Preprint
Article

This version is not peer-reviewed.

Biometry and Interdevice Differences in Primary Angle-Closure Disease with Unilateral Zonulopathy: A Paired-Eye Study

Submitted:

25 October 2026

Posted:

26 October 2026

You are already at the latest version

Abstract
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.
Keywords: 
;  ;  ;  ;  

1. Introduction

Primary angle-closure disease (PACD) encompasses primary angle-closure suspect (PACS), primary angle closure (PAC), and primary angle-closure glaucoma (PACG), involving appositional or synechial closure of the anterior chamber angle by the peripheral iris [1]. PACG carries a substantial burden of irreversible blindness. A meta-analysis of 23 studies found that 27.0% of individuals with PACG were blind in at least one eye [2]. Early lens extraction is an effective and cost-effective treatment option for selected patients with PAC or PACG [3]. However, coexisting zonulopathy presents a challenge during cataract surgery. Reported frequencies of intraoperatively identified zonulopathy vary across surgical cohorts, from 7.3% of PACD eyes [4] to 69.0% of patients in an acute angle-closure (AAC) subgroup [5]. Preoperative recognition is important for surgical planning, given the associated risks of vitreous loss, posterior capsule rupture, and poorer postoperative visual outcomes [6,7].
Preoperative identification remains challenging because subtle zonular abnormalities may escape routine examination and become apparent only during surgery. Anterior segment imaging and biometric measurements may provide additional clues. Ultrasound biomicroscopy (UBM) can reveal absent or elongated zonular fibers, alongside indirect findings such as increased lens sphericity and ciliary body flattening [8]. In patients with PACS, zonular weakness has also been associated with shallower anterior chamber depth (ACD) and more anterior positioning of the ciliary body [9]. However, subtle zonulopathy may remain undetected. Studies using anterior segment optical coherence tomography (AS-OCT) have further characterized lens position and morphology in patients with zonulopathy, although differences in ACD, lens vault (LV), and lens thickness (LT) have not been consistent across populations [10,11,12]. The biometric features of preoperatively occult zonulopathy in PACD therefore warrant further investigation, particularly using measurements obtained during routine cataract assessment.
Differences between devices may offer complementary information. Chen et al. reported a larger ACD discrepancy between UBM and IOLMaster in eyes with AAC secondary to lens subluxation than in eyes with acute primary angle closure. This difference was also significantly associated with lens subluxation in multivariable logistic regression [13]. Whether comparable interdevice differences are associated with occult zonulopathy in PACD remains unclear.
We therefore conducted a paired-eye study comparing preoperative clinical and biometric characteristics between PACD eyes with intraoperatively identified zonulopathy and their fellow eyes without zonulopathy. Using IOLMaster, Pentacam, and UBM measurements, we explored interdevice differences in ACD and pupil diameter as potential correlates of occult zonulopathy.

2. Materials and Methods

2.1. Study Design and Participants

This single-center observational paired-eye study was conducted at the Department of Ophthalmology, Peking University Third Hospital, Beijing, China. Clinical, biometric, and operative records were reviewed for patients with PACD undergoing bilateral cataract surgery from March 2023 to March 2026. The study adhered to the Declaration of Helsinki and was approved by the Ethics Committee of Peking University Third Hospital (S20260030). Written informed consent was obtained from all participants.
Patients were eligible if they had PACD, underwent cataract surgery in both eyes, and had intraoperatively confirmed zonulopathy in one eye with no zonulopathy identified in the fellow eye. Operative records and videos had to permit assessment of zonular status in both eyes. The two eyes of each patient constituted a matched pair. Exclusion criteria were clinically evident preoperative zonulopathy, including iridodonesis, phacodonesis, a visible lens equator through an undilated pupil, lens decentration, or spontaneous vitreous prolapse [14]; ocular trauma or an established alternative cause of zonular insufficiency, such as pseudoexfoliation syndrome, inherited lens ectopia, connective tissue disorders (e.g., Marfan syndrome), or retinitis pigmentosa [4]; secondary angle closure; or insufficient operative material to determine zonular status. Patients with zonulopathy in both eyes or in neither eye were excluded.

2.2. Clinical Definitions and Preoperative Assessment

PACD was classified as PACS, PAC, or PACG according to the American Academy of Ophthalmology Primary Angle-Closure Disease Preferred Practice Pattern [1]. PACS was characterized by at least 180° of iridotrabecular contact without elevated intraocular pressure (IOP), peripheral anterior synechiae, or glaucomatous optic neuropathy. PAC additionally involved elevated IOP and/or peripheral anterior synechiae, without glaucomatous optic neuropathy; PACG involved angle closure with glaucomatous optic neuropathy. A history of an AAC attack and previous laser peripheral iridotomy (LPI) were extracted from the clinical records. An AAC attack was defined by characteristic symptoms (such as ocular or periocular pain, headache, nausea, or vomiting) and signs (such as conjunctival injection, corneal epithelial edema, and a shallow anterior chamber), presenting IOP >21 mmHg, and angle closure in all four quadrants on gonioscopy [15].
Corrected distance visual acuity (CDVA) was measured using standard Snellen charts. Decimal acuity was converted to the logarithm of the minimum angle of resolution (logMAR). Counting fingers and hand motion were assigned logMAR values of 1.7 and 2.0 respectively [16]. IOP was measured using a non-contact tonometer (CT-800; Topcon Corporation, Japan). Slit-lamp biomicroscopy (BM 900; Haag-Streit AG, Switzerland) was used for anterior-segment examination. Lens opacity was graded using the Lens Opacities Classification System III, including nuclear opalescence (NO), nuclear color (NC), cortical opacity (C), and posterior subcapsular opacity (P) [17]. Visual-field status was assessed using Humphrey mean deviation (MD) and categorized using a simplified MD-based scheme: mild, MD ≥ −6 dB; moderate, −12 dB ≤ MD < −6 dB; and severe, MD < −12 dB [18].

2.3. Preoperative Examinations

Preoperative optical measurements were obtained using the IOLMaster 700 (Carl Zeiss Meditec AG, Germany) and Pentacam HR (Oculus Optikgeräte GmbH, Germany) under mesopic illumination (3–5 lux) without pharmacologic pupil dilation. Only IOLMaster measurements meeting the instrument software’s quality criteria and Pentacam scans passing the software quality check were accepted. IOLMaster parameters included axial length (AL), white-to-white corneal diameter (WTW), mean keratometry (Kmean), keratometric astigmatism (|ΔK|), central corneal thickness (CCT), ACD, LT, and pupil diameter. IOLMaster ACD was corrected by subtracting CCT from the instrument-measured distance between the anterior corneal surface and anterior lens surface, thereby representing internal ACD. Keratometric astigmatism was expressed as the absolute magnitude of ΔK. Lens position (LP) was calculated as corrected IOLMaster ACD + LT/2. Pentacam parameters comprised internal ACD, anterior chamber volume (ACV), pupil diameter, and alpha and kappa distances. ACV was expressed in cubic millimeters (mm³), CCT in micrometers (μm), keratometry in diopters (D), and the remaining measurements in millimeters (mm).
UBM (SW-3200L; Tianjin Suowei Electronic Technology Co., Ltd., China) examinations were performed by an experienced physician (D.A.) masked to the clinical data. Patients were examined supine in a dimly lit room after topical anesthesia with 1% tetracaine in both eyes. Radial scans centered over the limbus were obtained at the 12, 3, 6, and 9 o’clock positions, together with a vertical central anterior-segment scan through the pupillary center. All measurements were performed using the instrument’s built-in calipers. ACD was measured along the central axis from the posterior corneal surface to the anterior lens surface. Pupil diameter was measured between the opposing pupillary margins on the vertical central scan [19]. Images with uncertain scan planes or indistinct anatomical boundaries were considered ungradable for the corresponding parameter. Each measurement was repeated three times, and the mean value was used for analysis. UBM reports were reviewed for the circumferential extent of angle closure and angle narrowing, recorded as 0, one-quarter, one-half, three-quarters, or the entire circumference. Zero closure indicated verified absence of closure. The presence and extent of closure and the recorded extent of narrowing were analyzed.
Four interdevice differences were evaluated: UBM minus IOLMaster ACD, UBM minus Pentacam ACD, Pentacam minus UBM pupil diameter, and IOLMaster minus UBM pupil diameter. Each difference was calculated separately for each eye before the within-patient comparison. Paired contrasts were defined as the value in the eye with zonulopathy minus that in the fellow eye.

2.4. Intraoperative Determination of Zonular Status

All operations were performed by the same surgeon (Q.H.) and recorded in high-definition video. Zonulopathy was identified by anterior capsular radial folds or wrinkles during or immediately after capsulorhexis, or visualization of equatorial lens structures or abnormal zonular fibers after pupillary dilation [10]. The same criteria were applied to both eyes of every patient. The surgeon’s assessment was independently verified by a masked investigator (L.Y.Y.) through surgical video review using a standardized assessment form. Disagreements were resolved through joint review and discussion. The two individual assessments were used to evaluate inter-rater agreement, and the final classification defined the paired-eye groups.

2.5. Statistical Analysis

Statistical analyses were performed using R version 4.4.1. Continuous variables were summarized as mean ± standard deviation, lens-opacity grades and angle-extent measures as median [interquartile range], and categorical variables as counts and percentages. Paired comparisons used two-sided Wilcoxon signed-rank tests for continuous and ordinal outcomes and exact McNemar tests for binary outcomes; MD categories were analyzed as an ordered variable. Analyses used outcome-specific complete pairs without imputation. The Benjamini–Hochberg procedure was applied separately to 13 clinical and 19 biometric comparisons; unadjusted P values and adjusted q values were reported, with q < 0.05 indicating statistical significance. Inter-rater agreement was assessed using percentage agreement and Cohen’s κ. Percentile bootstrap 95% confidence intervals (CIs) for κ and mean paired contrasts were obtained using 20,000 patient-level resamples, retaining the paired-eye structure. CIs were not adjusted for multiplicity. Post hoc sensitivity analyses repeated paired comparisons of IOLMaster internal ACD, LP, ACV, Pentacam pupil diameter, and the four interdevice differences in patients without previous AAC in either eye, with separate Benjamini–Hochberg correction across these eight comparisons.

3. Results

3.1. Baseline Characteristics

The study included 57 patients and 114 eyes: 57 eyes with zonulopathy and 57 fellow eyes without intraoperatively identified zonulopathy. Mean age was 69.7 ± 8.7 years (range, 47–89 years), and 36 patients (63.2%) were women. The two evaluators agreed on zonular status in 112 of 114 eyes (98.2%; Cohen’s κ = 0.965; 95% CI, 0.912–1.000), with two discordant assessments resolved by joint review.
Baseline characteristics were presented in Table 1. CDVA did not differ significantly between eyes with zonulopathy and fellow eyes (0.36 ± 0.44 versus 0.26 ± 0.22 logMAR; P = 0.352, q = 0.352). Eyes with zonulopathy had higher NO, NC, and C grades (q = 0.012, 0.027, and 0.012, respectively). IOP, posterior subcapsular opacity, AL, Kmean, keratometric astigmatism, and WTW did not differ significantly after adjustment. IOLMaster pupil diameter and WTW were available for 56 complete pairs; ACV, UBM ACD, UBM pupil diameter, and angle-extent measures were available for 55 pairs. MD categories were available for 56 pairs. The remaining measurements were available for all 57 pairs.

3.2. PACD and Angle-Closure Characteristics

PACD and angle-closure characteristics were summarized in Table 2. PACG was diagnosed in 53 eyes with zonulopathy (93.0%) and 28 fellow eyes (49.1%; both P and q < 0.001). A previous AAC attack was recorded in 30 eyes with zonulopathy (52.6%) and 5 fellow eyes (8.8%; both P and q < 0.001). The remaining diagnoses were PAC in 2 versus 3 eyes and PACS in 2 versus 26 eyes, respectively. Eyes with zonulopathy had more extensive UBM-detected angle closure (P = 0.002, q = 0.010). Median closure involved 25% of the circumference (interquartile range, 0–62.5%) versus 0% (0–25%) in fellow eyes. Any closure was present in 28/55 eyes (50.9%) versus 17/55 (30.9%; P = 0.035, q = 0.0501). Prior LPI did not differ significantly (35/57 versus 31/57; P = 0.125, q = 0.158). Among 56 complete pairs with visual field data, mild, moderate, and severe categories occurred in 30 (53.6%), 15 (26.8%), and 11 (19.6%) eyes with zonulopathy, respectively, compared with 39 (69.6%), 12 (21.4%), and 5 (8.9%) fellow eyes (P = 0.025, q = 0.041).

3.3. Paired-Eye Biometric Characteristics

Biometric comparisons were presented in Table 3. Eyes with zonulopathy had shallower anterior chambers on all three devices: corrected IOLMaster ACD was 1.50 ± 0.40 versus 1.82 ± 0.35 mm, UBM ACD was 1.66 ± 0.37 versus 1.95 ± 0.34 mm, and Pentacam ACD was 1.52 ± 0.39 versus 1.84 ± 0.36 mm (all P and q < 0.001). LP was lower in eyes with zonulopathy (4.03 ± 0.33 versus 4.37 ± 0.28 mm; both P and q < 0.001), and ACV was smaller (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; both P and q < 0.001). LT did not differ significantly (5.06 ± 0.47 versus 5.09 ± 0.35 mm; P = 0.997, q = 0.997), nor did the Pentacam alpha (P = 0.424, q = 0.503) or kappa (P = 0.675, q = 0.726) distances. Pentacam pupil diameter was larger in eyes with zonulopathy (3.63 ± 1.19 versus 3.13 ± 0.64 mm; P = 0.004, q = 0.012). Neither IOLMaster pupil diameter (3.44 ± 1.16 versus 3.19 ± 0.70 mm; P = 0.258, q = 0.372) nor UBM pupil diameter (3.09 ± 1.07 versus 2.88 ± 0.89 mm; P = 0.331, q = 0.419) differed significantly.

3.4. Exploratory Interdevice Differences

Interdevice differences between eyes with zonulopathy and fellow eyes are presented in Table 4. UBM minus IOLMaster ACD differed between paired eyes (P < 0.001, q = 0.002), although the mean paired contrast of +0.038 mm had a 95% CI spanning zero (−0.003 to +0.074 mm). UBM minus Pentacam ACD was greater in eyes with zonulopathy (mean paired contrast, +0.033 mm; 95% CI, +0.007 to +0.059 mm; P = 0.007, q = 0.017). Pentacam minus UBM pupil diameter was also greater (mean paired contrast, +0.281 mm; 95% CI, +0.091 to +0.479 mm; P = 0.011, q = 0.023). IOLMaster minus UBM pupil diameter did not differ significantly (mean paired contrast, +0.115 mm; 95% CI, −0.064 to +0.297 mm; P = 0.274, q = 0.372). Individual within-patient contrasts are shown in Figure 1.

3.5. Sensitivity Analysis

The sensitivity analysis included 25 patient pairs with no previous AAC attack in either eye (Table S1). Mean paired contrasts were −0.11 mm for IOLMaster internal ACD (P = 0.135), −0.14 mm for LP (P = 0.011), and −6.8 mm³ for ACV (P = 0.076). The Pentacam pupil-diameter contrast was +0.08 mm (P = 0.440). UBM minus IOLMaster ACD remained greater in eyes with zonulopathy (mean paired contrast, +0.027 mm; P = 0.014), whereas the other three interdevice comparisons were not nominally significant (P = 0.126–0.954).

3.6. Representative Case

Figure 2 illustrates the paired-eye anterior segment findings in a 59-year-old woman with unilateral occult zonulopathy. The left eye had PACG, a previous AAC attack, and intraoperatively identified zonulopathy; the right fellow eye had PACS without identified zonulopathy. Both eyes had undergone LPI. Slit-lamp examination showed a shallower anterior chamber in the left eye (Figure 2A, B). In the left and right eyes, respectively, UBM showed ACDs of 1.76 and 2.12 mm and pupil diameters of 2.13 and 1.58 mm (Figure 2C, D). Pentacam measurements were 1.57 and 2.02 mm for ACD, 56.0 and 67.0 mm³ for ACV, and 3.13 and 1.68 mm for pupil diameter (Figure 2E, F).

4. Discussion

In this paired-eye study of patients with PACD, eyes with occult zonulopathy were more likely to have a history of AAC attacks and showed greater angle-closure extent and higher MD-based visual-field severity than their fellow eyes. They also had a shallower anterior chamber, lower LP, and smaller ACV. Selected interdevice differences in ACD and pupil diameter were greater in eyes with zonulopathy. Together, these findings associate occult zonulopathy with a more crowded anterior segment and more severe clinical manifestations of PACD.
Previous surgical series suggest that zonulopathy is relatively common in PACD, although reported frequencies vary considerably. Salimi et al. [4] identified zonulopathy in 59 of 806 PACD eyes (7.3%), comprising 12 PACS eyes (7.1%), 23 PAC eyes (6.6%), and 24 PACG eyes (8.4%). Zhang et al. [5] reported zonulopathy in 53 of 176 PACD eyes (30.1%). By comparison, large routine cataract surgery cohorts reported zonular dialysis in approximately 0.5%–0.6% of eyes [20,21]. These estimates are not directly interchangeable because patient selection and definitions differ, particularly when subtle zonular laxity is included. Qiao et al. found a higher proportion of underdiagnosed zonulopathy in acute than in chronic angle-closure glaucoma (57.1% versus 29.3%), consistent with the association with previous AAC attacks in our study [22]. The greater angle-closure extent and higher visual-field severity in affected eyes further support an association between zonulopathy and disease severity.
The combination of a shallower anterior chamber, lower LP, and smaller ACV indicates greater anterior segment crowding in eyes with zonulopathy. Earlier biometric studies largely focused on AAC, in which distinguishing primary angle closure from angle closure associated with zonular abnormalities can be challenging. In 68 eyes of 56 patients with a history of AAC, Kwon and Sung [12] found that eyes with zonular instability had longer AL, shallower ACD, and higher LV. Xing et al. [23] also reported shallower ACD and lower LP in eyes with AAC secondary to occult lens subluxation than in eyes with acute primary angle closure. Disproportionately shallow ACD relative to AL and marked interocular ACD asymmetry have been proposed as clues to zonular compromise [19,24]. Findings regarding LT are less consistent: Chen et al. reported thicker lenses in an acute primary angle-closure cohort with zonular abnormalities [25], whereas another AAC study found no significant LT difference between eyes with and without zonular laxity [19]. In our broader PACD cohort, LT likewise did not differ between paired eyes. This pattern is more consistent with a difference in lens position than with lens thickening.
The interdevice ACD findings raise the possibility that measurements obtained under different postural conditions reflect differences in lens position. Chen et al. reported a larger UBM–IOLMaster ACD discrepancy in AAC secondary to lens subluxation and proposed that supine UBM and seated optical biometry might reveal increased lens mobility [13]. In our cohort, both UBM minus IOLMaster ACD and UBM minus Pentacam ACD differed between paired eyes, although the mean contrasts were small, at approximately 0.038 and 0.033 mm. The UBM–IOLMaster mean-contrast CI included zero despite the significant signed-rank test; the two analyses summarize different aspects of the paired differences. Posture-related lens movement is a plausible explanation, but device-specific measurement methods and acquisition conditions provide alternatives. Our study focused on PACD with intraoperatively identified zonulopathy and did not isolate the effect of posture or directly measure lens mobility.
The larger Pentacam minus UBM pupil-diameter difference in eyes with zonulopathy may reflect differences in illumination and acquisition conditions. Pupil diameter varies with ambient illumination, and device illumination, fixation targets, and measurement timing may produce different pupillary states [26]. Previous AAC-related iris damage could also influence these responses. Our study did not include standardized pupillary light-response testing, and the IOLMaster minus UBM comparison was not significant after multiplicity adjustment. Future studies combining controlled illumination, dynamic pupillometry, and independent assessment of zonular status could examine whether pupil responses provide additional information. The present finding should therefore be treated as an exploratory association.
The relationship between zonulopathy and PACD remains debated. The 2025 Chinese expert consensus on PACG recognizes abnormal lens position associated with zonular abnormalities as a mechanism of angle closure [27]. Reduced zonular support could allow anterior lens displacement and increase anterior segment crowding, whereas elevated IOP and accompanying tissue changes could further damage the zonules, creating a potentially reciprocal relationship [28]. A complementary hypothesis proposes that a pressure difference across the lens, arising from resistance to aqueous flow at the cilio-lenticular interface, drives anterior displacement of the lens–iris diaphragm. Recent experimental work in rabbits supports this pressure-driven mechanism, but does not establish its contribution in human PACD with occult zonulopathy [29]. Our cross-sectional observations cannot determine whether zonular abnormalities preceded angle closure or developed as a consequence of it.
A principal strength of this study is its paired-eye design, which controls for age, sex, and many shared systemic and genetic factors. Both eyes had PACD, allowing comparison within the same disease spectrum. Zonular status was determined using intraoperative findings and masked video review, with high inter-rater agreement. Multimodal biometry provided complementary descriptions of anterior segment anatomy, and the examination of interdevice differences extended the analysis beyond measurements from individual instruments. These findings provide potential clues for preoperative recognition of occult zonulopathy.
Several limitations should be acknowledged. First, the sample of 57 patients limited precision and was insufficient for developing and validating a reliable prediction model. Patients with bilaterally normal zonules were not included as a separate PACD control group. Second, the small PACS and PAC subgroup precluded meaningful subgroup analyses. AAC history was markedly imbalanced between eyes, and the sensitivity analysis without AAC history included only 25 pairs. Third, subtle abnormalities may have been missed in the fellow eye despite standardized intraoperative criteria and review by two evaluators. High agreement within this selected sample does not exclude shared assessment bias. Fourth, the interdevice analyses remain exploratory, with unadjusted CIs and no independent validation; the contributions of device, posture, illumination, and measurement timing could not be separated. Finally, selection of patients undergoing bilateral cataract surgery with unilateral zonulopathy limits generalizability of the findings to the broader PACD population, and prevents estimation of zonulopathy prevalence in PACD.

5. Conclusions

Among patients with PACD and unilateral occult zonulopathy, affected eyes showed more severe angle-closure features, a shallower anterior chamber, a more anterior lens position, and smaller anterior chamber volume. Selected interdevice ACD and pupil differences may provide additional clues to occult zonulopathy, but their clinical value requires confirmation in larger prospective studies with standardized measurement conditions.

Supplementary Materials

The following supporting information can be downloaded at the website of this paper posted on Preprints.org.

Funding

This work was supported by the National Natural Science Foundation of China (grant numbers 82171022 and 82371026 to Hong Qi and 82560202 to Qianqian Lan) and the Natural Science Foundation of Guangxi Zhuang Autonomous Region (grant number 2025GXNSFDA069056 to Qianqian Lan).

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of Peking University Third Hospital (S20260030).

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Gedde, S.J.; Chen, P.P.; Muir, K.W.; Vinod, K.; Lind, J.T.; Wright, M.M.; Li, T.; Mansberger, S.L.; American Academy of Ophthalmology Preferred Practice Pattern Glaucoma Panel. Primary Angle-Closure Disease Preferred Practice Pattern®. Ophthalmology 2021, 128, P30–P70. [CrossRef]
  2. George, R.; Panda, S.; Vijaya, L. Blindness in glaucoma: Primary open-angle glaucoma versus primary angle-closure glaucoma—A meta-analysis. Eye 2022, 36, 2099–2105. [CrossRef]
  3. Azuara-Blanco, A.; Burr, J.; Ramsay, C.; Cooper, D.; Foster, P.J.; Friedman, D.S.; Scotland, G.; Javanbakht, M.; Cochrane, C.; Norrie, J.; et al. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): A randomised controlled trial. Lancet 2016, 388, 1389–1397. [CrossRef]
  4. Salimi, A.; Fanous, A.; Watt, H.; Abu-Nada, M.; Wang, A.; Harasymowycz, P. Prevalence of zonulopathy in primary angle closure disease. Clin. Exp. Ophthalmol. 2021, 49, 1018–1026. [CrossRef]
  5. Zhang, H.; Zhang, Y.; Zhang, S.; Cao, K.; Li, D.; Liu, M.; Liang, J.; Song, J.; Wang, N.; Qiao, C. Zonulopathy identified during cataract extraction in patients with primary angle closure disease. J. Glaucoma 2023, 32, 783–791. [CrossRef]
  6. Aiello, F.; Rampat, R.; Gallo Afflitto, G.; Din, N.; Mandal, N.; Maurino, V. Zonular dialysis and cataract surgery: Results from a UK tertiary eye care referral centre. Can. J. Ophthalmol. 2024, 59, 67–72. [CrossRef]
  7. Elhusseiny, A.M.; Toma, J.; Fouad, Y.A.; Soliman, M.K.; Ibrahim, S.N.; Shakarchi, A.F.; Ellabban, A.A.; Yang, Y.C.; Sallam, A.B. Outcomes of cataract surgery complicated with zonular dialysis: A multicenter comparative study. Curr. Eye Res. 2025, 50, 258–263. [CrossRef]
  8. Pavlin, C.J.; Buys, Y.M.; Pathmanathan, T. Imaging zonular abnormalities using ultrasound biomicroscopy. Arch. Ophthalmol. 1998, 116, 854–857. [CrossRef]
  9. Ma, J.; Jiang, N.; Jiang, Z.; Lin, J.; Li, C.; Zhao, G. Ultrasound biomicroscopy observation of suspicious primary angle closure combined with the relaxation of zonule. J. Ophthalmol. 2022, 2022, 1614678. [CrossRef]
  10. Yuan, H.; Jiang, X.; Liu, Z.; Li, X. Lens morphology in cataract patients with zonular dialysis by AS-OCT. J. Cataract Refract. Surg. 2025, 51, 860–866. [CrossRef]
  11. Pei, X.-T.; Wang, S.-H.; Qing, G.-P.; Yu, X.-W.; Shi, Y.; Yang, W.-L.; Wang, N.-L.; Fan, Z.-G. Zonular instability-associated morphologic features in eyes with primary angle closure disease using the swept-source anterior segment–optical coherence tomography system. BMC Ophthalmol. 2024, 24, 203. [CrossRef]
  12. Kwon, J.; Sung, K.R. Factors associated with zonular instability during cataract surgery in eyes with acute angle closure attack. Am. J. Ophthalmol. 2017, 183, 118–124. [CrossRef]
  13. Chen, X.; Song, Q.; Yan, W.; Wang, Z.; Cai, B.; Zhang, Y.; Zhong, H.; Chen, Q. Evaluation of multimodal biometric parameters for diagnosing acute angle closure secondary to lens subluxation. Ophthalmol. Ther. 2023, 12, 839–851. [CrossRef]
  14. Shingleton, B.J.; Neo, Y.N.; Cvintal, V.; Shaikh, A.M.; Liberman, P.; O’Donoghue, M.W. Outcome of phacoemulsification and intraocular lens implantion in eyes with pseudoexfoliation and weak zonules. Acta Ophthalmol. 2017, 95, 182–187. [CrossRef]
  15. Sng, C.C.A.; Aquino, M.C.D.; Liao, J.; Ang, M.; Zheng, C.; Loon, S.C.; Chew, P.T.K. Pretreatment anterior segment imaging during acute primary angle closure: Insights into angle closure mechanisms in the acute phase. Ophthalmology 2014, 121, 119–125. [CrossRef]
  16. Pichi, F.; Dolz-Marco, R.; Francis, J.H.; Au, A.; Davis, J.L.; Fawzi, A.; Gattousi, S.; Goldstein, D.A.; Keane, P.A.; Miserocchi, E.; et al. Advanced OCT analysis of biopsy-proven vitreoretinal lymphoma. Am. J. Ophthalmol. 2022, 238, 16–26. [CrossRef]
  17. Chylack, L.T., Jr.; Wolfe, J.K.; Singer, D.M.; Leske, M.C.; Bullimore, M.A.; Bailey, I.L.; Friend, J.; McCarthy, D.; Wu, S.Y. The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. Arch. Ophthalmol. 1993, 111, 831–836. [CrossRef]
  18. Atalay, E.; Nongpiur, M.E.; Yap, S.C.; Wong, T.T.; Goh, D.; Husain, R.; Perera, S.A.; Aung, T. Pattern of visual field loss in primary angle-closure glaucoma across different severity levels. Ophthalmology 2016, 123, 1957–1964. [CrossRef]
  19. Chen, H.; Ye, L.; Cheng, L.; Chen, L.; Lin, J.; Li, Y.; Ye, D.; Lu, P.; Huang, J. Ocular biometric characteristics in preoperative diagnosis of acute angle closure with and without zonular laxity. J. Glaucoma 2024, 33, 195–205. [CrossRef]
  20. Trikha, S.; Agrawal, S.; Saffari, S.-E.; Jayaswal, R.; Yang, Y.F. Visual outcomes in patients with zonular dialysis following cataract surgery. Eye 2016, 30, 1331–1335. [CrossRef]
  21. Soliman, M.K.; Hardin, J.S.; Jawed, F.; Uwaydat, S.H.; Faramawi, M.F.; Chu, C.J.; Yang, Y.C.; Sallam, A.B. A database study of visual outcomes and intraoperative complications of postvitrectomy cataract surgery. Ophthalmology 2018, 125, 1683–1691. [CrossRef]
  22. Qiao, C.Y.; Zhang, H.; Zhang, Y.; Zhang, S.; Li, D.J.; Song, X.D.; Yang, Y.Q.; Wang, X.F.; Yao, N.; Chen, C.; et al. Comparison study for the proportion of underdiagnosed zonulopathy in angle closure glaucoma. Zhonghua Yan Ke Za Zhi 2022, 58, 872–881. [CrossRef]
  23. Xing, X.; Huang, L.; Tian, F.; Zhang, Y.; Lv, Y.; Liu, W.; Liu, A. Biometric indicators of eyes with occult lens subluxation inducing secondary acute angle closure. BMC Ophthalmol. 2020, 20, 87. [CrossRef]
  24. Fairaq, R.; Alshaikh, L.; Khan, S.A.; Bin Helayel, H.; Al Habash, A.; Almutlak, M. Zonular compromise: A narrative review of indicators and management strategies. Saudi J. Ophthalmol. 2025, 39, 354–360. [CrossRef]
  25. Chen, H.; Yin, J.; Wu, Y.; Wang, Y.; Liu, Y.; Dong, W.; Gao, B.; Li, R.; Cheng, S.; Wang, L. Zonular ligament abnormalities intermingled in acute primary angle closure: A diagnostic and therapeutic challenge. Heliyon 2024, 10, e34939. [CrossRef]
  26. Martínez-Plaza, E.; Marcos, M.; López-de la Rosa, A.; López-Miguel, A.; Maldonado, M.J. Reliability and agreement of apparent chord mu measurements between static and dynamic evaluations. J. Cataract Refract. Surg. 2023, 49, 21–28. [CrossRef]
  27. Glaucoma Group of Ophthalmology Branch of Chinese Medical Association; Glaucoma Group of Chinese Ophthalmologist Association. Chinese expert consensus on the diagnosis and treatment of primary angle-closure glaucoma (2025). Zhonghua Yan Ke Za Zhi 2025, 61, 652–660. [CrossRef]
  28. Huang, J.; Huang, C. Zonulopathy and its relation to primary angle closure disease: A review. J. Glaucoma 2024, 33, 931–939. [CrossRef]
  29. Zheng, X.; Zhao, F.; Chen, H.; Lin, H.; Li, J.; Zhang, J.; Wang, X.; Zuo, J.; Luo, G.; Liang, Y. A novel rabbit model of angle-closure glaucoma via ciliary block and elevated trans-lens pressure difference. Invest. Ophthalmol. Vis. Sci. 2025, 66, 60. [CrossRef]
Figure 1. Paired-eye contrasts in interdevice differences. For each patient, the interdevice difference in the fellow eye was subtracted from that in the eye with zonulopathy. ACD, anterior chamber depth; UBM, ultrasound biomicroscopy; CI, confidence interval.
Figure 1. Paired-eye contrasts in interdevice differences. For each patient, the interdevice difference in the fellow eye was subtracted from that in the eye with zonulopathy. ACD, anterior chamber depth; UBM, ultrasound biomicroscopy; CI, confidence interval.
Preprints 240326 g001
Figure 2. Paired-eye anterior segment findings in a 59-year-old woman with unilateral occult zonulopathy. (A, B) Anterior-segment photographs. (C, D) UBM central anterior-segment scans. (E, F) Pentacam Scheimpflug images. ACD, anterior chamber depth; ACV, anterior chamber volume.
Figure 2. Paired-eye anterior segment findings in a 59-year-old woman with unilateral occult zonulopathy. (A, B) Anterior-segment photographs. (C, D) UBM central anterior-segment scans. (E, F) Pentacam Scheimpflug images. ACD, anterior chamber depth; ACV, anterior chamber volume.
Preprints 240326 g002
Table 1. Baseline and general ocular characteristics.
Table 1. Baseline and general ocular characteristics.
Characteristic n Zonulopathy eye Fellow eye P value q value
Age (years) 57 69.7 ± 8.7 69.7 ± 8.7 — —
Female sex, n (%) 57 36 (63.2) 36 (63.2) — —
CDVA (logMAR) 57 0.36 ± 0.44 0.26 ± 0.22 0.352 0.352
IOP (mmHg) 57 14.4 ± 4.4 13.8 ± 3.8 0.158 0.172
Nuclear opalescence grade 57 2.0 [1.0, 2.0] 2.0 [1.0, 2.0] 0.005 0.012
Nuclear color grade 57 2.0 [2.0, 3.0] 2.0 [1.0, 2.0] 0.015 0.027
Cortical opacity grade 57 2.0 [2.0, 3.0] 2.0 [2.0, 2.0] 0.005 0.012
Posterior subcapsular opacity grade 57 1.0 [1.0, 2.0] 1.0 [1.0, 2.0] 0.134 0.158
Axial length (mm) 57 22.78 ± 0.85 22.76 ± 0.81 0.687 0.726
Kmean (D) 57 44.25 ± 1.47 44.14 ± 1.47 0.105 0.165
Keratometric astigmatism |ΔK| (D) 57 1.03 ± 0.79 0.87 ± 0.59 0.073 0.127
WTW (mm) 56 11.6 ± 0.4 11.7 ± 0.4 0.053 0.100
CDVA, corrected distance visual acuity; IOP, intraocular pressure; Kmean, mean keratometry; WTW, white-to-white corneal diameter. NO, nuclear opalescence; NC, nuclear color; C, cortical opacity; P, posterior subcapsular opacity.
Table 2. PACD and angle-closure characteristics.
Table 2. PACD and angle-closure characteristics.
Characteristic n Zonulopathy eye Fellow eye P value q value
PACG, n (%) 57 53 (93.0) 28 (49.1) <0.001 <0.001
Previous acute angle-closure attack, n (%) 57 30 (52.6) 5 (8.8) <0.001 <0.001
Angle-closure extent (% circumference) 55 25.0 [0.0, 62.5] 0.0 [0.0, 25.0] 0.002 0.010
Any angle closure, n (%) 55 28 (50.9) 17 (30.9) 0.035 0.0501
Prior LPI, n (%) 57 35 (61.4) 31 (54.4) 0.125 0.158
Visual-field MD category 56 — — 0.025 0.041
Mild, n (%) 56 30 (53.6) 39 (69.6) — —
Moderate, n (%) 56 15 (26.8) 12 (21.4) — —
Severe, n (%) 56 11 (19.6) 5 (8.9) — —
PACD, primary angle-closure disease; PACG, primary angle-closure glaucoma; LPI, laser peripheral iridotomy; MD, mean deviation.
Table 3. Biometric measurements.
Table 3. Biometric measurements.
Characteristic n Zonulopathy eye Fellow eye P value q value
IOLMaster ACD (mm) 57 1.50 ± 0.40 1.82 ± 0.35 <0.001 <0.001
Pentacam ACD (mm) 57 1.52 ± 0.39 1.84 ± 0.36 <0.001 <0.001
UBM ACD (mm) 55 1.66 ± 0.37 1.95 ± 0.34 <0.001 <0.001
Lens thickness (mm) 57 5.06 ± 0.47 5.09 ± 0.35 0.997 0.997
Lens position (mm) 57 4.03 ± 0.33 4.37 ± 0.28 <0.001 <0.001
Pentacam ACV (mm³) 55 59.9 ± 24.0 75.4 ± 22.8 <0.001 <0.001
IOLMaster pupil diameter (mm) 56 3.44 ± 1.16 3.19 ± 0.70 0.258 0.372
Pentacam pupil diameter (mm) 57 3.63 ± 1.19 3.13 ± 0.64 0.004 0.012
UBM pupil diameter (mm) 55 3.09 ± 1.07 2.88 ± 0.89 0.331 0.419
Pentacam alpha distance (mm) 57 0.44 ± 0.13 0.44 ± 0.15 0.424 0.503
Pentacam kappa distance (mm) 57 0.32 ± 0.19 0.31 ± 0.20 0.675 0.726
ACD, anterior chamber depth; LT, lens thickness; LP, lens position; ACV, anterior chamber volume; CCT, central corneal thickness; UBM, ultrasound biomicroscopy.
Table 4. Interdevice differences.
Table 4. Interdevice differences.
Characteristic n Zonulopathy eye Fellow eye P value q value
UBM − IOLMaster ACD (mm) 55 0.158 ± 0.125 0.120 ± 0.076 <0.001 0.002
UBM − Pentacam ACD (mm) 55 0.140 ± 0.104 0.107 ± 0.080 0.007 0.017
Pentacam − UBM pupil diameter (mm) 55 0.52 ± 0.65 0.24 ± 0.65 0.011 0.023
IOLMaster − UBM pupil diameter (mm) 54 0.38 ± 0.65 0.26 ± 0.64 0.274 0.372
UBM, ultrasound biomicroscopy; ACD, anterior chamber depth.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.