Interfacial Scales

Liao et al.’s one-dimensional five-equation microchannel model assumed metastable liquid and saturated vapor. Its mass-flux accuracy was broadly comparable to that of a six-equation model, but the respective numerical divergence rates were 1.3% and 16% [98]. Yin et al. also improved pressure predictions by restructuring the closures for bubbly and annular flow and smoothly connecting them through the churn-flow region [99]. These studies relate improvements in mass-flux accuracy, stability and pressure prediction to assumptions about flow regime and energy, showing that simplified models can provide useful predictions within their applicable ranges.
Liao and Lucas compared heat-transfer relations for stationary bubbles, translating bubbles and bubbles in turbulent flow, examining the contributions of conduction, relative motion and turbulence, respectively [100]. Liao et al. subsequently tested mechanistic closures against single-bubble growth, vapor-bubble condensation in subcooled water and TOPFLOW data, the latter at 20 bar and 6 K subcooling [101]. Li et al. used interface-resolved calculations with the bubble position fixed and growth suppressed to isolate the heat-transfer effects of deformation and oscillation [102]. These studies progressively refine heat transfer per unit interfacial area; bubble number and interfacial-area evolution are addressed by the dynamic size models discussed below.
Both the nozzle IATE simulations of Li et al. [103] and the review of flashing CFD by Liao and Lucas [104] link transfer area to phase change and interphase exchange. IATE transports interfacial area per unit mixture volume, whereas PBM describes bubble populations using size classes or moments of the size distribution. Both can incorporate nucleation, expansion, coalescence and breakup. The spherical-bubble size relation used by Li et al. can be written as a i = 6 α d 32 , where ai is the interfacial area concentration, α is the void fraction and d32 is the Sauter mean diameter of the bubble population. This relation connects vapor volume to transfer area under the geometric assumption of dispersed, approximately spherical bubbles.
Liao and Lucas used CFD-PBM to describe bubble formation, growth, coalescence and migration in TOPFLOW [105]. Li et al. then compared four operating conditions and found that adding turbulent heat transfer and coalescence–breakup improved the previously underpredicted bubble diameters and void fractions [106]. Li et al.’s nozzle IATE study also predicted vaporization onset reasonably well [103]. These developments extend validation of size evolution from the total amount vaporized to bubble diameter, radial phase fractions and the spatial location of onset. Local observations thus begin to reveal the combined effects of heat transfer and population evolution.
John and Lange first used normalized critical nucleation work to constrain finite-rate evaporation and defined separate diameters for heat transfer and momentum exchange [107]. They subsequently introduced the number of molecules in a cluster and a volume-fraction threshold for mass transfer through a bulk-nucleation model, improving some saddle-shaped profiles and downstream centerline vapor distributions [108]. Both studies connect nucleation modeling with spatial phase distributions. Discrepancies in near-throat radial profiles persisted, indicating that phase migration and local flow also contribute to these profiles.
Liao and Lucas noted that a fixed bubble diameter has difficulty describing both vaporization onset and the developed phase distribution [104]. Their simulation of a natural-circulation riser, driven by measured boundary-condition histories, reproduced alternating evaporation and condensation but predicted flashing onset too late, underestimated the evaporation rate and overestimated the pressure drop [109] (Table 7). This result extends the discussion of dynamic scales and phase-change response to local riser behavior in natural circulation. The different boundary conditions in circulating loops and free jets define the extent of the connection between these studies.
Existing studies use IATE and PBM to describe the area and size evolution of dispersed bubbles [103,104,105,106], and VOF to represent liquid cores, films and ligaments that the grid can resolve [112]. Flow-regime-dependent two-fluid closures also address bubbly, churn-turbulent and annular flow [99]. The morphological scales observed or predicted differ across these studies; continuous interfaces, smaller dispersed structures and unresolved breakup therefore play different roles in the models.
The nozzle studies of Downar-Zapolski, Dang Le, Jin and colleagues mainly compare vaporization histories using pressure and phase-state data [87,88,89,90,91,92,93,94]. The TOPFLOW studies of Liao, Li and colleagues also use bubble diameter and void fraction to examine transfer area [105,106]. Figure 7 accordingly distinguishes effective phase-change response from interfacial-area effects and shows how local size observations complement evidence from total mass flow rate and pressure.
Meller et al.’s multifield study treated the coexistence of bubbles, microbubbles and large interfaces within one framework [110]. They subsequently adapted momentum exchange to the degree of interface resolution and assessed performance for bubble rise and stratified gas-water flow [111]. These studies advance the computational connection between dispersed phases and continuous interfaces. Validation has focused on morphology-adaptive hydrodynamics; phase change and breakup in high-temperature flashing require an additional level of evidence for subsequent applications.

4.3. External Jets and Droplet Heat and Mass Transfer

The plume simulations of Calay and Holdø show that exit phase state, velocity and size are important inputs to external transport [31]. Subsequent studies follow two approaches: one connects internal vaporization to primary droplet formation, while the other calculates evaporation, cooling and condensation for a prescribed droplet population. Droplet size and velocity test the former processes, and temperature and evaporation rate test the latter. The findings are therefore compared in terms of initial size and subsequent heat and mass transfer.
Lyras et al. combined HRM, a compressible pressure equation and VOF in FlashFOAM to connect the internal channel to the external jet [112]. Their subsequent interfacial-area-density method reproduced the decrease in water SMD with increasing temperature, with measured and calculated decreases of approximately 33% and 43%, respectively. Joint comparisons of velocity and SMD were made for R134a [113] (Table 7). Razzaghi’s aerodynamic–thermal breakup model also linked the water-droplet size distribution to early bubble growth, with larger discrepancies at low superheat [115]. These studies make primary droplet sizes and their formation mechanisms direct subjects of comparison.
Guo and Zhu modified a lumped heat capacity model using an effective thermal conductivity model as a reference, improving agreement of the mean droplet temperature with that model and experiments [114]. Cai et al.’s upward-spray model jointly solved for motion, size and temperature [117], while their diffusion-controlled seawater model related chamber pressure, flow velocity and salinity [118]. Together with Razzaghi’s finding that droplet size is sensitive to bubble growth [115], these studies show that cooling histories reflect both initial size and internal droplet thermal resistance. The relationships among temperature, droplet size and the amount evaporated provide a basis for comparing the findings of different models.
Hosseini Araghi et al. compared both centerline temperature and evaporation rate for low-temperature saline-water sprays [116]. In experiments and CFD with active vapor extraction, Guo et al. reported a difference of approximately 7.5–7.7 K between the mean vapor and residual-liquid outlet temperatures [119] (Table 7), directly supporting substantial thermal nonequilibrium under those conditions. Initial droplet sizes and velocities in the latter study were calibrated beforehand as a function of liquid temperature under indoor conditions at atmospheric pressure. The experimental–numerical comparison therefore primarily characterizes the temperature and evaporation response of a prescribed spray.
For the desalination conditions examined at salinities no greater than 10%, Guo et al. found that neglecting internal droplet salinity variations usually changed the evaporation rate by less than 5%; diffusion became more influential at higher salinities [120]. Zhang and Liu’s simulations of a high-temperature, high-pressure tank predicted cooling to 373 K in approximately 6 ms under the specified spray and vessel conditions [121]. Compared with the vacuum-spray data [116,117,118,119], the cooling or equilibration times in these studies correspond to different droplet sizes, salinities and pressure boundary conditions, demonstrating the dependence of thermal response on system conditions.
The steam–air measurements of Lim et al. and the turbulent-condensation model of Burluka describe new droplet formation in the mixing layer [25,26], while the plume simulations of Calay and Holdø emphasize the influence of source droplet size and velocity on downstream dispersion [31]. Prescribed-spray models describe evaporation and cooling of existing droplets, whereas gas-mixing and condensation studies describe newly formed liquid water. Together, they provide a physical account of liquid-water sources and vapor–liquid partitioning in plumes. Validation against common measurements of streamwise liquid-water flux remains necessary to connect these descriptions.

4.4. Validation Coverage and Use of Data

4.4.1. Progress from Discharge Rates to Local Structure

The critical-flow database assembled by De Lorenzo et al. [77], the lookup-table comparisons of Xu et al. [80] and Tesinsky’s Marviken validation [83] provide relatively systematic coverage of mass flux and pressure. BNL and TOPFLOW studies progressively add comparisons of vaporization onset, phase fractions and bubble diameter [89,90,103,105,106], while spray and transient experiments extend coverage to transport and loading [75,76,113,119]. Table 5 summarizes the quantities and modeling approaches actually compared with experiments. The most extensive data concern overall discharge; local structure and downstream processes are mainly covered by separate experiments.
Observations from different facilities have led model development in different directions. The comparisons of De Lorenzo et al., Xu et al. and Tesinsky assess overall mass flux and pressure [77,80,83]. The BNL studies of Dang Le et al., Liu et al. and Li et al. track pressure undershoot, vaporization onset and phase fractions [89,90,103], while TOPFLOW adds information on bubble diameter and population evolution [105,106]. Lyras et al. and Guo et al. compare spray size and motion, and thermal response, respectively [113,119]. This extension from integral quantities to local distributions provides increasingly specific observational support for nucleation, heat transfer and migration.
Shared benchmarks connect these developments. Downar-Zapolski et al. used Moby Dick data to establish a relaxation relation [87], and Le used data from the same facility to analyze thermal feedback [92]. BNL data have been used repeatedly in studies of different closures, and the TOPFLOW studies of Liao and Lucas and of Li et al. also reuse some tests [105,106]. Different models can thus be assessed against common observations, but the number of publications is not the number of independent experimental sources. Table 6 identifies the data sources and their use, while Table 7 reports each study’s results and discrepancies, distinguishing parameter determination, reproduction of the same data and comparisons with independent conditions.
Table 7. Assumptions, comparison results and validation limits of representative models.
Table 7. Assumptions, comparison results and validation limits of representative models.
Model or combination Basic assumptions Validation or comparison cases Main results and deviations Validation limits
HEM Equal vapor and liquid velocities; local thermodynamic equilibrium More than 450 long-tube, short-nozzle and slit conditions assembled by De Lorenzo et al. [77] Super Moby Dick long-tube subset with subcooled inlets: tabulated mean relative bias magnitudes of 5.84% for mass flux and 25.42% for critical pressure; short-nozzle mass-flux bias 36.25% Overall mass flux near equilibrium can serve as a benchmark; the equilibrium assumption alone does not resolve delayed vaporization in short nozzles or friction in rough slits
Moody / Henry–Fauske Moody treats slip using thermal equilibrium and maximum mass flux; Henry–Fauske uses empirical relations for finite-rate transfer Five Marviken tests in APROS [83] A discharge coefficient of 0.75 performs better during the two-phase stages examined; 1.0 is more appropriate for the initial subcooled stage Coefficients in both classical relations depend on the discharge stage and calibration range
DEM Divides liquid into metastable and saturated components and describes delayed equilibration through a vaporization-development relation Short-nozzle subset with subcooled inlets in the De Lorenzo database [77] Super Moby Dick: tabulated mean relative bias magnitudes of 5.74% for mass flux and 10.85% for critical pressure Improvement over HEM is established for a subset of the same database; it does not directly represent arbitrary cracks or other fluids
Optimized slit-flow DEM Optimizes local delayed-equilibrium closures The same screened slit dataset [78] Mean absolute relative error in critical pressure: 34.20%→11.83%; flow-rate error: 5.82%→6.25% Improved pressure prediction does not also reduce flow-rate error; conclusions apply to the screened data used for optimization
R134a slit-flow DEM Recalibrates phase-change coefficients and the boiling-pressure ratio R134a slit experiments [124] Most relative volumetric-flow-rate deviations lie within ±20%; most signed mean relative biases in streamwise pressure lie within ±15%; all use the experimental quantity as the denominator Systematic volumetric-flow-rate bias remains for the 0.6 mm slit at subcooling <10 K; validation concerns the recalibrated combination, not transfer of the original parameters to another fluid
HRM Approaches equilibrium over a finite relaxation time, Dx Dt = x eq − x τ Moby Dick and water safety-valve tests [87]; BNL RUN309, RUN362 and numerical extension to low back pressure [97] BNL RUN309: calculated mass flow rate 8.5 kg/s versus measured 8.9 kg/s; diverging-section pressures are underpredicted for both RUN309 and RUN362 [97] τ represents an effective phase-change response; the additional inlet ranges of 350–380 K and 110–200 kPa, and outlet range of 20–50 kPa, lack corresponding experiments
Six-equation two-fluid model and critical-flow lookup table Solves phase mass, momentum and energy separately; the lookup table includes flow-regime treatment Underlying six-equation model [79]; Henry and Marviken data [80] Mean absolute relative mass-flux error for the 19 Henry tests: 24.51%; subcooled subset: 28.94%; saturated subset: 19.59% Additional phase-specific variables do not automatically ensure engineering accuracy; pressure predictions for saturated inlets still require independent assessment
Two-fluid evaporation / condensation Eulerian–Eulerian two-fluid model with mass transfer determined by an interfacial energy balance Artificial-microcrack experiments [34,38] used as reference data in [81] Circumferential crack: opening 0.13 mm, length 8.3 mm, depth 1.01 mm; inlet approximately 7.10 MPa and 434 K, discharge to atmosphere: measured 236.30 kg/h, calculated 244.57 kg/h, approximately +3.5%; classical cavitation combinations approximately +4.66%–+8.40% Supports the total leakage rate for the microcrack examined; the flow-rate comparison does not independently validate geometry under pressure or the local phase state
Mixture with slip / modified Lee Slip, accommodation coefficient and interfacial pressure difference, or evaporation / condensation frequency closures BNL converging–diverging water nozzle [89,90] Comparisons cover mass flow rate, pressure and selected void fractions; several cases in [90] use evaporation 20 s−1 and condensation 0.1 s−1, RUN291 uses 10 s−1 and 25000 s−1, and RUN353 favors evaporation 10 s−1 Near-throat radial distributions retain discrepancies; one frequency pair does not cover every condition, and the frequencies are not fixed material parameters
Nonhomo geneous equilibrium–Lee Couples a nonhomogeneous equilibrium formulation to the Lee mass-transfer relation Large-pressure-drop discharge through an AP600 orifice plate [96] Design point: calculated mass flow rate 144.9 kg/s versus experimental 120 kg/s; calculated exit flow quality 48.6% versus experimental 47.1% Close agreement in flow quality does not ensure flow-rate accuracy; proximity to saturation temperature describes the calculated state, not an error assessment against measured temperatures
IATE / PBM Interfacial area transport or population balance with source terms for size evolution Nozzle vaporization onset [103]; TOPFLOW depressurization series [105,106] Bubble diameter and void fraction are underpredicted with wall nucleation and phase change alone; adding turbulent heat transfer and coalescence–breakup improves predictions [106] Mainly supports dispersed-phase area and size evolution; the contributions of different source terms depend on local observations and model configuration
Natural-circulation phase-change CFD Solves two-phase flow and phase change in a natural-circulation riser driven by measured boundary-condition histories Evaporation–condensation in a natural-circulation riser [109] Reproduces alternating evaporation and condensation; evaporation is underpredicted, flashing is delayed and pressure drop is excessive Tests only the riser response driven by experimental boundaries; prescribed outlet pressure is not an independent validation quantity, and full-loop feedback is not computed independently; extrapolation to free jets still requires validation
Unified flashing–atomization Channel–jet coupling with interfacial area density treatment Water SMD trend with temperature; R134a velocity/SMD [113] Water nozzle at 3 bar, 50 mm downstream: for 110→115 °C, measured SMD decreases by approximately 33% and calculated SMD by approximately 43% The water trend is overpredicted in magnitude; appreciable discrepancies remain in near-axis R134a velocity and SMD; direct validation quantities differ by fluid
Heat and mass transport CFD for a prescribed spray Uses precalibrated droplet sizes and velocities as initial inputs and accounts for active vapor extraction Flashing experiment at 94 °C, 40 kPa and 44.1 mL/s [119] Experimental evaporation rate 4.19 kg/h, vapor 357.9 K, residual liquid 350.2 K; calculated values 4.30 kg/h, 357.4 K and 349.9 K Temperature and evaporation rate jointly support the prescribed-spray thermal response; initial sizes and velocities were precalibrated as a function of liquid temperature indoors at atmospheric pressure, without validating primary sizes under the flashing conditions
Mixture–ZGBM geometry simulations Axisymmetric mixture framework with the Zwart–Gerber–Belamri cavitation relation Numerical comparison of stepped and conical diverging sections [86] Different velocity distributions obtained over throat diameters of 0.62-0.82 mm, absolute inlet pressures of 0.5-0.7 MPa and subcoolings of 1-50 K Provides calculations of geometric sensitivity; local velocity is a model output, not independent experimental evidence of accuracy
Note: Deviations retain the predicted quantities, error definitions and comparison conditions of the original studies. In [77], μ is the signed mean relative bias; its magnitude |μ| is not the mean absolute relative error. Averaging ranges and calibration status differ, so the values report the results of individual studies. Direct comparisons require common data and consistent definitions.

4.4.2. Parameter Variation and Results Across Operating Conditions

In BNL studies, Dang Le et al. and Liu et al. found that changing phase-change intensity altered onset, pressure undershoot and void fraction [89,90]. In TOPFLOW, Li et al. found that heat transfer and coalescence–breakup jointly changed bubble diameter and void fraction [106]. These results show that different closures can increase vaporization through different mechanisms while producing different sizes, superheats or radial distributions. The nucleation studies of John and Lange used an isothermal approximation and parameters selected as a function of temperature [107,108]. Improvements in spatial distributions apply to that combination; performance with fixed parameters and full energy coupling remains to be assessed.
Du et al.’s spatiotemporal tomography provides time-resolved three-dimensional fields averaged over repeated injections [51], while structured laser illumination planar imaging with two phase-shifted patterns (2phase-SLIPI) reconstructs the mean structure at a specified time, layer by layer [52]. Qiu et al. combined SLIPI using three phase-shifted patterns with laser-induced exciplex fluorescence/Mie scattering (LIEF/Mie) to obtain cycle-averaged planar SMD [53]. These diagnostics extend the structures and sizes available for model comparison, but use different averaging procedures, spatial sampling and size weightings. Measurement statistics therefore also contribute to discrepancies between calculations and experiments.
In the two-phase water-turbine simulations of Rane and He, substantial power discrepancies persisted at low rotational speeds after the closures were established at the design point. Subsequent simulations of a modified design retained thermal nonequilibrium phase-change treatment but did not eliminate this discrepancy [122,123]. The turbine studies illustrate the difference between a calibration point and other operating conditions, providing indirect evidence of parameter dependence in flashing closures. Their relevance to crack and nozzle studies is limited to phase change and calibration.
He et al. applied DEM to R134a slit flow and readjusted the phase-change coefficients and boiling-pressure ratio. Most predictions of volumetric flow rate and streamwise pressure improved, but systematic discrepancies persisted for narrow slits at low subcooling [124] (Table 7). Compared with the water-slit studies, this work provides experimental assessment of a recalibrated model combination for another fluid and identifies narrow slits at low subcooling as a region of persistent error.
Critical-flow, channel and spray studies now support model comparisons at several levels. Comparisons of discharge rates are the most systematic; nonequilibrium and dynamic size models progressively account for pressure, phase fractions and bubble diameter; primary-droplet and transport studies connect size, motion and thermal response. Table 5, Table 6 and Table 7 summarize these developments and their data sources. Evidence for phase-specific exit velocities, radial structure and streamwise vapor–liquid partitioning remains fragmented. These are the main gaps in extending local models to the complete leakage process.

5. Engineering Consequences of Leakage and Monitoring Methods

Kong et al. [3] reviewed experiments, engineering models, and computational fluid dynamics studies of jet impingement in high-energy piping systems. Kim et al. [126] and Tian et al. [127] examined leak detection using a humidity sensor and ventilation condensate, respectively. These studies link the mass, energy, and momentum released during flashing leakage to different engineering consequences: the source term specifies the release rates, jet spreading and the geometry of the loaded surface affect load distribution, and ventilation and sampling affect monitoring signals. This section compares thermal and humidity monitoring, mechanical effects, and their links to safety analysis in terms of the engineering quantities actually measured or predicted in each study.

5.1. Temperature and Humidity Fields and Monitoring Signals

Through experiments and numerical simulations of steam entering air, Kim et al. [68] investigated the decay and spreading of velocity and temperature fields, together with the associated condensation, at different flow rates. Lim et al. [25] used a phase Doppler particle analyzer to measure peaks in droplet number concentration and liquid water content at the edge of the transition region, followed by a downstream decrease in concentration. The two studies reveal the coupling between mixing and phase change through the flow field and the droplet population, respectively. Temperature reflects energy exchange, liquid water measurements reflect droplet transport, and relative humidity depends on both temperature and water vapor partial pressure. Together, these three types of signal help explain the evolution of the temperature and humidity fields.
Burluka [26] developed a condensation model for a saturated steam jet entering cold air and compared it with phase Doppler measurements. In the far field examined in that study, condensation, evaporation, and droplet coalescence were all weak, and the droplet size distribution remained approximately unchanged. Considered alongside the finding by Lim et al. [25] that the decrease in liquid water content downstream of its peak was associated with mixing, the concentration decrease at this stage mainly reflects dilution and does not necessarily indicate continued vaporization. High-temperature water leaks also contain droplets formed at the source. Their evaporation and settling make the relationship between signal and flow rate dependent on both the phase state at the outlet and transport through the surroundings.
Busov et al. [59] separately conducted visible-light photography and infrared observations of superheated water jets issuing from short orifices. With a fixed emissivity setting, they obtained apparent temperature distributions that varied with jet morphology. Trofimov et al. [60] used optical-path experiments to compare the effects of liquid water and droplet-laden steam on readings in different infrared bands, providing optical information relevant to the interpretation of such images. These results show that spectral band, optical path, and obscuration affect temperature interpretation from plume images, whereas equipment surface temperature, heat flux, and exposure duration directly characterize the thermal effects on equipment.
Kim et al. [126] measured response and recovery times of approximately 16 s and 15 s, respectively, for a fiber-optic humidity sensor during controlled humidity switching at room temperature. The timing endpoints were defined by the 10% and 90% levels of the optical intensity change. Tian et al. [127] modeled containment ventilation and coolers. For a 1 gpm leak into the reactor pit, condensation began after approximately 72 min for the hot-leg case and 79 min for the cold-leg case. The sensor measurements characterize device dynamics, whereas the calculations characterize steam transport and condensation onset in a specific system. These are different stages of the detection chain; system alarm delay also includes sampling and signal classification time.
Liu et al. [128] tested an improved background subtraction algorithm using steam leakage videos from nuclear-grade valve test facilities. Lee et al. [129] trained bidirectional long short-term memory networks on numerical simulation data for sampling tubes to predict relative humidity in the leakage region. These studies use leakage signals through video recognition and humidity mapping, respectively. The former tests plume recognition in videos, whereas the latter trains and predicts humidity under simulated conditions. Their reported performance is therefore tied to their respective data sources and test settings. A complete field system must also address detection probability, false alarms, and delay during continuous operation.
Lee et al. [130] compared reflectors and acoustic guides in outdoor nitrogen leakage tests. Choi et al. [131] used rigid acoustic guide tubes within insulation to improve signal acquisition in compressed-air tests, with discrimination based on the frequency center of gravity and the signal-to-noise ratio. Together, these studies show that improving the propagation path from an obscured leak location to the sensor can strengthen the acoustic signal. The evidence mainly concerns gas leakage. Applications to high-temperature water also involve acoustic sources associated with phase change, propagation through two-phase media, and operating background noise. Improved signal acquisition in gas test facilities and identification of water leakage signals therefore require different stages of validation.
These studies provide complementary observation methods: humidity and condensate track steam transport, video reveals plumes in exposed regions, and acoustic guides improve signal acquisition at obscured locations [126,127,128,129,130,131]. Studies of devices, transmission, and recognition describe different stages of the detection chain. The capability of a complete system is characterized jointly by the minimum detectable leak rate, detection probability, false-alarm rate, and alarm delay. The engineering review examples in Section 5.5 relate these stages to system performance under the anticipated leakage conditions.

5.2. Jet Reaction Force and Target Impingement Force

In hot-water discharge experiments using Laval nozzles, Gorelik et al. [132] jointly measured flow rate, static pressure, and jet reaction force, and used these measurements to infer the mean outlet velocity. Zhang et al. [76] measured total impingement force on downstream targets of different sizes. The former measurements constrain the axial momentum released at the outlet, whereas the latter constrain momentum exchange when a finite target intercepts the spreading jet. The distinction between the two experimental configurations shows that jet reaction force, target center pressure, and total impingement force describe different parts of the process. Figure 8 summarizes the relationships among these quantities.
Force definitions in the literature also depend on the boundaries of the apparatus. In a model with a large planar outlet flange, Avdeev [136] separated the jet reaction force from the resultant pressure force on the flange to explain the decrease in net source load during radial spreading. Charrouf et al. [139] considered downstream equipment and analyzed the pressure history and propagation of the pulse generated at opening. Outlet momentum transport, pressure on adjacent surfaces, and pressure on the target therefore contribute to different load quantities. Figure 8 uses a fixed control volume with a closed upstream end and no inlet, integrates the local phase momentum fluxes and gauge pressure over the outlet area, and retains momentum accumulation within the control volume. The net source load shown includes the effects of the internal fluid and uniform external ambient pressure, but excludes support reactions. The resultant pressure force on a finite target is the area integral of the actual pressure difference between its front and back faces.
In comparisons involving short slits and surfaces adjacent to the outlet, Reshetnikov et al. [42] and Pavlenko et al. [45] observed a decrease in jet reaction force when the jet became fully spread. In the configuration used by Reshetnikov et al. [44], the force changed continuously. These results involve different adjacent surfaces and supply conditions, showing that the relationship between morphology transition and reaction force depends on the boundaries of the apparatus. Gorelik et al. [132] provided a further momentum constraint by inferring outlet velocity from combined measurements of static pressure, flow rate, and reaction force. Compared with flow-rate measurements alone, combined force and pressure data connect changes in reaction force to the outlet state and the effects of adjacent surfaces.
Zhang et al. [76] compared circular and square plates of different sizes in straight-pipe discharge experiments. At 1 MPa and 112 °C, with a pipe diameter of 4.8 mm and a length-to-diameter ratio of 55, the total force on the 400 mm square plate decreased by approximately 60% as the stand-off distance increased to about 125 pipe diameters; the force on the 70 mm circular plate decreased more rapidly. This comparison of target sizes shows that, as the jet spreads, the intercepted fraction decreases more rapidly for a smaller target. A broader footprint and a lower total force can therefore occur together. Differences in resultant pressure force between concentric circular targets of different radii can be interpreted as annular loads only when the pressure difference is approximately axisymmetric and changes in target size do not significantly alter the pressure field.
Kong et al. [133] compiled historical jet experiments for different inlet phase states and compared critical mass flux, core dimensions, and centerline pressures in free and impinging jets. Their subsequent study [134] used relatively small-break data to revise the core-size and pressure relations, yielding generally conservative center stagnation pressures for the subcooled-water and saturated-water/two-phase conditions examined. The target-size comparisons by Zhang et al. [76] add information on finite loaded areas. These two types of study support assessments of local loading intensity and interception by the entire target, respectively. Both the center-pressure correlation and the radial load distribution determine how a local pressure estimate translates into total force.
Yuasa et al. [135] defined the visible jet boundary using a 50% time-averaged occupancy threshold, determined the asymptotic width and distance from inflection points in the outline, and related these quantities to mass flux and enthalpy. The experiments covered absolute pressures of 0.4-1.9 MPa, nozzle diameters of 9.2 or 16.1 mm, and subcooling of 0-20 K; computational fluid dynamics extended the range to pressures as high as 7 MPa. The authors reported a difference between the region occupied by the visible white mist and a region defined by loading, showing that comparisons between region models also depend on the boundary definition. The study describes the spatial extent of the jet, whereas local pressure, heat flux, and exposure duration determine the specific engineering consequences within that region.

5.3. Transient Pressure and Structural Dynamic Response

He et al. [75] measured external pressure histories during rapid opening of the end of a hot-water pipe. In water injection experiments in a low-pressure chamber, Mansour and Müller [74] used schlieren imaging to record a moving front surrounding the jet and interpreted it as a shock wave. The pressure measurements describe temporal variation, whereas the images describe spatial propagation of the front, providing complementary information on the opening stage. Identifying a particular moving front as a shock wave also requires consideration of wave speed, pressure across the front, and the state of the medium under the same conditions. Separately obtained pressure histories and schlieren images therefore serve different evidential roles.
Avdeev [136] used a boiling-discontinuity model to analyze releases through orifices and short nozzles near the superheat limit, relating radial expansion and wave structures to forces at the source. The wave-structure comparisons included existing isooctane data. The reaction-force analysis used a configuration with a large planar outlet flange, calculated the jet reaction force and the resultant flange pressure force separately, and attributed the decrease in net load to pressure acting on the adjacent surface. The study offers a physical explanation for anomalous reaction forces while showing that the working fluid, degree of superheat, and surface adjacent to the outlet are part of the conditions needed to interpret such load results.
Mansour et al. [137] computed wave structures in a flashing jet inside a water vapor chamber initially at approximately 1 kPa and 280 K, using a vessel boundary with an inlet only. Alekseev et al. [138] examined initial conditions inside a pipe at a supercritical pressure of 23 MPa and temperatures of 370 °C or 380 °C. The external medium was a steam–water mixture at 0.101 MPa with a vapor mass fraction of 0.5; the two initial temperatures were below and above the critical temperature of water, respectively. Both simulations address wave propagation through steam–water media. However, their initial media and vessel boundaries differ from the actual openings and reflection conditions in a building containing air, so their results apply to the propagation problems specified in each study.
Charrouf et al. [139] used three-dimensional transient CFD to establish correction factors for a pressure vessel burst correlation, enabling pressure loads from steam-line rupture to be evaluated for multiple break locations. The method accounted for wave reflections, target shape, and the surrounding geometry, providing pressure distributions for structural assessment. The relationship between pulse duration and the relevant structural periods determines how these loads should be represented. When the positive phase is sufficiently short, its effect can be approximated using the spatial distribution of positive-phase pressure impulse, defined as the time integral of overpressure in Pa·s. The subsequent structural response depends on this distribution and the equipment’s modal properties. As the load duration becomes comparable to a relevant structural period, the pressure history must be retained to evaluate the response.
For sustained jet loading, Charrouf et al. [139] examined whether feedback between the jet and the target could maintain resonance. They identified nonequilibrium steam condensation, varying separation between the pipe outlet and target, oblique impingement, uneven surfaces, and frequency mismatch as factors that disrupt the phase locking required for resonance under the conditions considered. Assessment of this stage therefore requires the mean load and the frequency content of its fluctuations to be considered alongside the structural natural frequencies and damping. Applying these conclusions to flashing hot-water releases requires comparison of the discharge conditions, phase composition, target geometry, and structural time scales.

5.4. Sources of Error in Engineering Predictions

In a leak-before-break benchmark with common inputs, the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD NEA) [140] compared leak-rate calculations for a fixed crack morphology and length. Differences in crack opening displacement explained most of the differences in flow rate, with crack-face pressure and weld residual stress also contributing. The finite-target experiments of Zhang et al. [76] reveal the effects of target size and intercepted fraction, while Kim et al. [126] and Tian et al. [127] describe device dynamics and system transport times, respectively. These three types of evidence show that source-term, mechanical-load, and leak-detection predictions have different dominant sources of error. Improvements in accuracy therefore depend on the quantity being evaluated.
Table 8 draws on the source-term, loading, and leak-detection studies discussed above to compare the factors and evaluation quantities associated with each engineering response. The NEA benchmark [140] mainly links crack geometry under pressure to leak rate, target and propagation studies [76,139] link jets to mechanical effects, and humidity and condensate studies [126,127] link transport through the surroundings to detection signals. Although mass, energy, phase state, and momentum provide a common physical basis, each study addresses a different stage leading to the final response. Errors in source-term, external-field, and response models therefore contribute in different ways.

5.5. Engineering Practice and Applicable Criteria

The General Design Criteria of the U.S. Nuclear Regulatory Commission (NRC) set requirements for equipment protection and leak detection [141]. Criterion 4 of Appendix A to 10 CFR Part 50 addresses dynamic effects such as pipe whipping and discharging fluids, while Criterion 30 addresses coolant leak detection and, as far as practical, identification of the leak location. The former requirements relate to mechanical loading and the region in which equipment is affected; the latter relate to the complete detection system. Dynamic effects of postulated pipe ruptures may be excluded only when an analysis reviewed and approved by the NRC demonstrates an extremely low probability of the corresponding rupture under conditions consistent with the piping design basis. The specific scope is determined by the licensing basis of the unit.
The International Atomic Energy Agency (IAEA) Safety Guide SSG-64 [142] recommends evaluating the spatial and temporal distributions of jet geometry and physical parameters, considering mechanical and thermal effects as well as consequences of electrical conduction through liquid water, and, where necessary, incorporating the effects of room conditions on equipment function into environmental qualification. Analysis may use appropriate, verified computational models, simplified approximations based on experiments, or justified conservative assumptions. Existing studies address different parts of this assessment: Zhang et al. [76] measured the total force on finite plates, Kong et al. [134] provided conservative center pressures for the conditions examined, and Yuasa et al. [135] extended the predicted affected region through experiments and simulations. These studies add information on interception over an area, local pressure, and spatial extent, respectively. Maintaining equipment function also depends on loaded area, release duration, and environmental boundary conditions. Local validation and justified conservative assumptions together support a complete consequence assessment.
In its safety evaluation for Watts Bar Unit 2 [143], the NRC concluded that the diverse leak-detection systems for the reactor coolant pressure boundary provided reasonable assurance of timely detection of identified and unidentified primary-coolant leakage, met the requirements of General Design Criterion 30, and conformed to the relevant guidance in RG 1.45 Rev. 1 for leakage detection and identification. This is an acceptability conclusion for the complete system. In this context, the device response reported by Kim et al. [126], video recognition by Liu et al. [128], and simulated humidity prediction by Lee et al. [129] each provide evidence for methods addressing individual parts of the detection chain. Assessment of the complete system also incorporates signal propagation, redundancy, and the operating background into the same design objective.
The leak-before-break (LBB) procedures summarized by OECD NEA [140] assess leak detectability and crack stability together after screening materials, loads, and degradation mechanisms. In the U.S. procedure described in that report, the leakage crack size is determined under normal operating loads using a leak rate 10 times the detection limit. The ratio of the critical crack size under normal operating plus safe shutdown earthquake loads to this leakage crack size must be at least 2. These two margins relate to detection capability and fracture stability, respectively; they do not define a leak rate permitted for continued operation or replace assessment of the external jet consequences. Because the selected weld had potential for primary water stress corrosion cracking, the benchmark relaxed the applicability screening used in most participating countries to enable a comparison of methods. Comparability of the benchmark calculations and applicability to a specific pipe segment must therefore be interpreted separately.

6. Key Evidence Gaps and Research Outlook

Short-tube and crack experiments have explained the geometric and thermodynamic dependence of release rate [32,33,34,35,36,37,38,39]. Transparent-nozzle studies and finite-inventory releases have further connected phase state, morphology, and liquid-supply history [33,69], while monitoring and loading studies have developed descriptions of individual aspects of engineering responses [76,126,127,132]. These developments have shifted research questions toward the links between the stages. The following outlook therefore considers the observations and comparisons most capable of distinguishing their contributions.

6.1. Coupling Crack Hydraulics and Phase Change During Hot-Water Discharge

Zhang et al. [34,37,38,39] compared the effects of artificial microcracks, different thermodynamic boundary conditions, and deformation under pressure on flow rate. Revankar and Riznic [35] and Schmid et al. [36] extended the experiments to actual cracks and flow rates relevant to leak detection. An open question is whether cracks and regular short slits with similar cold-flow hydraulic behavior also behave similarly when hot water vaporizes. Crack opening under pressure and the cold-flow relationship between flow rate and pressure difference can provide a common hydraulic baseline, while phase-state data along the flow path can distinguish the contributions of flow resistance and vaporization.
Heckmann et al. [125] applied a metastable jet model to leakage from steam generator tubes, and Gorelik et al. [132] jointly investigated flow rate, static pressure, and reaction force. Linking such outlet and momentum observations to the pressure distribution and vaporization onset along a pressurized crack would help test how changes in geometry and phase-change closure each alter the external source term.

6.2. Distinguishing Primary Breakup from Downstream Droplet Evolution

Pan et al. [33] linked the phase content at the outlet of transparent water nozzles to external morphology. Lu et al. [50] and studies using dense-spray imaging [51,52,53,54] provided diagnostics of droplet size and velocity, spatial structure, and fluctuations inside and outside the orifice. Zhu et al. [69] recorded source-term and morphology histories during finite-inventory releases. These observations span different working fluids, facilities, and cross sections. A further question is how much primary breakup and downstream droplet evolution each contribute during the same water release. Connecting liquid-core length, breakup location, and droplet size–velocity distributions provides direct evidence for addressing this question.
The steam-jet measurements of Lim et al. [25] and the condensation model of Burluka [26] show that gas-phase mixing can generate new droplets. The spray flashing studies of Fathinia et al. [61,62] and the water-jet rainout study of Hocquet et al. [67] address different aspects of droplet transport, while Kim et al. [68] investigated condensing steam jets through combined experiments and simulations. Linking droplet-population observations to a common mass balance for liquid water, water vapor, and settled liquid can distinguish breakup, evaporation, condensation, and settling. Measurement detection limits, the large-droplet tail, and statistical weighting determine how far these contributions can be resolved.

6.3. Identification of Closure Parameters and Testing Across Operating Conditions

Downar-Zapolski et al. [87] developed a relaxation description, while Dang Le et al. [89] and Liu et al. [90] showed the sensitivity of pressure and void fraction to phase-change parameters. Li et al. [103], Liao and Lucas [105], Li et al. [106], and John and Lange [107,108] further addressed interfacial area and bubble-population evolution. With these model extensions, similar overall flow rates can correspond to different local distributions. Parameter identification therefore relies on observations that distinguish these responses: vaporization onset and the pressure minimum reflect delay, radial void-fraction profiles reflect phase migration, and bubble size and interfacial area distinguish nucleation from subsequent population evolution.
Liao and Lucas [100] compared interphase heat-transfer relations, and Liao et al. [101] tested mechanistic closures against single-bubble growth and condensation data. The interface-resolved calculations of Li et al. [102] further isolated the effects of bubble deformation and oscillation. These local studies provide a physical basis for heat-transfer closure. In a complete flashing flow, bubble generation, growth, and turbulent transport occur together, so independent observations of heat transfer per unit area and interfacial area can help distinguish their contributions.
The comparison across databases by De Lorenzo et al. [77] provides a basis for testing under independent operating conditions. For subsequent models using the same experimental series, results for held-out facilities or geometries, together with a clear distinction between fixed parameters and recalibration, can show whether improved predictions arise from the physical description or parameter transfer. Local distributions, residuals, and cases in which predictions fail can further define the range over which such transfer is valid.

6.4. Uncertainty Analysis from the Leakage Source to Engineering Response

Zhang et al. [76] reported how loads on finite targets vary with geometry and distance, while Kim et al. [126] and Tian et al. [127] described device dynamics and system transport leading to condensation onset, respectively. These studies address different engineering objectives, so uncertainties in the source term, external field, and response propagate along different paths. Cumulative released mass, alarm delay, and target load have different sensitivities to crack opening under pressure, the vapor–liquid partition at the outlet, and transport through the surroundings.
By comparing the relationship between structural response and leak rate using common crack inputs, the OECD/NEA leak-before-break benchmark [140] provides a starting point for tracing errors in the source term. Connecting such source comparisons with target-size–force data [76], device dynamics, and system condensation-onset data [126,127] would help determine the contribution of each stage to the final engineering objective. Synchronized pressure and structural-response measurements would test the coupling among pulse intensity, duration, and structural period.

6.5. Scope and Comparability of Existing Data

De Lorenzo et al. [77] compiled several critical-flow databases, and Figure 5 and Table 2 also show the diversity of experimental geometries, thermodynamic paths, and diagnostic targets. Further links between datasets need to connect the outlet phase state, droplet populations, and engineering responses. Geometry under pressure, boundary-condition histories, observation locations, and uncertainties jointly determine whether quantitative comparisons between studies are possible.
Reuse of common benchmarks such as BNL and TOPFLOW has accumulated a continuing body of data for model comparisons [89,90,103,105,106,107,108]. Retaining the original definitions, reproducible conversions, and the distinction between calibration and independent testing makes it possible to trace the origins of improved predictions. Empirical relations used for different facilities remain dependent on their respective geometries, flow regimes, and thermodynamic ranges.

7. Conclusions

The literature on high-temperature, high-pressure water leakage has expanded from overall critical discharge to local phase state, droplet transport, and engineering response. Experimental observations and predictive models support the following conclusions.
(1) Short-tube and crack studies show that thermodynamic state, flow-path resistance, and the time available for vaporization to develop jointly control release rate. Deformation under pressure, tortuosity, and rough flow paths further modify the effective geometry. Transparent-nozzle observations link the phase content near the outlet to external morphology, making flow rate, phase state, and momentum at a real crack exit during hot-water discharge key quantities connecting the flow path to the jet.
(2) Near-field and droplet-size experiments show that jet spreading and the reduction in droplet size depend on the thermodynamic path and geometry. Finite-inventory releases also reveal the role of liquid-supply history. Downstream studies observe or describe heat and mass exchange and settling for droplets formed by breakup and condensation. Droplet origins and subsequent evolution are therefore central to connecting jet morphology with transport in the external field.
(3) Predictive models have developed from relations for overall release rate to finite-rate vaporization, separate phase motion, interfacial scales, and external spray transport. Existing validation data cover pressure, phase content, bubble size, and thermal response. Differences between models reflect differences in physical closures, data use, and parameter transfer. Local distributions and comparisons under independent operating conditions are the main basis for assessing the benefits of these extensions.
(4) Monitoring studies connect device signals to transport through the surroundings, sampling, and classification, while loading studies describe jet reaction force, total force on finite targets, and opening-stage pulses. Engineering criteria specify detection and equipment-protection objectives, and existing experiments and models support individual stages of the analysis. The detection capability of a complete system and the consequences for equipment also depend on how those stages are connected.
Further progress requires shared observations that connect the exit state during hot-water discharge through real cracks, droplet origins, and mass balances to specific monitoring and loading objectives, together with comparisons under independent operating conditions to test closure relations and uncertainty propagation.

Author Contributions

Yongling Zhang: Conceptualization, Investigation, Writing – original draft, Visualization. Feixiong Wang: Writing – original draft, Visualization. Lei Tang: Investigation, Writing – review & editing. Zibo Huang: Investigation, Writing – review & editing. Jinpeng Zhao: Visualization, Writing – review & editing. Wenjing Zhou: Resources, Funding acquisition, Conceptualization, Supervision, Writing – original draft, Writing – review & editingFunding: This work was supported by the National Key Laboratory of Nuclear Reactor Technology, Nuclear Power Institute of China (Grant No. KGSW-0224-0403-06).Institutional Review Board Statement: Not applicable

Acknowledgments

During the preparation of this manuscript, the authors used ChatGPT (OpenAI) to assist with the organization and preparation of selected explanatory illustrations (Figure 1, Figure 2, Figure 3 and Figure 4 and Figure 7, and 8). These illustrations were developed programmatically based on established physical principles and the cited literature. The authors have reviewed and edited the AI-assisted outputs and take full responsibility for the content of this publication.Conflicts of Interest: The authors declare no conflicts of interest

References

  1. Kim, Y. S.; Kim, J. H.; Kwon, T. S. A review of meta-stable aspects on a subcooled critical flow in nozzles and orifices. Ann. Nucl. Energy 2021, 159, 108328. [Google Scholar] [CrossRef]
  2. Tian, G.; Zhou, Y.; Huang, Y.; et al. A detailed review on critical flow experiments and models. Ann. Nucl. Energy 2025, 219, 111441. [Google Scholar] [CrossRef]
  3. Kong, R.; Kim, S.; Ishii, M. Review of jet impingement in high-energy piping systems. Nucl. Eng. Des. 2020, 357, 110411. [Google Scholar] [CrossRef]
  4. Sher, E.; Bar-Kohany, T.; Rashkovan, A. Flash-boiling atomization. Prog. Energy Combust. Sci. 2008, 34, 417–439. [Google Scholar] [CrossRef]
  5. Bar-Kohany, T.; Levy, M. State of the art review of flash-boiling atomization. At. Sprays 2016, 26(12), 1259–1305. [Google Scholar] [CrossRef]
  6. Bar-Kohany, T.; Arogeti, M.; Malka, A.; et al. Advances in liquid atomization via flash boiling—A global overview. Energies 2023, 16, 6763. [Google Scholar] [CrossRef]
  7. Yin, S.; Wang, N.; Wang, H. Nucleation and flashing inception in flashing flows: A review and model comparison. Int. J. Heat Mass Transf. 2020, 146, 118898. [Google Scholar] [CrossRef]
  8. Kim, S. M.; Mudawar, I. Review of two-phase critical flow models and investigation of the relationship between choking, premature CHF, and CHF in micro-channel heat sinks. Int. J. Heat Mass Transf. 2015, 87, 497–511. [Google Scholar] [CrossRef]
  9. Liao, Y.; Lucas, D. Computational modelling of flash boiling flows: A literature survey. Int. J. Heat Mass Transf. 2017, 111, 246–265. [Google Scholar] [CrossRef]
  10. Liao, Y.; Lucas, D. A review on numerical modelling of flashing flow with application to nuclear safety analysis. Appl. Therm. Eng. 2021, 182, 116002. [Google Scholar] [CrossRef]
  11. Liao, Y. CFD modelling of flashing flows for nuclear safety analysis: possibilities and challenges. Kerntechnik 2024, 89(2), 169–184. [Google Scholar] [CrossRef]
  12. Witlox, H. W. M.; Bowen, P. J. Flashing liquid jets and two-phase dispersion: A review. HSE Contract Research Report 403/2002; HSE Books: Sudbury, 2002; ISBN 0-7176-2250-9. [Google Scholar]
  13. Polanco, G.; Holdø, A. E.; Munday, G. General review of flashing jet studies. J. Hazard. Mater. 2010, 173, 2–18. [Google Scholar] [CrossRef] [PubMed]
  14. Mansour, A.; Müller, N. A review of flash evaporation phenomena and resulting shock waves. Exp. Therm. Fluid Sci. 2019, 107, 146–168. [Google Scholar] [CrossRef]
  15. Dewangan, K. K.; Satbhai, O.; Gavel, S. K.; et al. A comprehensive review of flashing phenomena and evaporation wave propagation in superheated liquids. Microgravity Sci. Technol. Correction: Microgravity Science and Technology, 2026, 38: 29. 2026, 38: 11. [Google Scholar] [CrossRef]
  16. Chen, S.; Qenawy, M.; Tian, J.; et al. From principles to practice: Review of recent advances and perspectives in spray flash evaporation technology towards thermal management of energy systems. Energy Convers. Manag. 2025, 326, 119499. [Google Scholar] [CrossRef]
  17. Li, X.; Wang, S.; Yang, S.; et al. A review on the recent advances of flash boiling atomization and combustion applications. Prog. Energy Combust. Sci. 2024, 100, 101119. [Google Scholar] [CrossRef]
  18. Yang, S.; Ma, Z.; Li, X.; et al. A review on the experimental non-intrusive investigation of fuel injector phase changing flow. Fuel 2020, 259, 116188. [Google Scholar] [CrossRef]
  19. Zhang, J.; Wang, M. J.; Zhang, Z.; et al. A comprehensive review of the leak flow through micro-cracks (in LBB) for nuclear system: Morphologies and thermal-hydraulic characteristics. Nucl. Eng. Des. 2020, 362, 110537. [Google Scholar] [CrossRef]
  20. Kitamura, Y.; Morimitsu, H.; Takahashi, T. Critical superheat for flashing of superheated liquid jets. Ind. Eng. Chem. Fundam. 1986, 25, 206–211. [Google Scholar] [CrossRef]
  21. Moshkovich, Y.; Levy, Y.; Sher, E. Theoretical criteria for homogeneous flash boiling atomization. Chem. Eng. Sci. 2019, 206, 471–475. [Google Scholar] [CrossRef]
  22. Eggers, J.; Villermaux, E. Physics of liquid jets. Rep. Prog. Phys. 2008, 71, 036601. [Google Scholar] [CrossRef]
  23. Mutair, S.; Ikegami, Y. On the evaporation of superheated water drops formed by flashing of liquid jets. Int. J. Therm. Sci. 2012, 57, 37–44. [Google Scholar] [CrossRef]
  24. Hu, W.; Zhao, Y.; Zhou, X.; et al. Experimental and numerical investigations on flash evaporation of a sessile droplet under reduced pressure. Phys. Fluids 2023, 35, 112119. [Google Scholar] [CrossRef]
  25. Lim, S.; Cha, J.; Lee, H.; et al. Understanding the condensation process of turbulent steam jet using the PDPA system. Int. J. Multiph. Flow 2018, 98, 168–181. [Google Scholar] [CrossRef]
  26. Burluka, A.A. Condensation processes in turbulent non-isothermal free steam jet in air. Int. J. Heat Mass Transf. 2024, 233, 126033. [Google Scholar] [CrossRef]
  27. Isbin, H. S.; Moy, J. E.; da Cruz, A. J. R. Two-phase, steam-water critical flow. AIChE J. 1957, 3(3), 361–365. [Google Scholar] [CrossRef]
  28. Moody, F. J. Maximum flow rate of a single component, two-phase mixture. J. Heat Transf. 1965, 87, 134–141. [Google Scholar] [CrossRef]
  29. Henry, R. E.; Fauske, H. K. The two-phase critical flow of one-component mixtures in nozzles, orifices, and short tubes. J. Heat Transf. 1971, 93, 179–187. [Google Scholar] [CrossRef]
  30. Pinhasi, G. A.; Ullmann, A.; Dayan, A. Modeling of flashing two-phase flow. Rev. Chem. Eng. 2005, 21(3-4), 133–264. [Google Scholar] [CrossRef]
  31. Calay, R. K.; Holdø, A. E. Modelling the dispersion of flashing jets using CFD. J. Hazard. Mater. 2008, 154(1-3), 1198–1209. [Google Scholar] [CrossRef] [PubMed]
  32. Chun, M. H.; Park, C. K.; Park, J. W. An experimental investigation of critical flow rates of subcooled water through short pipes with small diameters. Int. Commun. Heat Mass Transf. 1996, 23(8), 1053–1064. [Google Scholar] [CrossRef]
  33. Pan, X.; Zhu, W.; Tang, H.; et al. In-nozzle flow of superheated liquid release and the influence on the external flashing jet using transparent nozzles. Int. J. Multiph. Flow 2024, 175, 104799. [Google Scholar] [CrossRef]
  34. Zhang, K.; You, H. B.; Zhou, Y. K.; et al. Experimental investigations on leak flow rate characteristics of water through axial artificial microcracks of steam generator tubes under back pressure conditions. Nucl. Eng. Des. 2019, 353, 110285. [Google Scholar] [CrossRef]
  35. Revankar, S. T.; Riznic, J. An experimental investigation of subcooled choked flow in actual steam generator tube cracks. Nucl. Eng. Des. 2019, 354, 110144. [Google Scholar] [CrossRef]
  36. Schmid, S.; Silber, F.E.; Heckmann, K.; et al. Leak rate testing in the range of leak detection systems. Nucl. Eng. Des. 2021, 372, 111000. [Google Scholar] [CrossRef]
  37. Zhang, J.; Yu, H.; Wang, M. J.; et al. Experimental study on the flow and thermal characteristics of two-phase leakage through micro crack. Appl. Therm. Eng. 2019, 156, 145–155. [Google Scholar] [CrossRef]
  38. Zhang, K.; Shi, Y. G.; You, H. B.; et al. Experimental study on leak flow rate characteristics of high pressure subcooled water through axial and circumferential microcracks of steam generator tubes under high back pressure conditions. Ann. Nucl. Energy 2020, 145, 107551. [Google Scholar] [CrossRef]
  39. Zhang, J.; Li, C.; Deng, J.; et al. Experimental and theoretical study on fluid-structure interaction and non-equilibrium of the flow through micro cracks. Ann. Nucl. Energy 2020, 142, 107441. [Google Scholar] [CrossRef]
  40. Busov, K. A. The effect of boiling-up on the shape and droplet size of a jet of superheated water discharged through a semi-cylindrical nozzle. Int. Commun. Heat Mass Transf. 2022, 136, 106199. [Google Scholar] [CrossRef]
  41. Busov, K. A. Boiling-Up of a Jet of Superheated Water in Outflowing Through Channels of Different Diameters. J. Eng. Phys. Thermophys. 2023, 96(1), 64–72. [Google Scholar] [CrossRef]
  42. Reshetnikov, A. V.; Busov, K. A.; Mazheiko, N. A.; et al. Jets of boiling-up water injected by a short slit nozzle. Int. J. Heat Mass Transf. 2019, 130, 523–531. [Google Scholar] [CrossRef]
  43. Reshetnikov, A. V.; Busov, K. A.; Mazheiko, N. A.; et al. Transient behavior of superheated water jets boiling. Thermophys. Aeromechanics 2012, 19(2), 329–336. [Google Scholar] [CrossRef]
  44. Reshetnikov, A. V.; Mazheiko, N. A.; Busov, K. A. Recoil force and spray angle of a plane jet of superheated water. Interfacial Phenom. Heat Transf. 2017, 5(3), 201–206. [Google Scholar] [CrossRef]
  45. Pavlenko, A. N.; Koverda, V. P.; Reshetnikov, A. V.; et al. Disintegration of flows of superheated liquid films and jets. J. Eng. Thermophys. 2013, 22(3), 174–193. [Google Scholar] [CrossRef]
  46. Busov, K. A.; Reshetnikov, A. V.; Mazheiko, N. A.; et al. Atomization of a sheet jet of superheated water using a passive swirler. Microgravity Sci. Technol. 2020, 32, 99–104. [Google Scholar] [CrossRef]
  47. Busov, K. A.; Reshetnikov, A. V.; Mazheiko, N. A.; et al. Effect of a passive swirler on superheated liquid outflow. J. Appl. Mech. Tech. Phys. 2019, 60(1), 53–58. [Google Scholar] [CrossRef]
  48. Zalkind, V. I.; Zeigarnik Yu, A.; Nizovskii, V. L.; et al. Superheated Water Atomization: A Possibility of Obtaining Sprays of Droplets of Micron Diameters. High Temp. 2018, 56(1), 153–155. [Google Scholar] [CrossRef]
  49. Rogóż, R.; Teodorczyk, A.; Kapusta, Ł. J. Flash-boiling effect on the droplet size distribution in low-pressure sprays formed at various ambient pressures and liquid temperatures—Experimental study and modelling. Appl. Therm. Eng. 2024, 236, 121740. [Google Scholar] [CrossRef]
  50. Lu, Q.; Yu, X.; Shen, S.; et al. Visualization of spatial distribution of the droplet size and velocity in flash boiling spray with extended glare-point imaging technique. Fuel 2019, 242, 222–231. [Google Scholar] [CrossRef]
  51. Du, J.; Zang, G.; Mohan, B.; et al. Study of spray structure from non-flash to flash boiling conditions with space-time tomography. Proc. Combust. Inst. 2021, 38(2), 3223–3231. [Google Scholar] [CrossRef]
  52. Du, J.; Mohan, B.; Sim, J.; et al. Study of spray structure under flash boiling conditions using 2phase-SLIPI. Exp. Fluids 2021, 62(1), 24. [Google Scholar] [CrossRef]
  53. Qiu, S.; Wang, S.; Zhang, Y.; et al. Dense-field spray droplet size quantification of flashing boiling atomization using structured laser illumination planar imaging technique. Fuel 2023, 335, 127085. [Google Scholar] [CrossRef]
  54. Yang, S.; Ma, Z.; Wu, S.; et al. Dynamic characteristics of in-nozzle flash boiling bubbles and corresponding temporal responses of external spray. Exp. Fluids 2019, 60(10), 158. [Google Scholar] [CrossRef]
  55. Cai, B.; Wang, H.; Li, Q.; et al. Experimental investigation on thermal characteristics of spray flash evaporation under high temperature and high pressure. Ann. Nucl. Energy 2022, 167, 108869. [Google Scholar] [CrossRef]
  56. Miyatake, O.; Tomimura, T.; Ide, Y.; et al. Effect of liquid temperature on spray flash evaporation. Desalination 1981, 37, 351–366. [Google Scholar] [CrossRef]
  57. Mutair, S.; Ikegami, Y. Experimental investigation on the characteristics of flash evaporation from superheated water jets for desalination. Desalination 2010, 251, 103–111. [Google Scholar] [CrossRef]
  58. Fathinia, F.; Al-Abdeli, Y. M.; Khiadani, M. Evaporation rates and temperature distributions in fine droplet flash evaporation sprays. Int. J. Therm. Sci. 2019, 145, 106037. [Google Scholar] [CrossRef]
  59. Busov, K.; Mazheiko, N.; Plotnikov, L.; et al. Experimental investigation into a superheated water jet in visible and infrared ranges. Front. Heat Mass Transf. 2025, 23(4), 1203–1214. [Google Scholar] [CrossRef]
  60. Trofimov, A. A.; Watkins, T. R.; Muth, T. R.; et al. Infrared thermometry in high temperature materials processing: Influence of liquid water and steam. Quant. InfraRed Thermogr. J. 2023, 20(3), 123–141. [Google Scholar] [CrossRef]
  61. Fathinia, F.; Khiadani, M.; Al-Abdeli, Y. M. Experimental and mathematical investigations of spray angle and droplet sizes of a flash evaporation desalination system. Powder Technol. 2019, 355, 542–551. [Google Scholar] [CrossRef]
  62. Fathinia, F.; Khiadani, M.; Al-Abdeli, Y.M.; et al. Performance improvement of spray flash evaporation desalination systems using multiple nozzle arrangement. Appl. Therm. Eng. 2019, 163, 114385. [Google Scholar] [CrossRef]
  63. Cai, B.; Zhang, Q.; Jiang, Y.; et al. Experimental study on spray flash evaporation under high temperature and pressure. Int. J. Heat Mass Transf. 2017, 113, 1106–1115. [Google Scholar] [CrossRef]
  64. Ji, C.; Cheng, L.; Wang, N.; et al. Experimental investigation on high-pressure high-temperature spray flash evaporation and the characteristic Jakob number. Exp. Therm. Fluid Sci. 2019, 102, 94–100. [Google Scholar] [CrossRef]
  65. Ikegami, Y.; Sasaki, H.; Gouda, T.; et al. Experimental study on a spray flash desalination: Influence of the direction of injection. Desalination 2006, 194, 81–89. [Google Scholar] [CrossRef]
  66. Mutair, S.; Ikegami, Y. Experimental study on flash evaporation from superheated water jets: Influencing factors and formulation of correlation. Int. J. Heat Mass Transf. 2009, 52, 5643–5651. [Google Scholar] [CrossRef]
  67. Hocquet, J.; Adrian, J. C.; Godeau, M.; et al. Loss of containment: Experimental aerosol rain-out assessment. J. Hazard. Mater. 2002, 93(1), 67–76. [Google Scholar] [CrossRef] [PubMed]
  68. Kim, D.; Kim, J.; Cho, S.; et al. Experimental and numerical study of a condensing steam jet. J. Nucl. Sci. Technol. 2022, 59(9), 1089–1106. [Google Scholar] [CrossRef]
  69. Zhu, X.; Pan, X.; Mei, Y.; et al. Thermal nonequilibrium and mechanical forces induced breakup and droplet formation of superheated liquid jets under depressurized release. Appl. Therm. Eng. 2023, 221, 119826. [Google Scholar] [CrossRef]
  70. Wang, C.; Xu, R.; Chen, X.; et al. Study on water flash evaporation under reduced pressure. Int. J. Heat Mass Transf. 2019, 131, 31–40. [Google Scholar] [CrossRef]
  71. Wang, S.; Lin, Y. C.; Wang, G.; et al. Experimental investigation on flashing-induced flow instability in a natural circulation scaled-down test facility. Ann. Nucl. Energy 2022, 171, 109023. [Google Scholar] [CrossRef]
  72. Reshetnikov, A. V.; Mazheiko, N. A.; Begletsov, V. N.; et al. Pulsation dynamics during explosive boil-up of overheated water jets. Tech. Phys. Lett. 2007, 33(9), 732–734. [Google Scholar] [CrossRef]
  73. Busov, K. A.; Mazheiko, N. A.; Kapitunov, O. A.; et al. Transient modes in a swirl jet of superheated water. Int. J. Heat Mass Transf. 2020, 157, 119711. [Google Scholar] [CrossRef]
  74. Mansour, A.; Müller, N. Experimental investigation on flashing water jet and resulting shock wave. Alex. Eng. J. 2022, 61, 6433–6439. [Google Scholar] [CrossRef]
  75. He, X.; Gao, P.; Wang, J.; et al. Experimental investigation on hot water rapid depressurization process characteristics inside and outside of the ruptured pipeline. Nucl. Eng. Des. 2024, 425, 113341. [Google Scholar] [CrossRef]
  76. Zhang, T.; Bi, Q.; Wang, T.; et al. Experimental study on high-energy fluid jets from a pipe: Jet cone morphology and impact force on flat plates. Nucl. Eng. Des. 2024, 424, 113302. [Google Scholar] [CrossRef]
  77. De Lorenzo, M.; Lafon, P.; Seynhaeve, J. M.; et al. Benchmark of Delayed Equilibrium Model (DEM) and classic two-phase critical flow models against experimental data. Int. J. Multiph. Flow 2017, 92, 112–130. [Google Scholar] [CrossRef]
  78. He, Y.; Gu, W.; Wang, D. An optimized delayed equilibrium model for predicting the pressure profile of the critical flow in a slit. Prog. Nucl. Energy 2023, 159, 104649. [Google Scholar] [CrossRef]
  79. Xu, H.; Badea, A.F.; Cheng, X. Analysis of two phase critical flow with a non-equilibrium model. Nucl. Eng. Des. 2021, 372, 110998. [Google Scholar] [CrossRef]
  80. Xu, H.; Badea, A.F.; Cheng, X. Development of a new full-range critical flow model based on non-homogeneous non-equilibrium model. Ann. Nucl. Energy 2021, 158, 108286. [Google Scholar] [CrossRef]
  81. Zhao, X.; Liao, Y.; Wang, M.; et al. Numerical simulation of micro-crack leakage on steam generator heat transfer tube. Nucl. Eng. Des. 2021, 382, 111385. [Google Scholar] [CrossRef]
  82. Kim, Y. S. A proposed correlation for critical flow rate of water flow. Nucl. Eng. Technol. 2015, 47, 135–138. [Google Scholar] [CrossRef]
  83. Tesinsky, M. Validation of the Moody and Henry-Fauske critical flow models in APROS against Marviken critical flow experiments. J. Nucl. Eng. Radiat. Sci. 2020, 6, 041102. [Google Scholar] [CrossRef]
  84. Xu, H.; Badea, A.F.; Cheng, X. Studies on the criterion for choking process in two-phase flow. Prog. Nucl. Energy 2021, 133, 103640. [Google Scholar] [CrossRef]
  85. Zhang, J.; Sun, H.; Wang, M.; et al. Numerical study on the thermal-hydraulic characteristics of the choked flow through micro cracks for various conditions. Nucl. Eng. Des. 2020, 358, 110381. [Google Scholar] [CrossRef]
  86. Łapka, P.; Seredyński, M.; Grzebielec, A.; et al. Numerical investigation of nozzle shape effect on the flash boiling phenomenon. Numer. Heat Transf. Part A Appl. 2024, 85(24), 4283–4305. [Google Scholar] [CrossRef]
  87. Downar-Zapolski, P.; Bilicki, Z.; Bolle, L.; et al. The non-equilibrium relaxation model for one-dimensional flashing liquid flow. Int. J. Multiph. Flow 1996, 22(3), 473–483. [Google Scholar] [CrossRef]
  88. Karathanassis, I. K.; Koukouvinis, P.; Gavaises, M. Comparative evaluation of phase-change mechanisms for the prediction of flashing flows. Int. J. Multiph. Flow 2017, 95, 257–270. [Google Scholar] [CrossRef]
  89. Dang Le, Q.; Mereu, R.; Besagni, G.; et al. Numerical modelling of flashing flow phase change in convergent-divergent nozzle: A sensitivity analysis. J. Phys. Conf. Ser. 2019, 1224, 012010. [Google Scholar] [CrossRef]
  90. Liu, Z.; Wang, S.; Lin, Z.; et al. A non-equilibrium phase change model based on the Lee model for flashing flows in converging-diverging nozzles. Nucl. Eng. Des. 2024, 423, 113185. [Google Scholar] [CrossRef]
  91. Dang Le, Q.; Mereu, R.; Besagni, G.; et al. Computational Fluid Dynamics Modeling of Flashing Flow in Convergent-Divergent Nozzle. J. Fluids Eng. 2018, 140(10), 101102. [Google Scholar] [CrossRef]
  92. Le, A. D. Study of Thermodynamic Effect on the Mechanism of Flashing Flow Under Pressurized Hot Water by a Homogeneous Model. J. Fluids Eng. 2022, 144(1), 011206. [Google Scholar] [CrossRef]
  93. Jin, M. S.; Ha, C. T.; Park, W. G. Numerical study on heat transfer effects of cavitating and flashing flows based on homogeneous mixture model. Int. J. Heat Mass Transf. 2017, 109, 1068–1083. [Google Scholar] [CrossRef]
  94. Narayanan, C. Numerical simulation of flashing using a pressure-based compressible multiphase approach and a thermodynamic cavitation model. Int. J. Multiph. Flow 2021, 135, 103511. [Google Scholar] [CrossRef]
  95. Yin, S.; Wang, H.; Xu, B.; et al. Critical flow leakage of a vapour-liquid mixture from sub-cooled water: Nucleation boiling study. Int. J. Heat Mass Transf. 2020, 146, 118807. [Google Scholar] [CrossRef]
  96. Ding, H. C.; Zhang, D. S.; Li, D.; et al. High-pressure-drop two-phase critical flow with a non-homogeneous equilibrium model. Phys. Fluids 2025, 37(7), 075148. [Google Scholar] [CrossRef]
  97. Mat, M. D.; Kuhn, D.; Batta, A. Application of the homogeneous relaxation model for flash boiling under sub-atmospheric pressures. Int. J. Heat Mass Transf. 2026, 257, 128240. [Google Scholar] [CrossRef]
  98. Liao, H.; Liu, Q.; Gao, Y.; et al. A simplified two-fluid model for more stable microchannel two-phase critical flow prediction. Chem. Eng. Sci. 2024, 290, 119885. [Google Scholar] [CrossRef]
  99. Yin, S.; Zhu, M.; Huang, X.; et al. Modeling of micro-channel critical flow with inlet sub-cooling: Metastable liquid and nucleation. Chem. Eng. Sci. 2022, 249, 117302. [Google Scholar] [CrossRef]
  100. Liao, Y.; Lucas, D. Evaluation of interfacial heat transfer models for flashing flow with two-fluid CFD. Fluids 2018, 3, 38. [Google Scholar] [CrossRef]
  101. Liao, Y.; Krepper, E.; Lucas, D. A baseline closure concept for simulating bubbly flow with phase change: A mechanistic model for interphase heat transfer coefficient. Nucl. Eng. Des. 2019, 348, 1–13. [Google Scholar] [CrossRef]
  102. Li, J.; Liao, Y.; Bolotnov, I.A.; et al. Direct numerical simulation of heat transfer on a deformable vapor bubble rising in superheated liquid. Phys. Fluids 2023, 35(2), 023319. [Google Scholar] [CrossRef]
  103. Li, J.; Liao, Y.; Zhou, P.; et al. Numerical simulation of flashing flows in a converging-diverging nozzle with interfacial area transport equation. Processes 2023, 11, 2365. [Google Scholar] [CrossRef]
  104. Liao, Y.; Lucas, D. Possibilities and limitations of CFD simulation for flashing flow scenarios in nuclear applications. Energies 2017, 10, 139. [Google Scholar] [CrossRef]
  105. Liao, Y.; Lucas, D. Numerical analysis of flashing pipe flow using a population balance approach. Int. J. Heat Fluid Flow 2019, 77, 299–313. [Google Scholar] [CrossRef]
  106. Li, J.; Liao, Y.; Zhou, P.; et al. Numerical study of flashing pipe flow using a TFM-PBM coupled method: Effect of interfacial heat transfer and bubble coalescence and breakup. Int. J. Therm. Sci. 2023, 193, 108504. [Google Scholar] [CrossRef]
  107. John, S.; Lange, C. F. A limited evaporation model for flashing applications. Int. J. Heat Mass Transf. 2024, 225, 125351. [Google Scholar] [CrossRef]
  108. John, S.; Lange, C. F. A bulk nucleation model for flashing applications. Int. J. Heat Mass Transf. 2025, 236, 126244. [Google Scholar] [CrossRef]
  109. Liao, Y.; Lucas, D. CFD modeling of phase change during the flashing-induced instability in a natural circulation circuit. Processes 2023, 11(7), 1974. [Google Scholar] [CrossRef]
  110. Meller, R.; Schlegel, F.; Lucas, D. Basic verification of a numerical framework applied to a morphology adaptive multifield two-fluid model considering bubble motions. Int. J. Numer. Methods Fluids 2021, 93(3), 748–773. [Google Scholar] [CrossRef]
  111. Meller, R.; Tekavčič, M.; Krull, B.; et al. Momentum exchange modeling for coarsely resolved interfaces in a multifield two-fluid model. Int. J. Numer. Methods Fluids 2023, 95(9), 1521–1545. [Google Scholar] [CrossRef]
  112. Lyras, K.; Dembele, S.; Schmidt, D. P.; et al. Numerical simulation of subcooled and superheated jets under thermodynamic non-equilibrium. Int. J. Multiph. Flow 2018, 102, 16–28. [Google Scholar] [CrossRef]
  113. Lyras, K. G.; Dembele, S.; Wen, J. X. Numerical simulation of flashing jets atomisation using a unified approach. Int. J. Multiph. Flow 2019, 113, 45–58. [Google Scholar] [CrossRef]
  114. Guo, G.; Zhu, C. A modified lumped heat capacity model for droplet flash cooling. Int. Commun. Heat Mass Transf. 2021, 127, 105557. [Google Scholar] [CrossRef]
  115. Razzaghi, M. Droplet size estimation of two-phase flashing jets. Nucl. Eng. Des. 1989, 114, 115–124. [Google Scholar] [CrossRef]
  116. Hosseini Araghi, A.; Khiadani, M.; Sadafi, M. H.; et al. A numerical model and experimental verification for analysing a new vacuum spray flash desalinator utilising low grade energy. Desalination 2017, 413, 109–118. [Google Scholar] [CrossRef]
  117. Cai, B.; Wang, Q.; Yin, S.; et al. Energy analysis of spray flash evaporation from superheated upward jets. Appl. Therm. Eng. 2019, 148, 704–713. [Google Scholar] [CrossRef]
  118. Cai, B.; Yin, Y.; Zheng, Y.; et al. Mathematical study of spray flash evaporation in a spray-assisted seawater desalination chamber. Desalination 2019, 465, 25–37. [Google Scholar] [CrossRef]
  119. Guo, G.; Zhang, B.; Zhu, C.; et al. Thermal non-equilibrium in spray flash with vacuum vapor extraction. Desalination 2021, 507, 115023. [Google Scholar] [CrossRef]
  120. Guo, G.; Deng, H.; Zhu, C.; et al. Spatially dependent salinity effect in actively vacuumed spray flash desalination. Desalination 2022, 537, 115868. [Google Scholar] [CrossRef]
  121. Zhang, L.; Liu, Z. Study on the characteristics of high-temperature and high-pressure spray flash evaporation for zero-liquid discharge of desulfurization wastewater. Energies 2025, 18, 3180. [Google Scholar] [CrossRef]
  122. Rane, S.; He, L. CFD analysis of flashing flow in two-phase geothermal turbine design. J. Comput. Des. Eng. 2020, 7(2), 238–250. [Google Scholar] [CrossRef]
  123. Rane, S.; He, L. Numerical analysis of a novel two-phase turbine using thermal non-equilibrium, homogeneous nucleation phase change. Therm. Sci. Eng. Prog. 2021, 22, 100827. [Google Scholar] [CrossRef]
  124. He, Y.; Gu, W.; Wang, D. Verification of Delayed Equilibrium Model for the R134a critical flow in a slit. Prog. Nucl. Energy 2024, 174, 105282. [Google Scholar] [CrossRef]
  125. Heckmann, K.; Silber, F.; Sievers, J.; et al. A metastable jet model for leaks in steam generator tubes. Nucl. Eng. Des. 2022, 389, 111673. [Google Scholar] [CrossRef]
  126. Kim, H. J.; Shin, H. Y.; Pyeon, C. H.; et al. Fiber-optic humidity sensor system for the monitoring and detection of coolant leakage in nuclear power plants. Nucl. Eng. Technol. 2020, 52(8), 1689–1696. [Google Scholar] [CrossRef]
  127. Tian, M.; Cong, T.; Ma, Z.; et al. A new unidentified leak detection method based on the EVR ventilation condensate. Prog. Nucl. Energy 2017, 98, 11–22. [Google Scholar] [CrossRef]
  128. Liu, J.; Huang, Y.; Zhang, M.; et al. Detecting Steam Leakage in Nuclear Power Systems Based on the Improved Background Subtraction Method. Processes 2024, 12(7), 1538. [Google Scholar] [CrossRef]
  129. Lee, S. H.; Jo, H. S.; Na, M. G. Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks. Nucl. Eng. Technol. 2024, 56(5), 1725–1732. [Google Scholar] [CrossRef]
  130. Lee, J. C.; Choi, Y. R.; Cho, J. W. Pipe leakage detection using ultrasonic acoustic signals. Sens. Actuators A Phys. 2023, 349, 114061. [Google Scholar] [CrossRef]
  131. Choi, Y. R.; Yeo, D.; Lee, J. C.; et al. A Novel Ultrasonic Leak Detection System in Nuclear Power Plants Using Rigid Guide Tubes with FCOG and SNR. Sensors 2024, 24(20), 6524. [Google Scholar] [CrossRef] [PubMed]
  132. Gorelik, R. S.; Koronkevich, M. A.; Safarova, N. S.; et al. Discharge and dynamic characteristics of boiling water in Laval nozzles. J. Eng. Phys. 1978, 35(5), 1282–1286. [Google Scholar] [CrossRef]
  133. Kong, R.; Kim, S.; Ishii, M. Jet impingement in high-energy piping systems, Part I: Characteristics and model evaluation. Prog. Nucl. Energy 2021, 142, 104002. [Google Scholar] [CrossRef]
  134. Kong, R.; Kim, S.; Ishii, M. Jet impingement in high-energy piping systems, Part II: Model improvement and guidance development. Prog. Nucl. Energy 2021, 142, 104001. [Google Scholar] [CrossRef]
  135. Yuasa, T.; Watanabe, S.; Morita, R. An improved model for predicting affected region of flashing jet. J. Press. Vessel Technol. 2024, 146(6), 061401. [Google Scholar] [CrossRef]
  136. Avdeev, A. A. The shape of jets during discharge of a superheated liquid (structure of wave formations and the reactive force). High Temp. 2016, 54(5), 698–707. [Google Scholar] [CrossRef]
  137. Mansour, A.; Müller, N.; Alshybani, I. Numerical investigation on shock waves generated by flashing water jet. Alex. Eng. J. 2022, 61, 7489–7507. [Google Scholar] [CrossRef]
  138. Alekseev, M. V.; Vozhakov, I. S.; Lezhnin, S. I.; et al. Wave processes at outflow of water coolant with initial supercritical parameters. Thermophys. Aeromechanics 2017, 24(5), 799–802. [Google Scholar] [CrossRef]
  139. Charrouf, M.; Kauffman, S.; Yoon, J. K.; et al. Analysis methods for high energy line break jet flows in nuclear power plants. J. Nucl. Eng. Radiat. Sci. 2020, 6, 041112. [Google Scholar] [CrossRef]
  140. OECD Nuclear Energy Agency. NEA Leak-Before-Break Benchmark Phase 1 Final Report NEA/CSNI/R(2021)13; OECD Nuclear Energy Agency: Paris, 2024. [Google Scholar]
  141. U.S. Nuclear Regulatory Commission. 10 CFR Part 50, Appendix A: General Design Criteria for Nuclear Power Plants. eCFR, current text as of 2026-10-21. Available online: https://www.ecfr.gov/current/title-10/chapter-I/part-50/subject-group-ECFR89aa6ca4aada73c/appendix-Appendix%20A%20to%20Part%2050 (accessed on 2026-10-24).
  142. International Atomic Energy Agency. Protection against Internal Hazards in the Design of Nuclear Power Plants. IAEA Safety Standards Series No. SSG-64, STI/PUB/1947; IAEA: Vienna, 2021; Available online: https://www-pub.iaea.org/MTCD/Publications/PDF/PUB1947_web.pdf.
  143. U.S. Nuclear Regulatory Commission. Safety Evaluation Report Related to the Operation of Watts Bar Nuclear Plant Unit 2, Supplement 22. NUREG-0847, Supplement 22. NRC: Washington, DC, 2011; pp. 5–5. Available online: https://www.govinfo.gov/content/pkg/GOVPUB-Y3_N88-PURL-gpo9891/pdf/GOVPUB-Y3_N88-PURL-gpo9891.pdf.
  144. Fourcade, N.; Poydenot, F.; Langlois, P.; et al. Size and shape of condensing steam jets and plumes. Phys. Rev. Lett. 2026, 137, 154001. [Google Scholar] [CrossRef] [PubMed]
  145. Kim, S.; Ishii, M.; Kong, R. NUREG/CR-7275; Jet Impingement in High-Energy Piping Systems. U.S. Nuclear Regulatory Commission: Washington, DC, 2021.
  146. Majumdar, S.; Bakhtiari, S.; Kasza, K.; et al. NUREG/CR-6774 / ANL-01/34; Validation of Failure and Leak Rate Correlations for Stress Corrosion Cracks in Steam Generator Tubes. Argonne National Laboratory, 2002. [CrossRef]
  147. Peter, E. M.; Takimoto, A.; Hayashi, Y. Flashing and shattering phenomena of superheated liquid jets. JSME Int. J. Ser. B Fluids Therm. Eng. 1994, 37(2), 313–321. [Google Scholar] [CrossRef]
  148. Basset, T.; Viggiano, B.; Barois, T.; et al. Entrainment, diffusion and effective compressibility in a self-similar turbulent jet. J. Fluid Mech. 2022, 947, A29. [Google Scholar] [CrossRef]
  149. Vu, H.; García-Valladares, O.; Aguilar, G. Vapor/liquid phase interaction in flare flashing sprays used in dermatologic cooling. Int. J. Heat Mass Transf. 2008, 51, 5721–5731. [Google Scholar] [CrossRef]
Figure 1. Thermodynamic disequilibrium after depressurization of a fluid element and three independent observables. (a) Liquid temperature Tl and pressure p indicate departure from the saturation relation during rapid depressurization and subsequent cooling by vaporization; the path is not assumed to be isenthalpic. (b) xn, xb, and xT are defined by the first discernible vapor, disappearance of the connected liquid core, and stabilization of the measured temperature Tm, respectively. The local breakup features follow water-jet images showing an oscillating core, bulges, necks, intermittent liquid fragments, and droplets [69]. Closed white contours represent vapor bubbles within liquid; dispersed droplets indicate their spatial distribution. The three locations need not coincide or follow a fixed order. A temperature plateau is affected by probe response and wetting and cannot, on its own, establish complete vaporization or thermal equilibrium [1,6,7,20,23,24,25,26].
Figure 1. Thermodynamic disequilibrium after depressurization of a fluid element and three independent observables. (a) Liquid temperature Tl and pressure p indicate departure from the saturation relation during rapid depressurization and subsequent cooling by vaporization; the path is not assumed to be isenthalpic. (b) xn, xb, and xT are defined by the first discernible vapor, disappearance of the connected liquid core, and stabilization of the measured temperature Tm, respectively. The local breakup features follow water-jet images showing an oscillating core, bulges, necks, intermittent liquid fragments, and droplets [69]. Closed white contours represent vapor bubbles within liquid; dispersed droplets indicate their spatial distribution. The three locations need not coincide or follow a fixed order. A temperature plateau is affected by probe response and wetting and cannot, on its own, establish complete vaporization or thermal equilibrium [1,6,7,20,23,24,25,26].
Preprints 246046 g001
Figure 2. Near-field breakup patterns, coupling sections, and phase-fraction definitions. (a) The three rows show weak or absent flashing, partial flashing, and strong flashing, based on water-jet experiments [59,69,147]. They represent separate operating conditions rather than three successive regions of a single jet; substantial liquid can remain as droplets under strong flashing. Morphology depends jointly on nucleation location, superheat, back pressure, passage geometry, and liquid-supply history, so no universal transition thresholds are assigned. A is the geometric exit. B is selected where the local pressure approaches ambient pressure and cannot be located from the breakup pattern alone. It may contain a liquid core or a dispersed vapor-liquid region, and its position varies with operating conditions. (b) The conversion between void fraction α, inventory quality xh, and flow quality xf applies to the same uniform, one-dimensional, cocurrent representative state of water and its vapor; S = ug/ul. Entrained air requires a separate species balance, and nonuniform sections require the corresponding integrals and averaging definitions [27,28,29,30].
Figure 2. Near-field breakup patterns, coupling sections, and phase-fraction definitions. (a) The three rows show weak or absent flashing, partial flashing, and strong flashing, based on water-jet experiments [59,69,147]. They represent separate operating conditions rather than three successive regions of a single jet; substantial liquid can remain as droplets under strong flashing. Morphology depends jointly on nucleation location, superheat, back pressure, passage geometry, and liquid-supply history, so no universal transition thresholds are assigned. A is the geometric exit. B is selected where the local pressure approaches ambient pressure and cannot be located from the breakup pattern alone. It may contain a liquid core or a dispersed vapor-liquid region, and its position varies with operating conditions. (b) The conversion between void fraction α, inventory quality xh, and flow quality xf applies to the same uniform, one-dimensional, cocurrent representative state of water and its vapor; S = ug/ul. Entrained air requires a separate species balance, and nonuniform sections require the corresponding integrals and averaging definitions [27,28,29,30].
Preprints 246046 g002
Figure 3. Crack leakage path, surface opening, and three comparison objectives. (a) A tortuous through-wall passage with a variable opening. The wall thickness t differs from the path length L, and w(s,p) denotes the local opening along the path. (b) Crack-mouth opening along the surface coordinate z in the reference and loaded states; l c is the crack-mouth length. Crack photographs and leakage studies support the nonuniformity of the opening [34,35,36,37,38,39,125,146]. The profiles illustrate geometric quantities; increasing opening with load is not a universal law for all cracks. (c) Equal-area comparison using the same projection and loading state. (d) Matching the mass-flow-rate response under corresponding thermodynamic conditions and back-pressure histories over a specified pressure-difference range. The allowable deviation should account for measurement and model uncertainties. (e) Matching bulk exit variables at corresponding coupling sections. The three objectives are independent; agreement in bulk variables does not replace comparisons of local profiles and droplet size-velocity-direction statistics.
Figure 3. Crack leakage path, surface opening, and three comparison objectives. (a) A tortuous through-wall passage with a variable opening. The wall thickness t differs from the path length L, and w(s,p) denotes the local opening along the path. (b) Crack-mouth opening along the surface coordinate z in the reference and loaded states; l c is the crack-mouth length. Crack photographs and leakage studies support the nonuniformity of the opening [34,35,36,37,38,39,125,146]. The profiles illustrate geometric quantities; increasing opening with load is not a universal law for all cracks. (c) Equal-area comparison using the same projection and loading state. (d) Matching the mass-flow-rate response under corresponding thermodynamic conditions and back-pressure histories over a specified pressure-difference range. The allowable deviation should account for measurement and model uncertainties. (e) Matching bulk exit variables at corresponding coupling sections. The three objectives are independent; agreement in bulk variables does not replace comparisons of local profiles and droplet size-velocity-direction statistics.
Preprints 246046 g003
Figure 5. Geometric dimensions and length-to-diameter ratios of representative water experiments [32,33,37,40,41]. (a) Circular-tube diameter, flow-derived equivalent diameter, and artificial-slit opening w are identified separately. (b) Circular-tube length-to-diameter ratios are calculated from the corresponding lengths and diameters; slit L/D is the ratio of passage depth to equivalent hydraulic diameter. The 0.58 mm equivalent diameter of the semicircular nozzle is inferred from cold-water flow rate and an assumed discharge coefficient. The slit-opening range of 46.5-220 μm and L/D range of 4-21 are those reported in the original study [37]. The horizontal axes are logarithmic, and horizontal lines indicate the ranges covered by the experiments. Range endpoints in different columns do not automatically represent paired conditions. The dash indicates that an L/D value for the semicircular nozzle is not included in this comparison.
Figure 5. Geometric dimensions and length-to-diameter ratios of representative water experiments [32,33,37,40,41]. (a) Circular-tube diameter, flow-derived equivalent diameter, and artificial-slit opening w are identified separately. (b) Circular-tube length-to-diameter ratios are calculated from the corresponding lengths and diameters; slit L/D is the ratio of passage depth to equivalent hydraulic diameter. The 0.58 mm equivalent diameter of the semicircular nozzle is inferred from cold-water flow rate and an assumed discharge coefficient. The slit-opening range of 46.5-220 μm and L/D range of 4-21 are those reported in the original study [37]. The horizontal axes are logarithmic, and horizontal lines indicate the ranges covered by the experiments. Range endpoints in different columns do not automatically represent paired conditions. The dash indicates that an L/D value for the semicircular nozzle is not included in this comparison.
Preprints 246046 g005
Figure 7. Finite-rate phase change, thermal feedback and interfacial area. (a) For a constant equilibrium target xeq and relaxation time τ, the normalized response is 1−exp(−t/τ), with x0<xeq; it equals 0.632 at t/τ=1. Heat uptake during vaporization, liquid cooling and saturation-pressure feedback are shown separately as a sequence of mechanisms; their coupling through the energy balance is not included in the curve with prescribed parameters. (b) Three-dimensional spherical bubbles occupy equal mixture volumes V. Both groups use the same orthographic projection, so the displayed radius does not vary with depth. The 2 spheres of radius R and 16 spheres of radius R/2 have equal total vapor volumes; the latter group has twice the total interfacial area. All spheres lie inside the volumes and do not touch one another; surface shading indicates curvature. Vg=N4πr³/3 and Ai=N4πr²; ai=Ai/V=6α/d32 applies to dispersed spherical interfaces. The phase-change rate also depends on local thermodynamic driving forces and transfer coefficients [87,88,89,90,91,92,93,94,103,104,105,106].
Figure 7. Finite-rate phase change, thermal feedback and interfacial area. (a) For a constant equilibrium target xeq and relaxation time τ, the normalized response is 1−exp(−t/τ), with x0<xeq; it equals 0.632 at t/τ=1. Heat uptake during vaporization, liquid cooling and saturation-pressure feedback are shown separately as a sequence of mechanisms; their coupling through the energy balance is not included in the curve with prescribed parameters. (b) Three-dimensional spherical bubbles occupy equal mixture volumes V. Both groups use the same orthographic projection, so the displayed radius does not vary with depth. The 2 spheres of radius R and 16 spheres of radius R/2 have equal total vapor volumes; the latter group has twice the total interfacial area. All spheres lie inside the volumes and do not touch one another; surface shading indicates curvature. Vg=N4πr³/3 and Ai=N4πr²; ai=Ai/V=6α/d32 applies to dispersed spherical interfaces. The phase-change rate also depends on local thermodynamic driving forces and transfer coefficients [87,88,89,90,91,92,93,94,103,104,105,106].
Preprints 246046 g007
Figure 8. Net source load, impingement on a finite target, and resultant pressure force. (a) n is the outward normal to the planar outlet. Rs,n is the net axial load exerted on the selected solid body at the source by the internal fluid and uniform external ambient pressure; it excludes support reactions. PCV,n is the axial momentum within the control volume. The control volume is fixed, with a closed upstream end and no inlet. Axial body forces and viscous traction at the outlet are neglected. αk, ρk, and uk,n are the local phase volume fraction, density, and axial velocity, respectively; αg + αl = 1, and the phases share a common pressure p. The two-fluid expression shown neglects unresolved phase-velocity stresses. For uniform velocities and outlet pressure, Πn reduces to Σk ṁk uk,n + (pe − pa)Ae. (b) The black and blue solid lines and the green dashed lines indicate incident flow, flow turning along the front face, and bypass flow, respectively; H is the stand-off distance. Fp,n is the pressure component of force due to the pressure difference between the front and back faces of the flat target. Impact contributions already included in the integrated wall pressure must not be added again. (c) Annular integration applies when the pressure difference across a circular target is axisymmetric, with dAring = 2πr dr. Center pressure alone cannot determine the resultant force. All quantities may vary with time, and the force direction follows from the signed balance [42,44,76,132,133,134,135,136,137,138,139,145].
Figure 8. Net source load, impingement on a finite target, and resultant pressure force. (a) n is the outward normal to the planar outlet. Rs,n is the net axial load exerted on the selected solid body at the source by the internal fluid and uniform external ambient pressure; it excludes support reactions. PCV,n is the axial momentum within the control volume. The control volume is fixed, with a closed upstream end and no inlet. Axial body forces and viscous traction at the outlet are neglected. αk, ρk, and uk,n are the local phase volume fraction, density, and axial velocity, respectively; αg + αl = 1, and the phases share a common pressure p. The two-fluid expression shown neglects unresolved phase-velocity stresses. For uniform velocities and outlet pressure, Πn reduces to Σk ṁk uk,n + (pe − pa)Ae. (b) The black and blue solid lines and the green dashed lines indicate incident flow, flow turning along the front face, and bypass flow, respectively; H is the stand-off distance. Fp,n is the pressure component of force due to the pressure difference between the front and back faces of the flat target. Impact contributions already included in the integrated wall pressure must not be added again. (c) Annular integration applies when the pressure difference across a circular target is axisymmetric, with dAring = 2πr dr. Center pressure alone cannot determine the resultant force. All quantities may vary with time, and the force direction follows from the signed balance [42,44,76,132,133,134,135,136,137,138,139,145].
Preprints 246046 g008
Table 1. Key physical quantities in discharge and their observational interpretation.
Table 1. Key physical quantities in discharge and their observational interpretation.
Region or response Main quantities Physical relevance Typical observations and interpretation
Upstream region and passage Pressure, temperature, effective area, length, and crack morphology Available energy; pressure drop and residence time Boundary-condition histories and geometric measurements; nominal dimensions and effective area
Source Mass flow rate, mass flux, and total-energy flow rate Inventory loss and release rate Mass flow rate from flowmeters, weighing, or a mass balance; total-energy flow rate additionally requires phase temperatures and pressures or enthalpies, velocities, and an energy balance
Exit state Pressure at the coupling section, flow quality, void fraction, and phase temperatures and velocities Phase partition and momentum and energy transport Phase-state diagnostics and phase-resolved measurements; specify cross-sectional, volume, or flux averaging and sampling weights; account separately for entrained air and water vapor
Interfacial structure Liquid core, ligaments, bubble and droplet sizes, and their distributions Phase change, drag, and breakup High-speed imaging and phase-state or size diagnostics; specify spatial resolution, measurement locations, and number, area, or volume weighting
External field Temperature, humidity, droplet velocity and concentration, and pressure Entrainment, evaporation, condensation, and propagation Optical methods and local probes; line-of-sight integration and response time
Thermal and mechanical response Heat flux, hydrodynamic load at the source, target pressure difference, resultant force, and impulse Thermal effects, impingement, and dynamic response Heat-flux, force, and front- and rear-face pressure measurements; specify the two-dimensional loaded area and time window, and distinguish pressure impulse from force impulse
Table 4. Classification dimensions and combinations of multiphase-flow models.
Table 4. Classification dimensions and combinations of multiphase-flow models.
Classification dimension Main descriptions What is represented Validation limitations
Conservation framework Mixture, two-fluid, multifield, Eulerian-Lagrangian Defines the phases, velocity fields and energy variables to be solved Overall mass flux alone cannot independently identify relative phase velocities or phase-specific energies
Phase-change and interphase closures HEM (equal velocities and local thermodynamic equilibrium), HRM, DEM, interfacial heat transfer/nucleation; slip, drag and non-drag forces Prescribes relative phase motion and thermodynamic states, or describes phase change and interphase heat, mass and momentum transfer Vaporization delay, heat-transfer timescales and interface states depend on operating conditions; pressure and phase-state data constrain different closures
Interface and size representation VOF, IATE, PBM, Lagrangian droplet-size evolution Resolves continuous interfaces or statistically represents dispersed-phase sizes Continuous-interface shape, transfer area and size statistics correspond to different observables and resolution ranges
Typical combinations HRM-VOF; TFM-IATE/PBM; multicomponent gas phase-droplet tracking Connects local flow regimes with different predicted quantities Validation of individual modules does not validate the complete process; mass, momentum and energy must be consistent at the coupling plane
Note: HEM, DEM and IATE denote the homogeneous equilibrium model, delayed equilibrium model and interfacial area transport equation, respectively. A given conservation framework can accommodate different treatments of phase change, energy and interfacial scales. These categories do not define levels of accuracy.
Table 5. Modeling approaches compared with experiments and evidence gaps for different predicted quantities.
Table 5. Modeling approaches compared with experiments and evidence gaps for different predicted quantities.
Predicted quantity Modeling approaches compared with experiments Scope of supporting evidence Main gaps
Leakage rate and inventory change Equilibrium, slip or finite-rate critical-flow relations Critical-flow compilations and Marviken tests assess mass flux and pressure [77,80,83] Inlet state, effective resistance and discharge stage affect coefficients; overall mass flux does not independently constrain local phase state
Channel pressure and vaporization onset Mixture framework with HRM or other phase-change relations Pressure undershoot, onset and phase fractions jointly constrain response rate [87,89,90] Parameter calibration, properties and energy treatment may compensate for one another; pressure and phase-state predictions do not always improve together
Slip and radial phase distribution Two-fluid models and interphase exchange relations Microchannel and nozzle data assess pressure and mean or radial phase fractions [98,99,107,108] Flow-regime and energy assumptions limit applicability; [107,108] use isothermal treatment and temperature-dependent parameter selection; pressure and void-fraction comparisons do not independently validate slip velocity
Interfacial area and bubble size TFM–IATE or TFM–PBM TOPFLOW bubble diameters and void fractions [105,106]; nozzle onset, pressure and void fraction [103] Evidence mainly concerns dispersed bubbles; interfacial area inferred from bubble diameter and void fraction is not an independent observation; IATE/PBM results depend on source-term configuration
Plume and droplet transport Eulerian interfacial area density; multicomponent gas phase with droplet tracking and evaporation/condensation Water SMD and R134a SMD/velocity [113], temperature and evaporation rate [116,117,118,119], and condensate droplets [25,26] constrain different processes Fluids and environments differ; validation with prescribed size/velocity does not cover primary droplet formation; the full vapor–liquid partitioning sequence remains unvalidated
Reaction force, impingement and opening pulses Engineering jet relations or transient compressible CFD Reaction force, total force on finite plates and pressure histories provide experimental constraints on separate processes [42,44,75,76]; see [139] for a transient CFD analysis method Loaded area, orientation, propagation medium, opening time and structural period limit load extrapolation
Table 6. Sources and uses of representative validation data.
Table 6. Sources and uses of representative validation data.
Data source Main quantities available for comparison Use in the literature Conditions for data use
Moby Dick / water safety-valve tests [87,92] Mass flow rate, streamwise pressure and selected phase-state quantities Development of relaxation relations, subsequent safety-valve comparisons and analysis of thermal feedback in nozzles Distinguish relation development from independent safety-valve comparisons; outputs concern nozzle/channel flow
BNL converging–diverging water nozzle [89,90,91,92,93,97,103,107,108] Pressure and cross-sectional mean void fraction; some studies also compare radial void-fraction profiles Shared benchmark for several nonequilibrium models, with different comparison quantities in each study [89,91] share seven datasets; [107,108] use isothermal treatment and temperature-dependent parameter selection; other studies compare their respective tests and outputs
TOPFLOW depressurization series [105,106] Liquid temperature, void fraction, bubble diameter and their distributions Comparisons of TFM–PBM, interphase heat transfer and population-evolution relations with different source-term configurations The 2 MPa, 40% valve-opening test in [105] is reused as the third case in [106]; each study’s source-term configuration is reported separately
Crack, artificial-slit and orifice tests [35,36,39,125] Specimen geometry, total leakage rate and selected optical observations of exit morphology Assessment of geometry and leakage-source models; some openings under pressure are estimated computationally Retain geometry measurement conditions, specimen type and thermodynamic conditions; use local exit quantities according to what was observed
Morphology-adaptive cases without phase change [110,111] Bubble motion, interface morphology and stratified-flow dynamics Basic tests of multifield two-fluid coupling and interfacial momentum exchange Tests basic multifield coupling and hydrodynamics; flashing phase change requires separate validation
Spray, loaded-surface and humidity-sensor data [48,76,113,126] Size distributions, SMD and velocity, total target force, and humidity response at room temperature, measured separately Respectively address size distributions, spray outputs, applied force and sensor calibration Separate spray, loading and device datasets, each with its own fluid, measurement locations and statistics
Note: Data are grouped by facility or experimental series, with observables supplied by the individual studies. Groups include both different tests and reuse of the same data. The relationship between the data and parameter determination is specified by source; publication counts and counts of independent experimental sources should be distinguished.
Table 8. Factors affecting engineering responses and quantities used for their evaluation.
Table 8. Factors affecting engineering responses and quantities used for their evaluation.
Engineering response Main influencing factors Evaluation quantities and engineering relevance
Inventory loss Upstream state, effective break geometry, and boundary-condition histories Instantaneous and cumulative mass and energy release; comparison with system inventory and isolation timing
Thermal and humidity effects Outlet phase state, ambient conditions, droplet transport, entrainment, and phase change Equipment surface temperature, surface heat flux, and exposure duration; comparison with conditions for maintaining equipment function and for environmental qualification [142]
Leak detection Local signals, ambient background, sampling, and sensor dynamics Minimum detectable leak rate, detection probability, false-alarm rate, and alarm delay; assessment of the complete system against the design objectives of its licensing basis [141,143]
Net fluid load on the source Outlet gauge pressure and phase momentum fluxes, inlet contributions and momentum accumulation, and pressure on adjacent surfaces or flanges Net source load history and force impulse; calculation for the selected solid body and control-volume boundaries, with support reactions distinguished separately
Target impingement Jet spreading, stand-off distance, target size and orientation, back-face pressure, and flow past the edges Total target force and local pressure distribution; resultant pressure force obtained by integrating the front-to-back pressure difference over the area, with other stress contributions accounted for separately; comparison with design criteria for loading [142]
Dynamic structural response Spatial and temporal distribution of pressure loading, structural modal periods, and damping Pressure or force histories, pressure impulse (Pa·s) or force impulse (N·s), displacement, and strain; selection of dynamic analysis based on load duration, spatial distribution, and structural modes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.