Preprint
Article

This version is not peer-reviewed.

Field Measurement and Emission Quantification of Volatile Organic Compounds at a Crude Oil Storage Depot

Submitted:

12 November 2026

Posted:

17 November 2026

You are already at the latest version

Abstract
Crude oil storage depots are important sources of atmospheric volatile organic compound (VOC) emissions, contributing to air pollution and associated environmental concerns. In this study, VOC emissions from storage tanks at a typical crude oil depot were measured through field investigations, and emission rates were quantified at both the component and facility levels. The total VOC emissions were estimated based on field measurements, and the corresponding emission intensity was further evaluated. The results revealed substantial variations in component-level emission rates, with guide pillars exhibiting higher emission rates than breathing valves and support pillars. At the facility level, VOC emission rates ranged from 0.07 to 30.10 L/min, with guide pillars accounting for more than 44% of the total VOC emission rate associated with external floating-roof tanks. The total VOC emissions from the investigated crude oil depot were estimated at 422.24 tonnes, which was lower than the value obtained using engineering estimation methods. Furthermore, the population-averaged VOC emission intensity for typical crude oil depots in China was estimated to be 0.0076%. These findings provide field-based evidence of VOC emission characteristics at both the component and facility levels and highlight the importance of component-specific measurements for improving emission inventories and developing targeted emission-control strategies for crude oil storage depots.
Keywords: 
;  ;  ;  ;  

1. Introduction

At China continues to face challenges associated with fine particulate matter (PM₂.₅) and ozone (O₃) pollution. Particularly during summer, O₃ has been identified as a major pollutant affecting compliance with ambient air quality standards in urban areas [1]. Volatile organic compounds (VOCs) have been widely recognized as important precursors of O₃ and secondary particulate matter through atmospheric photochemical reactions [2,3,4]. Consequently, VOC emission control has been regarded as an important strategy for mitigating PM2.5 and O3 pollution [5]. Among various anthropogenic emission sources, petrochemical operations and petroleum storage facilities have been identified as significant contributors, with oil storage tanks being recognized as important sources of fugitive VOC emissions [6,7,8]. Currently, VOC emissions from storage tanks are commonly quantified using empirical approaches, calculation-based models, and direct field measurements. Among these methods, the approaches recommended in China's Guidelines for the Investigation of VOC Pollution Sources in the Petrochemical Industry and those developed by the United States Environmental Protection Agency (U.S. EPA) have been widely applied [9]. In previous studies, U.S. EPA methodologies, including AP-42 and the TANKS model, have been employed to estimate VOC emissions from storage tanks in Chinese petrochemical facilities. Floating-roof configuration, tank turnover, tank-wall condition, and rim-seal design have been identified as important factors influencing VOC emissions [10].
With the progressive implementation of VOC emission control measures in the petrochemical industry, increasing attention has been paid to VOC emissions from petroleum storage and transportation facilities. The total VOC emissions from urban oil depots in China have been estimated at approximately 169,000 tonnes. In a previous study, VOC emissions from storage tanks in representative petroleum storage facilities were estimated using the U.S. Environmental Protection Agency (EPA) TANKS model, and the field-measured emission values were found to be higher than the corresponding model estimates [11]. Furthermore, VOC emissions from external floating-roof crude oil storage tanks were quantified using the methods specified in China's of “Guidelines for the Investigation of VOC Pollution Sources in the Petrochemical Industry” and the EPA AP-42 methodology [12]. The estimated VOC emissions from the investigated crude oil storage depots were reported to be on the order of hundreds of tonnes.
Currently, calculation-based methods are predominantly used to estimate VOC emissions from oil storage depots. However, considerable discrepancies have been reported between model-based estimates and actual emissions under field operating conditions. In contrast, field measurement methods are considered more representative of the operational characteristics of oil storage and transportation facilities in China, allowing actual VOC emission levels to be more accurately characterized [13]. Nevertheless, field measurement-based VOC emission inventories for petroleum storage and transportation facilities remain insufficiently developed, limiting the accuracy and reliability of emission assessments and the implementation of targeted emission control strategies. In this study, VOC emissions from representative crude oil storage depots in China were systematically measured and quantified under actual operating conditions. Component- and facility-level emission rates were determined based on field measurements, and the total VOC emissions from the investigated depots were subsequently estimated. The findings are expected to provide a scientific basis for improving VOC emission inventories and developing more accurate emission assessment and control strategies for the petroleum storage and transportation sector.

2. Materials and Methods

2.1. Characteristics of the Investigated Crude Oil Storage Depots

Three representative crude oil storage depots in western, central, and eastern China were selected for field investigations. VOC emission sources were identified, and their emission rates were quantified through measurements conducted on eight external floating-roof storage tanks. The characteristics of the investigated depots and storage tanks are summarized in Table 1.

2.2. Field Measurements of VOC Emissions

Field measurements were conducted in three stages: leak source identification, emission rate quantification, and comprehensive sampling and compositional analysis. The monitoring procedures were primarily performed in accordance with the Emission Standard of Air Pollutants for Bulk Gasoline Terminals (GB 20950-2020). A portable flame ionization detector (DataFID, INFICON, USA) and a high-flow sampler (Hi-FLOW, Bacharach Inc., New Kensington, PA, USA) were employed to identify fugitive emission sources associated with floating-roof fittings and quantify total hydrocarbon emission rates from external floating-roof tanks. Specifically, potential leakage points were first screened using the flame ionization detector (FID), and the corresponding hydrocarbon concentrations were measured to identify emission locations [14,15]. Subsequently, a high-flow sampler was used to quantify total hydrocarbon emission rates, including methane and non-methane hydrocarbons, at the identified leakage points. Detailed specifications and operating parameters of the instruments have been reported in previous studies.
Figure 1. Measurement of VOCs emission on external floating roof tank.
Figure 1. Measurement of VOCs emission on external floating roof tank.
Preprints 243872 g001
To quantify VOC emission rates from crude oil storage tanks, the volumetric fraction of VOCs in the emitted gas was determined for each emission source. Gas samples were collected from external floating-roof tanks using SUMMA canisters at a sampling flow rate of 300 mL min⁻¹ for 10 min. Three sets of gas samples were collected from each tank, yielding a total of 24 samples from eight tanks. The collected samples were subsequently subjected to compositional analysis to determine the volumetric fractions of methane and individual VOC species. Finally, the VOC emission rates at individual leakage points were calculated based on the measured total hydrocarbon volumetric emission rates and the corresponding VOC volumetric fractions.

2.3. Data Processing

Total hydrocarbon emission rates at leakage points of external floating-roof tanks were quantified using a Hi-FLOW high-flow sampler, with a measurement duration of 15 min per leakage point. The emission rate for each source was calculated from the monitoring data obtained using the high-flow sampler, as expressed in Eq. (1).
V = ∑ n = i − 1 V i   / n (1)
where V represents the total hydrocarbon emission rate (L min⁻¹), n is the total measurement duration (min), and Vᵢ denotes the total hydrocarbon volume measured during the ith time interval (L). The VOC emission rate for each emission source was subsequently calculated using the total hydrocarbon emission rate and the corresponding VOC volumetric fraction, as expressed in Eq. (2).
EVOCs = V × CVOCs (2)
where CVOCs represents the volumetric fraction of VOCs in the emitted gas (dimensionless).
The annual VOC emission load was estimated based on the monitored VOC emission rates of each emission source, as described in Equation (3). The emission intensity was subsequently calculated from the estimated annual emissions using Equation (4).
A VOCs = ∑ i = 1 ( E VOCs i × t R × M / 22400000 )
IVOCs = AVOCs / Q (4)
where AVOCs represents the annual VOC emissions (tonnes); EiVOCs denotes the VOC emission rate of emission source i (L/min); tR represents the annual operating time of emission source i (min); M is the average molecular weight of VOCs, which was assumed to be 44 g/mol in this study; IVOCs denotes the VOC emission intensity; and Q represents the annual turnover volume (tonnes).

3. Results and Discussion

3.1. VOC Emission Characteristics of Crude Oil Storage Tanks

The organic compounds emitted from external floating-roof tanks at the crude oil storage depot were classified into methane and VOCs, with their concentrations and relative proportions presented in Table 2. The concentrations of total organic compounds emitted from the crude oil storage tanks ranged from several thousand to tens of thousands of mg/m³. VOCs accounted for more than 95% of the total organic compounds, whereas methane contributed less than 5%. These results indicated that VOCs were the predominant components of organic emissions from the crude oil storage depot.
More than 40 VOC species were identified through comprehensive compositional analysis of emissions from crude oil storage tanks, as listed in Table 3. These species were classified into four categories: alkanes, alkenes, aromatic hydrocarbons, and oxygenated compounds. The relative contributions of these categories are illustrated in Figure 2. Alkanes were the predominant components, accounting for more than 90% of the total VOCs. Aromatic hydrocarbons contributed 1.0%–5.8%, whereas alkenes and oxygenated compounds were detected at relatively low proportions, each accounting for less than 0.5% of the total VOCs.
VOC emissions from refinery units were dominated by alkanes, which accounted for 63.8–85.9% of the total VOCs [16]. Given that crude oil served as the primary feedstock for refinery operations, the VOC composition profiles of refinery emissions were generally consistent with those observed in emissions from crude oil storage tanks in the present study. However, a higher proportion of alkanes was observed in VOC emissions from crude oil storage tanks. This difference could be attributed to the transformation of hydrocarbons during refining processes, such as catalytic cracking, delayed coking, and catalytic reforming. During these processes, alkanes could undergo various chemical reactions, including dehydrogenation and cyclization, potentially increasing the relative proportions of aromatic hydrocarbons and alkenes while decreasing that of alkanes.
The alkanes emitted from crude oil storage tanks were further classified into three subgroups: n-alkanes, branched alkanes, and cycloalkanes, as illustrated in Figure 3. Marked differences were observed in the relative contributions of these subgroups to total alkanes. The proportions of n-alkanes, branched alkanes, and cycloalkanes ranged from 59.03% to 77.11%, 21.74% to 35.71%, and 1.49% to 9.25%, respectively. Among these subgroups, n-alkanes consistently exhibited the highest proportions, followed by branched alkanes and cycloalkanes, indicating that n-alkanes were the predominant components of alkane emissions from crude oil storage tanks. Although variations in the relative proportions of these subgroups were observed among the investigated tanks, the overall compositional pattern remained consistent, with n-alkanes accounting for the majority of total alkanes. These variations might be associated with differences in crude oil composition, hydrocarbon volatility, and tank operating conditions. In particular, differences in the physicochemical properties and vapor–liquid partitioning behavior of individual hydrocarbons could influence their relative abundances in the emitted vapors. Consequently, the observed alkane composition was likely influenced by both the original hydrocarbon composition of the stored crude oil and the preferential volatilization of individual compounds. These findings highlighted the predominance of n-alkanes in VOC emissions from crude oil storage tanks and provided further insight into the compositional characteristics of evaporative emissions during crude oil storage.
Based on carbon number, the detected alkanes were further classified into 11 groups (C2–C12), and their relative contributions are presented in Figure 4. Marked differences were observed in the relative abundances of alkanes with different carbon numbers. As the carbon number increased, the relative abundance of alkanes initially increased and subsequently decreased, with the highest contributions observed for C3–C5 alkanes. In particular, low-carbon alkanes, primarily C3, C4, and C5 compounds, were found to dominate the alkane emissions, whereas relatively low contributions were observed for higher-carbon-number alkanes (C6 and above). Further analysis of individual VOC species revealed that ethane (9.09%–11.34%), propane (17.09%–37.58%), n-butane (18.83%–26.40%), isobutane (7.64%–11.47%), n-pentane (5.80%–14.51%), and isopentane (6.05%–14.73%) were the major components of VOC emissions from crude oil storage tanks. Among these compounds, n-butane was identified as the predominant species in four tanks, whereas propane exhibited the highest relative abundance in the remaining four tanks. Further comparison of the C4 and C5 alkane isomers revealed that n-butane was generally more abundant than isobutane, while isopentane exhibited a higher relative abundance than n-pentane. Overall, the five most abundant VOC species collectively accounted for 65.68%–80.13% of the total VOCs, indicating that emissions from crude oil storage tanks were dominated by a limited number of low-carbon hydrocarbons.

3.2. Emission Characteristics of VOCs Released from Crude Oil Depot

The organic compounds emitted from external floating-roof crude oil storage tanks were classified into methane and VOCs, with their concentrations and relative proportions presented in Table 4. The concentrations of total organic compounds in the emitted gases ranged from several thousand to tens of thousands of mg/m³. VOCs accounted for more than 95% of the total organic compounds, whereas methane contributed less than 5%. These results indicated that VOCs were the predominant components of organic emissions from the crude oil storage depot.

3.3. Component-Levelcomponent-Level Emission Rate

A total of 52 VOC emission points were identified across the external floating-roof tanks at the investigated crude oil storage depots, including 10 guide poles (19.2%), 16 breather valves (30.8%), and 26 support columns (50.0%), as summarized in Table 5. Marked differences were observed in the distribution of emission points among the three crude oil storage depots. Support columns accounted for the largest proportion of identified emission points at the KEL depot, whereas breather valves were the predominant emission points at the LZK depot. In contrast, guide poles were identified as the primary emission points at the HDK depot. These results indicated that the distribution of VOC emission points varied considerably among the investigated crude oil storage depots, suggesting potential differences in tank configurations, component characteristics, and operating conditions.
Based on the monitoring data obtained using a high-flow sampler, the VOC emission rates from different floating-roof components were quantified, as illustrated in Figure 5. For external floating-roof crude oil storage tanks, the VOC emission rates from support columns ranged from 0.24 to 2.21 L/min, with an average of 0.89 L/min. The corresponding emission rates from breather valves ranged from 0.01 to 9.55 L/min, with an average of 1.09 L/min, whereas those from guide poles ranged from 1.61 to 6.43 L/min, with an average of 3.22 L/min. Among the three component, guide poles exhibited the highest average VOC emission rate, followed by breather valves and support columns. To further interpret these differences, the potential mechanisms responsible for VOC emissions from floating-roof components were examined. VOC emissions from external floating-roof crude oil storage tanks were primarily associated with withdrawal losses, rim seal losses, and deck fitting losses [17]. Among these pathways, deck fitting losses included emissions from components such as support columns, breather valves, and guide poles.
VOC emissions from floating-roof components were closely associated with their structural characteristics, sealing conditions, and operating states. Emissions from support columns were primarily attributed to deteriorated or loose rubber sealing gaskets, which allowed hydrocarbon vapors to escape through gaps between the columns and their sleeves. Breather valve emissions were mainly caused by valve opening during normal operation and leakage through imperfect seals. In contrast, guide pole emissions were associated with the evaporation of hydrocarbons from exposed crude oil surfaces and their subsequent release through openings in the guide pole walls. Considerable differences in component-specific emission characteristics were observed among the three crude oil storage depots. At the KEL depot, severe oxidative deterioration was observed in the rubber sealing gaskets of floating-roof support columns, resulting in substantial VOC leakage. By comparison, the corresponding gaskets at the LZK and HDK depots had recently been replaced, and no detectable leakage was observed from these components. At the LZK depot, guide poles without sidewall perforations were used, and breather valves were identified as the predominant VOC emission points, primarily associated with their opening during normal operation. At HDK depot, hydrocarbon odors were detected near the perforated guide poles, indicating potential vapor release through the sidewall openings. Accordingly, guide poles were identified as the predominant VOC emission points at this depot. These findings suggested that differences in component configurations, sealing integrity, and operating conditions could substantially influence the distribution of VOC emission points among crude oil storage depots.

3.4. Tank-Level Emission Rate

Based on the measured VOC emission rates from individual tank components, the overall VOC emission rates of external floating-roof crude oil storage tanks were quantified. Marked differences in tank-level VOC emission rates were observed among the investigated crude oil storage depots. The VOC emission rates of tanks at the LZK depot were relatively low, ranging from 0.07 to 0.37 L/min, with an average of 0.18 L/min. In contrast, considerably higher emission rates were observed at the KEL and HDK depots, ranging from 8.49 to 30.10 L/min and from 4.97 to 15.74 L/min, with average values of 19.29 and 11.26 L/min, respectively.
The contributions of different floating-roof components to the overall VOC emission rate were further quantified, as illustrated in Figure 6. The combined VOC emission rate from the eight external floating-roof crude oil storage tanks was estimated to be 72.91 L/min. Among the investigated components, guide poles were identified as the largest contributors, accounting for 44.24% of the total VOC emission rate, followed by support columns (31.82%) and breather valves (23.94%). However, marked differences were observed in the relative contributions of these components among the three crude oil storage depots. At the KEL depot, support columns accounted for the largest proportion of the total VOC emission rate, whereas breather valves were identified as the predominant emission sources at the LZK depot. In contrast, VOC emissions at the HDK depot were primarily attributed to guide pole losses. These differences were likely associated with variations in component configurations, sealing conditions, and the extent of leakage observed at the investigated storage tanks. Based on the identified emission characteristics and leakage mechanisms, targeted VOC emission mitigation measures were proposed for external floating-roof crude oil storage tanks. Regular leak detection and timely replacement of deteriorated support column seals were considered effective mitigation strategies. For KEL TANK-1 and KEL TANK-2, replacement of the support column rubber seals was estimated to reduce VOC emissions by 53.21% and 62.06%, respectively. Additional reductions could be achieved through the installation of low-leakage breather valves, optimization of valve pressure settings, and implementation of sealing improvements and vapor recovery systems for guide poles. These findings highlighted the potential of component-specific control strategies for mitigating VOC emissions from crude oil storage tanks.

3.5. Annual Emission Estimation

Annual VOC emissions from the three crude oil storage depots were estimated using both field measurement and emission factor-based calculation methods. Three emission pathways were considered: rim seal losses, withdrawal losses, and deck fitting losses. Deck fitting losses were quantified using both methods, whereas rim seal and withdrawal losses were estimated according to the “Guidelines for VOC Pollution Source Investigation in the Petrochemical Industry”. For the field measurement-based method, the monitored VOC emission rates were assumed to represent the annual average emission rates, while the parameters required for the calculation-based method were provided by the storage depots. The estimated annual VOC emissions are summarized in Table 6. Annual VOC emissions from deck fitting losses ranged from 45.25 to 91.63 t, depending on the estimation method, while those from rim seal and withdrawal losses were estimated at 6.46 and 324.15 t, respectively. Accordingly, total annual VOC emissions from the three depots ranged from 375.86 to 422.24 t. Notably, the calculation-based method yielded lower estimates of deck fitting emissions than the field measurement-based method, suggesting potential uncertainties in conventional emission estimation approaches. Further field measurements covering a broader range of storage tanks and operating conditions were recommended to improve the representativeness of emission rate data and the accuracy of VOC emission estimates.
The contributions of different emission sources to the annual VOC emissions from crude oil storage depots were further analyzed, as illustrated in Figure 7. Withdrawal losses were identified as the dominant emission source, accounting for 76.77% of the total VOC emissions from external floating-roof tanks, followed by deck fitting losses (21.70%). In contrast, rim seal losses contributed only 1.53% of the total emissions. These findings indicated that withdrawal losses were the predominant contributor to annual VOC emissions from external floating-roof crude oil storage tanks, highlighting the importance of prioritizing this emission pathway in VOC mitigation strategies.

3.6. Emission Intensity Analysis

The VOC emission intensity of external floating-roof crude oil storage tanks was estimated based on annual VOC emissions and crude oil throughput, as shown in Figure 8. Deck fitting losses were quantified using both field measurement and equation-based methods, whereas rim seal and withdrawal losses were estimated using the equation-based method. Crude oil throughput was defined as the cumulative amount of crude oil transferred into and out of the tanks annually. The estimated VOC emission intensities varied considerably among the investigated tanks, ranging from 0.47 to 1.44 t per 10⁴ t of crude oil throughput, with an average of 0.76 t per 104 t. This average was substantially lower than the value of 4.6 t per 104 t for crude oil storage tanks at typical European refineries [18]. Such differences might be associated with variations in tank configurations, operating conditions, crude oil properties, and emission estimation methods. These findings suggested that VOC emission intensities could vary considerably across different crude oil storage facilities.

4. Conclusions

Field measurements of VOC emissions were conducted at eight external floating-roof crude oil storage tanks across three representative storage depots in China, and the corresponding annual emissions and emission intensities were quantified. Support columns, breather valves, and guide poles were identified as the major component-level emission sources, with average emission rates of 0.89, 1.09, and 3.22 L/min, respectively. Tank-level emission rates ranged from 0.07 to 30.10 L/min, with a combined emission rate of 72.91 L/min. Guide poles contributed the largest proportion (44.24%) of the total measured emission rate, followed by support columns (31.82%) and breather valves (23.94%). The annual VOC emissions from the three depots were estimated at 422.24 t using field measurements combined with equation-based calculations, with withdrawal losses accounting for the largest proportion (76.77%). Higher estimates of deck fitting losses were obtained from field measurements than from equation-based calculations. The VOC emission intensities ranged from 0.47 to 1.44 t per 104 t of crude oil throughput, averaging 0.76 t per 104 t. These findings highlighted the importance of component-specific emission monitoring and targeted mitigation measures for improving VOC emission inventories and reducing emissions from crude oil storage facilities.

Author Contributions

Conceptualization, L.R. and D.C.; methodology, X.L.; software, Y.L.; validation, D.C., M.X. and X.L.; formal analysis, D.C.; investigation, L.R.; resources, D.C.; data curation, D.C.; writing—original draft preparation, L.R.; writing—review and editing, D.C.; visualization, Y.L.; supervision, L.T.; project administration, D.C.; funding acquisition, D.C. All authors have read and agreed to the published version of the manuscript.

Funding

This study was financially supported by China Petroleum Group Science and Technology Special Project (2023ZZ1302), National Oil and Gas Pipeline Network Science and Technology Project (XG-JCGL-CX-KJXX-01-JL-03/22306).

Data Availability Statement

The data presented in this study are available on request from the corresponding author. Please contact to caodd@cnpc.com.cn.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
VOCs Volatile organic compounds
EU European Union

References

  1. Zhu, J.; Chen, L.; Liao, H.; Dang, R. Correlations between PM2. 5 and ozone over China and associated underlying reasons. Atmosphere 2019, 10, 352. [Google Scholar] [CrossRef]
  2. Atkinson, R. Atmospheric chemistry of VOCs and NOx. Atmos. Environ. 2000, 34, 2063–2101. [Google Scholar] [CrossRef]
  3. David, E.; Niculescu, V. C. Volatile organic compounds (VOCs) as environmental pollutants: occurrence and mitigation using nanomaterials. Int. J. Env. Res. Pub. He. 2021, 18, 13147. [Google Scholar] [CrossRef] [PubMed]
  4. Paolin, E.; Strlič, M. Volatile organic compounds (VOCs) in heritage environments and their analysis: a review. Appl. Sci. 2024, 14, 4620. [Google Scholar] [CrossRef]
  5. Ziemann, P. J.; Atkinson, R. Kinetics, products and mechanisms of secondary organic aerosol formation. Chem. Soc. Rev. 2012, 41, 6582–6605. [Google Scholar] [CrossRef] [PubMed]
  6. Wu, R.; Bo, Y.; Li, J.; Li, L.; Li, Y.; Xie, S. Method to establish the emission inventory of anthropogenic volatile organic compounds in China and its application in the period 2008–2012. Atmos. Environ. 2016, 127, 244–254. [Google Scholar] [CrossRef]
  7. Zhang, Z.; Wang, H.; Chen, D.; Li, Q.; Thai, P.; Gong, D.; Wang, B. Emission characteristics of volatile organic compounds and their secondary organic aerosol formation potentials from a petroleum refinery in Pearl River Delta, China. Sci. Total Environ. 2017, 584, 1162–1174. [Google Scholar] [CrossRef] [PubMed]
  8. Feng, Y.; Xiao, A.; Jia, R.; Zhu, S.; Gao, S.; Li, B.; Zou, B. Emission characteristics and associated assessment of volatile organic compounds from process units in a refinery. Environ. Pollut. 2020, 265, 115026. [Google Scholar] [CrossRef] [PubMed]
  9. Mo, Z.; Shao, M.; Lu, S.; Qu, H.; Zhou, M.; Sun, J.; Gou, B. Process-specific emission characteristics of volatile organic compounds (VOCs) from petrochemical facilities in the Yangtze River Delta, China. Sci. Total Environ. 2015, 533, 422–431. [Google Scholar] [CrossRef] [PubMed]
  10. Saikomol, S.; Thepanondh, S.; Laowagul, W. Emission losses and dispersion of volatile organic compounds from tank farm of petroleum refinery complex. J. Environ. Health Sci. 2019, 17, 561–570. [Google Scholar] [CrossRef] [PubMed]
  11. Cheng, L.; Wei, W.; Zhang, C.; Xu, X.; Sha, K.; Meng, Q.; Cheng, S. Quantitation study on VOC emissions and their reduction potential for coking industry in China: Based on in-situ measurements on treated and untreated plants. Sci. Total Environ. 2022, 836, 155466. [Google Scholar] [CrossRef] [PubMed]
  12. Naidoo, T.; Naidoo, P.; Moodley, K. An analysis of petroleum storage tank emissions and procedures to reduce the resulting environmental impact. Sci. Comm. 2021, 20, 44. [Google Scholar]
  13. Liu, Y.; Xie, Q.; Li, X.; Tian, F.; Qiao, X.; Chen, J.; Ding, W. Profile and source apportionment of volatile organic compounds from a complex industrial park. Environ. Sci. Proc. Imp. 2019, 21, 9–18. [Google Scholar] [CrossRef] [PubMed]
  14. Pacsi, A. P.; Ferrara, T.; Schwan, K.; Tupper, P.; Lev-On, M.; Smith, R.; Ritter, K. Equipment leak detection and quantification at 67 oil and gas sites in the Western United States. Elem. Sci. Anth. 2019, 7, 29. [Google Scholar] [CrossRef]
  15. Zimmermann, S.; Krippner, P.; Vogel, A.; Müller, J. Miniaturized flame ionization detector for gas chromatography. Sensor. Actuat. B-Chem. 2002, 83, 285–289. [Google Scholar] [CrossRef]
  16. Zhang, C.; Xu, T.; Wu, G.; Gao, F.; Liu, Y.; Gong, D.; Wang, B. Reduction of fugitive VOC emissions using leak detection and repair (LDAR) in a petroleum refinery of Pearl River Delta, China. Appl. Energ. 2022, 324, 119701. [Google Scholar] [CrossRef]
  17. Yang, H.; Ren, B.; Huang, Y.; Zhang, Z.; Hu, W.; Liu, M.; Hao, Z. Volatile organic compounds (VOCs) emissions from internal floating-roof tank in oil depots in Beijing: Influencing factors and emission reduction strategies analysis. Sci. Total Environ. 2024, 916, 170222. [Google Scholar] [CrossRef] [PubMed]
  18. Wang, D.; Li, Y.; Pu, Y.; Lv, Y.; Wang, M.; Yang, H.; Li, D. Vertical Distribution Mapping for Methane Fugitive Emissions Using Laser Path-Integral Sensing in Non-Cooperative Open Paths. Sensors 2024, 24, 1307. [Google Scholar] [CrossRef] [PubMed]
Figure 2. Composition characteristics of tank related VOCs.
Figure 2. Composition characteristics of tank related VOCs.
Preprints 243872 g002
Figure 3. Composition characteristics of taliphatic VOCs.
Figure 3. Composition characteristics of taliphatic VOCs.
Preprints 243872 g003
Figure 4. Contribution of alkane with different carbon number to total aliphatic VOCs.
Figure 4. Contribution of alkane with different carbon number to total aliphatic VOCs.
Preprints 243872 g004
Figure 5. Emission rate of VOCs for components on external floating roof tank.
Figure 5. Emission rate of VOCs for components on external floating roof tank.
Preprints 243872 g005
Figure 6. Composition characteristics of VOCs emission rate for external floating tank.
Figure 6. Composition characteristics of VOCs emission rate for external floating tank.
Preprints 243872 g006
Figure 7. Composition of annual VOCs emission amount for crude oil depot.
Figure 7. Composition of annual VOCs emission amount for crude oil depot.
Preprints 243872 g007
Figure 8. Emission intensity of VOCs for external floating roof tank.
Figure 8. Emission intensity of VOCs for external floating roof tank.
Preprints 243872 g008
Table 1. Basic information for crude oil depots.
Table 1. Basic information for crude oil depots.
Order
number
Name of oil
storage tank
Type of
storage oil
Type and volume of tank Completion
status
First KEL Crude oil External floating roof (100000m3) Two seats (KEL TANK-1、KEL TANK-2)
Second LZK Crude oil External floating roof (100000m3) Four seats (LZK TANK-1、LZK TANK-2、LZK TANK3、LZK TANK4)
Third HDK Crude oil External floating roof (100000m3) Two seats
(HDK TANK-1、HDK TANK-2)
Table 2. Concentrations of Organic Emissions from Crude Oil Storage Tanks.
Table 2. Concentrations of Organic Emissions from Crude Oil Storage Tanks.
Order
number
Total hydrocarbon concentration
mg×m-3
Methane fraction
%
VOCsfraction
%
KEL TANK-1 8874.90 1.07 98.93
KEL TANK-2 1520.40 3.97 96.03
LZK TANK-1 30580.00 4.19 95.81
LZK TANK-2 1799.60 1.43 98.57
LZK TANK-3 4160.00 0.68 99.32
LZK TANK-4 5050.50 1.08 98.92
HDK TANK-1 2344.00 0.81 99.19
HDK TANK-2 2760.60 0.67 99.33
Table 3. VOC Species Identified in Emissions from Crude Oil Storage Tanks.
Table 3. VOC Species Identified in Emissions from Crude Oil Storage Tanks.
Alkanes Alkenes Aromatic hydrocarbons Oxygenated volatile organic compounds
ethane 2,3-dimethylbutane ethene benzene acetone
2,3-dimethylb-utane 2-methylpentane propene toluene methyl tert-butyl-ether
propane 3-methylpentane trans-2-butene ethylbenzene ethyl acetate
2-methylpe-ntane 2,4-dimethylpentane 1-butene m/p-xylene
isobutane methylcyclopentane cis-2-butene o-xylene
3-methylpe-ntane 2-methylhexane cumene
n-butane n-propylbenze-ne
2,4-dimethylpen-tane 2,3-dimethylpentane 1,3,5-trimethyl-benzene
isopentane 3-methylhexane 1,2,4-trimethyl-benzene
Methylcyclop-entane 2,2,4-trimethylpentane 1,2,3-trimethyl-benzene
n-pentane methylcyclohexane
2-methylhex-ane 2,3,4-trimethylpentane
n-hexane 2-methylheptane
2,3-dimethylpe 3-methylheptane
n-heptane n-dodecane
3-methylhexane
n-octane
Table 4. Composition of leaky components on external floating roof tank.
Table 4. Composition of leaky components on external floating roof tank.
Tank Number Guide pillar Breather Valve Floating disk support Total
KEL TANK-1 2 12 14
KEL TANK-2 2 2 14 18
LZK TANK-1 7 7
LZK TANK-2 2 2
LZK TANK-3 2 2
LZK TANK-4
HDK TANK-1 2 2 4
HDK TANK-2 2 2
Table 5. Composition of leaky components on external floating roof tank.
Table 5. Composition of leaky components on external floating roof tank.
Tank Number Guide pillar Breather Valve Floating disk support Total
KEL TANK-1 2 12 14
KEL TANK-2 2 2 14 18
LZK TANK-1 7 7
LZK TANK-2 2 2
LZK TANK-3 2 2
HDK TANK-1 2 2 4
HDK TANK-2 2 2
HDK TANK-3 2 1 3
Table 6. Estimation of annual VOCs emission amount for crude oil depot.
Table 6. Estimation of annual VOCs emission amount for crude oil depot.
Tank farm Loss of floating roof attachments Edge seal loss (ton) Wall-hanging loss (ton)
Emissions by on-site monitoring (ton) Emissions based on the formula method (ton)
KEL 45.63 9.23 1.28 56.19
LZK 4.78 4.77 1.65 131.72
HDK 41.22 31.24 3.54 136.24
Total 91.63 45.25 6.46 324.15
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.