Submitted:
22 November 2026
Posted:
25 November 2026
You are already at the latest version
Abstract
Objective. Electrocardiograms are not recorded at random: a clinician decides to order one. ECG prognosis benchmarks report a demographics baseline but not what the circumstances of recording predict alone. We asked how much of a published waveform arm's discrimination a model with no waveform recovers from acquisition context, and whether holding it fixed removes that arm's advantage. Approach. We audited a credentialed emergency-department benchmark of 129,057 ECGs from 71,098 patients, reproducing its published cohort and split, with a held-out fold of 6,439 ECGs from 3,644 patients. Nine nested arms and four numeric targets were declared in advance, acquisition context being nine features fixed at or before recording. Intervals are patient-clustered bootstraps; contrasts are paired and Holm-corrected. Main results. None of the four registered predictions was met at the endpoint it named. At the longest mortality horizon, acquisition context does not beat age and sex (-0.0216 [-0.0523, +0.0098]); it recovers 0.6803 [0.6149, 0.7476] of the waveform arm's above-chance discrimination against a registered 0.70; matching on four coarsened acquisition-context variables leaves that arm 0.9313 [0.6631, 1.1583] of its advantage against a registered 0.50; and a trend across four unscored horizons is -0.8000 [-1.0000, +0.2000]. At 24-hour ICU admission, an unregistered exploratory endpoint, the same nine features recover 0.9366 of that discrimination, of which triage acuity alone accounts for 0.8141. Significance. Acquisition context is a missing baseline in these benchmarks. It does not explain the waveform arm, and at short horizons it mostly reads triage acuity. Report it as routinely as demographics.
Keywords:
electrocardiography
; prognostic models
; benchmark evaluation
; informative presence
; shortcut learning
; calibration
1. Introduction
An electrocardiogram is not recorded at random. Someone decided to order it, at a particular point in a particular patient’s visit, under a local protocol and a particular reading of how sick that patient looked. A model trained on the resulting waveform inherits all of that as context, and the benchmarks used to evaluate such models do not measure it.
What they measure instead is a demographics baseline. On the benchmark we audit, the waveform arm reaches 0.8173 for ICU admission within 24 hours against 0.6017 for age and sex, and the gap reads as cardiac signal. But age and sex are not the only thing known before the electrocardiogram exists. The time from arrival to acquisition, the hour of day, the triage acuity, whether the patient has been in this department before: all of it is recorded, all of it precedes the waveform, and none of it appears in the baseline sets that ECG prognosis papers publish.
We asked how much of a published waveform arm’s discrimination a model with no waveform at all can recover from that acquisition context, and whether holding acquisition context fixed removes the waveform arm’s advantage. Both questions were registered, with numeric targets, before we ran the experiments that answer them.
Neither was met at the endpoint it named, and the failures are the substance of what follows. What survives is narrower and more useful. At short horizons a model that never sees a heartbeat comes close to the waveform arm, and none of the ECG prognosis benchmarks our search located reports the comparison that would show it; acquisition context does not explain the waveform arm, and those are two claims rather than one. Two further findings, neither of them planned, are about the benchmark itself.
Our contributions:
- An acquisition-context-only arm for a waveform prognosis benchmark, with the share of the waveform arm’s above-chance discrimination it recovers, at three horizons and against a registered target. A process-only arm has been run before in radiology, against a diagnostic rather than a prognostic target [1]; we know of no equivalent at a prognostic horizon, from timing, ordering and sequence variables, in any modality.
- A design that separates “a metadata model predicts the outcome” from “the waveform model is reading metadata”, by restricting the discrimination statistic to comparisons drawn from within one coarsened acquisition-context stratum. Those two questions have different answers here, and only the design distinguishes them.
- Four registered quantitative predictions with their measured values, none of them met at the endpoint it named.
- Two unplanned findings about the benchmark: its tabular arm dominates its waveform arm at every horizon, and its waveform arm’s probabilities are miscalibrated far enough that the unrecalibrated ensemble carries no net benefit over treating everyone at the threshold we declared.
2. Related Work
2.1. The Gap
The structured search behind this section, and the review of the four literatures it covered, are given in full in the Supplementary text. What that search did not locate is a study that fits a model on acquisition-process information alone and reports its discrimination against a signal model at a downstream prognostic outcome, in any modality. The nearest is [1], on a diagnostic target. Absence of evidence from a structured search is weak evidence of absence, and this one is bounded on three sides: “acquisition context” is this paper’s own term rather than an established one; an equivalent arm published as a non-imaging or clinical-variables-only baseline could sit outside every phrase searched; and the machine-learning-for-health proceedings, where audits of this kind also appear, are reachable here only through multidisciplinary indexes rather than through their own interfaces.
What those indexes do return is an independent argument for the same structural point, made from the opposite direction. An unreviewed position paper on ECG representation learning reports that across five pre-training approaches and six evaluation settings a randomly initialised encoder with linear evaluation matches state-of-the-art pre-training on many tasks, and argues from that for reporting a trivial baseline as a standing requirement [2]. It withholds training where this paper withholds the waveform, and it reaches the same conclusion about what these benchmarks do not report. The checkable claim, and the one made here, is that the baseline is missing from the benchmarks the field uses.
3. Methods
Figure 1 gives the whole design in one view: the cohort, the nine arms, the evaluation protocol and the four registered targets with what each returned.
3.1. Data and Cohort
We use MIMIC-IV-Ext-MDS-ED v1.0.0 [3,4], a credentialed benchmark derived from MIMIC-IV that assembles, for adult emergency department stays, the modalities available in the first 90 minutes after arrival: demographics, biometrics, vital-sign and laboratory trends, and a 12-lead ECG. It publishes 15 deterioration labels covering ICU admission at two horizons and mortality at seven. What we audit is the released data record rather than the paper describing it, and that distinction matters less than it did when this work began: the describing paper was a preprint then and has since appeared in Computers in Biology and Medicine, so both are now peer-reviewed. We reproduce its published cohort and its published 20-fold patient-stratified split without modification, training on folds 0 to 17, validating on fold 18 and testing on fold 19. Sex is used here as a model input and not as a stratifying variable. With age, it makes up the demographics baseline and enters every arm that includes demographics. No analysis was stratified by sex, and we did not examine whether any arm discriminates differently between sexes. The cohort is the benchmark’s, reproduced without any selection on sex.
The reproduced cohort holds 129,057 ECGs from 71,098 patients, and the test fold 6,439 ECGs from 3,644 patients. The release lists 129,095 records, so ours is 38 short, while patients and visits match the published counts exactly; Supplementary, Table S10 reconciles every count the release states against ours. Because the tabular arms drop rows where a label is undefined, the analysed sample differs slightly by label: 6,407 ECGs from 3,626 patients at a prevalence of 0.1260 for ICU admission within 24 hours, and 6,428 ECGs from 3,636 patients at 0.0422 and 0.1425 for 28-day and 365-day mortality.
One property of the benchmark’s construction constrains everything below. MDS-ED selects patients who had an ECG within roughly the first 90 minutes of arrival, so the cohort conditions on ECG presence. Presence versus absence is therefore not estimable inside it, and we obtain the superset needed for that question from MIMIC-IV-ED directly. On that superset, an acquisition-propensity model fitted as a diagnostic predicts early-ECG availability at 0.6764 on a held-out fifth of 425,011 adult stays, which establishes the premise this work rests on: the decision to record is itself substantially predictable. It is a diagnostic only and never selects or weights an evaluation row.
3.2. Acquisition Context
We define acquisition context as what is known about the circumstances of the recording, with no waveform samples. It is split into two blocks before any model is fitted, and the split is structural rather than a filter applied afterwards.
The pre-acquisition block holds nine features whose values are fixed at or before the moment of the index acquisition and cannot encode anything after it: time from ED arrival to acquisition, hour of day, day of week, month, triage acuity, the ECG’s sequence number within the stay, whether a prior ECG exists in the record, how long ago it was, and the count of prior ED visits. One of those nine is a clinician’s judgement rather than a circumstance of recording. Triage acuity is a severity assessment made at arrival, and the same objection we raise against row 5 below applies to its presence here. It stays in the block because the block was declared before any of these results existed and removing a feature after seeing them is not something a pre-specified analysis may do; what it is worth on its own is reported separately, because a declared set is not an argument that every member of it belongs. A second block was declared to hold four features that describe the index window and carry higher leakage risk. Three were built; the fourth, a cardiologist over-read flag, was probed at data access and dropped, because MIMIC-IV-ECG ships machine-generated statements and carries no separate human over-read marker. Table 1 profiles every feature in both blocks. The window variable with the most direct path to an ICU-admission label, care unit at acquisition, takes a single value across the entire cohort, because a benchmark that requires an ECG in the first 90 minutes of an emergency-department stay has already fixed where the patient is. Every feature carries an availability timestamp and a unit test that fails if that timestamp postdates the index time. The test passes on all 129,057 records and fails on each of the nine pre-acquisition features individually when they are deliberately poisoned. Day of week and month carry no information about local calendar practice, because de-identification shifts each patient’s dates by a random whole number of days; the Supplementary text gives the evidence, and no claim here rests on either.
Table 1.
Every declared acquisition-context feature, and what it can carry. Level counts over all 129,057 records of the reproduced cohort. A feature with one level carries no information, so it cannot be a leak whatever its availability stamp says, and it cannot be part of a confirmatory arm’s discrimination either. Both directions matter here: the ACQ_WINDOW block is where the leakage objection lives, and the ACQ_PRE block is what the confirmatory claim rests on.
Table 1.
Every declared acquisition-context feature, and what it can carry. Level counts over all 129,057 records of the reproduced cohort. A feature with one level carries no information, so it cannot be a leak whatever its availability stamp says, and it cannot be part of a confirmatory arm’s discrimination either. Both directions matter here: the ACQ_WINDOW block is where the leakage objection lives, and the ACQ_PRE block is what the confirmatory claim rests on.
| Feature | Block | Status | Carries information | Levels | Modal share | Undefined share |
|---|---|---|---|---|---|---|
| arrival_to_acquisition_minutes | ACQ_PRE | varies | yes | 90 | 0.0702 | 0.0000 |
| acquisition_hour_of_day | ACQ_PRE | varies | yes | 24 | 0.0728 | 0.0000 |
| acquisition_day_of_week | ACQ_PRE | varies | yes | 7 | 0.1450 | 0.0000 |
| acquisition_month | ACQ_PRE | varies | yes | 12 | 0.0861 | 0.0000 |
| triage_acuity | ACQ_PRE | varies | yes | 5 | 0.5198 | 0.0233 |
| ecg_no_within_stay | ACQ_PRE | varies | yes | 7 | 0.9397 | 0.0000 |
| prior_ecg_exists | ACQ_PRE | varies | yes | 2 | 0.6789 | 0.0000 |
| days_since_prior_ecg | ACQ_PRE | varies | yes | 70207 | 0.0064 | 0.3211 |
| prior_ed_visit_count | ACQ_PRE | varies | yes | 154 | 0.4468 | 0.0000 |
| n_ecgs_first_90min | ACQ_WINDOW | varies | yes | 7 | 0.8867 | 0.0000 |
| inter_ecg_interval_minutes | ACQ_WINDOW | varies | yes | 189 | 0.0605 | 0.8867 |
| care_unit_at_acquisition | ACQ_WINDOW | constant | no | 1 | 1.0000 | 0.0000 |
| cardiologist_overread_exists | ACQ_WINDOW | dropped | no | – | – | – |
care_unit_at_acquisition is constant because the benchmark admits only patients with an ECG inside the first 90 minutes of the ED stay, so the patient is in the Emergency Department at acquisition by construction. The benchmark’s own inclusion rule forecloses the leak the ACQ_WINDOW block was designed to isolate. cardiologist_overread_exists was declared in the block, probed at data access, and dropped: MIMIC-IV-ECG ships machinegenerated statements and carries no separate human over-read marker. It entered no run. Every ACQ_PRE feature varies. The confirmatory arm is fitted on nine features and all nine carry information.
Figure 2 sets out both blocks against the moment of acquisition, and which input block each arm sees.
The confirmatory claim rests on the pre-acquisition block alone. The window block is reported separately and labelled leakage-suspect, because it is the block that carries leakage risk, and the two are separated before anything is fitted rather than by a filter applied to results.
3.3. Arms
The nine nested input sets are:
| Row | Arm | Inputs |
| 1 | R1_prevalence | none; a constant predictor at the base rate |
| 2 | R2_demo | age and sex |
| 3 | R3_acqctx_pre | pre-acquisition context only, no signal |
| 3b | R3b_acqctx_window | pre-acquisition plus index-window context, leakage-suspect |
| 4 | R4_demo_acq | demographics plus pre-acquisition context |
| 5 | R5_tabular | the benchmark’s own 463 tabular columns: vital signs, laboratory analytes, biometrics and triage acuity |
| 6 | R6_waveform | the raw 12-lead waveform |
| 7 | R7_waveform_demo_acq | waveform plus demographics plus pre-acquisition context |
| 8 | R8_waveform_matched | row 6, scored within coarsened acquisition-context strata |
Rows 1 to 5 are gradient-boosted trees, tuned on the validation fold only with an identical 50-trial budget for every arm. Rows 6 and 7 use the benchmark’s own published architecture, read from its committed configuration rather than from its prose: a four-layer structured state-space model at model dimension 512, trained on 2.5-second crops at 100 Hz under focal binary cross-entropy summed across all 15 targets. Both waveform arms received the same four-candidate tuning search, and in both cases that search selected the published configuration. Every arm is trained at five seeds.
Row 5 is passed through from the benchmark without re-derivation, at exactly the 463 columns its own configuration declares. They are six vital signs (temperature, heart rate, respiratory rate, oxygen saturation, and systolic and diastolic blood pressure) and 45 laboratory analytes, each summarised nine ways over the observation window by mean, median, minimum, maximum, standard deviation, first value, last value, rate of change and a fitted linear coefficient; together with height, weight, body-mass index and the triage acuity assigned at arrival. Forty-five of the column names, being the nine summaries of each of five analytes whose names carry a comma, contain characters the tree library rejects, so names are sanitised at fit time under a map we assert to be injective. No value, ordering or missingness is touched.
One of those columns is not a physiological measurement. Triage acuity is a clinician’s judgement recorded at arrival, and it sits inside the arm the benchmark labels as clinical routine data. Row 5 is therefore not a physiology arm in the strict sense: its margin over the waveform arm is a margin over clinical routine data that includes a triage judgement, not over physiology alone.
3.4. Unit of Analysis
Three quantities in this work are all called an AUROC, and none may share a column with another.
The published evaluation protocol is crop level. At validation and test each 10-second record is cut into four non-overlapping 2.5-second crops and each is scored as an independent row, giving roughly four rows per ECG. We established this from the benchmark’s model code rather than from its paper, and we use it for one thing only: the reproduction comparison against the published figure.
Every cross-arm contrast instead uses a record-level score, one row per ECG, obtained by averaging the four crops’ sigmoids. Rows 1 to 5 have no crops, so a crop-level waveform number and a tabular number are not comparable quantities.
Row 8 is a within-stratum concordance, described below, in which most positive-negative pairs do not contribute at all. It is a third quantity again, and it has its own panel rather than another row of the main table.
3.5. Holding Acquisition Context Fixed
Row 8 asks whether the waveform arm’s advantage over demographics survives when acquisition context is held fixed. It forms coarsened exact strata on four pre-acquisition variables, arrival-to-acquisition delay in four buckets, hour of day in four, the recorded day split Monday to Thursday against Friday to Sunday, and triage acuity as recorded with missing as its own level, giving 143 non-empty strata over the test fold. One of those four does not control what its name suggests, for the reason given above: the weekday recorded in this dataset is not the true weekday. The matching therefore holds three informative variables fixed and splits on a fourth that is noise, which costs effective pairs without removing a source of confounding. The specification stands as declared, so row 8 conditions on three informative variables.
The discrimination statistic then counts only positive-negative pairs drawn from the same stratum, so no compared pair differs in acquisition context, and per-stratum statistics are pooled by their pair counts. Strata contributing no discordant pair contribute nothing and are reported as such. Row 8 trains nothing: it is row 6, unchanged, under this statistic. The unmatched comparison is computed on the same records, so the only difference between the matched and unmatched figures is the pair restriction rather than which records were kept. Comparing a restricted statistic on informative strata against a plain statistic on the whole fold would confound the restriction with a selection effect.
We validated the statistic before using it, on synthetic data with a fixed seed, and Supplementary, Table S3 reports what the controls measured. It reproduces a plain AUROC exactly on a single stratum and is unchanged by duplicating every row. On a score that is constant within every stratum it returns 0.5000 while that same score reaches 0.7406 unstratified, which is the collapse a statistic that failed to restrict its pairs could not produce. On a score that is part stratum shortcut and part real signal it sits strictly between the two.
3.6. Statistical Protocol
All intervals are patient-clustered percentile bootstrap intervals over 10,000 resamples, resampling on subject_id. Records from one patient are drawn or omitted together, because a patient may contribute several ECGs and treating those as independent would understate every interval. Group counts are reported with every number.
Every contrast is a paired clustered bootstrap on the difference itself, with both arms scored on the same resampled patients within each replicate. We never treat overlapping marginal intervals as evidence of no difference. Quantities that are not differences of two AUROCs, namely the recovery ratio, the Spearman trend across horizons, the expected calibration error and net benefit, carry intervals taken on the quantity itself: patients are resampled once and the whole quantity is recomputed on that draw, rather than assembled from the endpoints of separate intervals.
The registered decision rules are read on the point estimate. A target is met when the quantity itself reaches the declared value; the interval is reported beside it and was not part of the rule. Where a point estimate falls short of its target and the interval spans that target, the target is not met under the declared rule, and the evidence does not establish that the true value lies below the target either.
The noise floor is a table, not a number. It is the seed-to-seed spread of each cell’s own five runs, indexed by arm and label, and a difference not clearly larger than the spread of its own arms at its own label is reported as no difference. This matters because the waveform arm is substantially noisier than the tabular arms: its record-level spread runs from 0.0091 to 0.0190 across the three reported labels, against 0.0024 to 0.0049 for demographics. A single scalar floor would misjudge one of them by a factor of several.
3.7. Multiplicity
Two families of tests exist. We correct them separately and never pool them.
The audit family comprises five contrasts crossed with three labels, a family of 15 tests corrected by Holm at that size. Correction was applied at the declared size even while three of its members awaited row 8, which is conservative and cannot cost a conclusion when the family fills up: with the size held fixed, adding tests can only lower an existing adjusted value.
The horizon ladder is a separate registered family of six tests with its own Holm correction. Its primary test is restricted to the four mortality horizons no arm had been scored on at the time the hypothesis was formed, because the hypothesis was generated by the other two. The same statistic over all six horizons is reported as a secondary quantity only.
3.8. Calibration and Net Benefit
Calibration is the standard casualty of reporting discrimination alone [5]. We compute expected calibration error at 15 bins under both equal-width and equal-mass binning, with reliability curves. Equal-mass bins keep tied scores together. Splitting a run of identical predictions across bins gives each of those bins a different observed rate from sampling noise alone, which manufactures apparent miscalibration in a constant predictor, which is visible on the prevalence-floor arm.
The reference for a calibrated arm is not zero. At this bin count and sample size a perfectly calibrated score still shows a non-zero ECE, so each cell carries a simulated null band obtained by drawing labels repeatedly from the arm’s own predicted probabilities. An ECE inside that band is not evidence of miscalibration, and an arm counts as calibrated only if it sits inside the band under both schemes.
Net benefit follows the original decision-curve formulation [6], read under the interpretive standard its own author later had to write because the curves were being misread [7], and acting when predicted risk is at least the threshold. The operating threshold is 0.10 (Registration), quoted at 24-hour ICU admission alone, the only reported label with an action available at ED disposition.
Net benefit reads the probability scale where AUROC reads only the ranking, so a poor net benefit for an arm whose probabilities are inflated is a finding about that probability scale rather than about discrimination. We perform no recalibration: only test-fold predictions are retained, and fitting a recalibrator on the fold that reports the result would be circular.
3.9. Registration
We describe this work as pre-specified rather than pre-registered. No third party holds a timestamped copy of the protocol. What exists is a set of comparison files committed to a version-controlled repository before the runs they govern. Those files are in the archive named under availability of data and materials, reproduced there byte for byte with their checksums, and the dates below are what they were committed on.
The nine arms, the audit family of fifteen tests and the numeric targets for that family were declared in one comparison file committed at 13:26 on 23 August 2026, one hour before the first run of any arm was registered. Neither those targets nor the family size changed afterwards.
The horizon-ladder family was declared later and was not arrived at the same way. The pattern it tests was suggested by two labels that had already been scored, 28-day and 365-day mortality. We wrote it into a second comparison file, committed on 24 August 2026, and restricted its primary test to the four mortality horizons on which no arm had then been scored. Those four were first scored on 3 September, ten days afterwards. The family is therefore pre-specified with respect to the data it is tested on and generated with respect to the data that suggested it, which is why the version computed over all six horizons is reported as a secondary quantity carrying no verdict.
Two later decisions were fixed before the analyses that depend on them, and the pipeline enforces that order rather than checking it afterwards. The matching specification, which fixes which four features are coarsened and how, was settled on 2 September; the matched arm first ran on 3 September, and the script that builds it refuses to start while that decision is open. The operating threshold of 0.10 was settled the same day and before any decision curve was computed, and the decision-curve script likewise refuses to run against an unsettled threshold.
3.10. Ethics, Data Use and Availability
MIMIC-IV and the derivatives used here are de-identified under a HIPAA-compliant process. Collection of the source data was approved by the institutional review board of the Beth Israel Deaconess Medical Center, which granted a waiver of informed consent because the records are retrospective and de-identified. Access is credentialed: the author completed the required human-subjects research training and is party to the PhysioNet Credentialed Health Data Use Agreement, under which redistribution of row-level data is not permitted. No individual record, prediction or stratum assignment is released with this work.
4. Results
4.1. The Waveform Reproduction
Our reproduction of the waveform-only arm reaches a macro AUROC of 0.8474 over all 15 deterioration targets under the published crop-level protocol. Two published versions of the benchmark report this arm differently, and we compare against both. The version of record gives 0.8565 with interval [0.8410, 0.8707], and our gap against it is -0.0091. The earlier preprint, which was the only figure available when this reproduction was first judged, gives 0.8279 with interval [0.8047, 0.8511], and our gap against it is +0.0195. Both gaps fall inside their published intervals (Table 2). They fall on opposite sides of the published point estimate, so nothing in this paper rests on the direction of the reproduction gap.
The published interval is wide because six of the fifteen deterioration targets carry fewer than fifty positives in the test fold and the unweighted macro gives each the same weight as targets carrying over eight hundred. A pass is evidence the reproduction is not badly wrong, not that it is precisely right.
R7_waveform_demo_acq is shown against the same published figures for scale only; it reproduces nothing.
Both published intervals are wide, the version of record’s running from 0.8410 to 0.8707, because six of the fifteen targets carry fewer than fifty positive ECGs in the test fold, two of them only nine, while the unweighted macro gives each the same weight as targets carrying over eight hundred. Landing inside it bounds the reference arm rather than pinning it.
At record level, one row per ECG, the same arm reaches 0.8545. Nothing is published at that unit, so it has no gap; it is the figure every cross-arm comparison below uses.
4.2. Acquisition Context Alone Predicts Deterioration Well at Short Horizons
Table 3 and Figure 3 give the nested ladder at record level. A model given only the nine pre-acquisition features, with no waveform samples at all, reaches 0.7972 [0.7806, 0.8138] for ICU admission within 24 hours, 0.7587 for 28-day mortality and 0.7241 at one year.
Row 8 is not a row here. It is a within-stratum concordance over restricted pairs, a different estimand from a record-level AUROC, and it has its own panel in Supplementary, Table S1.
Sample: ICU admission, 24h: 6,407 ECGs, 3,626 patients, prevalence 0.1260; Mortality, 28d: 6,428 ECGs, 3,636 patients, prevalence 0.0422; Mortality, 365d: 6,428 ECGs, 3,636 patients, prevalence 0.1425.
Against age and sex, the baseline these papers do report, the acquisition-context arm is far ahead at the short horizon and behind at the long one. The paired difference at 24-hour ICU admission is +0.1955 [+0.1649, +0.2267], roughly forty times that cell’s seed-to-seed spread of 0.0049, so it is not a seed artefact. At 28 days it is +0.0624.
At 365-day mortality, the registered primary endpoint, it is -0.0216 [-0.0523, +0.0098]. The interval crosses zero. Acquisition context does not beat age and sex there, and that is the first of four registered failures reported here.
4.3. The Recovery Ratio at the Registered Endpoint
The registered primary quantity is the recovery ratio, the share of the waveform arm’s above-chance discrimination that an arm without the waveform recovers, (AUROC - 0.5) / (AUROC_waveform - 0.5), where 0.5 is chance, with the denominator taken at the same label and the interval taken on the ratio itself. The registered target was at least 0.70 at the longest mortality horizon.
It is 0.6803 [0.6149, 0.7476]. The point estimate sits below target and the interval spans it, so the target is not met. Supplementary, Table S9 gives the ratio for every arm at every reported horizon.
At the other two labels the ratio does clear its 0.70 target: 0.9366 [0.8758, 0.9995] at 24-hour ICU admission and 0.7448 [0.6515, 0.8382] at 28 days. Both are exploratory: neither is the registered endpoint.
4.4. The Horizon-Ladder Hypothesis Is Not Supported
The pattern above, acquisition context dominating demographics at short horizons and losing at long ones, was generated by the two labels that produced it. It forms a separate registered family, tested on the four mortality horizons no arm had been scored on, which Table 4 reports. Across those four the per-horizon advantage peaks at seven days rather than falling throughout: it rises from +0.0946 at one day to +0.1224 at seven, then falls to +0.0161 at ninety and +0.0030 at one hundred and eighty.
This family is corrected separately from the audit family (Supplementary, Table S4) and the two are never pooled. No test carries an adjusted p in both. The trend statistic is -0.8000 [-1.0000, +0.2000] with a Holm-adjusted p of 0.708. Because the interval includes zero, the hypothesis is not supported. A rank correlation over four points can take only a handful of values, which is why the point estimate is strongly negative while the interval stays wide, and that is a limitation of the statistic we registered rather than of its implementation. Computed on the ordering alone, the correlation reads as strong on a sequence that rises before it falls.
Computed over all six horizons, including the two that generated the hypothesis, the same statistic reaches -0.9429 [-1.0000, -0.1429] with a raw p of 0.0026. It is a secondary quantity and carries no verdict: the pattern is convincing on the two labels that generated it and not on the four the hypothesis was registered against. Figure 4 plots the advantage against horizon, with the two generating labels marked apart from the four the test was run on.
4.5. The Waveform Advantage Survives within Acquisition-Context Strata
The second registered target concerned row 8. We predicted that restricting comparisons to record pairs drawn from the same coarsened acquisition-context stratum would cost the waveform arm at least half its advantage over demographics. What the restriction holds fixed is four coarsened variables of the nine, one of which carries no information (Methods, Acquisition context), and it retains 0.0155 to 0.0199 of the available positive-negative pairs, at a worst standardised mean difference of 0.3881 on the five it leaves free. It costs between 7 and 22 percent of it under one reading of our own formula and between 32 and 45 percent under the other, and both readings miss the target.
The gain retained is 0.7846 [0.6308, 0.9259] at 24-hour ICU admission, 0.8643 at 28 days, and 0.9313 [0.6631, 1.1583] at one year, against a declared target of at most 0.50. Our declared formula was ambiguous about which demographics figure the numerator uses. Table 5 reports both readings; they differ substantially and agree on the verdict at every label.
The prediction was that holding acquisition context fixed would cost the waveform arm at least half its advantage over demographics. Under the within-stratum reading of the numerator it costs between 7 and 22 percent of it; under the unstratified reading, between 32 and 45 percent. The point estimate misses the declared target under both. Under the second reading the intervals at 28 days and at one year include 0.50, so at those two labels the evidence does not settle which side of the target the truth lies on; what is established is that the target is not met under the declared rule, which is read on the point estimate. The design is doing what it claims, and it is the collapse of a different arm that demonstrates it. Within a stratum the acquisition-context arm falls from 0.7888 to 0.6042 at ICU admission, because four of its nine features are the matching variables. Demographics barely moves, from 0.6026 to 0.5796, since age and sex are only weakly related to acquisition context. The waveform arm moves from 0.8152 to 0.7464. A statistic that failed to restrict its pairs could not produce that pattern.
So the waveform arm keeps most of its advantage among patients whose acquisition context matches on the four coarsened variables the strata are built from, three of which carry information. That is the scope of the result. Five of the nine declared features are not held fixed, the four that are held fixed are coarsened into bins rather than matched exactly, and the acquisition-context arm still reaches 0.6042 within strata at 24-hour ICU admission, so context is not exhausted by the conditioning. What the design rules out is that the waveform arm’s advantage is mostly carried by this representation of acquisition context; a finer one is not tested here.
4.6. Two Findings Outside the Registered Analysis
The benchmark’s own tabular arm beats its waveform arm at every horizon, and the benchmark reports the same direction itself. Its appendix gives clinical routine data against ECG waveforms only at 0.8809 against 0.7443 for 24-hour ICU admission, 0.8858 against 0.7859 at 28 days and 0.8579 against 0.7999 at one year [3]. What is added here is the same comparison at a per-label unit, with both arms tuned to their own budget and with patient-clustered intervals on the difference. Vital signs and laboratory values reach 0.9164 at 24-hour ICU admission, 0.9102 at 28 days and 0.8533 at one year, against 0.8173, 0.8473 and 0.8294. The gap is narrower here than in the published table at all three horizons: our waveform arm scores above the published waveform figure everywhere, while our tabular arm is above the published tabular figure at the two shorter horizons and marginally below it at one year. On the recovery-ratio scale it exceeds the waveform arm’s above-chance discrimination everywhere: 1.3122, 1.1811 and 1.0726.
Demographics plus acquisition context is statistically indistinguishable from the waveform arm at 24-hour ICU admission. The paired difference is -0.0080 [-0.0276, +0.0115], and it does not clear that cell’s noise floor of 0.0091. It is the only one of the twelve record-level contrasts that fails to clear its own floor. That is an absence of evidence for a difference at this sample size, not evidence that the two arms are equivalent: the interval is wide enough to contain differences in either direction that would matter, and we did not design an equivalence test or declare a margin for one. The declared family holds fifteen tests; the other three compare the matched arm against the waveform arm and are a within-stratum concordance, for which the seed-to-seed spread of a record-level AUROC is not the right reference and none is reported. Supplementary, Table S5 carries all fifteen and shows which twelve have a floor.
4.7. What the Acquisition-Context Block Is Made of
Most of what the acquisition-context arm reads at the short horizon is triage acuity, and the rest of the block still adds to it. A model given that one feature and nothing else reaches 0.7583 [0.7410, 0.7755] at 24-hour ICU admission, against 0.7972 for all nine and 0.6017 for age and sex. The other eight features are worth +0.0389 [+0.0310, +0.0467] there as a paired difference on the same patients, +0.0467 at 28 days and +0.0943 at one year, every interval excluding zero. So the block is neither reducible to acuity nor separable from it.
Read on the recovery scale, where this paper’s headline is quoted, the single feature accounts for most of the short-horizon figure and much less of the registered one. Acuity alone recovers 0.8141 [0.7547, 0.8754] of the waveform arm’s above-chance discrimination at 24-hour ICU admission, against 0.9366 for all nine. At one year, the endpoint the registration named, it recovers 0.3940 [0.3331, 0.4574] against 0.6803 for all nine. The short-horizon result is therefore largely a restatement of a quantity emergency medicine already has, and the registered one is not; neither was met. This arm was added after every other result existed; it is exploratory, belongs to no multiplicity family, and is reported in Supplementary, Table S13.
4.8. The Waveform Arm’S Probabilities Are Inflated
Everything above reads a ranking. Calibration reads the probability scale, and the two disagree here.
The waveform arm predicts a mean risk of 0.2502, under the loss the committed configuration selects rather than the one the published prose names, against an observed rate of 0.1260, giving an expected calibration error of 0.1347 [0.1259, 0.1428] under equal-mass binning, against a null band reaching only 0.0224. The tabular arms sit far closer to their observed rates, and the constant prevalence-floor arm sits inside its band under both binning schemes. That is a fact about this cohort rather than a necessity: a constant predictor set at one sample’s prevalence is calibrated in another only to the extent that the two prevalences agree. Supplementary, Table S17 reports the mean predicted risk, the observed rate and the expected calibration error for every arm and label under both schemes.
The expected calibration error gives the size of the disagreement and not its shape, so we report the two quantities that do. The waveform arm’s calibration intercept at 24-hour ICU admission is -0.8818 [-0.9737, -0.7963]: far below zero, so it over-predicts, and the interval excludes zero. Its calibration slope is +2.4717 [+2.2687, +2.6854]: far above one, so the probabilities it does produce are packed into too narrow a range, and the interval excludes one. The acquisition-context arm is calibrated on both axes at the same label, with an intercept of +0.0366 [-0.0622, +0.1299] and a slope of +1.0158 [+0.9389, +1.0997], each interval containing its null. Supplementary, Table S16 gives all three quantities, including the Brier score, for every arm and label. The pattern holds at every label: the two waveform arms are the only ones whose intervals exclude both nulls.
Figure 5 shows the shape of it. The waveform arm lies well below the diagonal across the whole range and under both binning schemes, so it assigns a higher risk than the observed rate at almost every level of predicted risk, while the tabular and acquisition-context arms track the diagonal.
4.9. Net Benefit at the Registered Threshold
Table 6 reports net benefit for every arm at the registered threshold of 0.10, where treating everyone scores 0.0288 and treating no one scores exactly zero. The waveform arm scores 0.0334 [0.0220, 0.0449] while flagging 0.9575 of patients, which at this threshold makes it close to treating everyone. The acquisition-context arm scores 0.0653 flagging 0.4077, and the tabular arm 0.0897 flagging 0.2397. Figure 6 gives the curves across the whole threshold grid, against treat-all and treat-none.
Net benefit reads the probability scale rather than the ranking, so this ordering is not a discrimination ordering: an arm that ranks cases well loses at a fixed threshold when its probabilities are inflated. No recalibration was performed; only test-fold predictions are stored, and refitting on them would be circular.
The ordering here follows from the probability scale rather than from discrimination: an arm whose probabilities run from about twice to about three and a half times the observed rate crosses any fixed low threshold for almost everyone, however well it ranks. A recalibrated waveform arm would very likely place differently, and recalibration was out of scope (Methods, Calibration and net benefit).
4.10. The Registered Outcomes
Table 7 sets the four registered predictions against what they measured.
The recovery ratio clears 0.70 at the two labels that were not the pre-declared endpoint (Supplementary, Table S9); both are reported as exploratory.
The retained-gain target is missed at all three labels and under both readings of its ambiguous formula (Table 5), not only at the endpoint shown here. Under the second reading the intervals at 28 days and at one year contain the target, so at those two the evidence is inconclusive rather than contrary; the outcome column reports the declared rule, which is read on the point estimate.
5. Discussion
5.1. A Missing Baseline, and Four Targets That Missed
Two claims were registered: that a model given only ECG acquisition context recovers at least 70 percent of the above-chance discrimination of a published waveform arm, and that the waveform arm’s advantage over demographics shrinks when acquisition context is held fixed. Neither held at the endpoint it named, the horizon-ladder trend was not supported, and nor was the prerequisite contrast against demographics (Table 7); the recovery ratio at the longest mortality horizon is 0.6803 against a target of 0.70. What survives is narrower. At the two labels the registration did not name, a model with no waveform samples recovers most of that above-chance discrimination, 0.9366 of it at 24-hour ICU admission. Those results are exploratory, and what they show is that acquisition context is a baseline these benchmarks are missing, which the search behind this paper found no ECG prognosis study reporting.
Most of the short-horizon figure is not new. Triage acuity alone recovers 0.8141 [0.7547, 0.8754] at 24-hour ICU admission, and the discrimination of a five-level triage score for short-term deterioration is an established quantity in emergency medicine rather than a finding of this paper. What the other eight features add there is +0.0389, small and clearly non-zero. The share does not hold across horizons: at one year acuity alone recovers 0.3940 against 0.6803 for all nine, so most of what the block reads at the long horizon is not acuity. The honest summary is that the short-horizon number is largely a triage score in different clothing, that the long-horizon number is not, and that the long-horizon number is the one the registration named and the one that missed its target.
The practical consequence does not depend on the failed targets. If a benchmark reports a waveform arm against a demographics baseline and nothing else, a reader has no way to distinguish a model that has learned cardiac physiology from one that has partly learned a triage protocol. Adding the nine-feature acquisition-context arm costs minutes of processor time and settles the question for that cohort. It should be reported as routinely as the demographics baseline now is.
5.2. Acquisition Context Does Not Explain the Waveform Arm
That an acquisition-context arm recovers most of the waveform arm’s discrimination and that the waveform arm is reading metadata are two separate claims, and only the first survives.
Row 8 is the evidence. Restricting the discrimination statistic to positive-negative pairs drawn from the same coarsened acquisition-context stratum, so that no compared pair differs in acquisition context, leaves the waveform arm with 0.7846 of its advantage over demographics at 24-hour ICU admission and 0.9313 at one year. It loses between 7 and 22 percent of that advantage under the reading that keeps numerator and denominator on one statistic, and 32 to 45 percent under the more literal reading of a formula we wrote ambiguously. Neither is the half or more we predicted. Whatever the waveform arm is reading, it is not mostly what this matching holds fixed: four coarsened features out of the nine declared. That is a narrower statement than “not the decision to record the ECG”, and it is the one the design supports, because the acquisition-context arm remains well above chance within the strata.
So an acquisition-context model can recover most of a waveform model’s discrimination without the waveform model depending on acquisition context. The likely resolution is that the two models read correlated but separable things: acquisition context and cardiac signal both track how sick a patient is, and each carries information the other does not. That reading is consistent with the shared-pathophysiology account of AI-ECG non-specificity [8], so the matched arm is evidence for that account rather than against it.
5.3. Calibration Changes What the Numbers Can Be Used for
The waveform arm’s probabilities are inflated at every label, by a factor of about two at 24-hour ICU admission and at one year and by about three and a half at 28 days. It predicts a mean risk of 0.2502 against an observed 0.1260, with an expected calibration error of 0.1347 against a null band reaching 0.0224.
This is a property of how the arm was trained and scored rather than of the signal it found. It was fitted under focal binary cross-entropy, which reweights examples and moves the probability scale by design, and its reported score is averaged over four crops and then over five seeds. The consequence at a fixed decision threshold is severe: at 0.10 the waveform arm flags 0.9575 of patients, so its net benefit of 0.0334 sits barely above the 0.0288 of treating everyone. That ordering describes the probability scales as published, not the best achievable utility of each arm.
What the calibration result establishes is narrower still. A published prognostic arm can carry strong discrimination and, as an unrecalibrated ensemble evaluated at one declared threshold, probabilities that yield no net benefit over treating everyone; and a paper reporting only AUROC gives no way to see it. What it does not establish is that the underlying model is unusable.
6. Limitations
Every number here comes from one hospital system’s emergency department, and acquisition context is a description of local practice, so the arm that reads it is fitted to that practice. Who receives an early ECG at Beth Israel Deaconess, how quickly, and how triage acuity is assigned are institutional decisions embedded in a particular staffing model: a site that orders ECGs more liberally would compress the informative variation this arm reads, and a site that orders them more selectively would widen it. We would expect the direction to replicate and not the magnitude. Whether a model fitted here transfers to a department with a different ordering protocol is untested, and the external replication that would settle it was not performed.
The benchmark conditions on early-ECG presence, so presence versus absence, arguably the sharpest form of the acquisition question, is not estimable inside it (Methods, Data and cohort). What the arm reads is when and in what circumstances an ECG was taken among patients who all had one.
What motivated the second half of the hypothesis is imported. The pattern comes from a different cohort in a different health system with its own label definitions [9], where it is visible in the published numbers but never named or analysed. It is the reason we looked, not evidence for what we found, and the test registered on this cohort does not support it.
The matched arm holds a coarsened version of four variables rather than the whole block, and the remaining five pre-acquisition features are not held fixed at all. Coarsening leaves 0.0993 standardised mean difference inside the bins, on the underlying continuous scale, and the five that are free are not balanced by the matching either, at a worst standardised mean difference of 0.3881 after pair weighting. Matching on acquisition context, in this design, means matching on four coarsened variables and nothing else. A finer match would hold more fixed and would also empty more strata; it was not re-run at other coarsenings, because choosing the coarsening after seeing its effect on the result is what fixing the specification in advance was for.
The reproduction gate is easy to pass, because the published figure is an unweighted macro over 15 targets of which six carry fewer than fifty positives in the test fold. Every recovery ratio here divides by that reference arm, so each one inherits the looseness: the denominator is bounded rather than pinned, and the two published versions of the benchmark put our reproduction on opposite sides of their reported figure without either placing it outside the interval.
The horizon-ladder test is underpowered by construction, and its interval stays coarse however many resamples are drawn (Results, The horizon-ladder hypothesis is not supported). The statistic was fixed before the test.
Calibration and net benefit describe a seed ensemble rather than a model. The scored probability is a mean across five seeds, and for the waveform arms a mean across four crops before that, and averaging probabilities compresses them toward the middle.
The tuning budgets are not equal across arms, and the inequality has a direction. Each tabular arm was tuned per target over fifty trials; the two waveform arms were tuned over four candidate configurations at twelve epochs each, selected on a validation macro across all fifteen deterioration targets at once rather than on the label being reported. Every contrast in this paper that sets a tabular arm against a waveform arm therefore compares a per-target-tuned model against a shared multi-task one, and bounds the waveform arm from below rather than estimating it. That applies to the tabular arm’s margin over the waveform arm, and to the finding that demographics with acquisition context are not separable from the waveform arm at 24-hour ICU admission.
It applies to the recovery ratio as well, and in the direction that flatters this paper. The ratio divides a per-target-tuned tabular arm by a waveform arm selected once across fifteen targets, so its numerator is favoured and every recovery ratio we report is an upper estimate of what a comparably tuned waveform arm would give. That includes the registered primary, where a smaller true ratio would only make an already failed target fail by more, and the two exploratory cells that clear 0.70, where it cuts the other way. The matched comparison is unaffected: both of its arms are waveform-based. We bound the tabular half of the inequality by refitting rows 3 and 4 under a single shared configuration selected the way row 6’s was, from the same four candidates on the same fifteen-target validation macro, and it moves every recovery ratio by under a hundredth, slightly upward (Supplementary text), which is within what the seeds alone move these arms. That bounds one side, and it turns out to be worth almost nothing. Closing the other would take a per-target waveform arm at a comparable budget, which we did not fit, so how much the inequality is worth in total is not settled here. The waveform arm is audited as published rather than as maximally tuned, which is the appropriate object for an audit of a published benchmark.
The committed configuration also departs from the benchmark’s own description on the loss. It selects a focal binary cross-entropy, while the published prose names plain binary cross-entropy, and we reproduced the configuration as committed. The calibration finding rests on that choice, and a waveform arm trained under the loss the prose describes might sit differently on the probability scale while ranking much as this one does.
Finally, the novelty claim is bounded by what was searched: one screener, no Scopus or Web of Science, English only, and the machine-learning-for-health proceedings reached through multidisciplinary indexes rather than their own interfaces (Related work, The gap). Such an arm could exist as an unlabelled ablation in a supplementary table, or in a venue these searches did not reach. Two of the works cited are unreviewed preprints, [10] and [2], admitted because each is the best available evidence for the point it is cited for and labelled as unreviewed where each appears.
7. Conclusions
We registered four numeric predictions about ECG acquisition context and none was met at the endpoint it named. A model given only the circumstances of the recording does not beat age and sex at one-year mortality; it recovers less of the waveform arm’s above-chance discrimination there than we predicted; holding acquisition context fixed, on the four coarsened features the matching uses, leaves the waveform arm with most of its advantage rather than half of it; and a trend registered across four further horizons is not supported.
What survives is smaller and checkable. Acquisition context is a baseline that ECG prognosis benchmarks do not report and, on this cohort, should: features known before the electrocardiogram exists recover most of a published waveform arm’s above-chance discrimination at 24-hour ICU admission, a label we did not register. Most of that short-horizon figure is triage acuity, a quantity emergency medicine already has; the other eight features add to it at every label. That is a reporting recommendation rather than an indictment, and the matched arm is why. Two things we did not set out to measure may matter more to users of this benchmark, one of which it reports about itself: its tabular arm beats its waveform arm at every horizon we report, and that arm’s probabilities, under the loss its committed configuration selects rather than the one its prose names, are inflated at every label, by a factor of about two at two of the three and about three and a half at the third, which a table of AUROCs cannot show.
Acquisition context is a description of local practice, so what decides whether any of this generalises is a second site with a different ordering protocol. Until that is done the scope of this work is one emergency department, one benchmark, and a baseline that was missing from both.
Supplementary Materials
The following supporting information can be downloaded at the website of this paper posted on Preprints.org.
Author Contributions
A.S. (Anay Sinhal) conceived the study, designed the experiments, implemented the evaluation pipeline and all models, conducted the analysis, and wrote the manuscript. The author read and approved the final version.
Funding
No external funding was received for this study.
Data Availability Statement
The benchmark, the parent datasets and the published split are available from PhysioNet to credentialed users under the PhysioNet Credentialed Health Data Use Agreement. Everything this paper adds is archived at https://doi.org/10.5281/zenodo.22732984 and developed at https://github.com/anayy09/ecg-acquisition-context-audit: the pipeline, the configuration for every arm, the comparison files that declared the analysis before it ran, one record per registered run with its configuration, commit and data hashes, and the aggregate tables and figures every number in this manuscript is read from. One command regenerates those tables and figures from the archived results, without credentialed data and without a GPU. Aggregate artifacts are released in full; anything at the level of a record stays behind the data use agreement, which is why the archive holds a hash and a row count for each prediction file rather than the predictions themselves.
Acknowledgments
Not applicable.
Conflicts of Interest
The author declares no competing interests.
References
- Badgeley, M.A.; Zech, J.R.; Oakden-Rayner, L.; Glicksberg, B.S.; Liu, M.; Gale, W.; McConnell, M.V.; Percha, B.; Snyder, T.M.; Dudley, J.T. Deep learning predicts hip fracture using confounding patient and healthcare variables. npj Digit. Med. 2019. [Google Scholar] [CrossRef]
- Berger, Z.; Prakah-Asante, D.; Guttag, J.; Stultz, C.M. Position: Evaluation of ECG Representations Must Be Fixed. arXiv 2026. [Google Scholar] [CrossRef]
- Lopez Alcaraz, J.M.; Bouma, H.; Strodthoff, N. Enhancing clinical decision support with physiological waveforms — A multimodal benchmark in emergency care. Comput. Biol. Med. 2025. [Google Scholar] [CrossRef]
- Lopez Alcaraz, J.M.; Strodthoff, N. MIMIC-IV-Ext-MDS-ED: Multimodal Decision Support in the Emergency Department, a Benchmark Dataset for Diagnoses and Deterioration Prediction in Emergency Medicine, version 1.0.0. PhysioNet 2024. [Google Scholar] [CrossRef]
- Van Calster, B.; McLernon, D.J.; van Smeden, M.; Wynants, L.; Steyerberg, E.W. on behalf of Topic Group "Evaluating diagnostic tests.; prediction models" of the STRATOS initiative. Calibration: the Achilles heel of predictive analytics. BMC Med. 2019. [Google Scholar] [CrossRef]
- Vickers, A.J.; Elkin, E.B. Decision curve analysis: a novel method for evaluating prediction models. In Medical Decision Making; 2006. [Google Scholar] [CrossRef]
- Vickers, A.J.; van Calster, B.; Steyerberg, E.W. A simple, step-by-step guide to interpreting decision curve analysis. In Diagnostic and Prognostic Research; 2019. [Google Scholar] [CrossRef]
- Croon, P.M.; Dhingra, L.S.; Biswas, D.; Oikonomou, E.K.; Khera, R. Phenotypic selectivity of artificial intelligence-enhanced electrocardiography in cardiovascular diagnosis and risk prediction. Circulation 2025. [Google Scholar] [CrossRef]
- Sun, W.; Kalmady, S.V.; Sepehrvand, N.; Salimi, A.; Nademi, Y.; Bainey, K.; Ezekowitz, J.A.; Greiner, R.; Hindle, A.; McAlister, F.A.; et al. Towards artificial intelligence-based learning health system for population-level mortality prediction using electrocardiograms. In npj Digital Medicine; 2023. [Google Scholar] [CrossRef]
- Lucafo, G.D.; da Costa Silva, R.; Sarcinelli, J.L.L.L.; De Mitri, A.G.; Silva, D.F. CLIC: Contextual Language-Informed Cardiac Pathology Classification. arXiv 2026. [Google Scholar] [CrossRef]
Figure 1.
The study design. a, the cohort, reproduced from the released benchmark without modification, and the separate emergency-department denominator used only for the acquisition-propensity diagnostic. b, the nine pre-declared arms, grouped by what they see, with the role each was declared under. c, the evaluation protocol. The four registered targets and what each returned are Table 7.
Figure 1.
The study design. a, the cohort, reproduced from the released benchmark without modification, and the separate emergency-department denominator used only for the acquisition-propensity diagnostic. b, the nine pre-declared arms, grouped by what they see, with the role each was declared under. c, the evaluation protocol. The four registered targets and what each returned are Table 7.

Figure 2.
Acquisition context, and the input sets built from it. a, the nine pre-acquisition features, all fixed at or before the index acquisition, against the index-window block, which resolves only after it and never enters a confirmatory arm. b, which input block each arm reads, and the estimator family each arm uses. The sets are nested, so a difference between two adjacent columns is attributable to the block that was added.
Figure 2.
Acquisition context, and the input sets built from it. a, the nine pre-acquisition features, all fixed at or before the index acquisition, against the index-window block, which resolves only after it and never enters a confirmatory arm. b, which input block each arm reads, and the estimator family each arm uses. The sets are nested, so a difference between two adjacent columns is attributable to the block that was added.

Figure 3.
The nested input ladder at record level, one panel per reported horizon. Points are the AUROC of the seed-pooled score and bars are patient-clustered percentile bootstrap intervals over 10,000 resamples, on 3,626 patients at 24-hour ICU admission and 3,636 at both mortality horizons. The acquisition-context arm is orange and the waveform arm blue; marker shape is redundant with colour so the figure reads in grayscale. The dashed line is chance. Every value is a cell of Table 3.
Figure 3.
The nested input ladder at record level, one panel per reported horizon. Points are the AUROC of the seed-pooled score and bars are patient-clustered percentile bootstrap intervals over 10,000 resamples, on 3,626 patients at 24-hour ICU admission and 3,636 at both mortality horizons. The acquisition-context arm is orange and the waveform arm blue; marker shape is redundant with colour so the figure reads in grayscale. The dashed line is chance. Every value is a cell of Table 3.

Figure 4.
The acquisition-context advantage over age and sex against outcome horizon, as a paired difference in record-level AUROC with patient-clustered percentile bootstrap intervals on 3,636 patients. Orange circles are the four horizons the ladder was registered on; grey triangles are the two that generated the hypothesis and are shown for completeness only. The advantage peaks at seven days and declines at every longer horizon, and the interval on its rank correlation includes zero. Every value is a cell of Table 4.
Figure 4.
The acquisition-context advantage over age and sex against outcome horizon, as a paired difference in record-level AUROC with patient-clustered percentile bootstrap intervals on 3,636 patients. Orange circles are the four horizons the ladder was registered on; grey triangles are the two that generated the hypothesis and are shown for completeness only. The advantage peaks at seven days and declines at every longer horizon, and the interval on its rank correlation includes zero. Every value is a cell of Table 4.

Figure 5.
Reliability at 24-hour ICU admission under both declared binning schemes, for four of the eight arms; the other four are in Supplementary, Table S17. Points are bin means from the same reliability table the expected calibration errors are computed from. The dashed diagonal is perfect calibration. A curve below the diagonal is over-prediction.
Figure 5.
Reliability at 24-hour ICU admission under both declared binning schemes, for four of the eight arms; the other four are in Supplementary, Table S17. Points are bin means from the same reliability table the expected calibration errors are computed from. The dashed diagonal is perfect calibration. A curve below the diagonal is over-prediction.

Figure 6.
Net benefit against threshold probability at 24-hour ICU admission, with treat-all and treat-none as references and the registered threshold marked. The waveform arm follows treat-all up to roughly the registered threshold and falls below treat-none over part of the range above it. Curves are the full declared grid from the net-benefit table.
Figure 6.
Net benefit against threshold probability at 24-hour ICU admission, with treat-all and treat-none as references and the registered threshold marked. The waveform arm follows treat-all up to roughly the registered threshold and falls below treat-none over part of the range above it. Curves are the full declared grid from the net-benefit table.

Table 2.
The waveform reproduction, and the only crop-level numbers here. Unweighted macro AUROC over the 15 deterioration targets, at crop level, which is the unit the benchmark publishes. Gaps are against both published versions. The record-level macro beside it is the mean of the five per-seed macros and has no published counterpart.
Table 2.
The waveform reproduction, and the only crop-level numbers here. Unweighted macro AUROC over the 15 deterioration targets, at crop level, which is the unit the benchmark publishes. Gaps are against both published versions. The record-level macro beside it is the mean of the five per-seed macros and has no published counterpart.
| Arm | Unit | Published version | Local macro | Published [95% CI] | Gap | Inside |
|---|---|---|---|---|---|---|
| R6_waveform | crop | version of record | 0.8474 | 0.8565 [0.8410, 0.8707] | -0.0091 | yes |
| R6_waveform | crop | preprint | 0.8474 | 0.8279 [0.8047, 0.8511] | +0.0195 | yes |
| R7_waveform_demo_acq | crop | version of record | 0.8797 | 0.8565 [0.8410, 0.8707] | +0.0232 | no |
| R7_waveform_demo_acq | crop | preprint | 0.8797 | 0.8279 [0.8047, 0.8511] | +0.0518 | no |
| R6_waveform | record | - | 0.8545 | none published at this unit | - | - |
| R7_waveform_demo_acq | record | - | 0.8834 | none published at this unit | - | - |
Table 3.
The nested input ladder, record level. AUROC with a patient-clustered percentile bootstrap interval, 10,000 resamples, resampling unit subject_id. One row per ECG throughout: rows 1 to 5 have no crops, so the published crop-level protocol appears nowhere in this panel. Scores are averaged across the five seeds and one AUROC is taken on the pooled score, because a paired bootstrap needs one score vector per arm; per-seed spreads are in Supplementary, Table S7.
Table 3.
The nested input ladder, record level. AUROC with a patient-clustered percentile bootstrap interval, 10,000 resamples, resampling unit subject_id. One row per ECG throughout: rows 1 to 5 have no crops, so the published crop-level protocol appears nowhere in this panel. Scores are averaged across the five seeds and one AUROC is taken on the pooled score, because a paired bootstrap needs one score vector per arm; per-seed spreads are in Supplementary, Table S7.
| Row | Arm | ICU admission, 24h | Mortality, 28d | Mortality, 365d |
|---|---|---|---|---|
| 1 | R1_prevalence | 0.5000 [0.5000, 0.5000] | 0.5000 [0.5000, 0.5000] | 0.5000 [0.5000, 0.5000] |
| 2 | R2_demo | 0.6017 [0.5752, 0.6271] | 0.6963 [0.6608, 0.7307] | 0.7458 [0.7205, 0.7696] |
| 3 | R3_acqctx_pre | 0.7972 [0.7806, 0.8138] | 0.7587 [0.7264, 0.7903] | 0.7241 [0.7029, 0.7441] |
| 3b | R3b_acqctx_window | 0.8010 [0.7845, 0.8174] | 0.7637 [0.7303, 0.7958] | 0.7272 [0.7057, 0.7474] |
| 4 | R4_demo_acq | 0.8094 [0.7928, 0.8255] | 0.8102 [0.7818, 0.8371] | 0.8033 [0.7832, 0.8221] |
| 5 | R5_tabular | 0.9164 [0.9046, 0.9278] | 0.9102 [0.8884, 0.9294] | 0.8533 [0.8371, 0.8689] |
| 6 | R6_waveform | 0.8173 [0.7995, 0.8342] | 0.8473 [0.8222, 0.8714] | 0.8294 [0.8109, 0.8474] |
| 7 | R7_waveform_demo_acq | 0.8571 [0.8424, 0.8713] | 0.8723 [0.8485, 0.8947] | 0.8533 [0.8365, 0.8693] |
Table 4.
The horizon ladder: a separate family, per-horizon differences. R3_acqctx_pre minus R2_demo at each mortality horizon. The primary test covers only the four horizons no arm had been scored on. The two horizons that generated the hypothesis are shown, carry no ladder-adjusted p, and never count as confirmation.
Table 4.
The horizon ladder: a separate family, per-horizon differences. R3_acqctx_pre minus R2_demo at each mortality horizon. The primary test covers only the four horizons no arm had been scored on. The two horizons that generated the hypothesis are shown, carry no ladder-adjusted p, and never count as confirmation.
| Label | Horizon (d) | Difference [95% CI] | Raw p | Holm p | Role |
|---|---|---|---|---|---|
| Mortality, 1d | 1 | +0.0946 [-0.0360, +0.2168] | 0.1478 | 0.708 | primary |
| Mortality, 7d | 7 | +0.1224 [+0.0436, +0.2004] | 0.0006 | 0.0036 | primary |
| Mortality, 28d | 28 | +0.0624 [+0.0165, +0.1082] | 0.0108 | not corrected in this family | generating |
| Mortality, 90d | 90 | +0.0161 [-0.0225, +0.0539] | 0.4092 | 1 | primary |
| Mortality, 180d | 180 | +0.0030 [-0.0306, +0.0367] | 0.8656 | 1 | primary |
| Mortality, 365d | 365 | -0.0216 [-0.0523, +0.0098] | 0.177 | not corrected in this family | generating |
Table 5.
Waveform gain retained: the declared secondary quantity. (R6 - R2) within stratum over (R6 - R2) on the same rows without the pair restriction. The declared formula does not say which R2 the numerator takes, so both are given; the first is the reading quoted in the abstract and the conclusion.
Table 5.
Waveform gain retained: the declared secondary quantity. (R6 - R2) within stratum over (R6 - R2) on the same rows without the pair restriction. The declared formula does not say which R2 the numerator takes, so both are given; the first is the reading quoted in the abstract and the conclusion.
| Label | Retained, quoted reading [95% CI] | Meets target | Retained, unstratified R2 [95% CI] | Meets target | Declared target |
|---|---|---|---|---|---|
| ICU admission, 24h | 0.7846 [0.6308, 0.9259] | no | 0.6765 [0.5491, 0.7830] | no | at most 0.50 |
| Mortality, 28d | 0.8643 [0.5584, 1.1720] | no | 0.5518 [0.1822, 0.8262] | no | at most 0.50 |
| Mortality, 365d | 0.9313 [0.6631, 1.1583] | no | 0.6148 [0.3014, 0.8244] | no | at most 0.50 |
Table 6.
Net benefit at the pre-declared threshold. Threshold 0.10, fixed from the clinical framing and recorded before any curve was computed, and quoted at 24-hour ICU admission alone because it is the only reported label with an action available at emergency-department disposition. Treating everyone scores 0.0288 here and treating no one scores exactly zero; the prevalence is 0.1260, which no rule can exceed. The comparison against treat-all is a paired clustered bootstrap on the difference, since treat-all also varies with the resampled prevalence.
Table 6.
Net benefit at the pre-declared threshold. Threshold 0.10, fixed from the clinical framing and recorded before any curve was computed, and quoted at 24-hour ICU admission alone because it is the only reported label with an action available at emergency-department disposition. Treating everyone scores 0.0288 here and treating no one scores exactly zero; the prevalence is 0.1260, which no rule can exceed. The comparison against treat-all is a paired clustered bootstrap on the difference, since treat-all also varies with the resampled prevalence.
| Arm | Net benefit [95% CI] | vs treat-all [95% CI] | Beats treat-all | Fraction flagged | Mean predicted |
|---|---|---|---|---|---|
| R5_tabular | 0.0897 [0.0802, 0.0993] | +0.0609 [+0.0560, +0.0654] | yes | 0.2397 | 0.1206 |
| R4_demo_acq | 0.0671 [0.0580, 0.0766] | +0.0383 [+0.0334, +0.0430] | yes | 0.3902 | 0.1219 |
| R3b_acqctx_window | 0.0662 [0.0570, 0.0759] | +0.0374 [+0.0327, +0.0420] | yes | 0.4122 | 0.1217 |
| R3_acqctx_pre | 0.0653 [0.0564, 0.0748] | +0.0365 [+0.0317, +0.0411] | yes | 0.4077 | 0.1226 |
| R7_waveform_demo_acq | 0.0367 [0.0254, 0.0482] | +0.0079 [+0.0069, +0.0088] | yes | 0.9277 | 0.2426 |
| R2_demo | 0.0351 [0.0243, 0.0461] | +0.0062 [+0.0022, +0.0101] | yes | 0.7987 | 0.1218 |
| R6_waveform | 0.0334 [0.0220, 0.0449] | +0.0045 [+0.0038, +0.0053] | yes | 0.9575 | 0.2502 |
| R1_prevalence | 0.0288 [0.0174, 0.0403] | +0.0000 [-0.0000, +0.0000] | no | 1.0000 | 0.1217 |
Table 7.
Every pre-declared quantitative target, and what it measured. Each target was fixed in a committed comparison file before the run that tests it existed.
Table 7.
Every pre-declared quantitative target, and what it measured. Each target was fixed in a committed comparison file before the run that tests it existed.
| Quantity | Endpoint | Pre-declared | Measured [95% CI] | Outcome |
|---|---|---|---|---|
| G1: R3_acqctx_pre beats R2_demo | Mortality, 365d | positive, beyond the 0.0043 seed and noise spread | -0.0216 [-0.0523, +0.0098] | FAILED |
| Recovery ratio, R3_acqctx_pre against R6_waveform | Mortality, 365d | at least 0.70 | 0.6803 [0.6149, 0.7476] | FAILED |
| Waveform gain retained with acquisition context held fixed | Mortality, 365d | at most 0.50 | 0.9313 [0.6631, 1.1583] | FAILED |
| Horizon-ladder trend, four never-scored horizons | mortality 1, 7, 90, 180 d | negative, interval excluding zero | -0.8000 [-1.0000, +0.2000] | NOT SUPPORTED |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.