Preprint
Article

This version is not peer-reviewed.

Finite-Training-Sample Calibration of Energy Detectors Under Improper Complex Gaussian Noise

Submitted:

17 October 2026

Posted:

19 October 2026

You are already at the latest version

Abstract
Energy-detector thresholds depend on the noise distribution, which is often estimated from independent signal-free training observations. We study how finite training samples affect false alarm calibration under zero-mean improper complex Gaussian noise. We compare an oracle threshold, a covariance plug-in threshold, and a refitted parametric-bootstrap calibration. The normalized energy law supplies a deterministic evaluation of conditional false-alarm probabilities, avoiding an additional test-sample Monte Carlo layer. Exact Wishart sampling replaces explicit bootstrap training vectors without changing the covariance-estimation distribution. We distinguish training uncertainty, bootstrap simulation uncertainty, and outer Monte Carlo uncertainty, and conduct an independent, precision-planned confirmation study comprising 119,183 training experiments. For K ∈ {50,100,200}, η ∈ {0,0.5,0.9} and α ∈ {0.05,0.01}, every bootstrap bias interval at budgets 1999 and 4999 lies inside the prespecified tolerance ±0.05α. The plug-in detector meets that criterion at 5 of 18 grid points, falls materially outside it at 10, and is inconclusive at 3. All 18 paired budget comparisons meet the average-calibration tolerance. These findings support practical marginal calibration on the tested grid, not exact finite-sample CFAR or universal MSE superiority. Uniform absolute-calibration bounds establish ideal-bootstrap consistency; finite-budget limits distinguish marginal bias from persistent calibration randomness.
Keywords: 
;  ;  ;  ;  ;  

1. Introduction

An energy detector declares a signal when the energy of a cell under test exceeds a threshold. Even under a correctly specified Gaussian noise model, estimating the threshold from a finite training set can change the achieved false-alarm probability. Improper complex noise adds a covariance-shape parameter: the energy distribution depends on both total power and the imbalance between the real covariance eigenvalues. The covariance and complementary-covariance description of such data is standard in improper-complex signal processing [1,2].
The research question is therefore: for an energy detector under known-zero-mean improper complex Gaussian noise, how does covariance estimation from K independent training observations affect false-alarm calibration, and to what extent can refitted parametric-bootstrap calibration restore the nominal level?
Our analysis separates exact oracle calibration, asymptotic calibration of estimated detectors, and empirical finite-sample accuracy. The simulation design evaluates the true conditional rejection probability of each fitted threshold rather than estimating it through additional random test decisions. An exact covariance-distribution shortcut makes the bootstrap study practical at larger training sizes. Classical Wishart sampling and Bartlett decomposition are computational tools, not new distributional results claimed by this work [3,4]. Parameter refitting within simulated datasets follows standard fitted-model bootstrap principles [5,6].

1.1. Related Work and Scope of the Contribution

The modulus and angle of a zero-mean normal complex variate were already studied by Hoyt [7]; the underlying Gaussian energy law is not itself claimed as novel here. Schreier and Scharf [1,2] provide the second-order framework for improper complex data. Multisensor detection involving improper signals and noise has also been studied, for example through frequency-domain generalized likelihood-ratio tests [8]; that construction differs from calibrating the raw energy of one complex observation.
Finite-reference energy detection is an important direct precedent. Mariani, Giorgetti and Chiani [9] analyze estimated noise power in proper Gaussian noise. For independent sensing and noise-reference windows they obtain an exact F distribution and explicitly connect the model to cell-averaging constant-false-alarm-rate (CA-CFAR) detection. Their scalar power-estimation problem differs from unrestricted covariance fitting, which estimates impropriety even when the true covariance is proper. In adaptive Gaussian detection, covariance-invariant matched-filter procedures already provide CFAR for their respective statistics [10]. Covariance mismatch is another source of false-alarm distortion [11]; here training and test covariances are matched, so estimation uncertainty is isolated from mismatch.
Bootstrap detector calibration also has substantial predecessors. Ong and Zoubir [12] derive higher-order approximation results for a residual-bootstrap matched filter using Edgeworth expansions. Their later detector [13] uses residual moving-block resampling and signal-parameter refitting without independent noise-only training. Wang Jing and Jin Yong [14] apply bootstrap calibration to a parametric adaptive matched filter with autoregressive disturbance modeling. In that title, “parametric” describes the detector and does not identify the fitted-Gaussian bootstrap used here. Bootstrap energy detection is also present in Huang’s thesis [15], using a studentized energy statistic, known noise power and nonparametric resampling. Neither bootstrap thresholds nor repeated fitting are new principles introduced by the present work.
Our fitted-CDF calibration belongs to the prepivoting framework of Beran [5]. General bootstrap and nuisance-parameter Monte Carlo theory [6,16] provides context for asymptotic validity, but does not automatically supply a detector-specific higher-order error rate or exact finite-sample CFAR. Moreover, tolerance-interval bootstrap detectors [17] target confidence that a random threshold keeps false alarms below a specified level. That one-sided confidence objective differs from the marginal-bias tolerance evaluated here.
Against this background, the present study combines three elements:
1.
a conditional and marginal calibration analysis for raw energy under unrestricted covariance fitting from independent improper-Gaussian training;
2.
detector-specific uniform absolute-calibration and finite-budget bias bounds, separating training uncertainty from bootstrap randomization;
3.
exact covariance-law computation and an independent finite-grid study with prespecified precision targets for calibration and budget sensitivity.
These describe the scope of the contribution rather than assert priority for bootstrap CFAR, the energy law or covariance sampling. No universal finite-sample bias, variance, MSE or detection-power dominance is claimed.

2. Noise Model and Calibration Objectives

Under the noise-only hypothesis H 0 , write Z j = X j + i Y j and W j = ( X j , Y j ) T . Assume
W 0 , W 1 , … , W K independent , W j ∼ N 2 ( 0 , Σ ) , Σ = a b b c > 0 .
The mean is known to be zero. The cell under test W 0 is independent of the training set T K = ( W 1 , … , W K ) . Define
E 0 = | Z 0 | 2 = ∥ W 0 ∥ 2 , Σ ^ K = 1 K ∑ j = 1 K W j W j T , K ≥ 2 .
Here K Σ ^ K ∼ W 2 ( K , Σ ) , with positive-definite Σ ^ K almost surely. Centering an estimated mean would change the degrees of freedom and estimator normalization and is outside this model. Set
γ = tr Σ , κ = E Z j 2 = a − c + 2 i b , η = | κ | γ ∈ [ 0 , 1 ) .
The eigenvalues are λ 1 , 2 = γ ( 1 ± η ) / 2 ; properness is η = 0 . Estimated parameters are obtained from the eigenvalues of Σ ^ K without imposing properness, even when the true noise is proper.
For a threshold fixed after observing training and calibration randomness U B , let
A m , B ( T K , U B ; Σ ) = P Σ { E 0 > τ m , B ( T K , U B ) ∣ T K , U B } .
For the plug-in and oracle procedures omit U B and B. We distinguish
P FA , m , B = E A m , B , b m , B = P FA , m , B − α , v m , B = Var ( A m , B ) , MSE m , B = v m , B + b m , B 2 .
The expectation for finite-budget bootstrap averages both training and calibration randomness. Small marginal bias does not imply that every training dataset produces a well-calibrated threshold. Likewise, improved bias does not by itself imply improved variance or MSE. We use “practical calibration” for a specified marginal-bias tolerance, not exact finite-sample CFAR.

3. Energy Law and Detector Construction

3.1. Normalized Energy and the Oracle

Proposition 1 
(Normalized Gaussian energy survival). Under the noise model, let Q = E 0 / γ and 0 ≤ η < 1 . Then
S η ( q ) = P ( Q > q ) = 1 π ∫ 0 π exp − q 1 + η cos 2 θ d θ , q ≥ 0 .
Proof. 
Diagonalize Σ = O diag ( λ 1 , λ 2 ) O T with O T O = I 2 . For independent U , V ∼ N ( 0 , 1 ) , write
W 0 = d O ( λ 1 U , λ 2 V ) T .
Orthogonal transformations preserve the Euclidean norm, giving
Q = d 1 + η 2 U 2 + 1 − η 2 V 2 .
Write U = R cos Θ , V = R sin Θ with R ≥ 0 and Θ ∈ [ 0 , 2 π ) . The polar-coordinate Jacobian is r, so
f R , Θ ( r , θ ) = r 2 π e − r 2 / 2 = ( r e − r 2 / 2 ) 1 2 π .
Thus Θ is uniform and independent of R. Moreover, for h ≥ 0 ,
P ( R 2 / 2 > h ) = ∫ 2 h ∞ r e − r 2 / 2 d r = e − h .
Consequently H = R 2 / 2 ∼ Exp ( 1 ) independently of Θ , and substitution yields
Q = H { ( 1 + η ) cos 2 Θ + ( 1 − η ) sin 2 Θ } = H ( 1 + η cos 2 Θ ) .
Since 1 + η cos 2 θ ≥ 1 − η > 0 , conditioning gives
P ( Q > q ∣ Θ = θ ) = exp { − q / ( 1 + η cos 2 θ ) } .
Averaging over Θ gives the integral over [ 0 , 2 π ) with factor 1 / ( 2 π ) . Periodicity of the integrand with period π proves (1).    □
The uniform angle here belongs to the standardized pair ( U , V ) , not generally to the physical phase of the improper observation Z 0 . The survival is continuous and strictly decreasing from one to zero, so its interior quantiles are unique. Let q u ( η ) solve S η ( q u ( η ) ) = u . The oracle threshold τ or = γ q α ( η ) satisfies P Σ ( E 0 > τ or ) = α exactly. At η = 0 , S 0 ( q ) = e − q and q u ( 0 ) = − log u .

3.2. Covariance Plug-In Detector

The plug-in threshold and p-value are
τ plug = γ ^ q α ( η ^ ) , p plug = S η ^ ( E 0 / γ ^ ) .
Reject H 0 when p plug < α , equivalently when E 0 > τ plug . Estimating covariance does not make this p-value exactly uniform at finite K.
For comparison, if properness is known and imposed during fitting, the restricted scale estimate is γ ^ = K − 1 ∑ j = 1 K E j . Then E 0 / γ ^ ∼ F 2 , 2 K , and the exact size- α threshold is
τ proper = K γ ^ α − 1 / K − 1 .
This is the single-test-observation specialization of the classical independent-reference F/CA-CFAR calibration [9]. It is not the unrestricted plug-in procedure studied in the confirmation experiment: there, η ^ is estimated rather than set to zero, including when η = 0 .

3.3. Refitted Parametric-Bootstrap Detector

Conditional on training, generate each independent fitted-model replicate as
W 1 , b * , … , W K , b * , W 0 , b * ∼ N 2 ( 0 , Σ ^ K ) .
Refit covariance using only the bootstrap training observations, and calculate
p b * = S η ^ b * ∥ W 0 , b * ∥ 2 / γ ^ b * .
Refitting is essential: holding the fitted covariance fixed would omit the training-estimation distortion the bootstrap is intended to reproduce. The implemented Monte Carlo p-value is
p MC = 1 + ∑ b = 1 B 1 { p b * ≤ p plug } B + 1 .
Reject when p MC ≤ α . With continuous distributions this is equivalent to p plug < C K , B , where
r B = ⌊ α ( B + 1 ) ⌋ , C K , B = p ( r B ) * , τ K , B = γ ^ q C K , B ( η ^ ) .
For r B = 0 set τ K , B = + ∞ . The Monte Carlo convention alone does not establish exact finite-sample validity in this fitted composite model. The ideal bootstrap replaces the order statistic by the exact lower α -quantile of the fitted-model refitted p-value distribution.
To make the connection with prepivoting explicit, for a fixed positive-definite matrix M define
G K , M ( u ) = P M S η ^ K * ∥ W 0 * ∥ 2 / γ ^ K * ≤ u , 0 ≤ u ≤ 1 ,
where the K training vectors and independent test vector are generated under M, and the starred parameters are refitted using only that training set. The ideal calibrated p-value and decision are
p cal = G K , Σ ^ K ( p plug ) , reject if p cal < α .
Continuity and strict increase of G K , M make this equivalent to the ideal quantile rule above. Thus we bootstrap an approximately pivotal fitted-survival statistic, in the spirit of Beran’s fitted-CDF transformations [5]. Only one explicit simulated bootstrap layer is needed here because the Gaussian energy survival is evaluated by quadrature rather than by an additional nested simulation. The theory below concerns this detector’s calibration and does not invoke generic higher-order refinements.

3.4. Exact Covariance Sampling

If L L T = Σ ^ K , draw mutually independent variables to form
A b = χ K 2 0 G b χ K − 1 2 , G b ∼ N ( 0 , 1 ) , Σ ^ b * = L A b A b T L T K .
Bartlett decomposition gives the same covariance law as explicit bootstrap training vectors [4]. Generate W 0 , b * independently under Σ ^ K , not under the random Σ ^ b * . The detector depends on the bootstrap training set only through its covariance, so this substitution preserves its distribution. Per-covariance sampling work no longer grows with K, although quadrature and original-training work remain.

4. Theoretical Framework

The consistency argument follows the general fitted-model bootstrap logic of [5,6]. We supply direct conditional and uniform arguments for the independent-training energy statistic, rather than invoke the higher-order matched-filter results of [12] for a different model. Common scaling and orthogonal transformation of training and test observations leave plug-in and coupled-bootstrap decisions unchanged. Under W j ↦ s O W j , covariance becomes s 2 O Σ ^ O T and energy becomes s 2 E 0 ; the normalized energy, estimated impropriety and bootstrap p-values are unchanged. Thus marginal calibration depends on ( K , η , α ) , and on B for finite-budget bootstrap, rather than separately on power or orientation.
Theorem 2 
(Pointwise ideal-bootstrap calibration). For each fixed positive-definite Σ and 0 < α < 1 , under the model above and exact energy-law calculations,
A plug , K ( T K ; Σ ) → p α , A boot , K ideal ( T K ; Σ ) → p α .
Consequently marginal false-alarm probabilities tend to α, and calibration bias, variance and MSE tend to zero for both procedures. 
Proof 
(Proof outline). The law of large numbers gives Σ ^ K → Σ ; eigenvalue continuity gives convergence of γ ^ and η ^ . The energy survival function and its interior quantiles are jointly continuous on the positive-definite model, establishing plug-in calibration. For any deterministic sequence of fitted matrices tending to Σ , couple bootstrap covariance as L K H K L K T , with H K = K − 1 ∑ j = 1 K G j G j T → I 2 , and couple the independent test vector as L K G 0 . The refitted p-value then converges to the oracle uniform p-value. Its CDF converges uniformly to the uniform CDF, so its lower α -quantile tends to α . Applying this argument to convergent subsequences of Σ ^ K establishes convergence in probability of the fitted bootstrap cutoff. Threshold continuity then yields the stated conditional result. Since A ∈ [ 0 , 1 ] , convergence in probability implies convergence of the first two moments. The self-contained uniform argument in Appendix C also establishes these pointwise and moment implications.    □
For fixed B with 1 ≤ r B ≤ B , the asymptotic cutoff is an order statistic of B independent uniforms. Therefore
A K , B ⇒ Beta ( r B , B + 1 − r B ) , lim K → ∞ Var ( A K , B ) = r B ( B + 1 − r B ) ( B + 1 ) 2 ( B + 2 ) > 0 .
Its limiting mean is r B / ( B + 1 ) , which equals α for the budgets and levels used here. Thus fixed-budget threshold variability can persist despite zero limiting marginal bias. Growing-budget consistency requires B → ∞ as well as K → ∞ . No universal finite-K bias or MSE dominance is claimed. A self-contained uniform absolute-calibration argument is given in Appendix C. Its bounds also cover sequences approaching singularity within the positive-definite model. They do not establish uniform relative calibration as α → 0 or higher-order bootstrap bias cancellation. Propositions 7 and 8 make marginal-bias convergence and budget stability explicit. The latter separates increasing K at fixed budgets from increasing B at fixed K; neither establishes monotone bias improvement.

5. Independent Confirmation Design

5.1. Grid and Numerical Implementation

Scale/rotation invariance motivates setting γ = 1 and Σ = diag ( ( 1 + η ) / 2 , ( 1 − η ) / 2 ) . The prespecified confirmation grid is
K ∈ { 50 , 100 , 200 } , η ∈ { 0 , 0.5 , 0.9 } , α ∈ { 0.05 , 0.01 } , B ∈ { 1999 , 4999 } .
The numerical implementation uses 256-node Gauss–Legendre quadrature for (1) and bracketed root finding for thresholds. Numerical values are approximations to the exact-law theory. Prior matched 256/512-node checks support agreement on their tested configurations, not a uniform numerical guarantee.
Each outer repetition generates one training dataset and 4999 independent bootstrap replicates. The 1999-budget calculation uses their prefix. Methods, nominal levels and budgets are paired within a training dataset; different training identifiers use independent random streams. Once a threshold is fixed, its conditional false-alarm probability is evaluated as
A = S η ( τ / γ ) ,
eliminating an additional finite test-sample Monte Carlo error. Here K is the training size, B is the bootstrap budget, and R is the number of independent training/calibration experiments. Increasing R improves estimation of procedure-level moments; it does not change the detector deployed on one dataset.

5.2. Precision Planning and Decision Criteria

The design separates the calibration estimand, performance measures and Monte Carlo precision, following established simulation-study principles [18]. All confirmation sample sizes and decision margins were fixed using a separate pilot before examining confirmation outcomes. The fresh pilot used R = 200 per ( K , η ) configuration and seed 2026100941. Its outcomes are excluded from confirmation. For marginal bias, the practical tolerance is δ = 0.05 α and the planned interval half-width is h = δ / 2 . There are 54 bias intervals and 18 paired-budget intervals, forming one Bonferroni family of M = 72 . With pilot standard deviation s, the planning rule is
R = max 1000 , z 1 − 0.05 / ( 2 M ) 1.25 s h 2 .
For each ( K , η ) take the largest requirement across levels, methods and budget differences. The factor 1.25 is a planning safeguard, not a guarantee. The resulting fixed values are shown in Table 1.
Confirmation uses independent seed 2026100942 with the recorded wishart_bartlett_v1 engine. For errors e r = A r − α , compute
b ^ = 1 R ∑ r e r , I b = b ^ ± t R − 1 , 1 − 0.05 / ( 2 M ) s e R .
Practical calibration is supported only if the entire interval is inside [ − δ , δ ] . An interval containing zero is not sufficient. An interval entirely outside the tolerance is evidence of a material deviation; other outcomes are inconclusive. Student-t coverage is approximate for these errors; Bonferroni adjustment does not correct approximation error.
The budget comparison uses d r = A 1999 , r − A 4999 , r and the same interval and tolerance logic. This assesses average calibration sensitivity to budget, not agreement for every dataset or equivalence to infinite bootstrap. The plan is not a power calculation for paired MSE superiority; any MSE comparisons are secondary exploratory analyses. No outcome-dependent stopping or precision target revision is permitted within confirmation.

6. Results

6.1. Exploratory Pilot, Kept Separate from Confirmation

The smaller-grid R = 200 pilot comprised 1800 independent training experiments and 8,998,200 bootstrap replicates, completing in approximately 75 seconds. All 54 calibration intervals were inconclusive. Of 18 paired-budget intervals, 10 were inside the practical tolerance and 8 were inconclusive. At B = 4999 , bootstrap had lower observed absolute bias at 14 of 18 grid points and lower observed MSE at 13 of 18. These are descriptive pilot findings, not confirmatory superiority statements.

6.2. Completion and Precision Audit

The independent confirmation completed all nine configurations with the frozen sample sizes in Table 1, totaling 119,183 training experiments and 715,098 exported method/level/budget rows. These rows are paired outputs, not 715,098 independent experiments. Execution took 3527.08 seconds (58.78 minutes) on the study system; this is a recorded runtime, not a cross-platform computational benchmark. The completion marker, manifest, seed, finite conditional probabilities and raw-export counts were validated; calibration and budget classifications were also reconciled against calculations from the raw data. No pilot observations were pooled into confirmation, and no sample size or tolerance was revised using confirmation outcomes. All 54 bias intervals achieved the planned half-width h = 0.025 α . Precision attainment is distinct from whether an interval meets the calibration tolerance.

6.3. Practical Marginal Calibration

Table 2 reports all prespecified classifications. Every bootstrap interval at both budgets is wholly contained in [ − 0.05 α , 0.05 α ] . Of the 18 plug-in intervals, 5 meet this criterion, 10 lie wholly outside the tolerance, and 3 overlap its boundary and remain inconclusive. The full configuration-level results, expressed relative to the nominal level, appear in Appendix A.
The estimated relative bias 100 b ^ / α ranges from − 2.787 % to 1.932 % for B = 1999 and from − 2.846 % to 1.977 % for B = 4999 . Plug-in relative bias is positive at every tested point, ranging from 1.801 % to 30.436 % . All six plug-in cases at K = 50 lie outside tolerance. At K = 100 , both improper-noise cases at α = 0.01 lie outside; ( η , α ) = ( 0 , 0.05 ) meets tolerance, and the other three are inconclusive. At K = 200 , all α = 0.05 cases and the proper-noise α = 0.01 case meet tolerance, while both improper-noise α = 0.01 cases remain outside.
Tolerance containment is not a test of exact zero bias. For example, at K = 50 , η = 0 , α = 0.01 , the bootstrap B = 4999 estimate is P FA = 0.0097154 , with relative-bias interval [ − 4.479 % , − 1.213 % ] . This interval excludes zero but lies entirely inside the accepted ± 5 % relative tolerance. Conversely, the corresponding plug-in relative-bias interval is [ 8.811 % , 12.294 % ] , wholly outside it. Thus the confirmation establishes practical marginal calibration under the chosen criterion, rather than exact equality to the nominal level.

6.4. Achieved False-Alarm Probabilities

Table 3 reports achieved marginal probabilities, not relative biases. Each interval is obtained by adding the nominal level to the corresponding adjusted bias interval:
P ^ FA = α + b ^ , I P FA = [ α + I b , low , α + I b , high ] .
All values are recomputed from raw confirmation records. Intervals describe uncertainty about the marginal mean, not the distribution of conditional false-alarm probabilities across training datasets.

6.5. Paired Bootstrap-Budget Assessment

All 18 adjusted intervals for E [ A 1999 − A 4999 ] lie inside [ − 0.05 α , 0.05 α ] . Across the grid, the largest absolute estimated mean budget difference is 0.262 % of the nominal level; the largest absolute adjusted interval endpoint is 1.219 % of that level. Complete intervals are reported in Appendix B. These findings indicate no practically material average-calibration change under the prespecified margin when moving from 1999 to 4999 replicates on this grid. They do not establish agreement of individual dataset thresholds, equal variance or MSE, or equivalence to the ideal infinite-budget bootstrap.
Figure 1, Figure 2, Figure 3 and Figure 4 display relative bias, paired budget sensitivity and empirical conditional-error spread. Distribution percentile ranges are not confidence intervals; sizable conditional variability can coexist with acceptable marginal bias.

7. Discussion and Limitations

The primary inferential target is marginal false-alarm calibration under a specified Gaussian training model. A well-calibrated average may coexist with substantial dataset-to-dataset variation. Fixed-B bootstrap randomness is distinct from training error and should not be mistaken for a failure of ideal-bootstrap consistency. Efficient Wishart sampling changes computational cost, not the statistical accuracy associated with K, B, or R.
This marginal objective must be distinguished from tolerance confidence. In our notation, the latter asks for a statement such as
P Σ { A m , B ( T K , U B ; Σ ) ≤ α } ≥ β ,
as motivated by tolerance-based bootstrap matched filters [17]. Containment of a confidence interval for E A − α in a practical margin does not establish that probability statement. A conservative order-statistic choice can control tolerance under a correct simulated reference law, but a fitted-law approximation must still be justified under the true noise model. We do not claim such a finite-sample tolerance guarantee for the present detector.
The use of raw Euclidean energy also defines the scope of the comparison. Whitened, matched-filter and rank-based procedures can address different invariance or detection objectives; exact CFAR for an adaptive matched-filter statistic [10] does not imply exact calibration of the raw-energy plug-in threshold. Our experiment compares two calibrations of the same energy statistic, not all possible Gaussian detectors. In particular, an application- specific power comparison would require a specified signal alternative.
The confirmation supports the refitted bootstrap as a practical marginal calibration procedure on the prespecified grid, where plug-in calibration often remains materially distorted. The absence of a material paired budget effect supports using B = 1999 for this marginal-calibration objective in these tested regimes, but does not make it universally sufficient for other objectives or noise parameters. Interval coverage remains approximate; the consistency theory and the numerical finite-sample findings are complementary, not interchangeable. The single independent confirmation was not a repeated coverage experiment or a separately powered MSE-superiority study.
The confirmation grid excludes K < 50 and includes only three impropriety levels; it cannot establish performance over all covariances or training sizes. The known-zero-mean, independent, identically distributed Gaussian assumptions exclude estimated means, contaminated training, temporal dependence and non-Gaussian noise. Detection power under an alternative hypothesis is not studied here. Uniform relative calibration at vanishing nominal levels and universal finite-sample MSE superiority are not established. Nor do we establish the higher-order refinements studied for other statistics in [5,12]: those require detector-specific expansions and regularity checks, particularly at the proper-noise eigenvalue coincidence.

8. Conclusions

Independent confirmation over the selected training sizes, impropriety levels and nominal levels supports practical marginal false-alarm calibration of the refitted parametric-bootstrap energy detector at both tested budgets. Every bootstrap bias interval meets the prespecified ± 0.05 α tolerance, whereas plug-in has 10 material deviations and 3 inconclusive cases among 18 configurations. All paired budget intervals meet the average-calibration tolerance. Exact Wishart sampling enables this study without removing covariance-estimation uncertainty. The findings are finite-grid empirical evidence: exact finite-sample CFAR, per-dataset calibration and universal MSE superiority do not follow. Future work includes broader noise models, detection-power evaluation and separately designed comparative-risk studies.

Reproducibility

Primary implementation files are cfarcalibrationstudy.py, cfarprecisionstudy.py, and runsmallgridconfirmation.py. The frozen design is stored under smallgridpilotR20020261009/plan/frozenplan.json; the separate confirmation directory records its protocol, seed and sample-size plan. It also contains completion.json, confirmationreport.json, calibrationsummary.csv, budgetsummary.csv, and nine raw configuration exports. Appendix values were reconciled against those raw experiments; displayed relative percentages are rounded to three decimal places and classifications are computed from unrounded values. The recorded runtime environment is Python 3.12.7, NumPy 1.26.4 and SciPy 1.14.1.

Code and data availability

All study data are simulated. The implementation, frozen simulation protocol, experiment-level exports, numerical validation records and file-hash manifests have been assembled in a separate local reproducibility package. A public repository and persistent release identifier have not yet been assigned.

Appendix A. All Confirmation Calibration Intervals

Entries are relative-bias percentages 100 b ^ / α and adjusted intervals 100 I b / α . “Within” means the interval is wholly inside [ − 5 , 5 ] ; “Outside” means wholly outside; all other cases are inconclusive. Bootstrap rows identify the budget B. Every case is included.
Table A1. Complete marginal-calibration confirmation results.
Table A1. Complete marginal-calibration confirmation results.
K η α Method/B Bias (%) Interval (%) Outcome
50 0.0 0.01 1999 -2.787 [-4.476, -1.099] Within
50 0.0 0.01 4999 -2.846 [-4.479, -1.213] Within
50 0.0 0.01 Plug-in 10.552 [8.811, 12.294] Outside
50 0.0 0.05 1999 -0.209 [-1.236, 0.818] Within
50 0.0 0.05 4999 -0.312 [-1.322, 0.697] Within
50 0.0 0.05 Plug-in 6.047 [5.011, 7.084] Outside
50 0.5 0.01 1999 1.932 [-0.147, 4.010] Within
50 0.5 0.01 4999 1.977 [-0.054, 4.008] Within
50 0.5 0.01 Plug-in 25.109 [22.872, 27.346] Outside
50 0.5 0.05 1999 0.595 [-0.568, 1.757] Within
50 0.5 0.05 4999 0.648 [-0.501, 1.797] Within
50 0.5 0.05 Plug-in 9.099 [7.919, 10.279] Outside
50 0.9 0.01 1999 0.852 [-0.697, 2.400] Within
50 0.9 0.01 4999 0.797 [-0.711, 2.305] Within
50 0.9 0.01 Plug-in 30.436 [28.659, 32.212] Outside
50 0.9 0.05 1999 0.390 [-0.487, 1.267] Within
50 0.9 0.05 4999 0.394 [-0.472, 1.261] Within
50 0.9 0.05 Plug-in 11.335 [10.423, 12.247] Outside
100 0.0 0.01 1999 -0.791 [-2.829, 1.247] Within
100 0.0 0.01 4999 -0.662 [-2.594, 1.270] Within
100 0.0 0.01 Plug-in 5.259 [3.331, 7.186] Inconclusive
100 0.0 0.05 1999 0.035 [-1.185, 1.254] Within
100 0.0 0.05 4999 0.062 [-1.129, 1.254] Within
100 0.0 0.05 Plug-in 3.171 [1.981, 4.361] Within
100 0.5 0.01 1999 0.628 [-1.252, 2.508] Within
100 0.5 0.01 4999 0.411 [-1.371, 2.193] Within
100 0.5 0.01 Plug-in 12.455 [10.608, 14.303] Outside
100 0.5 0.05 1999 0.118 [-0.948, 1.184] Within
100 0.5 0.05 4999 0.117 [-0.923, 1.157] Within
100 0.5 0.05 Plug-in 4.476 [3.435, 5.516] Inconclusive
100 0.9 0.01 1999 -0.165 [-2.208, 1.878] Within
100 0.9 0.01 4999 0.052 [-1.918, 2.021] Within
100 0.9 0.01 Plug-in 14.317 [12.226, 16.408] Outside
100 0.9 0.05 1999 0.095 [-1.078, 1.268] Within
100 0.9 0.05 4999 0.143 [-1.009, 1.295] Within
100 0.9 0.05 Plug-in 5.458 [4.286, 6.630] Inconclusive
200 0.0 0.01 1999 -0.062 [-2.126, 2.002] Within
200 0.0 0.01 4999 0.200 [-1.656, 2.056] Within
200 0.0 0.01 Plug-in 2.904 [1.173, 4.634] Within
200 0.0 0.05 1999 0.189 [-1.005, 1.382] Within
200 0.0 0.05 4999 0.274 [-0.860, 1.407] Within
200 0.0 0.05 Plug-in 1.801 [0.705, 2.897] Within
200 0.5 0.01 1999 1.034 [-1.122, 3.191] Within
200 0.5 0.01 4999 1.173 [-0.808, 3.155] Within
200 0.5 0.01 Plug-in 7.224 [5.298, 9.149] Outside
200 0.5 0.05 1999 0.439 [-0.757, 1.635] Within
200 0.5 0.05 4999 0.544 [-0.602, 1.690] Within
200 0.5 0.05 Plug-in 2.851 [1.728, 3.973] Within
200 0.9 0.01 1999 -0.146 [-2.051, 1.760] Within
200 0.9 0.01 4999 0.104 [-1.651, 1.858] Within
200 0.9 0.01 Plug-in 7.151 [5.417, 8.886] Outside
200 0.9 0.05 1999 -0.070 [-1.148, 1.008] Within
200 0.9 0.05 4999 -0.023 [-1.054, 1.009] Within
200 0.9 0.05 Plug-in 2.720 [1.704, 3.736] Within

Appendix B. All Paired Budget Intervals

Entries give 100 D ^ / α and adjusted intervals for D = E [ A 1999 − A 4999 ] , in percentages of the nominal level. Every interval is inside [ − 5 , 5 ] ; classifications use unrounded values.
Table A2. Complete paired-budget confirmation results.
Table A2. Complete paired-budget confirmation results.
K η α Difference (%) Interval (%)
50 0.0 0.01 0.059 [-0.410, 0.527]
50 0.0 0.05 0.103 [-0.082, 0.289]
50 0.5 0.01 -0.045 [-0.566, 0.475]
50 0.5 0.05 -0.053 [-0.253, 0.146]
50 0.9 0.01 0.054 [-0.333, 0.442]
50 0.9 0.05 -0.005 [-0.151, 0.142]
100 0.0 0.01 -0.129 [-0.857, 0.599]
100 0.0 0.05 -0.028 [-0.327, 0.271]
100 0.5 0.01 0.218 [-0.404, 0.840]
100 0.5 0.05 0.001 [-0.251, 0.252]
100 0.9 0.01 -0.217 [-0.886, 0.453]
100 0.9 0.05 -0.048 [-0.325, 0.229]
200 0.0 0.01 -0.262 [-1.219, 0.695]
200 0.0 0.05 -0.085 [-0.481, 0.311]
200 0.5 0.01 -0.139 [-1.035, 0.757]
200 0.5 0.05 -0.105 [-0.479, 0.270]
200 0.9 0.01 -0.249 [-1.050, 0.551]
200 0.9 0.05 -0.047 [-0.381, 0.287]

Appendix C. Uniform Absolute Calibration: Complete Argument

This appendix uses exact survival functions and ideal bootstrap. For M > 0 , write S M ( t ) = P ( V T M V > t ) with V ∼ N 2 ( 0 , I 2 ) ; this is the unnormalized energy survival, not a new parameterization of S η . For 0 < δ < 1 define
ρ K ( δ ) = 6 K δ 2 , ω ( δ ) = − log ( 1 − δ ) e .
Proposition 3 
(Relative covariance concentration). For every Σ > 0 , with probability at least 1 − ρ K ( δ ) ,
( 1 − δ ) Σ ⪯ Σ ^ K ⪯ ( 1 + δ ) Σ .
Proof. 
Let Q K = K − 1 ∑ i = 1 K V i V i T for independent standard Gaussian two-vectors. The diagonal entries have variance 2 / K , and each off-diagonal entry has variance 1 / K , so E ∥ Q K − I 2 ∥ F 2 = 6 / K . Markov’s inequality and ∥ · ∥ op ≤ ∥ · ∥ F give P ( ∥ Q K − I 2 ∥ op > δ ) ≤ ρ K ( δ ) . Use Σ ^ K = d Σ 1 / 2 Q K Σ 1 / 2 and congruence of ( 1 − δ ) I 2 ⪯ Q K ⪯ ( 1 + δ ) I 2 . This good-event probability is independent of Σ . A bound above one is uninformative but remains valid. □
Proposition 4 
(Uniform survival stability). If ( 1 − δ ) M ⪯ M ^ ⪯ ( 1 + δ ) M , then
sup t ≥ 0 | S M ^ ( t ) − S M ( t ) | ≤ ω ( δ ) .
Proof. 
Put v θ = ( cos θ , sin θ ) T and d M ( θ ) = 2 v θ T M v θ > 0 . Gaussian polar coordinates give S M ( t ) = ( 2 π ) − 1 ∫ 0 2 π e − t / d M ( θ ) d θ . Differentiation at t > 0 gives
t f M ( t ) = 1 2 π ∫ 0 2 π t d M ( θ ) e − t / d M ( θ ) d θ ≤ 1 e .
Integrating along u ↦ S M ( t e u ) yields | S M ( a t ) − S M ( t ) | ≤ | log a | / e for a > 0 . The Loewner inequalities, applied to the same V, give
S M ( t / ( 1 − δ ) ) ≤ S M ^ ( t ) ≤ S M ( t / ( 1 + δ ) ) .
Use log ( 1 + δ ) ≤ − log ( 1 − δ ) to obtain the result. At t = 0 both survivals equal one. □
Proposition 5 
(Refitted p-value CDF bound). Let G K , M be the CDF of the refitted plug-in p-value in an independent Gaussian training/test experiment under M > 0 . Then
sup M > 0 sup 0 ≤ u ≤ 1 | G K , M ( u ) − u | ≤ ω ( δ ) + ρ K ( δ ) .
Proof. 
Couple p * = S M ^ K * ( E 0 * ) with the oracle U * = S M ( E 0 * ) ∼ Unif ( 0 , 1 ) . On the relative covariance good event, | p * − U * | ≤ ω ( δ ) . Its complement has probability at most ρ K ( δ ) . Thus
P ( U * ≤ u − ω ) − ρ K ≤ G K , M ( u ) ≤ P ( U * ≤ u + ω ) + ρ K .
The uniform CDF, extended by zero and one outside [ 0 , 1 ] , is one-Lipschitz. No independence between the good event and U * is needed. The bound is independent of M. □
Theorem 6 
(Uniform ideal-bootstrap absolute calibration). Let A K = A boot , K ideal ( T K ; Σ , α ) . For every 0 < δ < 1 ,
sup Σ > 0 sup 0 < α < 1 P Σ { | A K − α | > 2 ω ( δ ) + ρ K ( δ ) } ≤ ρ K ( δ ) .
Consequently, for every ϵ > 0 ,
sup Σ > 0 sup 0 < α < 1 P Σ ( | A K − α | > ϵ ) ⟶ 0 .
Proof. 
The fitted-model CDF G K , Σ ^ K is continuous and strictly increasing on ( 0 , 1 ) : conditional on each positive-definite refitted covariance, the independent test energy has a positive continuous density and its fitted survival is continuous and strictly decreasing. Mixture preserves continuity and strict increase. Its ideal cutoff c K = G K , Σ ^ K − 1 ( α ) therefore satisfies G K , Σ ^ K ( c K ) = α . Equation (A1), valid for every fitted covariance, gives | c K − α | ≤ ω ( δ ) + ρ K ( δ ) .
For the actual test observation set p K = S Σ ^ K ( E 0 ) and U = S Σ ( E 0 ) . Conditional on training, U is uniform by independence. On the actual relative covariance good event, | p K − U | ≤ ω ( δ ) for every test energy. Hence the conditional CDF of p K differs from the uniform CDF by at most ω ( δ ) . Rejection is p K < c K , with equality of probability zero; therefore | A K − c K | ≤ ω ( δ ) and | A K − α | ≤ 2 ω ( δ ) + ρ K ( δ ) on that event. Its complement proves the probability bound. For any ϵ > 0 , first choose a fixed δ with 2 ω ( δ ) < ϵ / 2 , then take K large enough that ρ K ( δ ) < ϵ / 2 . The bound tends to zero. □
The plug-in cutoff is α , so the same actual good event gives | A plug , K − α | ≤ ω ( δ ) and uniform absolute consistency. For either ideal procedure, | A K − α | ≤ 1 implies
sup Σ , α E ( A K − α ) 2 ≤ ϵ 2 + sup Σ , α P ( | A K − α | > ϵ ) .
Let K → ∞ , then ϵ ↓ 0 , to obtain uniform MSE convergence. Cauchy–Schwarz controls bias and variance is bounded by MSE. This completes the pointwise moment implications as well. These conservative bounds do not prove higher-order bias cancellation, uniform relative calibration at vanishing levels, or universal finite-K superiority. Singular covariances and numerical implementation errors are excluded. Fixed-budget results are distinct.

Appendix C.1. Marginal Bias Convergence

Proposition 7 
(Ideal and finite-budget bootstrap bias). Under the assumptions of this appendix, define b K ideal = E A K ideal − α and b K , B = E A K , B − α , where the latter expectation includes calibration randomness. For every 0 < δ < 1 ,
sup Σ > 0 , 0 < α < 1 | b K ideal | ≤ 2 ω ( δ ) + 2 ρ K ( δ ) .
For r B = ⌊ α ( B + 1 ) ⌋ with 1 ≤ r B ≤ B ,
b K , B − r B B + 1 − α ≤ 2 ω ( δ ) + 2 ρ K ( δ ) .
Thus ideal-bootstrap marginal bias tends uniformly to zero. For fixed B and α, finite-budget bias tends to r B / ( B + 1 ) − α , uniformly in Σ > 0 . 
Proof. 
Let G T = G K , Σ ^ K and ε K = ω ( δ ) + ρ K ( δ ) . By (A1), sup u | G T ( u ) − u | ≤ ε K for every fitted covariance. The ideal cutoff C = G T − 1 ( α ) satisfies | C − α | ≤ ε K . For finite B, probability integral transforms V b = G T ( p b * ) are independent uniforms conditional on training. Strict increase of G T gives G T ( C ) = V ( r B ) for C = p ( r B ) * ; hence
| C − V ( r B ) | ≤ ε K , E V ( r B ) = r B B + 1 .
On the actual relative covariance good event, the conditional CDF of the actual plug-in p-value is within ω ( δ ) of uniform at every cutoff. The test observation is independent of bootstrap calibration given training, so | A − C | ≤ ω ( δ ) also conditional on calibration draws. Therefore on that event
| A K ideal − α | ≤ 2 ω + ρ K , | A K , B − V ( r B ) | ≤ 2 ω + ρ K .
Each absolute difference is at most one on the complement, whose probability is at most ρ K . Taking expectations and using | E X | ≤ E | X | proves both displayed bias bounds. First choose a fixed small δ and then take K large; ω ( δ ) → 0 as δ ↓ 0 and ρ K ( δ ) → 0 as K → ∞ . The bounds do not depend on Σ . □
The selected budgets and levels have integer α ( B + 1 ) , so r B / ( B + 1 ) = α and b K , B → 0 even at fixed B. This is convergence of marginal bias, not of individual conditional errors: the fixed-budget variance limit stated in the main text remains positive. No finite-K dominance or higher-order bias cancellation follows.

Appendix C.2. Budget Stability of Marginal Bias

Proposition 8 
(Two budget limits). For fixed B 1 , B 2 and α, let r j = ⌊ α ( B j + 1 ) ⌋ satisfy 1 ≤ r j ≤ B j and set d j = r j / ( B j + 1 ) − α . Then
sup Σ > 0 | b K , B 1 − b K , B 2 − ( d 1 − d 2 ) | ≤ 4 ω ( δ ) + 4 ρ K ( δ ) , 0 < δ < 1 .
In particular, b K , B 1 − b K , B 2 → d 1 − d 2 uniformly over Σ > 0 as K → ∞ . Separately, for each fixed K ≥ 2 , Σ > 0 and 0 < α < 1 ,
b K , B ( Σ , α ) ⟶ b K ideal ( Σ , α ) as B → ∞ .
Proof. 
Proposition 7 gives | b K , B j − d j | ≤ 2 ω + 2 ρ K . The triangle inequality gives the first bound; choosing small δ , then large K, proves its limit.
For the second claim, conditional on original training T K , couple all budgets using one infinite independent sequence of fitted-model bootstrap replicates with continuous strictly increasing CDF G T . Put c T = G T − 1 ( α ) . Its empirical CDF converges almost surely at any fixed argument conditional on T K , while
⌊ α ( B + 1 ) ⌋ B ⟶ α .
For sufficiently small ϵ > 0 , G T ( c T − ϵ ) < α < G T ( c T + ϵ ) . Empirical CDF convergence therefore brackets the order-statistic cutoff between these two arguments for all sufficiently large B. Taking a countable sequence ϵ ↓ 0 proves C K , B → c T almost surely conditional on training. Define the actual conditional CDF F T ( u ) = P Σ ( p plug < u ∣ T K ) , which is continuous. Independence of test and calibration gives
A K , B = F T ( C K , B ) ⟶ F T ( c T ) = A K ideal .
Since all these probabilities are in [ 0 , 1 ] , bounded convergence first over calibration and then over training yields convergence of expectations. Subtracting α gives the claimed bias limit. □
For B 1 = 1999 , B 2 = 4999 and α ∈ { 0.05 , 0.01 } , d 1 = d 2 = 0 , so their marginal-bias difference tends to zero as K increases. At fixed K, increasing budget approaches ideal-bootstrap bias, which need not be zero. These results imply neither monotone improvement with B nor equal variances, MSEs or individual thresholds. The finite-grid tolerance conclusion comes from the independent paired intervals, not from this asymptotic proof alone. If a budget has r B = 0 , it never rejects and its bias is − α ; such budgets are excluded from the fixed-budget statements.

References

  1. Schreier, P.J.; Scharf, L.L. Statistical Signal Processing of Complex-Valued Data: The Theory of Improper and Noncircular Signals; Cambridge University Press, 2010. [Google Scholar] [CrossRef]
  2. Schreier, P.J.; Scharf, L.L. Second-order analysis of improper complex random vectors and processes. IEEE Trans. Signal Process. 2003, 51, 714–725. [Google Scholar] [CrossRef]
  3. Wishart, J. The Generalised Product Moment Distribution in Samples from a Normal Multivariate Population. Biometrika 1928, 20A, 32–52. [Google Scholar] [CrossRef]
  4. Bartlett, M.S. On the Theory of Statistical Regression. Proc. R. Soc. Edinb. 1934, 53, 260–283. [Google Scholar] [CrossRef]
  5. Beran, R. Prepivoting Test Statistics: A Bootstrap View of Asymptotic Refinements. J. Am. Stat. Assoc. 1988, 83, 687–697. [Google Scholar] [CrossRef]
  6. Dufour, J.M. Monte Carlo tests with nuisance parameters: A general approach to finite-sample inference and nonstandard asymptotics. J. Econom. 2006, 133, 443–477. [Google Scholar] [CrossRef]
  7. Hoyt, R.S. Probability Functions for the Modulus and Angle of the Normal Complex Variate. Bell Syst. Tech. J. 1947, 26, 318–359. [Google Scholar] [CrossRef]
  8. Tugnait, J.K. On Multisensor Detection of Improper Signals. IEEE Trans. Signal Process. 2019, 67, 870–884. [Google Scholar] [CrossRef]
  9. Mariani, A.; Giorgetti, A.; Chiani, M. Effects of Noise Power Estimation on Energy Detection for Cognitive Radio Applications. IEEE Trans. Commun. 2011, 59, 3410–3420. [Google Scholar] [CrossRef]
  10. Robey, F.C.; Fuhrmann, D.R.; Kelly, E.J.; Nitzberg, R. A CFAR Adaptive Matched Filter Detector. IEEE Trans. Aerosp. Electron. Syst. 1992, 28, 208–216. [Google Scholar] [CrossRef]
  11. Besson, O. Impact of covariance mismatched training samples on constant false alarm rate detectors. arXiv Author preprint. 2020, arXiv:2012.01182. [Google Scholar]
  12. Ong, H.T.; Zoubir, A.M. The Bootstrapped Matched Filter and Its Accuracy. IEEE Signal Process. Lett. 2000, 7, 11–13. [Google Scholar] [CrossRef]
  13. Ong, H.T.; Zoubir, A.M. Bootstrap-Based Detection of Signals With Unknown Parameters in Unspecified Correlated Interference. IEEE Trans. Signal Process. 2003, 51, 135–141. [Google Scholar] [CrossRef]
  14. Wang, Jing.; Jin, Yong. Bootstrap-based parametric adaptive matched filter detector: CFAR performance analysis. In Proceedings of the 2015 IEEE International Conference on Signal Processing, Communications and Computing (ICSPCC), 2015. [Google Scholar] [CrossRef]
  15. Huang, Q. Robust Spectrum Sensing Techniques for Cognitive Radio Networks. PhD thesis, Repository date June 2016; thesis title page dated October 2015. University of Edinburgh, 2016. [Google Scholar]
  16. Genest, C.; Rémillard, B. Validity of the parametric bootstrap for goodness-of-fit testing in semiparametric models. Ann. De l’Institut Henri Poincaré Probab. Et. Stat. 2008, 44, 1096–1127. [Google Scholar] [CrossRef]
  17. Zoubir, A.M.; Brcich, R.F. Tolerance Intervals for Accuracy Control of Bootstrapped Matched Filters. IEEE Signal Process. Lett. 2002, 9, 247–250. [Google Scholar] [CrossRef]
  18. Morris, T.P.; White, I.R.; Crowther, M.J. Using simulation studies to evaluate statistical methods. Stat. Med. 2019, 38, 2074–2102. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Relative marginal calibration bias at α = 0.05 . Points show estimates and bars show the prespecified adjusted confidence intervals. The shaded band marks ± 5 % of the nominal level. Panels distinguish impropriety levels; markers distinguish methods and budgets.
Figure 1. Relative marginal calibration bias at α = 0.05 . Points show estimates and bars show the prespecified adjusted confidence intervals. The shaded band marks ± 5 % of the nominal level. Panels distinguish impropriety levels; markers distinguish methods and budgets.
Preprints 238888 g001
Figure 2. Relative marginal calibration bias at α = 0.01 . Intervals and tolerance are defined as in Figure 1. Practical calibration requires containment of the complete interval in the tolerance band, not merely containment of its point estimate.
Figure 2. Relative marginal calibration bias at α = 0.01 . Intervals and tolerance are defined as in Figure 1. Practical calibration requires containment of the complete interval in the tolerance band, not merely containment of its point estimate.
Preprints 238888 g002
Figure 3. Paired B = 1999 minus B = 4999 differences in marginal calibration, expressed as percentages of the nominal level. Left and right panels use α = 0.05 and 0.01 , respectively. Bars are adjusted confidence intervals; shading marks the ± 5 % practical margin.
Figure 3. Paired B = 1999 minus B = 4999 differences in marginal calibration, expressed as percentages of the nominal level. Left and right panels use α = 0.05 and 0.01 , respectively. Bars are adjusted confidence intervals; shading marks the ± 5 % practical margin.
Preprints 238888 g003
Figure 4. Distributions of conditional calibration errors across independent training/calibration experiments. Boxes show the empirical interquartile range and median; whiskers mark the 5th and 95th percentiles. Outlying observations are hidden in the display, not removed from analysis. Rows distinguish nominal levels and columns distinguish impropriety. The shaded band is ± 5 % of the nominal level. Distribution ranges are not confidence intervals for marginal means.
Figure 4. Distributions of conditional calibration errors across independent training/calibration experiments. Boxes show the empirical interquartile range and median; whiskers mark the 5th and 95th percentiles. Outlying observations are hidden in the display, not removed from analysis. Rows distinguish nominal levels and columns distinguish impropriety. The shaded band is ± 5 % of the nominal level. Distribution ranges are not confidence intervals for marginal means.
Preprints 238888 g004
Table 1. Frozen independent confirmation sample sizes per ( K , η ) . Each row covers both nominal levels and all compared methods/budgets.
Table 1. Frozen independent confirmation sample sizes per ( K , η ) . Each row covers both nominal levels and all compared methods/budgets.
K η R
50 0.0 21602
50 0.5 18611
50 0.9 34783
100 0.0 7839
100 0.5 11374
100 0.9 9408
200 0.0 4470
200 0.5 4884
200 0.9 6212
Total 119183
Table 2. Independent confirmation outcomes for marginal calibration bias. Intervals use the prespecified approximate Bonferroni-adjusted procedure.
Table 2. Independent confirmation outcomes for marginal calibration bias. Intervals use the prespecified approximate Bonferroni-adjusted procedure.
Procedure Within tolerance Outside tolerance Inconclusive
Plug-in 5 10 3
Bootstrap, B = 1999 18 0 0
Bootstrap, B = 4999 18 0 0
Table 3. Achieved marginal P FA and adjusted intervals. Each cell gives the estimate followed by its interval. Values are rounded to six decimal places; classifications use unrounded calculations.
Table 3. Achieved marginal P FA and adjusted intervals. Each cell gives the estimate followed by its interval. Values are rounded to six decimal places; classifications use unrounded calculations.
K η α Plug-in Bootstrap 1999 Bootstrap 4999
50 0.0 0.01 0.011055[0.010881, 0.011229] 0.009721[0.009552, 0.009890] 0.009715[0.009552, 0.009879]
50 0.0 0.05 0.053024[0.052505, 0.053542] 0.049896[0.049382, 0.050409] 0.049844[0.049339, 0.050349]
50 0.5 0.01 0.012511[0.012287, 0.012735] 0.010193[0.009985, 0.010401] 0.010198[0.009995, 0.010401]
50 0.5 0.05 0.054550[0.053960, 0.055140] 0.050297[0.049716, 0.050879] 0.050324[0.049750, 0.050899]
50 0.9 0.01 0.013044[0.012866, 0.013221] 0.010085[0.009930, 0.010240] 0.010080[0.009929, 0.010231]
50 0.9 0.05 0.055667[0.055211, 0.056124] 0.050195[0.049756, 0.050633] 0.050197[0.049764, 0.050630]
100 0.0 0.01 0.010526[0.010333, 0.010719] 0.009921[0.009717, 0.010125] 0.009934[0.009741, 0.010127]
100 0.0 0.05 0.051585[0.050991, 0.052180] 0.050017[0.049408, 0.050627] 0.050031[0.049435, 0.050627]
100 0.5 0.01 0.011246[0.011061, 0.011430] 0.010063[0.009875, 0.010251] 0.010041[0.009863, 0.010219]
100 0.5 0.05 0.052238[0.051718, 0.052758] 0.050059[0.049526, 0.050592] 0.050059[0.049539, 0.050579]
100 0.9 0.01 0.011432[0.011223, 0.011641] 0.009983[0.009779, 0.010188] 0.010005[0.009808, 0.010202]
100 0.9 0.05 0.052729[0.052143, 0.053315] 0.050048[0.049461, 0.050634] 0.050072[0.049495, 0.050648]
200 0.0 0.01 0.010290[0.010117, 0.010463] 0.009994[0.009787, 0.010200] 0.010020[0.009834, 0.010206]
200 0.0 0.05 0.050900[0.050352, 0.051448] 0.050094[0.049497, 0.050691] 0.050137[0.049570, 0.050704]
200 0.5 0.01 0.010722[0.010530, 0.010915] 0.010103[0.009888, 0.010319] 0.010117[0.009919, 0.010316]
200 0.5 0.05 0.051425[0.050864, 0.051986] 0.050220[0.049622, 0.050818] 0.050272[0.049699, 0.050845]
200 0.9 0.01 0.010715[0.010542, 0.010889] 0.009985[0.009795, 0.010176] 0.010010[0.009835, 0.010186]
200 0.9 0.05 0.051360[0.050852, 0.051868] 0.049965[0.049426, 0.050504] 0.049989[0.049473, 0.050504]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.