Preprint
Data Descriptor

This version is not peer-reviewed.

An Indoor UWB–IMU Dataset with Static and Robot-Based Dynamic Ranging Measurements and Reference Positions

Submitted:

21 November 2026

Posted:

24 November 2026

You are already at the latest version

Abstract
This Data Descriptor presents an indoor dataset of ultra-wideband (UWB) ranging and inertial measurement unit (IMU) observations from a furnished laboratory. Three tags ranged against five anchors, all with DW1000 transceivers, using broadcast single-sided two-way ranging (SS-TWR) on UWB channel 5 at 110 kb/s; two tags also recorded acceleration and angular rate. Version 1.0 contains 18 static recordings at 54 positions and 19 dynamic recordings. Static records contain 175,023 received ranges at reference distances of 1.2–11.6 m, each with tag-side and anchor-side radio diagnostics, raw timestamps, separated clock-correction terms, laser-surveyed reference positions and an operator-assigned line-of-sight (LOS) or non-line-of-sight (NLOS) label. The median signed error (reference minus estimate) was 0.34 m for LOS and 0.24 m for NLOS links, and within-link spread increased with the anchor reply interval. Dynamic records contain 24,598 received ranges and combine robot-mounted UWB/IMU, encoder telemetry, hardware pulse synchronization and two-mast endpoint surveys. Raw streams, normalized tables, quality-control reports and derived references are provided separately. Validation examined record integrity, stream continuity, IMU stability, survey consistency, temporal association and ranging error. Dynamic intermediate positions are model-dependent references, not independently measured ground truth. The dataset supports ranging-error mitigation and UWB-IMU localization research.
Keywords: 
;  ;  ;  ;  ;  ;  ;  ;  

1. Summary

UWB ranging supports indoor localization [1], but NLOS propagation and multipath can distort measured distances [2]. Identifying and mitigating these errors from received waveforms or radio diagnostics has been studied extensively, increasingly with learning-based methods [3,4,5,6]. On low-cost DW1000 transceivers, SS-TWR also depends on how accurately the relative clock offset between the two devices is compensated over the responder’s reply interval [7]. IMUs provide complementary motion observations [8]. Reproducible evaluation of range correction and UWB–IMU localization requires documented measurements, geometry, timing, reference quality and reusable data products [9].
Table 1 provides a representative, rather than exhaustive, comparison of datasets for channel analysis and robot localization; further public collections support the identification of LOS and NLOS conditions and range-error correction [6,10]. Within Table 1, this work is the only dataset that pairs SS-TWR with both tag-side and anchor-side radio diagnostics. It also stores the raw DW1000 timestamps and the uncorrected and clock-correction range terms of every response, so that ranges can be re-derived and clock-induced errors modeled, and it combines static and robot-carried measurements from one furnished laboratory.
Version 1.0 provides:
  • 18 static recordings at 54 laser-surveyed tag positions, with 175,023 received ranges on 270 configured tag–anchor links (205 LOS and 65 NLOS);
  • per-response tag-side and anchor-side diagnostics, raw 40-bit DW1000 timestamps, and separately stored uncorrected and clock-correction range terms;
  • acceleration and angular-rate samples from two tags with different IMUs (MPU9250 and BMX160), timestamped on the same tag clock as their UWB cycles;
  • 19 robot-carried dynamic recordings with encoder telemetry, hardware pulse synchronization and two-mast endpoint surveys;
  • calibration metadata, provenance, QC reports, field dictionaries and a SHA-256 file inventory.
The dataset supports range-correction and localization research without benchmarking a particular estimator.

2. Data Description

2.1. Dataset Organization

The dataset separates static sessions, dynamic sessions and derived dynamic products (Figure 1). Static sessions record fixed placements and link conditions; dynamic sessions record one motion plan. Acquisition directories retain raw JSON Lines streams, CSV tables and JSON metadata. Derived products retain source session identifiers under dynamic-derived/; dynamic_run_manifest.csv indexes these products and provides surveyedDistanceClass. Original acquisition names remain unchanged.
Static QC outputs under qc/ comprise dataset-summary.json (policy, counts, dataset checks and readiness), checks.csv (recording-level severity, status and metrics), session-decisions.csv (decisions and error/warning codes), and sessions/<session-id>.json (detailed checks, stream statistics and hashes). Dynamic checks are stored in each recording’s quality_report.json (Section 2.3).

2.2. Static Data Records

All tags contribute static UWB records; T2 and T3 also provide IMU samples (Table 2). A placement links a tag to a surveyed point within a session and contains repeated observations. In version 1.0, the 54 point identifiers denote 54 distinct surveyed positions.
The static cycle key is (sessionId, tagId, bootId, cycleSeqNum). Ranges add anchorId; IMU samples replace cycleSeqNum with sampleSeqNum. Original and corrected IMU tables share this key. Ranges retain surveyed antenna coordinates and their Euclidean separation, trueRange (Equation 13). The correction target is rangeError = trueRange - estimatedRange: positive denotes underestimation, negative denotes overestimation, and zero denotes agreement. It retains survey and room-model uncertainty (Section 3.2).
Original IMU samples are recorded in their firmware-reported calibrated form, with enabled correction flags, gravity retained in sensor axes and no supplied laboratory-frame transformation (Section 3.1.1). The optional stationary-corrected product (Section 3.4) adds residual-gyroscope-corrected columns for the same samples, not additional observations.

2.3. Dynamic Data Records

Dynamic records combine T3 UWB/IMU, Mega telemetry, synchronization pairs and two-mast endpoint surveys (Table 3). The surveys provide horizontal position and heading; the recorded fixed antenna height completes T3 XYZ. Raw encoder telemetry and integrated odometry are distinct. Original ranges.csv contains neither trueRange nor rangeError; values computed from reconstructed positions are model-dependent products.
syncValid indicates that T3 generated a valid pulse; it does not indicate that the Mega recorded a matching edge. Within a session, syncSeq in cycles.csv joins tagSeq in sync_pairs.csv only with matching tag boot, Mega boot and synchronization run. Reference tables use cycleSeqNum or sampleSeqNum but omit device and boot identifiers; sequence-only joins require a verified single T3 boot and paired clock domain. The numeric robot.csv.session is controller-local, whereas session in the derived cycle table identifies the dataset session. Files without an explicit dataset-session identifier inherit the identifier of their enclosing session directory.
referenceValid=True denotes bounded temporal association, not positional accuracy; rows outside valid pulse-pair and trajectory intervals are invalid and retain blank coordinates (Section 3.1.2 and Section 3.1.3).
Endpoint-constrained products project encoder progress onto the surveyed chord (Equation 17). Unlike the odometry tables, every derived cycle has a valid paired edge within trajectory support, placement=interpolated and edgeToPathUs=0; signed encoder progress is retained without boundary clamping, clipping or monotonicization. Derived headingDeg is the chord bearing, not measured yaw, and no endpoint-constrained IMU table is supplied. Because only endpoints are surveyed, neither dynamic reference is independently measured continuous ground truth. Correction records and reprocessing-backups/, where present, preserve earlier file versions as audit history.

2.4. Identifiers, Timestamps, Units, and Missing Values

Column names and identifiers are case-sensitive, and device addresses are stored as decimal integers (e.g., T3 is 49, i.e., 0x0031). Sequence counters require session, device and boot context; dynamic cycle/range joins use tagAddress instead of tagId. Table 4 distinguishes clock domains.
Mask bits 0–4 identify A1–A5. No response means no range row; a received but unavailable range retains its row with rangeAvailable=False; a finite negative range remains available with negativeRange=True. Empty CSV scalars/JSON null are not zero. CSV True/False and JSON true/false require Boolean parsing; no automatic imputation is performed.
Ranges/positions use m , acceleration m   s − 2 , angular rate ∘   s − 1 , motor speed RPM , current m A , steering pulses μ s , and encoder position counts. Heading units are indicated by the specific field names. Poll diagnostics originate at the anchor receiver and response diagnostics at the tag receiver. RXPW/FPP are estimates in dBm ( − 999 is an invalid-power sentinel); other signal diagnostics and CarrierIntegrator retain register encodings, while ClockOffsetPPM uses ppm . Static link labels are LOS, NLOS or UNKNOWN; no link in version 1.0 is labeled UNKNOWN. The session-level MIXED label marks static sessions with differently classified links and dynamic runs whose propagation conditions may change along the path; it does not classify individual cycles. The phase field records the logger lifecycle state at receipt, not a measurement-time motion classification.

2.5. Data Dictionary and Machine Readability

The data-reuse guide explains reference selection and association limits; examples/load_dataset_records.py demonstrates parsing and session/boot-scoped joins. The three CSV dictionaries under data-dictionary/ catalog observed columns, nested paths, core units and missing-value conventions: static-columns.csv, dynamic-columns.csv and metadata-fields.csv. The last combines metadata, raw-stream and auxiliary table fields, distinguished by fieldCategory; undocumented meanings remain explicitly unresolved. Geometry and calibration metadata are embedded in session records rather than supplied as separate top-level folders. The dataset version identifies a collection release, whereas schema versions identify record formats.

2.6. Dataset Composition and Coverage

Table 5 includes non-motion records; pulse validity, edge pairing and trajectory availability are distinct measures.
The release manifest (dataset-v1.0-manifest.csv) records per-session inclusion status, whereas dynamic-derived/dynamic_run_manifest.csv indexes dynamic recordings and their derived products. Its 3524 derived cycle positions use the normalized phase=motion selection, whereas the 3530 motion-QC cycles use paired measurement-edge times; the difference reflects boundary definitions, not missing associations.
Figure 2 counts configured links from session metadata, including zero-response links. Eight dynamic runs are short, eight medium and three long, with endpoint chords of 2.96 m to 8.09 m ; the surveyed classes (Section 3.4) match the acquisition names. Coverage across classes and speeds is unbalanced, and each long class/speed combination contains one recording. Commanded motor RPM is a rotational setpoint, not measured translational velocity. Drive durations span 8.8 s to 70.5 s , excluding zero-speed positioning.

3. Methods

3.1. Experimental System and Data Acquisition Architecture

The platform comprised three UWB tags (T1–T3), five fixed anchors (A1–A5), a robot and an acquisition computer (Figure 3). A Python logger archived ranging data and T2/T3 IMU samples published over Wi-Fi through Mosquitto using MQTT [17]. During dynamic acquisition, an Arduino Mega controlled the EPOS drive and steering servo, returned motor and encoder telemetry through USB serial, and captured T3 synchronization pulses.

3.1.1. System Configuration, Hardware Mounting, and Calibration

Table 6 specifies the deployed configuration, following the WisBlock and DW1000 documentation [18,19]. Static tags used freestanding aluminum-extrusion masts with supplies near the base; anchors used open-front wall brackets (Figure 4). Dynamic T3 used a front mast, with a second fixed mast providing a heading baseline.
The robot frame used axes x b , y b and z b (Figure 4), directed forward, left and upward. Subscript s identifies each IMU’s sensor frame ( X s , Y s , Z s ) ; laboratory axes ( X , Y , Z ) are defined in Section 3.2. The geometric survey (18 November 2026) used the floor projection of the rear-axle midpoint as the planar origin; the resulting parameters (Table 7) were common to all 19 released plans. The unmeasured BMX160-to-antenna displacement precluded IMU lever-arm correction. A lifted-wheel test established encoder direction; four intended-straight 500 RPM runs with laser-surveyed endpoints fitted the encoder scale:
k e = arg min k ∑ r d r survey − k | Δ n r | 2 ,
where d r survey is the surveyed endpoint distance of run r and Δ n r its quadrature-count change, with fitted scale k e = 6.797 524 × 10−6 m count−1. All released runs used the 1200 μs steering command, which the archived provisional lookup mapped to 0.095 ∘ ; this did not establish a measured zero wheel angle or a validated turning model.
Antenna-delay calibration used isolated LOS tag–anchor pairs at measured separation. With crystal trims fixed, device delays were varied individually and ranked by absolute mean bias over 200 valid DS-TWR observations. An additional 400-observation check required mean bias within 0.02 m ; Table 6 lists the deployed delays and the common trim of 10. This DS-TWR acceptance does not establish SS-TWR accuracy, which Section 3.5.3 characterizes.
IMU calibration used six static ± X s , ± Y s , ± Z s orientations and an axis-wise bias/scale model [24]. Verification used a second six-orientation sequence and a separate 30 s stationary gyroscope record. Firmware corrections were
a c = ( a r − b a ) ⊘ s a , ω c = ω r − b ω ,
where ⊘ denotes element-wise division. Table 8 reports coefficients in the source file matching the static sessions’ archived hash. The logger’s intended-coefficient metadata differed from that source, and neither record verifies the coefficients in the flashed binary; dynamic sessions retained calibration flags but no coefficient snapshot. Gyroscope scale, cross-axis alignment, magnetometer response and temperature dependence were not calibrated. Static T2 axes were + X s down, + Y s left, + Z s forward; T3 axes were + X s left, + Y s up, + Z s forward. Absolute mast heading and small mounting misalignments were unmeasured. MPU9250 registers were SMPLRT_DIV=9, CONFIG=3, GYRO_CONFIG=8, ACCEL_CONFIG=8 and ACCEL_CONFIG2=3; BMX160 accelerometer and gyroscope configuration/range codes were 9/5 and 9/2.

3.1.2. Broadcast SS-TWR Protocol and Network Coordination

Figure 5 shows scheduled UWB exchanges alongside independent tag-internal IMU sampling and robot acquisition.
The application-specific frame contained 42 software-provided bytes plus a driver-appended two-byte FCS, forming a 44-byte MAC frame, excluding the PHY preamble, delimiter and header [19]. Multi-byte integers were little-endian; polls used the 10-byte header and zero-filled the remainder (Table 9). Addresses followed a T ( i ) = 16 i + 1 and a A ( j ) = 16 j + 2 (Table 6). Polls were broadcast; responses addressed the initiating tag, with the responding anchor as source.
Each UTC-aligned tag slot admitted one broadcast poll (Table 6), giving a nominal per-tag rate of 5.56 Hz . Slot admission required a valid network-time estimate no older than 10 min . Opportunities more than 3 m s late, or awaiting release of a previous cycle, were skipped and counted. For poll transmit time t 1 , anchor A j received at t 2 , j and scheduled its reply using
δ j = 250   μ s + j 6000   μ s , j ∈ { 1 , … , 5 } ,
relative to the DW1000 time when that response was configured, not necessarily to t 2 , j . The reply carried t 2 , j , scheduled transmit time t 3 , j and anchor diagnostics. The tag recorded arrival time t 4 , j and tag-side diagnostics while remaining in receive mode. One extra 6 m s response slot defined the receive budget B = 250   μ s + ( 5 + 1 ) 6000   μ s = 36.25   m s , a configured margin rather than a frame-airtime calculation; the watchdog rounded B up to 37 m s after poll-transmission completion, and a 5 m s end guard bounded each tag slot.
Within the receive window, response checks covered length, PAN, type, destination and source. The firmware accepted each anchor at most once, retaining a five-bit response mask and request sequence. Cycles closed after all responses or at the deadline, including poll failures and partial- or zero-response cycles, without retransmission or zero-range imputation. Status, masks, error counters, scheduling jitter and missed-slot counts supported data-loss interpretation.
A1–A5 response opportunities span 24 m s ; a tag moving at speed v travels v 0.024 s during that interval. The cycle reference assigns one paired cycle-start position to all range rows, not separate response-time positions. Per-range tagPollTxTicks and tagResponseRxTicks record this timing. Pulse-to-radio-transmission latency was not independently measured.
UTC time controlled slot admission and was not used in range computation. Tag timestamps t 1 , t 4 , j and anchor timestamps t 2 , j , t 3 , j belonged to different DW1000 clocks; anchors were not mutually synchronized. Node antenna delays adjusted timestamp references toward the antenna [25], and the receive-timestamp library applied an RXPW-dependent bias correction. For 40-bit counters, let Δ 40 ( a , b ) = ( a − b ) mod 2 40 :
R j = Δ 40 ( t 4 , j , t 1 ) , D j = Δ 40 ( t 3 , j , t 2 , j ) .
The signed carrier-integrator value c j gave the relative offset p j for channel 5 at 110 kbit s−1 using the carrier-recovery integrator conversion in the DW1000 user manual [26]:
p j = c j − 10 6 ( 998.4 × 10 6 ) 2 ( 8192 ) ( 131072 ) ( 6489.6 × 10 6 ) ppm
Here 998.4 × 106  Hz is the receiver sampling frequency, 6489.6 × 106  Hz the channel-5 carrier frequency, 8192 the sample count at 110 kbit s−1, and 131072 = 2 17 the fractional-register scaling. Both c j and p j were retained. SS-TWR reply-delay subtraction [7] gave the clock-corrected time of flight
τ ^ j = R j − D j 1 − p j × 10 − 6 2 .
With the DW1000 range conversion factor k = 4.6917639786159 × 10 − 3 m   tick −1, d ^ j = k τ ^ j , decomposed as
d j ( 0 ) = k 2 ( R j − D j ) , d j ( clk ) = k 2 D j p j × 10 − 6 , d ^ j = d j ( 0 ) + d j ( clk ) .
The uncorrected and clock terms are stored in rangeWithoutClockCorrection and clockCorrectionMeters; their sum is estimatedRange. Signal diagnostics were retained separately, not inserted into this equation.
Because each reply was scheduled relative to response configuration rather than to t 2 , j , the recorded reply intervals D j exceeded δ j by approximately 4.70 m s . Their medians were 10.95 ms, 16.95 ms, 22.95 ms, 28.95 ms and 34.95 ms for A1–A5. From Equation (6), an error ε in the relative clock-offset estimate changes d ^ j by c D j ε / 2 , where c is the speed of light; across A1–A5 this is 1.6 cm to 5.2 cm per 0.01 ppm. Section 3.5.3 reports the resulting ranging statistics.

3.1.3. Robot–Tag Synchronization

T3 WB_IO1/GPIO14 (nominal 3.3 V ) connected through a 1 k Ω series resistor to Mega interrupt input D2, with a 10 k Ω pull-down and common ground (Figure 6). D2 used INPUT, without its internal pull-up; no 5 V connection was made to the tag output.
Immediately before each admitted T3 poll attempt, GPIO14 was asserted and, if its one-shot timer started, returned low after nominally 100 μ s . An armed D2 rising-edge interrupt recorded Mega micros() and incremented its counter, marking software cycle start rather than exact radio transmission. Validity required successful timer start and a software timestamp bracket of at most 20 μ s .
Before motion, at least five consecutive observations established
Δ q = q T − q M , q M = q T − Δ q ,
where q T , q M are independent pulse counters. The offset Δ q remained fixed within each boot/run context, predicting subsequent Mega counters from T3 counters. Initial pairing required host-arrival separation at most 60 m s and consecutive pulse-interval agreement within 2 m s ; paired Mega edges then supplied cycle times. Reboots, duplicate counters, ambiguous pairs, dropped edges or nonconsecutive motion pulses invalidated synchronization; missing edges were never synthesized.
Between consecutive valid pairs ( u k T , u k M ) and ( u k + 1 T , u k + 1 M ) , IMU times were mapped without extrapolation by
u ^ M ( u ) = u k M + u − u k T u k + 1 T − u k T u k + 1 M − u k M , u k T ≤ u ≤ u k + 1 T .
UWB cycles used directly paired edges rather than this interpolated map.

3.2. Experimental Environment and Reference Coordinate System

The six-wall laboratory at the Universidade de Trás-os-Montes e Alto Douro, Vila Real, Portugal, is shown in Figure 7. The floor-level W1–W2 intersection defined the origin; + X followed W1 toward W6, + Y pointed inward and + Z upward ( z = 0 on the level floor). Static and anchor positions refer to the UWB antenna reference point, not the mast, board or robot body. Dynamic mast surveys were transformed to the T3 antenna point using the mounting offset; all coordinates are in meters.
In the room model, measured lower-wall narrowing was divided equally between sides, W4 was modeled parallel to W6, and the W5 boundary was fitted to three measured Y-extents. Table 10 and Table 11 list counter-clockwise vertices and fixed anchor coordinates. Static metadata retained the boundary model and derived geometry; dynamic metadata retained the anchor map, both endpoint surveys and coordinate fits.
At least two nonparallel walls supplied perpendicular distances m k from the antenna reference point for static surveys, or each marked mast center for dynamic surveys. Horizontal coordinates minimized
p ^ x y = arg min p ∈ B ∑ k ∈ W d p , ℓ k − m k 2 ,
within the vertices’ bounding box B = [ x min , x max ] × [ y min , y max ] . Here W denotes measured walls and d ( p , ℓ k ) the unsigned distance to each infinite reference line. Initialization used the six-vertex mean; acceptance required polygon membership. Using named walls together with the polygon-membership constraint rejected wrong-side solutions, but no multi-start search or formal uniqueness proof was performed. Static antenna heights used vertical measurements at the same local ceiling position:
z = H f c − H a c .
Dynamic surveys instead used the fixed mounting height of 1.204 m ; ceiling distances were not re-entered at each endpoint. The Bosch GLM 80 Professional specifies 0.1 m m resolution and typical accuracy ±1.5 m m (±2.5 m m in unfavorable conditions) [27]. Survey consistency, rather than absolute coordinate accuracy, was measured by
RMSE wall = 1 | W | ∑ k ∈ W d p ^ x y , ℓ k − m k 2 .
No combined absolute-position uncertainty was quantified from the instrument specification, fit residual, room-model assumptions, antenna reference placement and possible solution ambiguity. Static geometric reference ranges were
d i j ref = ( x T i − x A j ) 2 + ( y T i − y A j ) 2 + ( z T i − z A j ) 2 .
The furnished laboratory included walls, metal furniture and electronic-equipment boxes as potential obstructions.

3.3. Measurement Acquisition Protocol

Static and dynamic procedures (Figure 8) required geometry, device and stream preflight checks. Changed placement, orientation, propagation configuration or motion plans required a new session.

3.3.1. Static Acquisition

Tags occupied surveyed antenna positions (Figure 7); orientation and notes were retained where available, otherwise marked not recorded. The operator assigned LOS to visibly unobstructed direct paths, NLOS to blocked paths and UNKNOWN where classification was indefensible. These physical setup assessments were neither signal-derived nor independently adjudicated.
Preflight required UWB from every tag and calibrated IMU from T2 and T3 within 60 s , with observations at most 2 s old. After placement confirmation and 10 s settling, freshness was rechecked. Tags stayed stationary throughout 120 s acquisition and a 1 s late-packet drain before MQTT closure. Per-tag capture windows used monotonic acquisition time, anchored once to a recent UWB time estimate and host acquisition-start clock; arrival time served only freshness and transport checks. A required stream that remained absent for more than 5 s caused capture to terminate.

3.3.2. Dynamic Acquisition

Each machine-readable plan specified two-mast survey settings, limits, steering, motor RPM, segment durations and notes. Observed surveys were archived separately. With the robot stationary, front and rear mast coordinates f and r were fitted independently from wall distances. Heading and the T3 antenna coordinate were then derived as
ψ ^ = atan2 ( f y − r y , f x − r x ) − α , p T 3 , x y = f + R ( ψ ^ ) ℓ f T 3 ,
where R is the planar rotation matrix, the configured baseline angle was α = 0 , and the front-mast-to-antenna offset was ℓ f T 3 = ( 0.0115 , − 0.0250 ) m }. The fitted mast separation had to agree with 0.4475 m within 0.010 m . This estimated heading from surveyed positions; the laser did not directly measure an angle. The first segment held zero RPM and 1200 μ s steering for 6 s . Subsequent motor RPM varied by plan (Figure 2c), as did segment duration. Figure 9 shows the surveyed endpoints and straight-path references.
MQTT/USB preflight required firmware status, encoder, UWB and calibrated IMU within 20 s , rejecting observations over 2 s old. Startup EPOS faults were cleared only while stationary, followed by healthy feedback and token-matched STOP verification. After displaying the plan and receiving explicit RUN, the logger applied limits and allowed 12 s for pulse pairing (Section 3.1.3).
A 2 s pre-roll preceded zero-speed arming and ordered segment execution; drive commands were renewed every 100 m s . T3 UWB and IMU data arrived through MQTT, while robot telemetry, edges, commands and acknowledgments arrived through USB. Faults, resets, stale telemetry, transport failure or synchronization discontinuity triggered an attempted safe stop; partial sessions were retained.
After the last segment, zero-speed STOP verification preceded 2 s post-roll, synchronization/MQTT closure, a second STOP verification and serial closure. The operator then repeated both mast surveys to obtain the final T3 position and heading using Equation 14; these endpoint poses were independent of odometry.

3.4. Data Logging, Processing, and Curation

Dequeued MQTT envelopes and robot serial audit records were preserved alongside normalized tables and session provenance (Section 2). Raw audit streams remained unchanged; operator-confirmed survey corrections retained originals and correction logs. No magnitude-based range filtering or imputation was applied. Sequence, missed-slot, firmware drop, radio/IMU-error and logger-queue summaries exposed losses but could not perfectly attribute MQTT QoS 0 loss. Raw audits contain logger-received messages, not proof of every firmware-generated record.
Static residual gyroscope correction used centered 10 s windows within continuous tag/boot/sensor segments, subtracting offsets only with at least 100 samples and 1 s support. Gaps over 0.5 s split segments. This offline correction assumed continuous stationarity and used past and future samples. Separate corrected columns preserved originals without reapplying firmware calibration; dynamic recordings were not corrected.
Dynamic association used acquisition time and Equation 9. Mega’s 32-bit micros() was unwrapped per boot, rejecting ambiguous half-wrap intervals. The rear-axle bicycle model [28] integrated consecutive encoder counts as
Δ s i = η k e Δ n i , Δ ψ i = Δ s i L tan δ i ,
with encoder direction η , scale k e , signed wrap-safe 32-bit difference Δ n i , wheelbase L and pulse-derived steering δ i . The midpoint-heading update was
r i = r i − 1 + Δ s i cos ( ψ i − 1 + Δ ψ i / 2 ) sin ( ψ i − 1 + Δ ψ i / 2 ) , ψ i = ψ i − 1 + Δ ψ i .
The body-to-T3 offset (Table 7), rotated by ψ i , was added to r i . Because δ i came from the provisional steering lookup (Section 3.1.1), curved-motion accuracy was not established. Failed interpolation at paired cycle starts or mapped IMU times retained invalid association flags.
For intended straight runs, post-processing generated
p ec ( t ) = p 0 + s ( t ) − s 0 s 1 − s 0 p 1 − p 0 , s 1 ≠ s 0 ,
where p 0 , p 1 are surveyed endpoints and s 0 , s 1 the cumulative encoder distances at the first/last trajectory samples. This preserves relative encoder progress while enforcing the straight chord. The canonical heading, the bearing of the imposed chord, was
ψ ec = atan2 ( y 1 − y 0 , x 1 − x 0 ) ,
counter-clockwise from laboratory + X , with 0 ≤ ψ ec < 360 ∘ ; the two-mast endpoint headings remained separate survey measurements. Endpoint-chord classes were short ( d < 3.5 m), medium ( 3.5   m ≤ d < 5.75   m ) and long ( d ≥ 5.75   m ); original identifiers/names were unchanged and the derived manifest retained canonical classes.
Session metadata retained configuration, geometry, source hashes, status, counts and stream summaries. Interrupted, aborted or incomplete acquisitions retained their status in the source collection; the release contains the 37 completed sessions, linked to derived products and QC reports by the frozen manifest, field dictionaries and SHA-256 inventory.

3.5. Technical Validation

3.5.1. Record Integrity and Stationary Stability

Validation covered the 18 static and 19 dynamic recordings (Section 2.6); Table 12 summarizes the criteria. SHA-256 checks matched the 90 static acquisition files (session.json, raw.jsonl, cycles.csv, ranges.csv and imu.csv per session) and all 718 files of the release inventory, which excludes only its own hash; the read-only checks left all 719 release files unchanged. An exact offline replay by the authors reproduced 95/95 dynamic robot/reference CSV files byte-for-byte; the replay tool is not part of the release. Boundary and telemetry-gap reprocessing used recorded encoder snapshots from robot-status messages, without synthesizing observations or relaxing the timing limits.
Session-scoped joins found no duplicate cycle, range or IMU keys, orphan ranges, or inconsistent reference-validity fields. Static geometric ranges and signed correction targets agreed with saved coordinates and range arithmetic within 1 × 10−9  m : numerical consistency, not metrological accuracy. Raw-to-normalized count and response-mask checks passed for all static sessions. For dynamic checks, L e denotes unadjusted encoder distance and L c the surveyed planar endpoint chord.
All 36 static tag–session IMU checks passed: mean acceleration magnitude 8 ms−2 to 12 ms−2, acceleration-magnitude standard deviation below 0.25 ms−2, and each gyroscope-axis standard deviation below 1 ° s−1. Observed standard-deviation maxima were 0.018 64 ms−2 and 0.094 ° s−1, respectively. Session mean acceleration magnitudes were 9.82 ms−2 to 9.86 ms−2 for the MPU9250 and 9.74 ms−2 to 9.89ms−2 for the BMX160, all within 0.09 ms−2 of standard gravity. These establish stationary stability, not absolute bias, attitude or integrated-position accuracy.

3.5.2. Survey Consistency

Only the seven static positions surveyed against at least three walls (Figure 10a) provide a redundant consistency test; the other 47 two-wall fits have near-zero residuals by construction. Initial screening flagged a P02 wall-fit RMSE of 83.43 m m ; an operator-confirmed wall-distance transcription correction reduced it to 18.88 m m , below the 50 m m gate, with the original values and correction audit archived and raw sensor values unchanged.
All 76 front/rear mast fits of the 38 dynamic endpoint surveys also used two walls; the independently specified mast spacing provided their consistency check, with a maximum separation discrepancy of 9.07 m m . Wall-fit RMSE measures room-model agreement (Equation 12), not absolute antenna-position error.

3.5.3. Static Ranging Measurements

Static ranges were compared with the surveyed reference ranges (Equation (13)), which inherit the survey limitations of Section 3.2, to characterize the archived measurements rather than to benchmark a correction method (Table 13, Figure 11). Of 175,023 received responses, 175,019 carried a computed range, at reference distances of 1.15 m to 11.56 m . LOS estimates were shorter than the reference in 89.2% of cases: the LOS error had a median of 0.341 m (IQR 0.164 m to 0.535 m ), a mean of 0.351 m and a standard deviation of 0.391 m . NLOS errors had a median of 0.241 m (IQR 0.024 m to 0.451 m ), a mean of 0.222 m and a standard deviation of 0.493 m . Relative to LOS links, the NLOS distribution was therefore shifted toward longer estimates and was wider (Figure 11a). Seven errors exceeded 3 m in magnitude (maximum 48.38 m ); they were retained.
The LOS median error differed by anchor, from 0.213 m (A4) to 0.494 m (A5), but showed no systematic trend with reference range: the medians of 1 m distance bins lay between 0.19 m and 0.42 m (Figure 11b,c). This distance-independent, anchor-dependent offset characterizes the deployed broadcast SS-TWR configuration, whose antenna delays had been accepted under DS-TWR (Section 3.1.1); its cause was not isolated in this study. Within each LOS link, the robust spread of the estimated range, 1.4826 times its MAD, increased monotonically with the reply interval, from 8.4 c m for A1 to 32.6 c m for A5 (Figure 11d). The clock-correction term had median magnitudes of 1.81m to 8.61 m per anchor and reduced the median within-link spread by factors of 2.2–3.6 relative to the uncorrected term. This dependence on D j is consistent with the clock-offset sensitivity derived in Section 3.1.2. Received responses per recorded tag cycle were 97.0% for LOS and 98.0% for NLOS links (pooled); the median link exceeded 99%, and the lowest single-link values were 30.4% (LOS) and 82.0% (NLOS).

3.5.4. Synchronization and Dynamic References

All 4,195 consecutive intervals among the 4,214 paired pulse records had unit increments in both counters, and tag-clock and Mega-clock inter-pulse intervals differed by at most 23 μ s ; this shows internal consistency, not independently measured synchronization accuracy. Valid temporal references covered every UWB cycle in the synchronized-edge motion window and every IMU sample in the receipt-phase motion window (Table 5).
The median absolute encoder–chord difference was 1.44 c m ; the maximum was 9.20 c m , or 1.14% of the corresponding chord (Figure 10b). This tests distance consistency only, not intermediate positions.
Across all 19 runs, the unconstrained odometry end position differed from the final two-mast survey by a median of 0.12 m (IQR 0.09 m to 0.26 m ); five runs exceeded 0.25 m , and absolute end-heading differences were 0.76° to 5.85° (median 3.17°). Per-run values are stored in each quality_report.json. R19 had the maximum, 1.357 m ; its operator-confirmed final W6 transcription correction changed survey metadata and endpoint comparisons, not the reference CSVs. Distance agreement therefore does not validate unconstrained trajectories, and because endpoint-constrained references impose the surveyed endpointsd (Equation 17), their endpoint closure is not an independent validation.

3.5.5. Quality Flags and Interpretation

Static warnings included 15 negative ranges, four unavailable computed ranges, sequence gaps and missing diagnostics. These observations were retained, as were five negative dynamic ranges and 499 nonnegative dynamic ranges below the surveyed vertical antenna separation. The largest IMU gap was 2.531 s , so aggregate completeness does not imply an uninterrupted stream. None of the 65 NLOS links carries an obstruction description, and all static provenance records lacked anchor-source hashes. Stationarity and capture checks do not validate motion-dependent IMU errors or propagation labels.

4. Conclusion and Future Work

Version 1.0 combines 18 static and 19 robot-carried recordings from a furnished laboratory, with 199,621 received UWB ranges and 520,770 IMU samples. Raw measurements, calibration metadata, quality flags and separate static and dynamic reference products support studies of ranging-error mitigation and UWB–IMU localization.
The dataset also has limitations. All measurements come from one furnished laboratory and one radio configuration, with anchor antennas at 2.617m to 2.621 m and static tag antennas at 1.54m to 1.56 m above the floor, which limits vertical observability. The static LOS offset and within-link spread depend on the anchor reply interval (Section 3.5.3), so error models fitted to these data may not transfer to other reply intervals or radio settings. Only scalar radio diagnostics are provided; CIR data, device temperatures, NLOS obstruction descriptions, T1 orientation and laboratory headings were not recorded. Dynamic recordings use one tag on intended-straight paths, with model-dependent intermediate positions, a single trial for each long class and speed and an unmeasured BMX160-to-antenna lever arm. Future work includes independently tracked trajectories, repeated runs and obstruction annotations to strengthen motion-reference validation and assessment across operating conditions.

Funding

This study was carried out within the project A-MoVeR—“Mobilizing Agenda for the Development of Products & Systems towards Intelligent and Green Mobility” (operation no. 02/C05-i01.01/2022.PC646908627-00000069), funded by European resources through Portugal’s Recovery and Resilience Plan under the European Recovery and Resilience Facility, within the Next Generation EU framework.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The dataset described in this article (version 1.0) is openly available on Zenodo under the Creative Commons Attribution 4.0 International (CC BY 4.0) license at https://doi.org/10.5281/zenodo.24408981. The release includes field dictionaries, QC reports, a SHA-256 file inventory and a read-only example script for loading and joining the records. The acquisition firmware is not part of the release.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Abbreviations

CIR Channel impulse response CSV Comma-separated values
DS-TWR Double-sided two-way ranging FCS Frame check sequence
FPP First-path power GNSS Global navigation satellite system
GPIO General-purpose input/output I2C Inter-integrated circuit
IMU Inertial measurement unit IQR Interquartile range
JSON JavaScript Object Notation LOS Line-of-sight
MAC Medium access control MAD Median absolute deviation
MoCap Motion capture MQTT Publish/subscribe messaging protocol
NLOS Non-line-of-sight NR Not reported
NTP Network Time Protocol ODR Output data rate
OSR4 Fourfold oversampling mode PAC Preamble acquisition chunk
PAN Personal area network PHY Physical layer
PRF Pulse repetition frequency QC Quality control
QoS Quality of service RMSE Root mean square error
RPM Revolutions per minute RTK Real-time kinematic
RXPW Received signal power SHA-256 Secure Hash Algorithm, 256-bit
SS-TWR Single-sided two-way ranging TDoA Time difference of arrival
TWR Two-way ranging USB Universal Serial Bus
UTC Coordinated Universal Time UWB Ultra-wideband

References

  1. Zafari, F.; Gkelias, A.; Leung, K.K. A Survey of Indoor Localization Systems and Technologies. IEEE Communications Surveys & Tutorials 2019, 21, 2568–2599. [CrossRef]
  2. Bregar, K.; Mohorčič, M. Improving Indoor Localization Using Convolutional Neural Networks on Computationally Restricted Devices. IEEE Access 2018, 6, 17429–17441. [CrossRef]
  3. Maranò, S.; Gifford, W.M.; Wymeersch, H.; Win, M.Z. NLOS Identification and Mitigation for Localization Based on UWB Experimental Data. IEEE Journal on Selected Areas in Communications 2010, 28, 1026–1035. [CrossRef]
  4. Wymeersch, H.; Maranò, S.; Gifford, W.M.; Win, M.Z. A Machine Learning Approach to Ranging Error Mitigation for UWB Localization. IEEE Transactions on Communications 2012, 60, 1719–1728. [CrossRef]
  5. He, X.; Mo, L.; Wang, Q. An Attention-Assisted UWB Ranging Error Compensation Algorithm. IEEE Wireless Communications Letters 2023, 12, 421–425. [CrossRef]
  6. Fontaine, J.; Che, F.; Shahid, A.; Van Herbruggen, B.; Ahmed, Q.Z.; Abbas, W.B.; De Poorter, E. Transfer Learning for UWB Error Correction and (N)LOS Classification in Multiple Environments. IEEE Internet of Things Journal 2024, 11, 4085–4101. [CrossRef]
  7. Decawave Ltd. The Implementation of Two-Way Ranging with the DW1000. Application Note APS013, Decawave Ltd., 2017. Version 2.3. Available online: https://forum.qorvo.com/uploads/short-url/x34DrF7EW5fQP9wY3aNESqPKz8z.pdf (accessed on 12 November 2026).
  8. Shalaby, M.A.; Dahdah, N.; Ahmed, S.S.; Cossette, C.C.; Le Ny, J.; Forbes, J.R. MILUV: A Multi-UAV Indoor Localization Dataset with UWB and Vision. The International Journal of Robotics Research 2026, 45, 1627–1647. [CrossRef]
  9. Wilkinson, M.D.; Dumontier, M.; Aalbersberg, I.J.; et al. The FAIR Guiding Principles for Scientific Data Management and Stewardship. Scientific Data 2016, 3, 160018. [CrossRef]
  10. Sang, C.L.; Steinhagen, B.; Homburg, J.D.; Adams, M.; Hesse, M.; Rückert, U. Identification of NLOS and Multi-Path Conditions in UWB Localization Using Machine Learning Methods. Applied Sciences 2020, 10, 3980. [CrossRef]
  11. Ledergerber, A.; D’Andrea, R. Ultra-Wideband Angle of Arrival Estimation Based on Angle-Dependent Antenna Transfer Function. Sensors 2019, 19, 4466. [CrossRef]
  12. Peña Queralta, J.; Martínez Almansa, C.; Schiano, F.; Floreano, D.; Westerlund, T. UWB-Based System for UAV Localization in GNSS-Denied Environments: Characterization and Dataset. In Proceedings of the 2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2020, pp. 4521–4528. [CrossRef]
  13. Nguyen, T.M.; Yuan, S.; Cao, M.; Lyu, Y.; Nguyen, T.H.; Xie, L. NTU VIRAL: A Visual-Inertial-Ranging-Lidar Dataset, From an Aerial Vehicle Viewpoint. The International Journal of Robotics Research 2022, 41, 270–280. [CrossRef]
  14. Dümbgen, F.; Shalaby, M.A.; Holmes, C.; Cossette, C.C.; Forbes, J.R.; Le Ny, J.; Barfoot, T.D. STAR-loc: Dataset for STereo And Range-Based Localization. arXiv 2023. arXiv:2309.05518, . [CrossRef]
  15. Zhao, W.; Goudar, A.; Qiao, X.; Schoellig, A.P. UTIL: An Ultra-wideband Time-difference-of-arrival Indoor Localization Dataset. The International Journal of Robotics Research 2024, 43, 1443–1456. [CrossRef]
  16. Lee, B.; Choi, J.; Jeong, S.; Choi, J.; Oh, K.Y. Comprehensive Outdoor UWB Dataset: Static and Dynamic Measurements in LOS/NLOS Environments. Scientific Data 2025, 12, 1532. [CrossRef]
  17. Banks, A.; Gupta, R. MQTT Version 3.1.1. Oasis standard, OASIS Open, 2014. Available online: https://docs.oasis-open.org/mqtt/mqtt/v3.1.1/os/mqtt-v3.1.1-os.html (accessed on 13 November 2026).
  18. RAKwireless Technology Limited. WisBlock Module Catalog. RAKwireless Technology Limited, 2022. Available online: https://downloads.rakwireless.com/ebook/RAK_Catalog_WisBlock_Module_Eng_V2.0.pdf (accessed on 13 November 2026).
  19. Decawave Ltd. DW1000 Data Sheet. Decawave Ltd., 2017. Available through the Qorvo product page: https://www.qorvo.com/products/p/DW1000 (accessed on 13 November 2026).
  20. Mills, D.L.; Martin, J.; Burbank, J.; Kasch, W. Network Time Protocol Version 4: Protocol and Algorithms Specification. Request for Comments 5905, Internet Engineering Task Force, 2010. [CrossRef]
  21. InvenSense, Inc. MPU-9250 Product Specification. InvenSense, Inc., 2016. Available online: https://invensense.tdk.com/wp-content/uploads/2015/02/PS-MPU-9250A-01-v1.1.pdf (accessed on 13 November 2026).
  22. Bosch Sensortec GmbH. BMX160 Data Sheet. Bosch Sensortec GmbH, 2018. Available online: https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bmx160-ds000.pdf (accessed on 13 November 2026).
  23. maxon motor ag. EPOS 70/10 Hardware Reference. maxon motor ag, 2008. December 2008 edition. Available online: https://www.maxongroup.com/medias/sys_master/root/8834323808286/EPOS-70-10-Hardware-Reference-En.pdf (accessed on 13 November 2026).
  24. Tedaldi, D.; Pretto, A.; Menegatti, E. A Robust and Easy to Implement Method for IMU Calibration without External Equipments. In Proceedings of the 2014 IEEE International Conference on Robotics and Automation, 2014, pp. 3042–3049. [CrossRef]
  25. Qorvo, Inc. Antenna Delay Calibration of DW1000-Based Products and Systems. Application Note APS014, Qorvo, Inc., 2024. Revision 1.3. Available online: https://www.qorvo.com/products/r/ra007040 (accessed on 12 November 2026).
  26. Decawave Ltd. DW1000 User Manual. Decawave Ltd., 2017. Version 2.18, Section 7.2.40.11, p. 145 (carrier-integrator excerpt). Available online: https://forum.qorvo.com/uploads/short-url/c7XSaYL1FhtjdjV89lk4Gg1WXl5.pdf (accessed on 15 November 2026).
  27. Bosch Power Tools. GLM 80 Professional: Original Instructions. Robert Bosch Power Tools GmbH, 2019. Available online: https://www.bosch-professional.com/binary/manualsmedia/o320971v21_160992A55A_201908.pdf (accessed on 13 November 2026).
  28. Kong, J.; Pfeiffer, M.; Schildbach, G.; Borrelli, F. Kinematic and Dynamic Vehicle Models for Autonomous Driving Control Design. In Proceedings of the 2015 IEEE Intelligent Vehicles Symposium, 2015, pp. 1094–1099. [CrossRef]
Figure 1. Dataset v1.0 organization with selected session files.
Figure 1. Dataset v1.0 organization with selected session files.
Preprints 245602 g001
Figure 2. Measurement coverage: configured-link distances, response availability (received responses/recorded tag cycles, not scheduled opportunities), commanded motor RPM, and surveyed distance class by RPM.
Figure 2. Measurement coverage: configured-link distances, response availability (received responses/recorded tag cycles, not scheduled opportunities), commanded motor RPM, and surveyed distance class by RPM.
Preprints 245602 g002
Figure 3. Architecture of the experimental data acquisition system.
Figure 3. Architecture of the experimental data acquisition system.
Preprints 245602 g003
Figure 4. Hardware mounting photographs: static tag mast, wall-mounted anchor and robot-mounted T3. The robot panel predates the rear survey mast; its dimensional annotations are superseded by Table 7.
Figure 4. Hardware mounting photographs: static tag mast, wall-mounted anchor and robot-mounted T3. The robot panel predates the rear survey mast; its dimensional annotations are superseded by Table 7.
Preprints 245602 g004
Figure 5. Broadcast SS-TWR, IMU, and robot-data acquisition flows.
Figure 5. Broadcast SS-TWR, IMU, and robot-data acquisition flows.
Preprints 245602 g005
Figure 6. Electrical interface between T3 and the Arduino Mega synchronization input.
Figure 6. Electrical interface between T3 and the Arduino Mega synchronization input.
Preprints 245602 g006
Figure 7. Laboratory geometry and reference coordinate system, with fixed UWB anchors and surveyed static measurement positions.
Figure 7. Laboratory geometry and reference coordinate system, with fixed UWB anchors and surveyed static measurement positions.
Preprints 245602 g007
Figure 8. Static and dynamic measurement-acquisition workflows.
Figure 8. Static and dynamic measurement-acquisition workflows.
Preprints 245602 g008
Figure 9. Surveyed dynamic endpoints and endpoint-constrained straight references.
Figure 9. Surveyed dynamic endpoints and endpoint-constrained straight references.
Preprints 245602 g009
Figure 10. Reference consistency: (a) redundant static wall fits; (b) unadjusted encoder distance minus surveyed endpoint chord.
Figure 10. Reference consistency: (a) redundant static wall fits; (b) unadjusted encoder distance minus surveyed endpoint chord.
Preprints 245602 g010
Figure 11. Static ranging against surveyed reference ranges: (a) cumulative distribution of the signed error (reference minus estimate) for LOS and NLOS links; (b) LOS error by anchor and median reply interval, with boxes spanning the IQR and whiskers the 5th–95th percentiles; (c) median and IQR of the error in 1 m reference-range bins; (d) median over LOS links of the within-link spread (1.4826 MAD) of ranges computed without and with the clock-correction term.
Figure 11. Static ranging against surveyed reference ranges: (a) cumulative distribution of the signed error (reference minus estimate) for LOS and NLOS links; (b) LOS error by anchor and median reply interval, with boxes spanning the IQR and whiskers the 5th–95th percentiles; (c) median and IQR of the error in 1 m reference-range bins; (d) median over LOS links of the within-link spread (1.4826 MAD) of ranges computed without and with the clock-correction term.
Preprints 245602 g011
Table 1. Compact feature comparison of representative UWB datasets.
Table 1. Compact feature comparison of representative UWB datasets.
Dataset UWB Static Dynamic IMU Radio data LOS/NLOS scope Position reference
Bregar–Mohorčič [2] (localization) Ranges √ — — CIR, scalar Link Planar coordinates
Ledergerber–D’Andrea [11] TWR √ √ NR CIR Setup MoCap
Queralta et al. [12] TWR NR √ √* NR NR MoCap
NTU VIRAL [13] TWR NR √ √ Scalar NR Laser tracking
STAR-loc [14] DS-TWR √ √ √ Scalar * NR MoCap
UTIL [15] TDoA √ √ √* Scalar * Static tests MoCap
Lee et al. [16] SS-TWR √ √ √* Scalar Scenario Static geometry; RTK-GNSS
MILUV [8] DS-TWR √ √ √ CIR, scalar * Anchor setup MoCap
This work SS-TWR √ √ √* Scalar (tag, anchor) Static links Laser surveys; dynamic endpoints †
√: recorded; —: not in the documented record types; *subset only. Static includes fixed-position tests. Radio data distinguish scalar diagnostics from CIR waveforms. LOS/NLOS scope distinguishes link labels, static tests and scenario/obstacle configurations. †Intermediate dynamic positions are encoder/endpoint-constrained, not independently measured. Abbreviations are defined at the end of the paper.
Table 2. Static-session records.
Table 2. Static-session records.
File Record level and contents
session.json; raw.jsonl Session settings, geometry and provenance; dequeued MQTT envelopes
cycles.csv One tag cycle: identifiers, time, transmission status, response mask and counters
ranges.csv One received response: diagnostics, timing, range components, surveyed XYZ and reference error
imu.csv One sample: identity, time, calibrated acceleration and angular rate
imu_stationary_corrected.csv Original samples with separate residual gyroscope corrections and validity fields
imu_stationary_correction.json Correction assumptions, parameters, group results and provenance hashes
Table 3. Dynamic products by location; filenames are relative to each group.
Table 3. Dynamic products by location; filenames are relative to each group.
File or group Record level and contents
dynamic/<session-id>/
session.json, plan.json, run_metadata.json Executed configuration, status, counts and provenance
initial_survey.json, final_survey.json Front/rear wall distances and fitted positions, T3 XYZ, two-mast heading and wall-fit RMSE
MQTT, robot and host *.jsonl Raw payloads, telemetry, commands, acknowledgments and audit events
cycles.csv, ranges.csv, imu.csv, robot.csv Normalized cycles, received responses, IMU samples and controller telemetry
sync_pairs.csv Paired T3/Mega counters, times, boot IDs and synchronization run
trajectory_reference.csv Integrated trajectory; reference_kind=calibrated_odometry
cycle_reference.csv, imu_reference.csv Sensor-time odometry associations; referenceKind, referenceValid
quality_report.json Coverage, synchronization, gap and endpoint checks
dynamic-derived/
dynamic_run_manifest.csv Collection index; surveyed class, chord bearing and relative product paths
summary.json Run/class and row counts, reference kind and continuous-ground-truth flag
<session-id>/derived_metadata.json Source, assumptions, warnings; referenceKind, continuousGroundTruth=false
<session-id>/endpoint_constrained_trajectory.csv Encoder progress on the endpoint chord; pathKind
<session-id>/endpoint_constrained_cycle_reference.csv Motion-cycle chord positions; runLabel, placement, edgeToPathUs
Table 4. Essential timestamp conventions.
Table 4. Essential timestamp conventions.
Field/domain Interpretation
acquisitionMonoUs, publicationMonoUs Tag microseconds: cycle/read start (not IMU data-ready) and later serialization
Host receipt fields Monotonic nanoseconds or UTC receipt text; transport, not acquisition time
mega_us_unwrapped, position_sample_us_unwrapped Separate unwrapped Mega record and encoder-position sample times, in microseconds
DW1000 timestamp fields Node-local 40-bit counters; derived intervals remain in ticks, not a shared clock
Table 5. Audited recording inventory. Reference counts are valid/total.
Table 5. Audited recording inventory. Reference counts are valid/total.
Quantity Value
Static sessions / point identifiers 18 / 54
Configured static links 270 (205 LOS; 65 NLOS)
Static cycles / received responses / IMU samples 35,994 / 175,023 / 431,721
Static QC after documented survey correction 18 pass with warnings
Dynamic sessions / collection-QC-complete 19 / 19
Dynamic cycles / received responses 4,955 / 24,598
Dynamic IMU / robot records 89,049 / 7,845
Locally valid pulses / pairs / trajectory samples 4,955 / 4,214 / 5,531
Valid cycle references: all phases; motion QC window 3,578/4,955; 3,530/3,530
Valid IMU references: all phases; receipt-phase motion 64,373/89,049; 63,491/63,491
Table 6. Deployed UWB-node and IMU configuration.
Table 6. Deployed UWB-node and IMU configuration.
Parameter Specification
Tags / anchors RAK11200 (ESP32-WROVER) / RAK4631 (nRF52840); each with RAK13801 (DW1000) and RAK19007
Channel / PRF / data rate 5 / 16 MHz / 110 kbit s−1
Preamble / code / PAC 2048 symbols / 4 / 64 symbols
PAN / broadcast 0x1234 / 0xFFFF
T1–T3 addresses 0x0011, 0x0021, 0x0031
A1–A5 addresses 0x0012, 0x0022, 0x0032, 0x0042, 0x0052
Anchor timing Indices 1–5; 6 m s spacing, 250 μ s guard
Tag timing 60 m s slots; 180 m s superframe; T1–T3 offsets 0 ms, 60 ms and 120 ms; UTC from NTP [20]
Crystal trim / tag delays Trim 10 on all nodes; T1–T3 delays 16383, 16386, 16384
A1–A5 antenna delays 16596, 16600, 16597, 16565, 16584
T2 IMU MPU9250 [21]; 100 Hz ; digital low-pass filter enabled
T3 IMU BMX160 [22]; 200 Hz internal ODR, OSR4; 100 Hz acquisition target
IMU ranges / channels ±4 g , ±500 ∘ s−1; tri-axial acceleration and angular rate
Interface I2C, 100 kHz
Table 7. Robot and T3 mounting configuration.
Table 7. Robot and T3 mounting configuration.
Parameter Specification
Drive / steering Four-wheel car-like platform; rear-axle drive, front-wheel servo steering
Controllers Arduino Mega 2560; Maxon EPOS 70/10 [23]
Wheelbase / platform height 0.532 m / 0.144 m above floor
Motor incremental encoder 500 pulse rev−1; 2000 count rev−1
Forward encoder sign + 1
Distance scale / acquisition command 6.797 524 × 10−6  m count−1 / 1200 μs
Mast baseline / separation tolerance 0.4475 m / 0.010 m
T3 antenna offset / floor height ( 0.4645 , − 0.0250 , 1.2040 ) m } / 1.204 m
BMX160 sensor axes + Z s forward; + X s left; + Y s up
BMX160-to-antenna displacement Not measured
Table 8. Source-defined IMU coefficients in sensor-axis order ( X s , Y s , Z s ) .
Table 8. Source-defined IMU coefficients in sensor-axis order ( X s , Y s , Z s ) .
Coefficient T2 / MPU9250 T3 / BMX160
b a (m s−2) ( 0.264692 , 0.152917 , 0.349256 ) ( − 0.672009 , − 0.046951 , 0.529263 )
s a ( 1.000227 , 0.999967 , 1.009418 ) ( 1.018267 , 1.015473 , 1.024960 )
b ω (∘ s−1) ( − 0.852732 , − 1.608785 , − 0.640467 ) ( 0.163714 , − 0.481357 , − 0.689705 )
Table 9. Application-specific UWB frame structure, excluding the transceiver-appended two-byte FCS.
Table 9. Application-specific UWB frame structure, excluding the transceiver-appended two-byte FCS.
Bytes Field Encoding or meaning
0–1 Frame control 0x41, 0x88
2 Sequence 8-bit request sequence
3–4 PAN 16-bit PAN identifier
5–6 Destination Broadcast for polls; initiating tag for responses
7–8 Source Tag for polls; responding anchor for responses
9 Message type 2: poll; 3: response
10–14 t 2 , j Anchor poll-reception timestamp, 40-bit
15–19 t 3 , j Anchor response-transmission timestamp, 40-bit
20–33 Diagnostics Seven unsigned 16-bit values: first-path amplitudes 1–3, noise, CIR power, preamble count, and first-path index
34–37 FPP 32-bit floating-point value
38–41 RXPW 32-bit floating-point value
Table 10. Room vertices.
Table 10. Room vertices.
Vertex X (m) Y (m)
V1 0.0000 0.0000
V2 12.5590 0.0000
V3 12.4740 6.6090
V4 1.8478 6.5828
V5 1.8705 4.8180
V6 0.0620 4.8180
Table 11. Fixed anchor antenna coordinates.
Table 11. Fixed anchor antenna coordinates.
Anchor X (m) Y (m) Z (m)
A1 2.5857 0.0192 2.619
A2 2.4604 6.5656 2.621
A3 7.2072 6.5720 2.619
A4 12.3895 6.5974 2.617
A5 12.4944 0.0290 2.619
Table 12. Validation criteria and recorded outcomes. Rows marked descriptive have no acceptance gate.
Table 12. Validation criteria and recorded outcomes. Rows marked descriptive have no acceptance gate.
Check Criterion Observed outcome
Static stream completeness At least 95% of nominal UWB/IMU records All configured streams pass; minimum IMU completeness 97.69%
Static survey consistency Wall-fit RMSE ≤ 0.05 m 7/7 redundant (≥3-wall) fits pass after the documented P02 correction; 47 two-wall fits have no redundancy
Dynamic survey consistency Initial/final wall-fit RMSE ≤ 0.01 m All 76 front/rear planar fits use two walls; residuals provide no redundancy
Two-mast baseline consistency Absolute separation error ≤ 0.01 m 38/38 endpoint surveys pass; maximum 9.07 m m
Dynamic capture integrity Completed capture, verified stop and reference/collection checks 19/19 recordings pass their archived collection checks
Dynamic distance consistency | L e − L c | ≤ max ( 0.05 m , 0.02 L c ) 19/19 pass before endpoint scaling
Odometry endpoint agreement Descriptive Median 0.12 m ; maximum 1.357 m (R19); 5/19 runs above 0.25 m
Static ranging error Descriptive LOS median 0.34 m ; within-link spread 8.4 cm to 32.6 c m (Section 3.5.3)
Table 13. Static LOS ranging statistics by anchor. Errors are reference minus estimate. D j is the median reply interval; | d j ( clk ) | is the median magnitude of the clock-correction term. Spread is the median over LOS links of 1.4826 MAD of the range without/with the clock-correction term.
Table 13. Static LOS ranging statistics by anchor. Errors are reference minus estimate. D j is the median reply interval; | d j ( clk ) | is the median magnitude of the clock-correction term. Spread is the median over LOS links of 1.4826 MAD of the range without/with the clock-correction term.
Anchor D j (ms) | d j ( clk ) | (m) LOS links Median (m) IQR (m) Spread (cm)
A1 10.95 1.81 39 0.265 0.151–0.403 18.4 / 8.4
A2 16.95 8.61 39 0.366 0.235–0.487 43.6 / 13.9
A3 22.95 3.21 41 0.418 0.220–0.620 45.9 / 19.0
A4 28.95 5.57 42 0.213 0.009–0.414 81.3 / 27.0
A5 34.95 7.17 44 0.494 0.244–0.740 118.0 / 32.6
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.