Submitted:
04 September 2025
Posted:
05 September 2025
You are already at the latest version
Abstract

Keywords:
1. Introduction
2. Materials and Methods
2.1. Model Preparation
2.2. Master STL Creation
2.3. Scanning Procedure



2.3.1. Scanners in the Study
| Name | Manufacturer | Technology | STL Export | PLY/OBJ Colour Export | Photogrammetry |
|---|---|---|---|---|---|
| E2 | 3Shape, Copenhagen, Denmark | Structured white light desktop scanner. | YES | NO | NO |
| i900 | Medit, Seongbuk-gu, Seoul, Korea | Structured light-Active Speed 3D Video™ |
YES | YES | NO |
2.4. Design of the Study
2.4.1. Overview
2.5. Data Processing and Analysis
2.5.1. Evaluating Trueness
2.5.2. Evaluating Precision
2.5.3. Statistical Analysis
3. Results
| Block Number | Position 35 | Position 33 | Position 31 | Position 41 | Position 43 | Position 45 |
|---|---|---|---|---|---|---|
| 1 | 3.18 | 25.12 | -3.19 | 23.06 | 26.17 | 0.98 |
| 2 | 18.43 | 15.23 | -4.70 | 8.58 | 19.86 | 4.79 |
| 3 | 10.10 | 31.28 | -6.33 | 17.42 | 43.46 | 7.05 |
| 4 | 12.87 | 4.05 | 2.61 | 13.70 | 18.93 | 3.54 |
| 5 | 9.92 | 15.77 | -2.75 | 30.69 | 23.54 | -5.96 |
| 6 | 7.25 | 9.75 | 0.85 | 9.84 | 32.06 | 4.93 |
| 7 | 4.91 | 22.25 | 4.25 | 13.59 | 34.90 | 5.26 |
| 8 | 7.71 | 22.24 | 1.27 | 21.42 | 12.10 | -0.77 |
| 9 | 11.36 | -1.70 | 1.17 | 23.19 | 25.56 | 14.07 |
| 10 | 16.52 | 10.81 | -6.07 | 18.65 | 24.36 | 4.78 |
| 11 | 20.62 | 16.73 | -3.36 | 16.20 | 21.85 | 8.47 |
| 12 | 6.08 | -8.94 | -4.71 | 22.88 | 21.64 | 3.87 |
| 13 | 19.00 | 14.21 | -10.99 | 23.50 | 16.48 | 5.15 |
| 14 | 6.92 | 15.82 | -1.14 | 14.63 | 37.62 | 6.59 |
| 15 | 2.04 | 17.68 | -12.77 | 15.54 | 17.84 | -13.88 |
| 16 | 5.67 | 27.43 | -2.26 | 20.90 | 35.72 | 2.10 |
| 17 | 2.04 | 25.55 | 5.00 | 17.62 | 29.29 | -11.88 |
| 18 | 11.68 | 11.77 | -3.16 | 22.60 | 29.70 | -0.56 |
| 19 | 23.44 | 1.53 | -11.08 | 27.17 | 28.85 | 8.81 |
| 20 | 13.16 | -9.78 | -2.62 | 17.86 | 20.41 | 2.32 |
3.1. Trueness
3.2. Precision
3.3. Statistical Analysis


4. Discussion
4.1. Evaluation of Trueness and Precision in Digital Intraoral Scanners
4.2. Contribution to Existing Scientific Literature
4.3. Enhancement in Accuracy with the Scan Ladder
4.4. Comparison with Peer-Reviewed Literature
4.5. Implications for Clinical Practice
4.6. Challenges and Limitations of the Present Study
4.7. Future Directions
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Data Availability Statement
Conflicts of Interest
References
- Zafiropoulos, G.-G.; Galil, A.A.; Deli, G. An Interocclusal Recording Method for the Fabrication of Full-Arch Implant-Retained Restorations. Journal of Oral Implantology 2014. [CrossRef]
- Jain, M. Impression Techniques for the Resorbed Mandibular Arch: A Guide to Increased Stability. Journal of the Scientific Society 2015. [CrossRef]
- Leão, M.P.; Pinto, C.P.; Sponchiado, A.P.; Ornaghi, B.P. Dimensional Stability of a Novel Polyvinyl Siloxane Impression Technique. Brazilian Journal of Oral Sciences 2014. [CrossRef]
- Rutkūnas, V.; Gečiauskaitė, A.; Jegelevičius, D.; Vaitiekūnas, M. Accuracy of Digital Implant Impressions with Intraoral Scanners. A Systematic Review. European Journal of Oral Implantology 2017.
- Di Fiore, A.; Meneghello, R.; Graiff, L.; Savio, G.; Vigolo, P.; Monaco, C.; Stellini, E. Full Arch Digital Scanning Systems Performances for Implant-Supported Fixed Dental Prostheses: A Comparative Study of 8 Intraoral Scanners. Journal of Prosthodontic Research 2019. [CrossRef] [PubMed]
- Ender, A.; Mehl, A. Influence of Scanning Strategies on the Accuracy of Digital Intraoral Scanning Systems. International journal of computerized dentistry 2013. [CrossRef]
- Drancourt, N.; Auroy, P.; Veyrune, J.-L.; Osta, N.E.; Nicolas, E. Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study. Journal of Personalized Medicine 2023. [CrossRef]
- Fayad, noha E.H.; Abofadle, A.; Bahig, D. Accuracy of Different Digital Data Acquisition Work Flows for Full Arch Maxillary Implant Prostheses (an Invitro Study). Egyptian dental journal 2024. [CrossRef]
- Rutkunas, V.; Gedrimiene, A.; Adaškevičius, R.; Al-Haj Husain, N.; Özcan, M. Comparison of the Clinical Accuracy of Digital and Conventional Dental Implant Impressions. The European journal of prosthodontics and restorative dentistry 2020. [CrossRef]
- Papaspyridakos, P.; Papaspyridakos, P.; Vazouras, K.; Chen, Y.-W.; Kotina, E.; Natto, Z.S.; Natto, Z.S.; Kang, K.; Chochlidakis, K. Digital vs Conventional Implant Impressions: A Systematic Review and Meta-Analysis. Journal of Prosthodontics 2020. [CrossRef] [PubMed]
- Rahman, R.N.; Lee, A.; Lavasani, S.; Boehm, T. An Overview of Digital Workflows for Precision Implant Dentistry. Journal of the California Dental Association 2022. [CrossRef]
- Miyoshi, K.; Tanaka, S.; Yokoyama, S.; Sanda, M.; Baba, K. Effects of Different Types of Intraoral Scanners and Scanning Ranges on the Precision of Digital Implant Impressions in Edentulous Maxilla: An in Vitro Study. Clinical Oral Implants Research 2020. [CrossRef] [PubMed]
- Mangano, F.; Veronesi, G.; Hauschild, U.; Mijiritsky, E.; Mangano, C. Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study. PLOS ONE 2016. [CrossRef] [PubMed]
- Tallarico, M.; Lumbau, A.I.; Scrascia, R.; Demelas, G.; Sanseverino, F.; Amarena, R.; Meloni, S.M. Feasibility of Using a Prosthetic-Based Impression Template to Improve the Trueness and Precision of a Complete Arch Digital Impression on Four and Six Implants: An In Vitro Study. Materials 2020. [CrossRef]
- Sultanoğlu, E.G.; Keleş, B. Comparison of the Accuracy and Precision of Digital Scans for Implant-Supported Maxillary Hybrid Prosthesis: An in Vitro Study. Nigerian Journal of Clinical Practice 2024. [CrossRef]
- Giménez, B.; Özcan, M.; Martínez-Rus, F.; Pradíes, G. Accuracy of a Digital Impression System Based on Active Wavefront Sampling Technology for Implants Considering Operator Experience, Implant Angulation, and Depth. Clinical Implant Dentistry and Related Research 2015. [CrossRef]
- Cheng, J.; Zhang, H.; Liu, H.; Li, J.; Wang, H.-L.; Tao, X. Accuracy of Edentulous Full-Arch Implant Impression: An in Vitro Comparison between Conventional Impression, Intraoral Scan with and without Splinting, and Photogrammetry. Clinical Oral Implants Research 2024. [CrossRef]
- Çakmak, G.; Çakmak, G.; Yilmaz, H.; Treviño, A.; Kökat, A.M.; Yilmaz, B. The Effect of Scanner Type and Scan Body Position on the Accuracy of Complete-Arch Digital Implant Scans. Clinical Implant Dentistry and Related Research 2020. [CrossRef]
- Arcuri, L.; Pozzi, A.; Lio, F.; Rompen, E.; Zechner, W.; Nardi, A. Influence of Implant Scanbody Material, Position and Operator on the Accuracy of Digital Impression for Complete-Arch: A Randomized in Vitro Trial. Journal of Prosthodontic Research 2020. [CrossRef]
- Örtorp, A.; Jemt, T.; Bäck, T. Photogrammetry and Conventional Impressions for Recording Implant Positions: A Comparative Laboratory Study. Clinical Implant Dentistry and Related Research 2005. [CrossRef] [PubMed]
- Rivara, F.; Lumetti, S.; Calciolari, E.; Toffoli, A.; Forlani, G.; Manfredi, E. Photogrammetric Method to Measure the Discrepancy between Clinical and Software-Designed Positions of Implants. Journal of Prosthetic Dentistry 2016. [CrossRef]
- Richert, R.; Goujat, A.; Venet, L.; Viguie, G.; Viennot, S.; Robinson, P.; Farges, J.-C.; Fages, M.; Ducret, M. Intraoral Scanner Technologies: A Review to Make a Successful Impression. Journal of Healthcare Engineering 2017. [CrossRef]
- Accuracy of an Intraoral Scanner Based on Sleeve Type, Decontamination, and Calibration. 2023.
- Nulty, A.B. An In Vivo Comparison of Trueness and Precision of Two Novel Methods for Improving Edentulous Full Arch Implant Scanning Accuracy: A Pilot Study. Dent. J. 2024, 12, 367. [Google Scholar] [CrossRef] [PubMed]
- Menditto, A.; Patriarca, M.; Magnusson, B. Understanding the Meaning of Accuracy, Trueness and Precision. Accreditation and Quality Assurance 2007. [CrossRef]
- Bonnick, S.L.; Lewis, L.A. The Importance of Precision. In; 2013.
- Prenesti, E.; Gosmaro, F. Trueness, Precision and Accuracy: A Critical Overview of the Concepts as Well as Proposals for Revision. Accreditation and Quality Assurance 2015. [CrossRef]
- Bratos, M.; Bergin, J.M.; Rubenstein, J.E.; Sorensen, J.A. Effect of Simulated Intraoral Variables on the Accuracy of a Photogrammetric Imaging Technique for Complete-Arch Implant Prostheses. Journal of Prosthetic Dentistry 2018. [CrossRef]
- Bergin, J.M.; Rubenstein, J.E.; Mancl, L.; Brudvik, J.S.; Raigrodski, A.J. An in Vitro Comparison of Photogrammetric and Conventional Complete-Arch Implant Impression Techniques. Journal of Prosthetic Dentistry 2013. [CrossRef]
- Azevedo, L.; Molinero-Mourelle, P.; Antonaya-Martín, J.L.; del Río-Highsmith, J.; Correia, A.; Gómez-Polo, M. Photogrammetry Technique for the 3D Digital Impression of Multiple Dental Implants. In; 2019.
- Stuani, V. de T.; Ferreira, R.; Manfredi, G.G. do P.; Cardoso, M.V.; Sant’Ana, A.C.P. Photogrammetry as an Alternative for Acquiring Digital Dental Models: A Proof of Concept. Medical Hypotheses 2019. [CrossRef]
- De Angelis, F.; Pranno, N.; Franchina, A.; Di Carlo, V.; Brauner, E.; Ferri, A.; Pellegrino, G.; Grecchi, E.; Goker, F.; Stefanelli, L.V. Artificial Intelligence: A New Diagnostic Software in Dentistry: A Preliminary Performance Diagnostic Study. International Journal of Environmental Research and Public Health 2022. [CrossRef]
- Huang, R.; Liu, Y.; Huang, B.; Zhang, C.; Chen, Z.; Li, Z. Improved Scanning Accuracy with Newly Designed Scan Bodies: An in Vitro Study Comparing Digital versus Conventional Impression Techniques for Complete-Arch Implant Rehabilitation. Clinical Oral Implants Research 2020. [CrossRef]
- Gómez-Polo, M.; Sallorenzo, A.; Ortega, R.; Gomez-Polo, C.; Barmak, A.B.; Att, W.; Revilla-León, M. Influence of Implant Angulation and Clinical Implant Scan Body Height on the Accuracy of Complete Arch Intraoral Digital Scans. Journal of Prosthetic Dentistry 2022. [CrossRef]
- Ntovas, P.; Spanopoulou, M.; Martin, W.; Sykaras, N. Superimposition of Intraoral Scans of an Edentulous Arch with Implants and Implant-Supported Provisional Restoration, Implementing a Novel Implant Prosthetic Scan Body. Journal of Prosthodontic Research 2022. [CrossRef]
- Thanasrisuebwong, P.; Kulchotirat, T.; Anunmana, C. Effects of Inter-Implant Distance on the Accuracy of Intraoral Scanner: An in Vitro Study. The Journal of Advanced Prosthodontics 2021. [CrossRef] [PubMed]
- Jemt, T.; Bäck, T.; Petersson, A. Photogrammetry--an Alternative to Conventional Impressions in Implant Dentistry? A Clinical Pilot Study. International Journal of Prosthodontics 1999.



| Name | Mean (μm) | Std. Deviation (μm) | P Value |
|---|---|---|---|
| Position 35 | 10.65 | 6.32 | <000.1 |
| Position 33 | 13.34 | 11.51 | <000.1 |
| Position 31 | -3.00 | 4.89 | <000.1 |
| Position 41 | 18.95 | 5.57 | <000.1 |
| Position 43 | 26.02 | 7.94 | <000.1 |
| Position 45 | 2.48 | 6.69 | <000.1 |
| Position | N complete | Mean corr to others | Max corr to other | Max corr partner | Mean abs diff to others | Best linear R2 | Best linea partner |
| Position 45 | 20 | 0.09 | 0.56 | Position 35 | 14.39 | 0.31 | Position 35 |
| Position 43 | 20 | 0.08 | 0.37 | Position 33 | 18.28 | 0.14 | Position 33 |
| Position 33 | 20 | -0.07 | 0.37 | Position 43 | 14.08 | 0.14 | Position 43 |
| Position 35 | 20 | -0.07 | 0.56 | Position 45 | 12.08 | 0.31 | Position 45 |
| Position 31 | 20 | -0.07 | -0.41 | Position 35 | 18.10 | 0.17 | Position 35 |
| Position 41 | 20 | -0.10 | -0.28 | Position 31 | 13.67 | 0.08 | Position 31 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).