Abstract
Purpose: To evaluate the effectiveness of prismatic image relocation for visual rehabilitation in patients with macular disease and central vision loss, focusing on visual acuity, reading-related outcomes, preferred retinal locus (PRL) behaviour, fixation, and functional outcomes. Methods: A systematic review and meta-analysis was conducted according to PRISMA 2020 and prospectively registered in PROSPERO (CRD420261500738). Scopus, Web of Science Core Collection, PubMed/MEDLINE, and CENTRAL were searched from inception to September 2026. Randomized, non-randomized comparative, pre-post, and case-series studies evaluating prism-based image relocation were eligible. Risk of bias was assessed using RoB 2, ROBINS-I, or the appropriate Joanna Briggs Institute tools. Random-effects meta-analysis was performed when studies were sufficiently comparable. Results: Eleven studies met the inclusion criteria. Two randomized controlled trials provided comparable data for the primary meta-analysis of distance visual acuity. The pooled point estimate was in the direction of better visual acuity with prism correction but was imprecise and included the null effect (MD, −0.218 logMAR; 95% CI, −0.522 to 0.086), with substantial heterogeneity (I² = 94.5%). The certainty of evidence for the primary outcome was rated as very low. Sensitivity analyses did not materially strengthen the evidence. Observational studies frequently reported favourable visual or functional outcomes, but several were affected by important risks of selection bias, confounding, or absence of appropriate control groups. Conclusions: The available evidence indicates that prismatic image relocation can modify retinal image position and may provide visual or functional benefit in selected patients with central vision loss, although the certainty of evidence regarding its effect on distance visual acuity is very low.
Keywords:
macular degeneration
; prism spectacles
; image relocation
; preferred retinal locus
; low vision rehabilitation
; visual acuity
; meta-analysis
1. Introduction
Macular diseases are a major cause of central vision loss and can substantially impair visual acuity, reading performance, face recognition, and other visually demanding activities. When foveal function becomes severely compromised, many patients develop an eccentric retinal area for fixation, commonly referred to as the preferred retinal locus (PRL). The PRL acts as an alternative fixation locus and may partially compensate for the loss of foveal function, although its location, stability, and functional efficiency vary considerably among individuals [1,2,3].
The naturally adopted PRL does not necessarily correspond to the retinal area with the highest residual visual acuity or sensitivity. Instead, its development may be influenced by factors such as proximity to the former fovea, lesion configuration, fixation behavior, binocular viewing conditions, and disease progression [4,5,6,7]. Consequently, the spontaneous PRL may not always provide the most efficient use of the remaining retinal function. This observation has led to the development of rehabilitation strategies aimed at improving eccentric viewing or directing visual information toward more functional retinal areas [8,9,10].
Prismatic image relocation represents one such approach. By optically displacing the image away from the central scotoma and toward functioning eccentric retina, prisms may facilitate the use of an existing PRL or, potentially, promote fixation at a more advantageous retinal locus. Different approaches have been described, including yoked prisms, unilateral or bilateral prismatic corrections, and Fresnel prisms, with considerable variation in prism power, base orientation, and methods used to identify the target retinal area [11,12,13,14,15]. The concept is also closely related to potential visual acuity, since prismatic correction may theoretically allow patients to approach the level of visual performance available at the most functional residual retinal locus [11,16].
Despite this physiological and optical rationale, the clinical evidence remains inconsistent. Some observational studies and controlled trials have reported improvements in distance or near visual acuity, reading performance, fixation behavior, or vision-related quality of life following prismatic correction [11,12,13,14]. In contrast, other investigations, including controlled studies, have failed to demonstrate a clear advantage over conventional spectacles or placebo correction [17,18]. Moreover, changes in visual function do not necessarily imply a stable relocation of the PRL, and microperimetric studies have suggested that prism-induced changes in fixation location may be small, variable, or unpredictable [18,19].
Previous reviews have addressed low-vision rehabilitation, eccentric viewing, or the use of prisms in macular disease, but the available evidence remains heterogeneous with respect to study design, prism prescription, underlying macular disorder, outcome definition, and follow-up [19,20,21]. A comprehensive synthesis specifically focused on prismatic image relocation is therefore needed to determine whether this intervention produces measurable visual or functional benefits and to clarify its relationship with PRL behavior.
The aim of this systematic review and meta-analysis was to evaluate the effectiveness of prismatic image relocation for visual rehabilitation in patients with macular disease and central vision loss, with particular emphasis on visual acuity, reading-related outcomes, fixation characteristics, preferred retinal locus behavior, and patient-reported functional outcomes.
2. Materials and Methods
2.1. Study Design and Protocol
A systematic review and meta-analysis was conducted to evaluate the effectiveness of prismatic image relocation as a visual rehabilitation strategy in patients with macular disease and central vision loss. The review was designed and conducted in accordance with the PRISMA 2020 recommendations.
The review protocol was prospectively registered in PROSPERO (CRD420261500738; registered on 9 September 2026) before study screening and defined the population of interest, eligible interventions, outcomes, and planned methods of synthesis. The target population comprised patients with macular disease associated with central scotoma, eccentric fixation, or use of a preferred retinal locus (PRL), with no age restrictions.
Reporting of this systematic review and meta-analysis was guided by the PRISMA 2020 statement. The completed PRISMA 2020 checklist is provided in Supplementary File S6.
2.2. Information Sources and Search Strategy
A systematic literature search was conducted from database inception to September 2026, with no restrictions on publication date or language. The following electronic databases were searched: Scopus, Web of Science Core Collection, PubMed/MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL). Reference lists of eligible studies and relevant reviews were also examined to identify additional potentially eligible reports.
The search strategy combined terms related to prismatic intervention with terms describing macular disease, central vision loss, eccentric viewing, and the preferred retinal locus. The core search structure was:
(“prism*” OR “prismatic correction” OR “prism spectacle*” OR “yoked prism*” OR “Fresnel prism*” OR “image relocation” OR “relocating prism*”)
AND
(“macular degeneration” OR “age-related macular degeneration” OR AMD OR “macular disease*” OR maculopath* OR “macular dystroph*” OR Stargardt OR “central scotoma*” OR “central vision loss” OR “preferred retinal locus” OR PRL OR “eccentric fixation” OR “eccentric viewing”)
The syntax was adapted to the requirements of each database. In Scopus, searches were conducted using TITLE-ABS-KEY fields, whereas topic searches (TS) were used in Web of Science Core Collection. Equivalent combinations of free-text terms and available indexed terms were used in PubMed/MEDLINE and CENTRAL.
The searches initially retrieved 705 records from Scopus, 224 from Web of Science, 190 from PubMed, and 48 records exported from Cochrane. Records were merged into a single master database and deduplicated hierarchically using DOI, PMID, database-specific identifiers, and, when these were unavailable, combinations of title, authors, publication year, and source.
Reference lists of eligible studies and relevant reviews were examined, and forward citation searching of the included studies was performed using Web of Science and/or Scopus to identify additional potentially eligible reports.
2.3. Eligibility Criteria
Studies were considered eligible if they included patients with age-related macular degeneration, myopic maculopathy, macular dystrophies, Stargardt disease, or other macular disorders associated with central vision loss, central scotoma, eccentric fixation, or use of a PRL. Studies involving mixed populations were eligible only when data for patients with macular disease could be identified separately.
Eligible interventions included optical image relocation using prisms, such as yoked prisms, prismatic spectacles, unilateral or bilateral prismatic corrections, and Fresnel prisms, provided that the purpose of the intervention was to redirect the retinal image toward a functional retinal area, PRL, or eccentric fixation locus. Combined low-vision interventions were considered only when the prismatic component was clearly defined or its contribution could be evaluated separately.
Randomized controlled trials, non-randomized controlled studies, prospective or retrospective cohort studies, pre-post studies without a control group, and case series providing relevant quantitative data were eligible. Single case reports, narrative reviews, systematic reviews, meta-analyses, editorials, letters, theoretical optical studies, and reports without original clinical data were excluded.
Studies in which prisms were used exclusively for strabismus, diplopia, hemianopia, neurological visual field defects, diagnostic purposes, or peripheral field expansion without a macular rehabilitation objective were also excluded.
No mandatory comparator was required. Eligible comparators included placebo or sham spectacles, spectacles without prism, conventional low-vision rehabilitation, alternative rehabilitation strategies, or no intervention.
2.4. Study Selection
All retrieved records were merged into a single database before screening. After removal of duplicates, 782 unique records remained.
Title and abstract screening was performed independently by two reviewers. Each record was classified as Include, Exclude, or Uncertain. Disagreements and uncertain records were subsequently reassessed, and unresolved cases were adjudicated by a third reviewer.
Reports judged potentially eligible after title and abstract screening were assessed at full-text level whenever the full report could be retrieved. Reasons for exclusion at this stage were documented individually. When a full-text report could not be retrieved, other available reports of the same study, including sufficiently detailed indexed abstracts or trial records, were evaluated. Studies were retained only when these sources provided enough information to establish eligibility and, where applicable, extract the prespecified outcome data. Studies with insufficiently reported eligibility or outcome information were not included in quantitative synthesis. No study included in the primary meta-analysis relied exclusively on abstract-level data.
Trial registry entries and multiple reports corresponding to the same underlying study were linked and were not treated as independent studies.
The overall study identification and selection process is summarized in Figure 1.
Records were deduplicated across databases using DOI, PMID, title, authors, and publication year. When full-text reports could not be retrieved, sufficiently detailed abstracts were used only when they provided enough information to establish eligibility and, where applicable, extract prespecified outcome data. One trial registry entry corresponded to a published article and was not treated as an independent study
2.5. Data Extraction
Data were extracted using a standardized form developed specifically for this review. Data extraction was performed independently by two reviewers. Disagreements were resolved by consensus and, when necessary, by consultation with a third reviewer. For each study, the following information was recorded: authors, publication year, study design, population characteristics, sample size, number of participants per group, macular diagnosis, characteristics of the prismatic intervention, prism power and orientation when reported, method used to identify the PRL or eccentric fixation locus, comparator, duration of follow-up, and outcomes assessed.
For quantitative outcomes, sample sizes, event counts, means, standard deviations, baseline and post-intervention values, pre-post changes, and available measures of precision were extracted whenever reported.
Data were preferentially extracted from the full-text article. When only a sufficiently detailed abstract was available, extraction was restricted to information explicitly reported in the abstract, without imputing unpublished values.
Potential overlap between study populations was also assessed by comparing authorship, study setting, recruitment period, sample characteristics, and intervention details. Studies suspected of including overlapping participants were not considered statistically independent unless cohort independence could be established.
2.6. Risk of Bias Assessment
Risk of bias was independently assessed by two reviewers using design-specific validated tools. Disagreements were resolved by consensus or, when necessary, by consultation with a third reviewer. Randomized controlled trials were evaluated using the Cochrane Risk of Bias 2 (RoB 2) tool, considering bias arising from the randomization process, deviations from intended interventions, missing outcome data, outcome measurement, and selection of the reported result. Non-randomized comparative intervention studies were assessed using ROBINS-I, covering bias due to confounding, participant selection, intervention classification, deviations from intended interventions, missing data, outcome measurement, and selection of the reported result.
For uncontrolled observational, pre-post, and case-series designs, the corresponding Joanna Briggs Institute (JBI) critical appraisal checklists were used. Risk-of-bias judgments were based on the information available in the full-text report whenever possible. When only an abstract was available, the assessment was considered provisional because relevant methodological information, including allocation procedures, masking, attrition, and selective reporting, could not always be verified. RoB 2 and ROBINS-I judgments were interpreted according to their respective tool-specific categories, whereas JBI assessments were summarized qualitatively without applying an arbitrary numerical score.
2.7. Reporting Bias and Certainty of Evidence
Risk of bias due to missing results was assessed by considering selective outcome reporting and the availability of prespecified outcomes when study protocols or trial registrations were available. Assessment of small-study effects and publication bias using funnel plots and statistical tests for asymmetry was planned only when at least 10 studies contributed to the same meta-analysis.
The certainty of evidence for the primary outcome was assessed using the GRADE approach, considering risk of bias, inconsistency, indirectness, imprecision, and publication bias. Randomized evidence initially received a high-certainty rating and was downgraded when warranted according to these domains. Certainty was classified as high, moderate, low, or very low.
2.8. Outcomes
The primary outcome was distance visual acuity, preferably expressed in logMAR units. For comparative studies, between-group differences at a clinically comparable follow-up were prioritized. Change-from-baseline data were used when reported and methodologically appropriate, whereas final-value comparisons were used when change scores were unavailable or not directly comparable. Uncontrolled pre-post studies were analyzed separately. When visual acuity was reported using another scale, conversion to logMAR was planned when methodologically appropriate.
Secondary outcomes included near visual acuity, reading performance, reading speed, critical print size, contrast sensitivity, fixation stability, PRL location and displacement, microperimetric parameters, vision-related quality of life, treatment tolerance, adherence, and the proportion of participants showing functional or visual improvement.
When both adjusted and unadjusted comparative estimates were available, unadjusted final-value data were used for pooling only when necessary to maintain consistency across studies and when adjusted estimates were not directly comparable across trials.
2.9. Statistical Analysis
Meta-analysis was planned when at least two studies were considered sufficiently comparable in terms of population, intervention, study design, and outcome definition. Because clinical and methodological heterogeneity was expected across studies, random-effects models were planned as the primary analytical approach.
For continuous outcomes reported on the same scale, mean differences (MDs) with 95% confidence intervals (CIs) were to be calculated. When conceptually similar outcomes were assessed using different scales, standardized mean differences (SMDs) were considered. For dichotomous outcomes, risk ratios (RRs) with 95% CIs were used. In uncontrolled case series, pooled proportions could be calculated when the definition of improvement was sufficiently consistent across studies.
Controlled studies and uncontrolled pre-post studies were analyzed separately whenever possible. Clinically distinct outcomes were not combined within a single pooled estimate. Separate quantitative syntheses were therefore planned for distance visual acuity, near vision or reading performance, PRL or fixation outcomes, and the proportion of participants showing visual or functional improvement.
Statistical heterogeneity was assessed using the I2 statistic and Cochran’s Q test. Given the small number of studies contributing to some quantitative syntheses, particularly the primary meta-analysis, heterogeneity estimates were interpreted descriptively rather than as precise measures of between-study variability. When quantitative pooling was not considered clinically or methodologically appropriate, findings were summarized using a structured narrative synthesis.
The primary quantitative synthesis was based on controlled studies reporting comparable visual-acuity outcomes. Uncontrolled pre-post studies and case series were synthesized separately and were not pooled with controlled studies in the primary analysis. Studies judged to be at serious or critical risk of bias were excluded from the primary pooled estimate and considered in sensitivity analyses or narrative synthesis, as appropriate.
Sensitivity analyses were performed to examine the influence of including studies excluded from the primary analysis because of high or critical risk of bias, reporting concerns, or non-randomized study design. These analyses assessed the impact of adding Tanveer et al. (2023) and Al-Karmi and Markowitz (2006) to the primary pooled estimate.
All statistical analyses were performed using Python (version 3.13.5; Python Software Foundation, Wilmington, DE, USA). Random-effects models were fitted using the DerSimonian–Laird estimator for between-study variance, and 95% confidence intervals were calculated using the normal approximation. Statistical significance was defined as a two-sided p value < 0.05. Because the primary meta-analysis included only two studies, estimates of between-study heterogeneity and the pooled effect were interpreted cautiously.
Given that only two studies contributed to the primary meta-analysis, the pooled estimate was considered exploratory, and no strong inference was based on the magnitude of between-study heterogeneity.
3. Results
3.1. Study Selection
The database searches identified 1,167 records, including 705 from Scopus, 224 from Web of Science Core Collection, 190 from PubMed/MEDLINE, and 48 from the Cochrane Library/CENTRAL. After merging the retrieved records and removing duplicates, 782 unique records remained for title and abstract screening. Records considered potentially eligible or uncertain were subsequently assessed in greater detail, and full-text reports were retrieved whenever available. When full-text articles could not be obtained, sufficiently detailed abstracts or other available reports were considered for eligibility assessment, as prespecified in the review methodology. After completion of the screening and eligibility assessment, 11 studies met the inclusion criteria and were retained for the systematic review. The complete study-selection process is presented in Figure 1.
Nine reports were excluded after eligibility assessment: four reviews or reports without primary clinical data [10,19,22,23], three studies evaluating interventions or objectives outside the scope of prism-based macular rehabilitation [24,25,26], one study involving an ineligible clinical population or rehabilitation context [27], and one study evaluating a non-comparable intraocular prism intervention [28].
3.2. Study Characteristics
Eleven studies met the eligibility criteria and were included in the systematic review. The 11 included studies were Rosenberg et al. [29], Verezen et al. [30], Bertrand et al. [31], Parodi et al. [14], Vettard et al. [15], Smith et al. [17], Al-Karmi and Markowitz [12], Reyes et al. [13], Lewerenz et al. [18], Markowitz et al. [11], and Tanveer et al. [32].
The evidence base comprised randomized controlled trials, comparative non-randomized studies, and observational or pre–post designs, reflecting substantial methodological heterogeneity. Most studies included patients with age-related macular degeneration and central vision loss, although some investigated broader populations with macular dysfunction or central scotoma. Prism interventions also varied considerably across studies in terms of prism power, monocular or binocular application, orientation, and whether image relocation was individualized according to the preferred retinal locus. Follow-up ranged from immediate post-fitting assessment to several months or longer-term observation. Distance visual acuity was the most frequently reported outcome, while additional outcomes included near visual performance, reading measures, preferred retinal locus characteristics, fixation stability, functional vision, spectacle use, and tolerability. Detailed characteristics of the included studies are provided in Supplementary Table S1.
3.3. Risk of Bias and Methodological Quality
Risk of bias and methodological quality varied substantially across the included studies, reflecting the diversity of study designs (Table 1). Among the randomized controlled trials assessed using RoB 2, Rosenberg et al. (1989), Parodi et al. (2004), and Smith et al. (2005) were judged as having some concerns, whereas Tanveer et al. (2023) was classified as being at high risk of bias. Rosenberg et al. (1989) used quasi-random allocation based on the odd or even case number assigned at intake, resulting in a predictable allocation sequence and therefore some concerns in the randomization domain. The non-randomized comparative study by Al-Karmi and Markowitz (2006), assessed using ROBINS-I, was judged as having a critical risk of bias, primarily because of concerns related to confounding and participant selection.
The remaining observational and quasi-experimental studies, evaluated using the appropriate Joanna Briggs Institute critical appraisal tools, showed varying levels of methodological concern, ranging from moderate to high. Across the evidence base, the main methodological limitations included potential confounding and participant selection in non-randomized studies, the absence of concurrent control groups in several observational designs, and concerns related to deviations from intended interventions, missing outcome data, or selective outcome reporting in some randomized trials. These limitations were particularly relevant in studies in which prism prescription was individualized according to the patient’s response or preferred retinal locus, as treatment selection could be influenced by the initial response to prism testing. Detailed domain- and item-level assessments are provided in Supplementary Table S2–S4.
3.4. Effect of Prism Correction on Distance Visual Acuity
Two randomized controlled trials provided sufficiently comparable data for the primary meta-analysis of distance visual acuity at approximately 3 months. These trials were considered sufficiently comparable because both evaluated prism spectacles against non-prismatic control conditions and reported distance visual acuity in logMAR units at approximately 3 months.
The random-effects analysis showed a pooled mean difference of −0.218 logMAR (95% CI, −0.522 to 0.086), in the direction of better visual acuity with prism correction, although the confidence interval included the null value (Figure 2). Considerable between-study heterogeneity was observed (I2 = 94.5%), reflecting the marked difference in effect estimates between the two trials. Given the small number of studies contributing to the analysis, both the pooled estimate and the heterogeneity should be interpreted cautiously.
For Smith et al. (2005), final visual-acuity values were used because the adjusted ANCOVA estimate was not directly comparable with the available effect measure from Parodi et al. (2004). Using final values allowed both trials to be synthesized on the same effect scale.
The certainty of evidence for the effect of prism correction on distance visual acuity was rated as very low according to the GRADE framework, primarily because of concerns regarding risk of bias, substantial inconsistency between trials, and imprecision of the pooled estimate (Supplementary Table S5).
3.5. Sensitivity Analyses
Sensitivity analyses were performed to examine the robustness of the primary findings. When Tanveer et al. (2023) was added to the primary analysis using the visual acuity values as reported in the published table, the pooled mean difference moved towards the null (MD, −0.083 logMAR; 95% CI, −0.392 to 0.226) and heterogeneity increased substantially (I2 = 97.9%) (Figure 3). Importantly, the direction of the effect derived from the published numerical data was inconsistent with the authors’ narrative interpretation; therefore, this study was not included in the primary meta-analysis. This decision was based on internal inconsistency in the published reporting rather than on the direction or magnitude of the observed effect.
A second sensitivity analysis incorporated the non-randomized comparative study by Al-Karmi and Markowitz (2006). Inclusion of this study produced only a modest change in the pooled estimate (MD, −0.203 logMAR; 95% CI, −0.415 to 0.009), which remained in the direction of better visual acuity with prism correction, with substantial heterogeneity (I2 = 89.1%) (Figure 4). However, because treatment allocation in this retrospective study was strongly influenced by the initial response to prism testing, the study was considered at critical risk of bias and was not included in the primary analysis.
3.6. Other Visual and Functional Outcomes
Outcomes other than distance visual acuity were heterogeneous across studies and could not be quantitatively pooled. These included near visual performance and reading ability, preferred retinal locus (PRL) characteristics and fixation behaviour, as well as patient-reported functional outcomes and spectacle use. The outcomes assessed across individual studies are summarized in Supplementary Table S1.
Several studies evaluated near vision or reading-related outcomes following prism correction. Improvements were reported in some cohorts; however, differences in outcome definitions, testing procedures, prism prescriptions, associated magnification, and follow-up limited direct comparison between studies. In particular, when prism spectacles incorporated additional refractive or magnifying components, the specific contribution of image relocation to the observed near-vision benefit could not be isolated.
Other studies investigated the ability of prisms to alter retinal image location relative to an eccentric retinal area or PRL. Changes in fixation location or stability were observed after prism placement, supporting a measurable optical effect. However, the magnitude and direction of these changes varied across participants and studies, and evidence linking retinal relocation to sustained functional improvement remained limited.
Patient-reported outcomes were also inconsistent. Some studies described perceived improvements in everyday visual tasks or continued spectacle use, whereas others reported limited benefit or adaptation difficulties. Differences in the instruments used and the predominantly observational nature of these data precluded quantitative synthesis.
3.7. Tolerability and Spectacle Use
Tolerability and continued use of prism spectacles were inconsistently reported across studies. Most reports suggested that at least a proportion of participants were able to adapt to and continue using the prescribed prism correction, although acceptance varied between individuals. In Parodi et al. (2004), two participants discontinued prism use shortly after prescription because of difficulties while walking. In the retrospective study by Al-Karmi and Markowitz (2006), long-term use was documented among patients who had initially perceived benefit from prism testing; however, this finding should be interpreted cautiously because continued use was partly conditioned by response-based treatment selection.
Overall, the available evidence suggests that prism spectacles are tolerated by some patients with central vision loss, but continued spectacle use should not be interpreted as a direct measure of efficacy or tolerability. The heterogeneity of reporting and the absence of standardized measures of adherence, adverse effects, mobility-related difficulties, and acceptability precluded quantitative synthesis of these outcomes.
4. Discussion
The present systematic review and meta-analysis provides a comprehensive synthesis of the available evidence on prismatic image relocation for visual rehabilitation in patients with macular disease and central vision loss. The literature spans more than three decades and includes randomized controlled trials, comparative observational studies, case series, and experimental within-subject designs. Despite the long-standing clinical interest in this approach, the evidence remains limited and methodologically heterogeneous.
In the primary quantitative synthesis, the pooled estimate was in the direction of improved distance visual acuity with prism correction, but the confidence interval included the null value and substantial between-study heterogeneity was observed. These findings indicate that the magnitude and consistency of any benefit attributable specifically to prism correction remain uncertain. Accordingly, the certainty of evidence for the primary outcome was rated as very low, mainly because of risk-of-bias concerns, substantial inconsistency, and imprecision.
Our findings provide a more cautious interpretation than some earlier reports of prism-based rehabilitation. Several observational studies described improvements in visual acuity or functional performance after image relocation [11,12,13,14,15], and a previous evidence-based review concluded that prisms could improve distance visual acuity following macular function loss [19]. However, the apparent benefit was largely derived from studies with markedly different designs and, in some cases, without an independent untreated or sham-treated comparison group. In contrast, the present review distinguished randomized evidence from uncontrolled and non-randomized evidence and restricted the primary meta-analysis to sufficiently comparable randomized studies. This distinction is important because improvements observed after low-vision intervention may result from several concurrent factors, including refractive optimization, magnification, training, repeated testing, adaptation to eccentric viewing, or selective prescription to patients who respond favourably during fitting [20,33,34].
This issue is particularly evident in the study by Al-Karmi and Markowitz [12]. Patients who perceived benefit during prism testing were subsequently prescribed prism spectacles, whereas those in whom prism correction was not considered beneficial formed the non-prism comparison group. Such treatment selection makes the groups intrinsically different with respect to initial treatment response and substantially limits causal interpretation. The more favourable results reported in this type of observational cohort should therefore not be considered equivalent to an effect demonstrated in randomized comparisons. This consideration also supports our decision to include this study only in sensitivity analysis rather than in the primary pooled estimate.
The considerable heterogeneity between the randomized trials is clinically plausible. Prism prescription differed in power, orientation, monocular or binocular application, and degree of individualization [14,17]. Patients also differed in severity of macular damage, eccentric fixation characteristics, residual visual function, and possibly duration of visual loss. More broadly, systematic reviews of low-vision rehabilitation have repeatedly emphasized substantial heterogeneity in interventions, patient characteristics, outcome measures, and service-delivery models [20,33,34]. In a randomized trial of different models of low-vision rehabilitation in AMD, Reeves et al. found no additional advantage of an enhanced home-based model over conventional rehabilitation despite high use of low-vision devices at follow-up [35]. These findings illustrate why improvement after rehabilitation cannot automatically be attributed to any single component of a multifaceted intervention.
A central rationale for prismatic image relocation is the presence of a preferred retinal locus. However, current knowledge indicates that the PRL is considerably more complex than a fixed eccentric substitute for the fovea. The PRL may be task dependent, more than one locus may be used, and fixation behaviour may evolve over time [2,3]. Longitudinal work by Crossland et al. showed that patients with recent central visual loss can develop a repeatable PRL over the months following the onset of bilateral macular disease, while some patients use multiple retinal loci [36,37]. Importantly, the naturally adopted PRL does not necessarily coincide with the retinal location providing the best visual acuity [4]. Bernard and Chung demonstrated that visual acuity could be better at retinal locations away from the habitual PRL, suggesting that PRL selection is influenced by factors beyond local resolution alone [4]. This is highly relevant to prism prescription because relocating an image toward an anatomically available retinal region does not necessarily guarantee improved functional performance.
The relationship between PRL position and visual function is further complicated by fixation stability. Fixation characteristics have been associated with reading performance in patients with macular disease, while PRL eccentricity itself does not fully explain functional ability [6,7,36]. The findings of Lewerenz et al. [18] are therefore particularly relevant: prism placement can produce measurable changes in retinal image location, but the resulting displacement is not necessarily equivalent to stable adoption of a new functional PRL. This distinction between optical image displacement, oculomotor adaptation, and functional benefit should be maintained when interpreting prism studies.
Microperimetry offers an important means of addressing this issue. Unlike visual acuity alone, fundus-tracked microperimetry permits simultaneous assessment of retinal sensitivity, fixation location, fixation stability, and their relationship to retinal structure [38]. Systematic evidence suggests that retinal sensitivity measured by microperimetry can detect functional abnormalities and progression in AMD that may not be fully captured by conventional visual acuity testing, although variation in testing protocols remains an important limitation [38,39]. This has direct implications for future prism trials. Demonstrating that an image has been displaced is insufficient; studies should establish whether the prism consistently redirects fixation toward a retinal area with greater sensitivity or superior task-specific function and whether this relocation persists under binocular, real-world viewing conditions.
The findings concerning near vision and reading should also be interpreted within the wider context of low-vision rehabilitation. Reading impairment is one of the most disabling consequences of central vision loss, but reading performance depends on multiple factors beyond high-contrast distance acuity. Appropriate magnification alone can substantially improve reading performance in patients with AMD. In a large clinical series, Nguyen et al. reported marked improvement in reading ability after prescription of appropriate low-vision aids [40]. Consequently, when prism spectacles incorporate additional refractive or magnifying components, improvements in near performance cannot necessarily be attributed to image relocation itself.
Training can also influence reading performance independently of prism correction. Seiple et al. demonstrated that different rehabilitation strategies produce different effects on reading, with training directed toward reading eye movements producing greater improvement than visual awareness/eccentric-viewing training alone [41]. Similarly, Kaltenegger et al. found that home-based reading training added to magnifying aids improved reading speed and patient-reported outcomes in AMD, despite no corresponding change in fixation parameters [42]. A previous meta-analysis also reported improvement in reading speed following low-vision rehabilitation, while emphasizing the heterogeneity and limited quality of the underlying evidence [43]. Collectively, these findings reinforce the need for future prism studies to isolate the specific optical effect of the prism from accompanying magnification, refractive correction, rehabilitation instruction, and practice effects.
Evidence from eccentric-viewing rehabilitation provides a further useful comparison. Earlier literature suggested that eccentric-viewing and steady-eye strategies could improve near visual acuity, reading speed, or activities of daily living, but relatively few controlled trials were available [21]. More recently, the large EFFECT randomized controlled trial compared standard low-vision rehabilitation with supervised reading support, training of the habitual PRL, and biofeedback training of a theoretically optimal retinal locus in 200 patients with age-related macular disease [44]. No systematic advantage was found for eccentric-viewing training in visual task ability, reading performance, or fixation stability. The study is particularly relevant to the present review because it indicates that directing fixation toward a selected retinal locus does not necessarily translate into improved functional performance. Thus, the theoretical plausibility of optimizing retinal image position should not be equated with demonstrated clinical effectiveness.
Nevertheless, the lack of a uniform effect does not exclude the possibility that specific subgroups may respond to retinal-locus–based rehabilitation. Studies of microperimetric biofeedback have reported improvements in visual acuity, near vision, reading speed, or fixation control in patients with AMD or central visual loss [45,46]. Differences between these findings and those of the EFFECT trial suggest that treatment response may depend on disease stage, residual retinal function, stability of the selected locus, intensity of training, or patient selection. The same may apply to prism correction. Rather than seeking a uniform average effect across all patients with macular disease, future investigations may need to identify characteristics that predict a clinically meaningful response.
Patient-reported outcomes are also important when evaluating low-vision interventions. Central vision loss affects reading, mobility, social participation, emotional well-being, and independence, and these consequences are not adequately represented by distance visual acuity alone [20,34]. Contemporary reviews of low-vision rehabilitation have therefore emphasized vision-related quality of life and functional ability as core outcomes [33,34]. Studies specifically involving patients with geographic atrophy also demonstrate substantial impairment in near activities, mental health, role function, and other aspects of vision-related quality of life [47]. This broader perspective is particularly relevant to prism spectacles because a relatively small change in measured acuity might be clinically meaningful if accompanied by better reading or daily functioning, whereas an improvement in chart acuity without improved real-world performance may have limited relevance.
Tolerability deserves similar attention. Although several included studies described continued spectacle use or subjective benefit, acceptance was not uniform. In Parodi et al. [14], two participants discontinued prism use shortly after prescription because of difficulties while walking. Long-term spectacle use reported in observational cohorts must also be interpreted cautiously when continued use itself is partly determined by an initially favourable response. Image displacement may potentially affect orientation, target localization, or mobility, and future trials should therefore measure adverse effects and treatment discontinuation prospectively rather than treating spectacle use solely as an indirect marker of benefit.
The clinical implications of the present findings should therefore be considered within an individualized rehabilitation framework. Current evidence does not support the assumption that a fixed prism strategy will produce a predictable improvement across patients with central vision loss. At the same time, it does not rule out clinically relevant benefit in selected individuals. PRL position, fixation stability, scotoma morphology, residual retinal sensitivity, binocular status, visual task requirements, and adaptation capacity may all influence treatment response [2,4,6,7,38]. Contemporary low-vision rehabilitation increasingly recognizes this heterogeneity, with intervention selection based on individual goals and residual visual function rather than visual acuity alone [33,34,48]. The Veterans Affairs Low Vision Intervention Trial II, for example, showed that adding structured rehabilitation therapy to provision of low-vision devices can improve visual ability in patients with macular disease, emphasizing the value of training and task-specific rehabilitation alongside optical devices [48].
The present review has several strengths. A broad search strategy was applied across four major databases without restrictions on publication date or language, and 782 unique records were screened after deduplication. Different study designs were retained in order to characterize the complete clinical evidence base, but design-specific risk-of-bias tools were used and randomized evidence was kept separate from non-randomized evidence in the primary quantitative synthesis. Sensitivity analyses were used to evaluate the influence of studies with important methodological or reporting concerns. This approach is especially relevant in a field in which much of the historical evidence consists of small observational series and individualized clinical prescriptions.
Several limitations should also be acknowledged. First, only two sufficiently comparable randomized trials contributed to the primary meta-analysis of distance visual acuity. Consequently, the pooled estimate is imprecise and estimates of between-study heterogeneity are themselves uncertain. Second, interventions differed in prism design, power, orientation, fitting strategy, and associated optical correction. Third, disease characteristics and outcome definitions varied considerably across studies. Fourth, some older studies were available only through abstracts or incompletely reported records, restricting both data extraction and methodological assessment. Fifth, outcomes other than distance visual acuity were insufficiently standardized to permit quantitative pooling. Finally, several observational studies were particularly vulnerable to selection and confounding because prism prescription depended on the initial response observed during clinical fitting. These limitations preclude a definitive estimate of the efficacy of prismatic image relocation.
Future trials should use adequately powered randomized designs with clearly described allocation procedures, appropriate masking whenever feasible, and prespecified analytical plans. Visual acuity should be assessed using standardized logMAR procedures, but it should not be the only primary measure. Reading speed and critical print size, task-based visual performance, patient-reported visual function, treatment adherence, mobility, comfort, and adverse effects should be collected using validated instruments. Microperimetry should be incorporated to document baseline PRL characteristics, retinal sensitivity, fixation stability, and the actual retinal displacement produced by the prism [38,39]. Importantly, future work should examine whether baseline structural or functional characteristics predict response. Establishing which patients benefit from prismatic relocation may ultimately be more clinically informative than estimating a single average effect across a highly heterogeneous population.
5. Conclusions
The available evidence indicates that prismatic image relocation can modify retinal image position and may provide visual or functional benefit in selected patients with central vision loss, although the certainty of evidence regarding its effect on distance visual acuity is very low. However, the randomized evidence remains limited, the pooled estimate for distance visual acuity is imprecise, and substantial heterogeneity exists between studies. More favourable effects have frequently been reported in observational studies, but these findings are tempered by important methodological limitations, particularly selection and confounding. Current evidence therefore supports considering prism correction as a potentially individualized component of low-vision rehabilitation rather than a uniformly effective intervention. Well-designed randomized trials integrating microperimetric characterization of the PRL with standardized visual, functional, patient-reported, and tolerability outcomes are needed to identify the patients most likely to benefit.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/doi/s1: Table S1: Characteristics of the studies included in the systematic review; Table S2: Risk-of-bias and methodological quality assessment of the included studies; Table S3: Detailed domain-level risk-of-bias assessment; Table S4: Detailed methodological quality assessment of observational and quasi-experimental studies; Table S5: GRADE assessment of the certainty of evidence for the primary outcome; File S6: PRISMA 2020 checklist.
Author Contributions
Conceptualization, F.J.P.-M. and J.E.C.-S.; methodology, F.J.P.-M., R.G.-J., R.B.-V. and J.E.C.-S.; software, F.J.P.-M.; validation, F.J.P.-M., R.G.-J., R.B.-V. and J.E.C.-S.; formal analysis, F.J.P.-M.; investigation, F.J.P.-M., R.G.-J., R.B.-V. and S.B.-S.; data curation, F.J.P.-M., R.G.-J., R.B.-V. and S.B.-S.; writing—original draft preparation, F.J.P.-M.; writing—review and editing, F.J.P.-M., R.G.-J., R.B.-V., S.B.-S. and J.E.C.-S.; visualization, F.J.P.-M.; supervision, F.J.P.-M. and J.E.C.-S.; project administration, F.J.P.-M. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable. This study is a systematic review and meta-analysis of previously published data and did not involve the direct recruitment of human participants or the collection of new individual-level data.
Informed Consent Statement
Not applicable. This study is a systematic review and meta-analysis of previously published data and did not involve the direct recruitment of human participants.
Data Availability Statement
The data supporting the findings of this systematic review and meta-analysis were derived from previously published studies and are reported in the article and its Supplementary Materials. The extracted data used for the quantitative analyses and the risk-of-bias and certainty-of-evidence assessments are available from the corresponding author upon reasonable request.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| Abbreviation | Definition |
| AMD | Age-related macular degeneration |
| CI | Confidence interval |
| CENTRAL | Cochrane Central Register of Controlled Trials |
| GRADE | Grading of Recommendations Assessment, Development and Evaluation |
| JBI | Joanna Briggs Institute |
| logMAR | Logarithm of the minimum angle of resolution |
| MD | Mean difference |
| PRISMA | Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
| PRL | Preferred retinal locus |
| RoB 2 | Risk of Bias 2 |
| ROBINS-I | Risk Of Bias In Non-randomized Studies of Interventions |
| RR | Risk ratio |
| SMD | Standardized mean difference |
References
- Kolawole, O.U.; Bensinger, E.; Wong, J.; Rinella, N.; Foote, K.G.; Zhou, H.; et al. High Resolution Imaging and Fixation Analysis of Eccentric Preferred Retinal Loci in Macular Diseases. Invest Ophthalmol. Vis. Sci. 2025, 66(5), 18. [Google Scholar] [CrossRef] [PubMed]
- Tarita-Nistor, L.; Sverdlichenko, I.; Mandelcorn, M.S. What Is a Preferred Retinal Locus? Annu Rev. Vis. Sci. 2023, 9, 201–20. [Google Scholar] [CrossRef] [PubMed]
- Crossland, M.D.; Engel, S.A.; Legge, G.E. The preferred retinal locus in macular disease: toward a consensus definition. Retina 2011, 31(10), 2109–14. [Google Scholar] [CrossRef] [PubMed]
- Bernard, J.B.; Chung, S.T.L. Visual Acuity Is Not the Best at the Preferred Retinal Locus in People with Macular Disease. Optom. Vis. Sci. 2018, 95(9), 829–36. [Google Scholar] [CrossRef] [PubMed]
- Li, S.; Li, D.; Wang, L.; Lin, H.; Zhang, J. The natural preferred retinal locus in patients with macular disease. Sci. Rep. 2025, 15(1), 25348. [Google Scholar] [CrossRef] [PubMed]
- Greenstein, V.C.; Santos, R.A.; Tsang, S.H.; Smith, R.T.; Barile, G.R.; Seiple, W. Preferred retinal locus in macular disease: characteristics and clinical implications. Retina 2008, 28(9), 1234–40. [Google Scholar] [CrossRef] [PubMed]
- Altınbay, D.; İdil, Ş. A. Fixation Stability and Preferred Retinal Locus in Advanced Age-Related Macular Degeneration. Turk. J. Ophthalmol. 2022, 52(1), 23–9. [Google Scholar] [CrossRef] [PubMed]
- Li, S.; Deng, X.; Zhang, J. An Overview of Preferred Retinal Locus and Its Application in Biofeedback Training for Low-Vision Rehabilitation. Semin Ophthalmol. 2022, 37(2), 142–52. [Google Scholar] [CrossRef] [PubMed]
- Barraza-Bernal, M.J.; Rifai, K.; Wahl, S. A preferred retinal location of fixation can be induced when systematic stimulus relocations are applied. J. Vis. 2017, 17(2), 11. [Google Scholar] [CrossRef] [PubMed]
- Goodrich, G.L.; Mehr, E.B. Eccentric viewing training and low vision aids: current practice and implications of peripheral retinal research. Am. J. Optom. Physiol. Opt. 1986, 63(2), 119–26. [Google Scholar] [PubMed]
- Markowitz, S.N.; Teplitsky, J.E.; Taheri-Shirazi, M. Restitution of potential visual acuity in low vision patients with the use of yoke prisms. J. Optom. 2021, 14(4), 342–5. [Google Scholar] [CrossRef] [PubMed]
- Al-Karmi, R.; Markowitz, S.N. Image relocation with prisms in patients with age-related macular degeneration. Can. J. Ophthalmol. 2006, 41(3), 313–8. [Google Scholar] [CrossRef] [PubMed]
- Reyes, S.V.; Silvestri, V.; Amore, F.; Markowitz, S.N. Use of prisms for vision rehabilitation after macular function loss may impact oculomotor control. Can. J. Ophthalmol. 2013, 48(5), 427–30. [Google Scholar] [CrossRef] [PubMed]
- Parodi, M.B.; Toto, L.; Mastropasqua, L.; Depollo, M.; Ravalico, G. Prismatic correction in patients affected by age-related macular degeneration. Clin. Rehabil. 2004, 18(7), 828–32. [Google Scholar] [CrossRef] [PubMed]
- Vettard, S.; Dubois, E.; Quaranta, M.; Mauget-Faÿsse, M. [Prismatic treatment in low-vision rehabilitation of patients with age-related macular degeneration]. J. Fr. Ophtalmol. 2004, 27 6 Pt 1, 589–96. [Google Scholar] [CrossRef] [PubMed]
- González, E.G.; Tarita-Nistor, L.; Markowitz, S.N.; Steinbach, M.J. Computer-based test to measure optimal visual acuity in age-related macular degeneration. Invest Ophthalmol. Vis. Sci. 2007, 48(10), 4838–45. [Google Scholar] [CrossRef] [PubMed]
- Smith, H.J.; Dickinson, C.M.; Cacho, I.; Reeves, B.C.; Harper, R.A. A randomized controlled trial to determine the effectiveness of prism spectacles for patients with age-related macular degeneration. Arch. Ophthalmol. 2005, 123(8), 1042–50. [Google Scholar] [CrossRef] [PubMed]
- Lewerenz, D.; Blanco, D.; Ratzlaff, C.; Zodrow, A. The effect of prism on preferred retinal locus. Clin. Exp. Optom. 2018, 101(2), 260–6. [Google Scholar] [CrossRef] [PubMed]
- Markowitz, S.N.; Reyes, S.V.; Sheng, L. The use of prisms for vision rehabilitation after macular function loss: an evidence-based review. Acta Ophthalmol. 2013, 91(3), 207–11. [Google Scholar] [CrossRef] [PubMed]
- Macnamara, A.; Chen, C.S.; Davies, A.; Sloan, C.; Loetscher, T. Low vision devices for age-related macular degeneration: a systematic review. Disabil. Rehabil. Assist Technol. 2023, 18(7), 998–1010. [Google Scholar] [CrossRef] [PubMed]
- Gaffney, A.J.; Margrain, T.H.; Bunce, C.V.; Binns, A.M. How effective is eccentric viewing training? A systematic literature review. Ophthalmic Physiol. Opt. 2014, 34(4), 427–37. [Google Scholar] [CrossRef] [PubMed]
- Serdiuchenko, V.I. Use of prisms in ophthalmology: a review. Part 2. Use of prisms in heterophoria, nystagmus, and visual nervous system disorders. Oftalmol. Zhurnal 2022, 97(2), 48–53. [Google Scholar] [CrossRef]
- Markowitz, S.N. Principles of modern low vision rehabilitation. Can. J. Ophthalmol. 2006, 41(3), 289–312. [Google Scholar] [CrossRef] [PubMed]
- Skrbek, M. Binocular refraction in patients with age-related macular degeneration. Coll. Antropol. 2013, 37 Suppl 1, 153–6. [Google Scholar] [PubMed]
- Silverberg, M.; Schuler, E.; Veronneau-Troutman, S.; Wald, K.; Schlossman, A.; Medow, N. Nonsurgical management of binocular diplopia induced by macular pathology. Arch. Ophthalmol. 1999, 117(7), 900–3. [Google Scholar] [CrossRef] [PubMed]
- Tabernero, J.; Qureshi, M.A.; Robbie, S.J.; Artal, P. An aspheric intraocular telescope for age-related macular degeneration patients. BioMed Opt. Express 2015, 6(3), 1010–20. [Google Scholar] [CrossRef] [PubMed]
- Houston, K.E.; Keilty, M.; Collins, C.; Trehan, R.; Mouldovan, T.; Stuckart, K.; et al. Development and 5-year Evaluation of Diagnosis-Specific Protocols for Visual Neuro-Rehabilitation in a Multicenter Inpatient Rehabilitation Network. Arch. Rehabil. Res. Clin. Transl. 2023, 5(1), 100246. [Google Scholar] [CrossRef] [PubMed]
- Potgieter, F.J.; Claoué, C.M. Safety and efficacy of an intraocular Fresnel prism intraocular lens in patients with advanced macular disease: initial clinical experience. J. Cataract Refract Surg. 2014, 40(7), 1085–91. [Google Scholar] [CrossRef] [PubMed]
- Rosenberg, R.; Faye, E.; Fischer, M.; Budick, D. Role of prism relocation in improving visual performance of patients with macular dysfunction. Optom. Vis. Sci. 1989, 66(11), 747–50. [Google Scholar] [CrossRef] [PubMed]
- Verezen, C.A.; Völker-Dieben, H.J.; Hoyng, C.B. Eccentric viewing spectacles in everyday life, for the optimum use of residual functional retinal areas, in patients with age-related macular degeneration. Optom. Vis. Sci. 1996, 73(6), 413–7. [Google Scholar] [CrossRef] [PubMed]
- Bertrand, T.; Junginger, H.; Romanet, J.P.; Mouillon, M. [Description of the prismation method in the rehabilitation of low visions of macular origin]. J. Fr. Ophtalmol. 1997, 20(4), 271–6. [Google Scholar] [PubMed]
- Tanveer, M.; Kiran, A.; Hussain, M.; Rehman, A. Effectiveness of Prism Spectacles in Patients with Age Related Macular Degeneration: A randomized control trial study: Doi: 10.36351/pjo.v39i1.1471. Pak. J. Ophthalmol. 2022, 39. [Google Scholar] [CrossRef]
- Hooper, P.; Jutai, J.W.; Strong, G.; Russell-Minda, E. Age-related macular degeneration and low-vision rehabilitation: a systematic review. Can. J. Ophthalmol. 2008, 43(2), 180–7. [Google Scholar] [CrossRef] [PubMed]
- van Nispen, R.M.; Virgili, G.; Hoeben, M.; Langelaan, M.; Klevering, J.; Keunen, J.E.; et al. Low vision rehabilitation for better quality of life in visually impaired adults. Cochrane Database Syst. Rev. 2020, 1(1), Cd006543. [Google Scholar] [CrossRef] [PubMed]
- Reeves, B.C.; Harper, R.A.; Russell, W.B. Enhanced low vision rehabilitation for people with age related macular degeneration: a randomised controlled trial. Br. J. Ophthalmol. 2004, 88(11), 1443–9. [Google Scholar] [CrossRef] [PubMed]
- Crossland, M.D.; Culham, L.E.; Rubin, G.S. Fixation stability and reading speed in patients with newly developed macular disease. Ophthalmic Physiol. Opt. 2004, 24(4), 327–33. [Google Scholar] [CrossRef] [PubMed]
- Crossland, M.D.; Culham, L.E.; Kabanarou, S.A.; Rubin, G.S. Preferred retinal locus development in patients with macular disease. Ophthalmology 2005, 112(9), 1579–85. [Google Scholar] [CrossRef] [PubMed]
- Cassels, N.K.; Wild, J.M.; Margrain, T.H.; Chong, V.; Acton, J.H. The use of microperimetry in assessing visual function in age-related macular degeneration. Surv. Ophthalmol. 2018, 63(1), 40–55. [Google Scholar] [CrossRef] [PubMed]
- Wong, E.N.; Chew, A.L.; Morgan, W.H.; Patel, P.J.; Chen, F.K. The Use of Microperimetry to Detect Functional Progression in Non-Neovascular Age-Related Macular Degeneration: A Systematic Review. Asia Pac. J. Ophthalmol. (Phila) 2017, 6(1), 70–9. [Google Scholar] [CrossRef] [PubMed]
- Nguyen, N.X.; Weismann, M.; Trauzettel-Klosinski, S. Improvement of reading speed after providing of low vision aids in patients with age-related macular degeneration. Acta Ophthalmol. 2009, 87(8), 849–53. [Google Scholar] [CrossRef] [PubMed]
- Seiple, W.; Grant, P.; Szlyk, J.P. Reading rehabilitation of individuals with AMD: relative effectiveness of training approaches. Invest Ophthalmol. Vis. Sci. 2011, 52(6), 2938–44. [Google Scholar] [CrossRef] [PubMed]
- Kaltenegger, K.; Kuester, S.; Altpeter-Ott, E.; Eschweiler, G.W.; Cordey, A.; Ivanov, I.V.; et al. Effects of home reading training on reading and quality of life in AMD-a randomized and controlled study. Graefes Arch. Clin. Exp. Ophthalmol. 2019, 257(7), 1499–512. [Google Scholar] [CrossRef] [PubMed]
- Hamade, N.; Hodge, W.G.; Rakibuz-Zaman, M.; Malvankar-Mehta, M.S. The Effects of Low-Vision Rehabilitation on Reading Speed and Depression in Age Related Macular Degeneration: A Meta-Analysis. PLoS ONE 2016, 11(7), e0159254. [Google Scholar] [CrossRef] [PubMed]
- Rubin, G.S.; Crossland, M.D.; Dunbar, H.M.P.; Brown, G.M.; Petriti, B.; Roche, H.; et al. Eccentric Viewing Training for Age-Related Macular Disease: Results of a Randomized Controlled Trial (the EFFECT Study). Ophthalmol. Sci. 2024, 4(2), 100422. [Google Scholar] [CrossRef] [PubMed]
- Widihastha, S.H.; Iskandar, E.; Satari, K.; Irfani, I.; Virgana, R.; Amiruddin, P.O. Vision rehabilitation using microperimetric biofeedback training in age-related macular degeneration. Int. J. Ophthalmol. 2023, 16(6), 933–8. [Google Scholar] [CrossRef] [PubMed]
- Silvestri, V.; De Rossi, F.; Piscopo, P.; Perna, F.; Mastropasqua, L.; Turco, S.; et al. The Effect of Varied Microperimetric Biofeedback Training in Central Vision Loss: A Randomized Trial. Optom. Vis. Sci. 2023, 100(11), 737–44. [Google Scholar] [CrossRef] [PubMed]
- Krogh Nielsen, M.; Hinnerskov, J.M.V.; Sørensen, T.L. Geographic atrophy - Signs, symptoms, and quality of life. Acta Ophthalmol. 2023, 101(8), 896–902. [Google Scholar] [CrossRef] [PubMed]
- Stelmack, J.A.; Tang, X.C.; Wei, Y.; Wilcox, D.T.; Morand, T.; Brahm, K.; et al. Outcomes of the Veterans Affairs Low Vision Intervention Trial II (LOVIT II): A Randomized Clinical Trial. JAMA Ophthalmol. 2017, 135(2), 96–104. [Google Scholar] [CrossRef] [PubMed]
Figure 1.
PRISMA 2020 flow diagram of the study selection process.

Figure 2.
Forest plot of the primary meta-analysis evaluating the effect of prism spectacles on distance visual acuity (logMAR). Mean differences (MDs) with 95% confidence intervals are shown for individual studies and the pooled random-effects estimate. Negative values favour prism correction.
Figure 2.
Forest plot of the primary meta-analysis evaluating the effect of prism spectacles on distance visual acuity (logMAR). Mean differences (MDs) with 95% confidence intervals are shown for individual studies and the pooled random-effects estimate. Negative values favour prism correction.

Figure 3.
Forest plot of the sensitivity analysis including Tanveer et al. (2023).

Figure 4.
Forest plot of the sensitivity analysis including Al-Karmi and Markowitz (2006).

Table 1.
Risk-of-bias and methodological quality assessment of the included studies.
| Study | Assessment tool | Overall assessment |
| Rosenberg et al., 1989 | RoB 2 | Some concerns |
| Verezen et al., 1996 | JBI | High methodological concern |
| Bertrand et al., 1997 | JBI | High methodological concern |
| Parodi et al., 2004 | RoB 2 | Some concerns |
| Vettard et al., 2004 | JBI | Moderate-to-high methodological concern |
| Smith et al., 2005 | RoB 2 | Some concerns |
| Al-Karmi & Markowitz, 2006 | ROBINS-I | Critical risk |
| Reyes et al., 2013 | JBI | High methodological concern |
| Lewerenz et al., 2018 | JBI | Moderate methodological concern |
| Markowitz et al., 2021 | JBI | Moderate methodological concern |
| Tanveer et al., 2023 | RoB 2 | High risk |
Note: RoB 2 was used for randomized controlled trials, ROBINS-I for non-randomized comparative studies, and the appropriate Joanna Briggs Institute (JBI) critical appraisal tools for observational and quasi-experimental studies. JBI assessments are presented as review-level summaries of methodological concern and do not represent official JBI overall risk-of-bias categories. Detailed domain- and item-level assessments are provided in Supplementary Table S2–S4.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.