Reliability of Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Across Scan Protocols in Spectral-Domain Optical Coherence Tomography

Submitted:

23 April 2026

Posted:

24 April 2026

You are already at the latest version

Abstract
Objective. To assess whether modified OCT acquisition parameters improve GCIPL measurement reliability. Methods. Participants with multiple sclerosis (pwMS) and age- and sex-matched healthy controls (HC) underwent OCT (Spectralis OCT, Heidelberg Engineering, Heidelberg, Germany) at baseline and after two and four weeks. At each visit, five macular scan protocols were acquired: standard (49 lines, high-speed [HS], automated real-time tracking [ART]: 9), high-ART (49 lines, HS, ART: 50), high-lines (97 lines, HS, ART: 9), high-resolution (49 lines, high-resolution [HR], ART: 9), and maximum (97 lines, HR, ART: 50). Reliability was assessed using intraclass correlation coefficients (ICC). Absolute test-retest reproducibility was quantified using the mean absolute difference (MAD). Results. Thirty-eight eyes from nine pwMS (mean age 34.1±8.0 years, 44.4% female) and ten HC (31.7±11.1 years, 50.0% female) were included. At baseline, mean GCIPL thickness ranged from 70.8µm to 71.5µm across protocols, demonstrating excellent inter-protocol agreement (ICC 0.99; 95% confidence interval [CI]: 0.98-0.99; p< 0.001) and only marginally higher values with increased ART. Test-retest reliability was excellent for all protocols, demonstrating marginally lower absolute measurement variability of high-ART and high-lines protocols (MAD 0.26-0.27; 95% CI: 0.21-0.32), while temporal agreement remained excellent and comparable across acquisition settings. Mean acquisition time ranged from 10.6±1.6s for the standard protocol to 231.9±36.4s for the maximum protocol. Conclusions. All OCT acquisition protocols demonstrated excellent inter-protocol and test-retest reliability for GCIPL measurements. The high-lines protocol provides the most favourable balance between measurement reliability and acquisition time, supporting its potential utility for longitudinal GCIPL monitoring.
Keywords: 
;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.
Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

Disclaimer

Terms of Use

Privacy Policy

Privacy Settings

© 2026 MDPI (Basel, Switzerland) unless otherwise stated