Averting Potential Misinterpretations and Diagnostic Misapplications of Potentially Misleading Laboratory Results

Submitted:

25 June 2026

Posted:

25 June 2026

You are already at the latest version

Abstract
Background: Diagnosis is a dynamical process, encompassing clinical presentation of pathophysiology, workup investigations and appropriate interpretations/integration of all data. Diagnostic accuracy is expected when based on multiple tests/investigations. However, when diagnosis is based on a single laboratory test, considered to be fundamental and deterministic, an early test’s error could cascade and propagates, triggering unnecessary investigations, longer hospitalisation and possible diagnostic misapplications. Finding: Up to 70% of diagnoses involve laboratory tests. Immunologically based analyses (immunoassays) have two fundamental features (a) inherently high analytical error rate than other routine tests and (b) universality, affecting measurements regardless of analyte’s nature or the immunoassay’s provider. Conclusions: Averting potentially erroneous result necessitates a paradigm shift which can be made by (a) intuitive use of a statistical paradigm (Bayesian reasoning) which will be explained by example and without equations and (b) appropriate and more use of follow up confirmatory tests available in all hospital laboratories.
Keywords: 
;  ;  ;  ;  

1. Introduction

Appreciation of the long-term consequences of an early error and their impact on an evolving dynamic process has its roots in Chaos mathematic, a new branch discovered by chance in 1960’s by the mathematicians/meteorologist Edward Lorenz. Early computers at that time have limited “private” internal code memory that computes calculations. Edward Lorenz rounded “public” printed number readings from six decimal places to just three to simplify calculations assuming to be inconsequential (being one part in a thousand). To his surprise, such assumption of slight differences turned out to have catastrophic impact on long-term output forecasted by these two different methods [1]. The impact of initial/early error was subsequently described by Edward Lorenz at the annual meeting of the American association for the advancement of science in Washington 1972 in a metaphor commonly known as the “Butterfly Effect” i.e. tiny air turbulence caused by a Butterfly flapping its wings in Brazil propagate and set off a tornado in Texas. Chaos mathematic emerged as dynamic systems which can be sensitive to an initial error. The analogy to clinical diagnosis may be perceived as loose/tenuous because clinicians are intuitively aware of such concept; this problem however continued to occur with early error being overlooked, causing chaos and confusion, waste time and resources not only clinically but also forensically too. The purpose of this note is to describe (a) the clinical impact of analytical error on mis-interpretation of laboratory data by focusing on details of a specific example briefly followed by some others (b) a Bayesian approaches which could help identifying such potential errors thus help averting its adverse effects and (c) explain the underlying causes of high error rate in immunoassays and finally (d) describe follow up tests which could identify false and erroneous analytical results available in all hospital laboratories.

2. Search Strategy and Evidence Selection

This review was not conducted as a formal systematic review or meta-analysis of laboratory testing methodologies. Rather, it is a narrative review intended to highlight the relatively high frequency of analytical errors associated with immunoassays compared with other routinely performed tests in clinical biochemistry and haematology. The review incorporates illustrative case reports and clinical examples that demonstrate the widespread occurrence and potential clinical consequences of immunoassay-related errors across a range of medical conditions.
A comprehensive literature search was undertaken using PubMed, MEDLINE, and Scopus databases, supplemented by manual screening of reference lists from relevant publications. The review primarily considered peer-reviewed articles published in English between January 2000 and December 2025. However, selected publications published before 2000 were also included when deemed particularly relevant to the topic. Search terms included combinations of the keywords immunoassay errors, immunoassay interference, misinterpretation of immunoassay results, misleading immunoassay results, analytical errors, and wrong diagnosis. Articles were selected based on their relevance to the occurrence, mechanisms, clinical implications, and diagnostic consequences of immunoassay-related analytical errors.

3. Clinical Impact of an Early Error

The impact of an early error on diagnosis may be best illustrated (i) by describing the confusion caused by analytical laboratory errors in investigating protracted/persistent hypoglycaemia of unknown origin, in non-diabetic patients and (ii) other analytical errors of immunoassays affecting other analytes and their consequences.

3.1. Hypoglycaemia of Unknown Origin in Non-Diabetic Patients

Current practice involves taking a blood sample during the hypoglycaemic phase for the measurement of insulin and C-peptide. Initial finding of high C-peptide concentrations associated with high insulin levels during hypoglycemia suggests endogenous source e.g. insulinoma or hyperinsulinemic hypoglycemia. Furthermore, an undetectable/ low C-peptide associated with high insulin levels raises suspicions of exogenous insulin administration i.e. factitious hypoglycemia. A molar ratio of insulin/C-peptide > 1.0 supports such interpretation [2] (physiological setting, molar ratio is ≤0.2).
Extending the use of C-peptide as an index of endogenous pancreatic secretion from diabetics to non-diabetic with undetermined cause of hypoglycaemia is simplistic, confusing and could be misleading. For example, the variability of C-peptide levels in pathologies is demonstrated in the unique study of a Dutch case with hypoglycaemia [3] in whom blood samples were taken every 3 h for 48 h (total 17 samples). Expected fluctuations in serum Insulin concentrations in response to meals occurred but levels remained very high throughout. In 10 of the seventeen samples however, C-peptide concentrations were within reference range yet were undetectable in seven other samples which would have been suggestive of exogenous insulin administration if a single blood sample was taken for analysis during any of these times. Confirmatory tests showed a high titre of insulin autoantibodies (IAA) which bind insulin, confirming the diagnosis of insulin autoimmune syndrome (IAS) a condition also known as Hirata’s disease.
Hirata’s disease (IAS) is a unique autoimmune disorder in which endogenously produced autoantibodies bind insulin (IAA). This IAA has a double whammy effects, causing hypoglycaemia and high insulin results, with normal or low/undetectable C-peptide. This condition was first discovered in a Japanese adult by Yukimasa Hirata. It was initially published in Japanese in J Jpn Diabetes Soc in 1970 [4] and subsequently in English in Tohoku Journal of Experimental Medicine in 1972 [5]. The IgG classes of IAA have a long t1/2 of approximately 3–4 weeks. Of interest also, the first case of a newborn with hypoglycaemia caused by IAA was discovered and reported around the same time by Nakagawa and published in 1973 [6]. The newborn was a Japanese baby who had protracted hypoglycaemia and high IAA titre (IgG class), transferred during pregnancy from the mother (secondary IAS). Surprisingly, however, the baby’s mother (25 years old) did not suffer from any hypoglycaemic episodes, yet had the same high titre of IAA (IgG class) as well as extremely high serum insulin levels. This highlighted the wide variation of symptoms and insulin measurements caused by IAA endogenous autoantibodies. It is now recognised that IAS is common in individuals with human leukocyte antigen [2,7] (HLA) types such as DR4, DRB1∗ 0406, DRB1∗ 0403, DQB1∗ 0302, DQA1∗ 0301, DRB1∗ 0415, and DRB1∗ 1301. The three major triggers of IAS in these predisposed individuals [2,7] are drugs, presence of autoimmune disease(s) and viral infection/reinfection, e.g. mumps, rubella, Coxsackie B influenza, hepatitis C, chickenpox and measles. The innate immune response to infection/reinfection normally triggers autoantibodies production by B-cells which rise exponentially (i.e. increase slowly at first followed by rapid rise, doubling every few hours). Drugs, especially those containing a sulphydryl (thiol) group or which produce this structure during metabolism, could also trigger IAS; examples are methimazole, pyritinol, glutathione methionine, 2-mercaptopropinoyl glycine, captopril, hydralazine, omeprazole, gliclazide and clopidogrel, and the OTC drugs α-lipoic acid (antioxidant). Vitamin B7 (biotin) used to improve hair and nails interferes with insulin and C-peptide in some immunoassays.
However, the most noteworthy of all causes is α-lipoic acid (ALA) being a drug freely available over the counter (OTC) [8]. Its nutraceutical use is to boost concentration of the endogenously produced ALA [9,10,11,12]. The amount of ALA presents in diet is low, covalently bound and not readily available. The rationale for ALA supplementation in “health-conscious” individuals is based on its favourable role as an exceptional antioxidant because of its unique solubility in water and lipids, hence its efficacy as a universal free radical scavenger, a reducer of oxidative stress and as a key catalytic agent for oxidative decarboxylation of two enzymes critical to the citric acid cycle namely, pyruvate dehydrogenase and α-ketoglutarate, through which nutrients turn into energy in mitochondria, the power house. ALA is an excellent detoxifier of metal such as copper and is also known to prolong the t1/2 of vitamin E (also antioxidant) and vitamin C. ALA is available in doses up to 600 mg or as a component with other vitamins and minerals [9].
Therapeutically, ALA is prescribed for the treatment of neuropathic pain, common in diabetic patients as well as for some neurological disorders, autoimmune diseases, vasculitis, carpal tunnel syndrome et cetera [12,13,14]. ALA’s therapeutic potential in reducing oxidative stress and chronic inflammation continues to grow [12]. For example, ALA is promoted by some in the management of high risk pregnancies to reduce the risk of miscarriage in the first trimester [15]. Its obstetric use is based on the desirable qualities of ALA in reducing pro-inflammatory cytokines (IL-1ß, IL-6, IL-8 and IL-17) while increasing the production of anti-inflammatory cytokine IL-10 [15], and decreasing the production of prostaglandin E2, ALA is widely advertised on UK infertility websites, and recommended in online IVF forums and in books. ALA alone or in combination with others moieties such as coenzyme Q10 (ubiquinone/ubiquinol also known as a potential trigger of IAA production) [8,16,17,18] has been claim to improve fertility*, reduces insulin resistance in women suffering from polycystic ovarian syndrome (PCOS), endometriosis (with N-acetyl cysteine and bromelain), infertile obese women, older women, and women with early ovarian ageing.
Haematological disorders (monoclonal gammopathy of undetermined significance (MGUS)], or multiple myeloma) may produce immunoglobulins which could bind insulin, causing hypoglycaemia like IAS. However, IAS has occurred in some cases without any of the known risk factors [19,20]. Patients with other autoimmune disorders are also known to be prone to developing IAS.
The incidence of Hirata’s disease (IAS) from all causes is undoubtedly much higher in East Asians than Caucasians, attributed to the prevalence of risk alleles in this population [2,7]. Nevertheless, it is important point out that the first IAS case in a Caucasian was a Norwegian man and published in 1972 i.e. the same year in which Hirata published the first Japanese case in English [21a]. A high number of IAS cases continued to be reported in Japanese and East Asians, with relatively few in Caucasians. For example, the first Dutch woman (Caucasian) was described in 1996 [3], while in the UK, the first case was reported as an abstract in 2010 in a patient from East Asian background, the first British Caucasian case in a native Irish in 2018 [21] and in a Russian in 2020 [22]. The first case of IAS in an Italian (Caucasian) appeared in Sicily (endogenous population < 5 million) in 2011, attributed to α-lipoic acid. In less than 2 years, six more cases of IAS were identified by the same medical centre in Sicily also caused by α-lipoic acid, a drug being available over the counter (OTC) [23]. It may be therefore reasonable to assume that the exact incidence of IAS in Caucasians, though low, is not certain.
The adverse impact caused by initial erroneous/ misleading insulin and C-peptide measurements has been reported in hypoglycaemic cases of all ages. For example, in two cases [25,26] of children, the endocrine profiles of high serum insulin and low C-peptide legitimately raised suspicion of malicious insulin administration, prompting contact of child protection services. However, follow up confirmatory tests established the presence of IAA leading to the diagnosis of IAS in one (Insulin/C-peptide ratio 2.8) and revealed analytical interference caused by human antimouse autoantibodies (HAMA) in the other (insulin/C-peptide ratio 4.77). In a Chinese child (3 years old), initial finding of insulin/C-peptide profile has led to the diagnosis of hyperinsulinemic hypoglycemia; however belated follow up tests (OGTT) revealed the presence of IAA, thus changing the diagnosis to IAS [27]. In two other cases of secondary IAS in newborn with persistent hypoglycaemia was found to be caused by transplacental transfer of IAA from mother to fetus [6,28,29]. In a Japanese male nurse, a high insulin concentration (599 pmol/L) associated with low C-peptide (33 pmol/L) and an insulin/ C-peptide ratio of 18 has raised suspicion of exogenous insulin administration. However, a test for IAA confirmed the diagnosis of IAS [24]. In two adults with hypoglycaemia, low insulin/C-peptide molar ratios (0.2 and 0.14) suggested insulinomas which were confirmed radiologically (endoscopic ultrasound/biopsy; computed tomography); however subsequently finding of high titre of IAA confirmed the co-presence of IAS in both cases [30,31].
Hyperinsulinaemia in non-diabetics is a good example because it demonstrated that initial analytical result of elevated insulin associated with low C-peptide were not accepted at face value. Further, when followed up by tests, it has confirmed erroneous measurements. Although diagnosis was delayed and revised, it is commendable that performing follow up tests has eventually led to correct diagnosis and proper management.

3.2. Clinical Impact of an Early Error in Other Cases

More important is to emphasise the universality of the inherent errors in immunoassays, meaning the underlying epitope-paratope interaction which can occur in any analysis and irrespective of analyte’s nature. For example, initially raised oestradiol measurement by immunoassay was accepted as bona fide; this led to a patient having a hysterectomy and bilateral oophorectomy, and only when no fall in oestradiol was seen postoperatively was the sample further analysed and the original result found to be wrong [32]. Falsely high oestradiol caused mismanagement of in vitro fertilisation [33] and falsely high TSH has triggered unnecessary treatment with high doses of thyroxine for 18 months, numerous investigations and scans before the error was identified [34]. Similarly, in other cases, surgery and/or administration of chemotherapy was based on erroneous hCG measurements in blood [35,36]. Falsely elevated ACTH in a patient resulted in several invasive differential diagnostic procedures for Cushing’s disease or occult ectopic ACTH, (including inferior petrosal sinus sampling), MRI and unnecessary pituitary surgery [37]. Erroneous testosterone result instigated extensive workups including surgery for a phantom tumour producing testosterone [38]. False incongruous results were reported in troponin and B-type natriuretic peptide (BNP) in cardiac patients [39,40,41,42]. Forensically, based on non-therapeutic very high serum digoxin level by immunoassay in a baby, a Dutch paediatric nurse was accused of administering digoxin with criminal intent, convicted and sentenced for life imprisonment; however, she was exonerated six years later when repeat analysis by alternative non-immunoassay platform (LC-MS) revealed that the initial immunoassay result was erroneous. In the UK, three nurses were convicted of administering exogenous insulin administration with criminal intent and sentenced for life based on single high insulin result associated with low C-peptide, despite identical profile is known to occur by analytical interference and other pathologies.
In summary, the few example of cases described above were based on the assumption that laboratory measurements by immunoassays are sufficiently reliable, hence their acceptances at face value. The incidence of fictitious results by immunoassay varied from 0.5% in the only prospective study in which the authors emphasised it is an under-estimate and up to 4% in retrospective studies [34,43,44]. The status quo that all laboratory measurements are perceived as accurate is neither tenable nor justified. The reliability of measurements prior to workup and diagnosis warrants care and could be helped and averted by appreciating the use of Bayesian logic in the interpretation of laboratory results.
Table 1. Example of analytes measurement by immunoassays Tests by immunoassay should be marked.
Table 1. Example of analytes measurement by immunoassays Tests by immunoassay should be marked.
Example of analytes measurement by immunoassays
Tests by immunoassay should be marked
All hormones
Tumour markers, e.g. carcinoembryonic antigen, prostatic specific antigen
Specific serum proteins such as ferritin, α-fetoprotein, sex hormone binding globulin, immunoglobulins
Cardiac biomarkers such as troponin, BNP and CK-MB
Vitamin D, B12/folic acid
CRP, cytokines
Rheumatoid factor; ANA, allergy and allergen-specific IgE
Specific antibodies against bacteria/viruses, e.g. hepatitis, HIV, cytomegalovirus, rubella, syphilis, covid-19 antibody and antigen.
Anti-endocrine gland antibodies, e.g. thyroid peroxidase, thyroglobulin, intrinsic factor, adrenal
Therapeutic drug monitoring such as digoxin, gentamicin, cyclosporine
Drugs of abuse, e.g. cannabis and opiates

4. Identifying Potentially Inaccurate Results; A Bayesian Logic

Probabilistic Bayesian reasoning is a statistical concept essential for assessing confidence in immunoassay results. When interpreting these results, it is important to consider the incidence/prevalence of potential underlying pathologies. Bayes’ Theorem provides a framework for addressing this issue by allowing comparison of the relative probability of different possible explanations for an abnormal laboratory result [45]. The following offers a simplified and intuitive overview underpinning Bayesian reasoning, focusing on the principles needed for result interpretation without relying on mathematical equations.
Bayesian reasoning will be illustrated using a contemporary example of COVID-19 test encountered and employed during the 2020–2021 pandemic. The test used has analytical accuracy of 98% when it was applied both to symptomatic hospitalized patients in whom the incidence/prevalence of disease was high and low in asymptomatic carriers in the community [46].
Assume that the prevalence of this condition was 80% in hospitalised patients (cohort #1) but was only 1% in the population at large (cohort #2). Applying the test to 1000 hospitalised patients would correctly identify 98% of the expected 800 patients who actually have the disease i.e. 784 patients and also produce 4 false positive results (2% of the expected 200 hospitalised patients who don’t have the disease); thus the vast majority of test results in this cohort are accurate, and the probability that a false/positive test result is approximately 0.5% (4/788).
However, when the same test is applied to 1000 individuals in the community (cohort #2) where the incidence/prevalence is 1%, the same laboratory test would correctly identify the ~10 asymptomatic carriers of the disease but also produce approximately 20 false positive results (2% of the expected 990 individuals who don’t have the disease), so in this cohort, approximately two thirds of positive laboratory results are false/inaccurate. In Fact, even if an immunoassay has 100% sensitivity (ability to detect the condition under investigation when present) and 99.5% specificity (exclude this condition when absent), a significant number of positive test results (~33%) would still be false/inaccurate in this situation.
The probability that a crucial test could be false positive should be considered when the incidence/prevalence of the medical condition is low. In fact, false negative are more common when the incidence/prevalence of the disease is high, being 2% in the above example (16 false negatives in the 800 who have the disease, cohort #1) but very small when the disease low (2% of 10 individuals with disease in cohort #2). Even if an immunoassay has 100% sensitivity (ability to detect the condition under investigation when present) and 99.5% specificity (exclude this condition when absent), a significant number of results (33.3%) would still be false/inaccurate in this situation.

5. Analytical, Current State

Routine laboratory biochemical and haematological tests, such as U&E, LFTs, bone profile, lipids and FBC et cetera can be trusted and interpreted at face value because most errors are preanalytical. Common examples are, poor phlebotomy practice i.e. withdrawing blood after prolonged period of venous stasis with tourniquet in situ (> 1 min), causing haemoconcentration, increasing all macromolecules and analytes bound to macromolecules; delays in separating serum/plasma from cells, this form of preanalytical error occurs when blood is taken and not sent to the laboratory; detrimental effect of refrigerating blood for U&E tests which could increase plasma/serum potassium levels (without haemolysis) by impeding the red-cell sodium-potassium pump, repeat freeze and thawing of stored plasma/serum samples in which analytes are measured by immunoassays [47,48,49,50]. The above examples of preanalytical errors can’t be detected or suspected by the laboratorians or clinicians yet could be easily avoidable.
All laboratory results have reference ranges typically established by defining cut-off values that encompass 95% of measurements obtained from a healthy population. As a result, a proportion of results will fall outside the reference intervals; this inherent limitation of statistical truncation generates measurable false-positive and false-negative outcomes, the probabilities of which can be quantified through predictive values derived from the established 2 × 2 contingency table [51]. Inherently high error rate of immunologically based tests such as immunoassays is not instigated by statistical truncation, but by the inherent nature of immunological epitope-paratope interactions (not reactions). Errors in immunoassay are intrinsic, unpredictable, variable, random and insidious.

6. The Underlying Cause(s) of High Error Rate in Immunoassays

A brief background may help appreciating the current role immunoassays in laboratory measurements. The discovery of immunoassay as an analytical tool came about when Solomon Berson (physician) and Rosalyn Yalow (physicist), in the mid-1950s, recognized the unusual binding of labelled insulin in the serum of some patients receiving bovine/porcine insulin treatment. They also noted that labelled insulin which bound to these endogenously produced anti-insulin antibodies in the gamma region was displaced when unlabelled insulin was added. Such a fundamental observation heralded the birth of competitive immunoassay subsequently used to measure reliably insulin only in patients free from endogenous insulin binding antibodies. In fact, recognising inherent fallibility of immunoassay results caused by interacting endogenous antibodies with assay’s reagents is as old as the technique itself. The discovery of immunoassay by these two eminent scientists was awarded the Nobel Prize in 1977 to Rosalyn Yallow because Solomon Berson has died.
Immunoassay design evolved with the development of two-site excess reagent immunometric assays, i.e. labelled antibody rather than antigen. Polyclonal antibodies used as reagents are replaced by monoclonal, antibodies and non-isotopic labels such as ruthenium have replaced labelling by radioactive iodine. Analytical interference from endogenously circulating antibodies has been reported to adversely affect the accuracy of measurements in both competitive and immunometric assays, but the latter is more prone to this phenomenon. Immunoassay has proved to be such a successful technique that over the past four decades the demand for tests has been exponential. This requirement has been accommodated by the development of fully automated, highly reliable, well-engineered analysers to which immunoassay methods were adapted. Immunoassay is now the largest single technology in the in vitro diagnostic (IVD) market value 2023 of 31.3 billion USD, forecasted by Global Market Insights in their 2024 report to rise to 49.6 billion USD by 2032.
Immunological interactions are fallible, occurring clinically in vivo, manifesting as an autoimmune disease. In a recent study involving 22 million UK individuals, at least one autoimmune disease was found in 10% of the population [52]. Fallibility in immunoassay measurements in vitro could occur in any immunoassay test irrespective of its nature and/or format.
Reagents, standards and software’s for calculating results are analyser-specific, eliminating any input by the clinical laboratory in determining assay methodology. The excess-reagent immunometric assay design, coupled with reliable timing/pipetting devices, allows a non-equilibrium end point to be used. The binding reaction under these conditions follows pseudo-first-order kinetics, with anti-body concentrations remaining in excess. The outcome of this formulation is a menu of assays characterized by a short assay time, excellent precision, a wide working range, increased sensitivity and exceptional repeatability. This allows tests to be carried out in singleton, which would have been unacceptable with early manual methods, thereby containing the cost of analyses. However, such clearly favourable characteristics have overshadowed concerns about interference from circulating antibodies in some patients’ sera which continued to be reported. In addition, some report has minimised the seriousness of the problem or dismisses its significance altogether [52a].
Errors in immunoassay caused by the presence of analytical interfering endogenous antibodies may be transient (i.e. for months following infection, immunisation, allergic reactions, blood transfusion, therapy with monoclonal antibodies et cetera) or permanent (e.g. in autoimmune disease).
Erroneous measurement in immunoassays leading to inaccurate results is generally unique to individuals who may fortuitously have endogenous immunoglobulin antibodies and/or other moieties such as biotin/vitamin B7, capable of cross reacting and interfering with reagents used in immunoassay analysis or signalling transduction. Each immunoassay ‘host’ presents his/her own antibody(s) as interacting ‘analytical reagents'. Because of the huge array and diversity of immunoglobulin antibodies that may be endogenously produced (around 10 billion), this form of potential interference is impossible to predict a priori being confined to specific patient’s sample nor it could be detected by the most stringent internal or external quality control schemes [51]. Research over the last two decades has shown immunoassay error rates ranging from 0.5–4%.

7. Follow Up Laboratory Tests to Detect Inaccurate/Erroneous Results

Simple and available follow up tests are(i) serial doubling dilutions (ii) polyethylene glycol (PEG) precipitation (iii) repeat analyses used different platform and (iv) Addition of native non-immune serum or heterophilic blocking antibodies tubes which is commercially available (HBT). Other tests such as liquid-chromatography mass-spectrometry are excellent but not widely available in routine hospital laboratories. Aberration in any single tests invalidate the measurement’s accuracy.
(i) Serial doubling dilutions
Serial dilution of a sample to concentrations of 1:2; 1:4; 1:8 with assay diluent prior to analysis assesses the accuracy of analyses. The doubling dilutions test has the attraction of being simple, could be performed by current automatic analysers and is relatively inexpensive. In this test, the behaviour of the analyte under consideration is mathematically compared with the behaviour of the results obtained in patients free from endogenous interfering antibodies [34]. This test however has limitations because the test could only detect inaccurate results by non-linearity/non-parallelism or even reverses linearity [34,53] in only 60% of cases. Doubling dilutions is therefore valuable only when non-linearity/non parallelism is detected hence the need for additional test if the results are not abnormal.
(ii) Polyethylene glycol (PEG) precipitation test
PEG 6000 at 12.5% final concentration precipitates ~100% of IgM and IgG subclasses and 70% of IgA. Analysis of normal samples (controls) treated with PEG produce similar concentrations in the supernatant (≤10 % reduction) while samples with interfering autoantibodies produce levels usually with >20 % reductions [54,55].
(iii) Repeat analysis using different platform
Repeat analysis using different immunoassay platform is commonly used. However, , it is paramount to be initially aware of the ‘biases between these two methods [54]. For example, if method A has an established positive bias of 25% to method B (not uncommon in some immunoassays), it would be reasonable to expect the numerical value obtained by method A to be higher than that obtained by method B. If method A gave a result 25% lower than the method B result, it would highlight that repeat analysis has revealed that something is odd, such as interference in the measurement and invalid measurements (e.g., endogenous antibodies). Even if method A gave an identical result to method B, such repeat should still raise concerned. Essentially, aberration of biases is among the telltale signs of analytical interference caused by the presence of endogenous antibodies. Failure to take method bias into account and/or failure to establish any method bias prior to clinical or forensic use could invalidate the utility and interpretation of utility of repeat analysis using different immunoassay platform. Repeat analysis by another method must always be objectively assessed by taking the known bias into account. It is important not to use results obtained on repeats even if it appear plausible [34].
(iv) Addition of native non-immune serum or blocking antibodies reagent
Another commonly used alternative test is to repeat measurement before and after the addition of native non-immune serum or using the more convenient but expensive, commercially available blocking antibodies tubes (HBT) [54]. The utility of this test assumes that non-immune sera have a range of immunoglobulins, which by sheer chance may interact and neutralize endogenous interfering antibodies. Significant difference in results before and after the addition of nonimmune serum would be indicative of the presence of interference and false results. However, the utility of this test is marginal when used in conjunction with others, has a marginal effect on increasing the detection rate from interfering antibodies (3%). A better rate (20%) of increase in the detection of interference and inaccurate results can be achieved by using blocking antibodies, which increase the chance of neutralizing endogenous interfering antibodies.
In summary, attention is paramount to (a) proper application of follow up confirmatory tests and (b) their interpretation.

8. The Way Forward

Advances in informatics and digital transmition of data electronically from analysers to laboratory information system (LIS) and after validation to patient’s electronic health record (EHR) have been introduced in most health trusts including the UK. This creates a seamless, automated flow of diagnostic information into the patient’s digital record, thus reducing post-analyses transcription errors, enhances and speed timely accessibility [56,57,58,59].
Interoperability by extending algorithms in the future could highlighting and integrate additional useful information such as incidence/prevalence of the disease for which the test is used; medications (prescribed and over the counter) which have the potential to influence laboratory analyses. These are examples which could augment the effectiveness and quality of interpretations and avert potential diagnostic misapplications by clinical practitioners. Meanwhile, in the absence of embedded patient’s electronic health care records, considerable attention is warranted when diagnosis is determined by result of a single unverified measurement. It also makes follow up tests for falsifications and/or of additional surrogate investigations a sine qua non before deterministic diagnosis is made.
Table 2. Take home message.
Table 2. Take home message.
Take home message
(1) Routine biochemical and haematological tests are analytically robust. Almost all errors are preanalytical and avoidable.
(2) Immunoassays are widely used for measurements of numerous analytes. Despite their analytical high error rate by immunoassay, it is here to stay.
(3) Interpretation of immunoassay results must consider (a) accuracy of analysis (~98%) and (b) incidence/prevalence of disease for which the test is used. These considerations could identify potential erroneous and misleading immunoassay results avert misinterpretations, unnecessary investigations and potential diagnostic misapplications.
(4) Essentially false positive test is excessive when the incidence/prevalence of disease for which the test is used is low. False negative results are more common when the incidence/prevalence of the disease is high.
(5) Interoperability by extending algorithms could alert both clinicians and laboratorians to the need of follow up confirmatory tests of some immunoassay measurements.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

I wish to thank Dr Hilde Wilkinson-Herbots associate professor of statistics at University College London for discussing aspects of Bayesian paradigm.

Conflicts of Interest

The author states that he has been an author, reviewer to subject related to this review, provided opinion pro bono to solicitor at Newcastle, UK.

References

  1. Lorenz, E. N. Deterministic non-periodic flow. J. Atmos. Sci. 1963, 20, 130–41. [Google Scholar]
  2. Censi, S.; Mian, C.; Betterle, C. Insulin autoimmune syndrome: from diagnosis to clinical management. Ann. Transl. Med. 2018, 6, 335–40. [Google Scholar] [CrossRef]
  3. Schlemper, R.J.; Uchigata, M.; FrSlich, A.; Vingerhoeds, C.M.; Meinders, A.E. Recurrent hypoglycemia caused by the insulin autoimmune syndrome: the first Dutch case. Neth. J. Med. 1996, 48, 188–92. [Google Scholar] [PubMed]
  4. Hirata, Y.; Ishizu, H.; Ouchi, N. Insulin autoimmunity in a case of spontaneous hypo-glycemia. J. Jpn. Diabetes Soc. 1970, 13, 312–320. [Google Scholar] [CrossRef]
  5. Hirata, Y.; Ishizu, H. Elevated insulin-binding capacity of serum proteins in a case with spontaneous hypoglycemia and mild diabetes not treated with insulin. Tohoku J. Exp. Med. 1972, 107, 277–286. [Google Scholar] [CrossRef] [PubMed]
  6. Nakagawa, S.; Suds, N.; Kudo, M.; Kawaski, M. in1973. A new type of hypoglyeaemia in a newborn infant. Diabetologia 1973, 9, 367–75. [Google Scholar] [PubMed]
  7. Ismail, A. A. A. The insulin autoimmune syndrome (IAS) as a cause of hypoglycaemia: an update on the pathophysiology, biochemical investigations and diagnosis. Clin. Chem. Lab Med. 2016, 54, 1715–1724. [Google Scholar] [CrossRef] [PubMed]
  8. Yu, X.; Li, M.; Liao, Y.; Xie, Y.; Xu, J.; Long, Y.; Xiang, S. Drug-induced insulin autoimmune syndrome: a clinico-epidemiological analysis integrating pharmacovigilance data and case series. Diabetol. Metab. Syndr. 2025 17, 9 387. [Google Scholar] [CrossRef] [PubMed]
  9. Revankar, V.; Lakhpatia, P.; Kelkar, S. Hypoglycemia and Multivitamins. J. Assoc. Physicians India 2024, 72, 99–100. [Google Scholar] [CrossRef]
  10. Capece, U.; Moffa, S.; Improta, I.; Di Giuseppe, G.; Nista, E. C.; et al. Alpha-Lipoic Acid and Glucose Metabolism: A Comprehensive Update on Biochemical and Therapeutic Features. Nutrients 2023, 15, 18. [Google Scholar] [CrossRef] [PubMed]
  11. Tripathi, A. K.; Anup Kumar Ray, A. K.; Sunil Kumar Mishra, S. K.; S, M.; Mishra, H.; Khurana, A. Molecular and Therapeutic Insights of Alpha-Lipoic Acid as a Potential Molecule for Disease Prevention. Rev. Bras. Farmacogn. 2023, 33, 272–87. [Google Scholar] [CrossRef] [PubMed]
  12. Carnib, B. L.; Souza, E. V.; Floresta, L. R. S.; Lage, T. M.; Pedro, I. D. R.; Muniz, F. C.; Silva, A. C. A.; Oliveira, J. M. eTherapeutic applications of alpha-lipoic acid: A review of clinical and preclinical evidence (1998–2024). 2025, 191.118480. [Google Scholar] [CrossRef] [PubMed]
  13. AbuBaha, M.; Salameh, H.; AbuBaha, B.; Dahabreh, Y.; Marouf, O.; et al. Unmasking Hirata: a mysterious case of Hypoglycemia triggered byimmunologic storm. Oxf. Med. Case Rep. 2026, 1, 46–50. [Google Scholar] [CrossRef] [PubMed]
  14. Viana, M. D. M.; Lauria, P. S. S.; de Lima, A. A.; Opretzka, L. C. F.; et al. Alpha-Lipoic Acid as an Antioxidant Strategy for Managing Neuropathic Pain. Antioxidants 2022, 11, 2420. [Google Scholar] [CrossRef]
  15. Petca, A.; Bot, M.; Maru, N.; Calo, I. G.; Borislavschi, A.; et al. Benefits of α-lipoic acid in high-risk pregnancies (Review). Experim Ther. Med. 2021, 22. [Google Scholar] [CrossRef] [PubMed]
  16. Di Tucci, C.; Di Feliciantono, M.; Vena, C.; Capone, C.; Schiavi, M. C.; Pietrangeli, D.; et al. Alpha lipoic acid in obstetrics and gynecology. Gynec Endocrinol. 2018, 34, 729–33. [Google Scholar] [CrossRef]
  17. Shang, Y.; Song, N.; He, R.; Wu, M. Antioxidants and Fertility in Women with Ovarian Aging: A Systematic Review and Meta-Analysis. Adv. Nutr. 2024, 15;15, 100273. [Google Scholar] [CrossRef] [PubMed]
  18. Parente, E.; Colannino, G.; Ferrara, P. Efficacy of Magnesium and Alpha Lipoic Acid Supplementation in Reducing Premature Uterine Contractions. Open J. Obstet. Gynecol. 2014, 4, 578–83. [Google Scholar] [CrossRef]
  19. Lin, M.X.; Chen, Y.H.; Ning, J. Insulin Autoimmune Syndrome: A Systematic Review. Intern J. Endocrinol. 2023, ID 1225676. [Google Scholar] [CrossRef] [PubMed]
  20. Kumar, V.; Gala, D.; Rafi, I.; Shah, M.; Marowa, S.; et al. Autoimmune hypoglycemia with anti-insulin autoantibodies in an eighty-one year old woman without apparent risk factor. J. AACE 2023. [Google Scholar] [CrossRef]
  21. Følling, I.; Norman, N. Hyperglycemia, hypoglycaemic attacks, and production of anti-insulin antibodies without previous known immunization. Immunological and func-tional studies in a patient. Diabetes 1972, 21, 814–826. [Google Scholar] [CrossRef] [PubMed]
  22. Hunter, A.; Graham, U.; Lindsay, J.R. Insulin autoimmune syndrome: a rare case of hypoglycaemia resolving with immunosuppression. Ultster Med. J. 2018, 87, 34–37. [Google Scholar]
  23. Yukina, M.; Nuralieva, N.; Solovyev, M.; Troshina, E.; Vasilyev, E. Insulin autoimmune syndrome. Endocrinol. Diabetes Metab. Case Rep. 2020, 19–0159. [Google Scholar] [CrossRef] [PubMed]
  24. Gullo, D.; Evans, J.L.; Sortino, G.; Goldfine, I.D.; Vigneri, R. Insulin autoimmune syndrome (Hirata disease) in European Caucasians taking alpha-lipoic acid. Clin. Endocrinol. 2014, 81, 204–209. [Google Scholar] [CrossRef] [PubMed]
  25. Okumura, H.; Inaba, S.; Kawashima, A.; Shimizu, T. Insulin autoimmune syndrome: a case report highlighting the diagnostic pitfalls. Cureus 2024, 16, e64130. [Google Scholar] [CrossRef] [PubMed]
  26. Dos Santos, T.J.; Passona, B.C.G.; Ybarra, M.; Ito, S.S.; Teles, M.G.; Manna, T.D.; et al. Pitfalls in the diagnosis of insulin autoimmune syndrome (Hirata’s disease) in a hypoglycemic child: a case report and review of the literature. J. Pediatr. Endocrinol. Metab. 2019, 32, 421–8. [Google Scholar] [CrossRef] [PubMed]
  27. Craven, M.; Lord, K.; Leavens, K. F.; D. De Leon, D. Insulin Immunoassay Interference Due to Human Antimouse Antibodies in a Patient With Ketotic Hypoglycemia. J. Clin. Endocrinol. Metab. Case Rep. 2023, 1. [Google Scholar] [CrossRef] [PubMed]
  28. Cheng, M.; Ding, Y.; Wang, D.; Gong, C. Insulin autoimmune syndrome in a 3-yearold boy: the youngest to date in China and a narrow review. BMC Pediatr. 2025, 25, 94–101. [Google Scholar] [PubMed]
  29. Perri, A.; Fattore, S.; Sbordone, A.; Viti, L.; Pitocco, D.; Vento1, G. Secondary Hirata syndrome in a neonate: practical approach and management. J. Clin. Endocrinol. Metab. Case Rep. 2024, 2, luae109. [Google Scholar] [CrossRef]
  30. Tartaglione, L.; Rizzi, A.; Perri, A.; Mazzotta, F.; De Carolis, S.; Vento, G.; Lanzone, A.; Pitocco, D. A case of Hirata syndrome in pregnancy induced by alpha lipoic acid: diagnosis and management. AACE Endocrinol. Diabetes 2025. [Google Scholar] [CrossRef] [PubMed]
  31. Iqbal, A.; Broome, D.T.; Makin, V.; Yogi-Morren, D. Insulinoma with Concomitant Insulin Antibodies. Insulinoma with concomitant insulin antibodies. AACE Clin. Case Rep. 2021, 7, 247–8. [Google Scholar] [PubMed]
  32. Nakajima, R.; Sato, D.; Togashi, I.; Idesawa, H.R.; Sato, D.; Togashi, I.; et al. Insulinoma presenting with anti-insulin antibodies. Endocrinol. Diabetes Metab. Case Rep. 2024, 12, 24–0062. [Google Scholar]
  33. Ismail, A. A. A.; Barth, J. H. Wrong biochemistry results. BMJ 2001, 323(7315), 705–706. [Google Scholar] [CrossRef] [PubMed]
  34. Anckaert, Ellen; Platteau, Peter; Schiettecatte, Johan; Smitz, Johan; et al. Spuriously elevated serum estradiol concentrations measured by an automated immunoassay rarely cause unnecessary cancellation of in vitro fertilization cycles. Fertil. Steril. 2006, 85, 1822.e5–8. [Google Scholar] [CrossRef] [PubMed]
  35. Ismail, A. A. A.; Walker, P. L.; Barth, J. H.; Lewandowski, C.; Jones, R.; Burr, W. A. Wrong biochemistry results: two case reports and observational study on 5310 patients on potentially misleading thyroid stimulating hormone and gonadotropin immunoassay results. Clin. Chem. 2002, 48, 2023–29. [Google Scholar] [CrossRef] [PubMed]
  36. Cole, L.A.; Rinne, K.M.; Shahabi, S.; Omrani, A. False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. Clin. Chem. 1999, 45, 313–314. [Google Scholar] [PubMed]
  37. Rotmensch, S.; Cole, L.A. False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotrophin concentrations. Lancet 2000, 355, 712–715. [Google Scholar] [CrossRef] [PubMed]
  38. Greene, L. W.; Geer, E. B.; Page-Wilson, G.; Findling, J. W.; Hershel Raff, H. Assay-Specific Spurious ACTH Results Lead to Misdiagnosis, Unnecessary Testing, and Surgical Misadventure—A Case Series. J. Endocr. Soc. 2019, 3, 763–72. [Google Scholar] [CrossRef] [PubMed]
  39. Stieglitz, H.M.; Korpi-Steiner, N.; Katzman, B.; Mersereau, J. F.; Styner, M. Suspected testosterone-producing tumor in a patient taking biotin supplement. J. Endocr. Soc. 2018, 2, 563–569. [Google Scholar] [CrossRef]
  40. Murryam, S.; Cook, P.; Ellis, S. The false positive troponin results: case studies of analytical interference. Clin. Med. (Lond) 2022, 22, 87–88. [Google Scholar] [CrossRef] [PubMed]
  41. Walters, C. M. L.; Chetty, R.; Tanner, M. J.; McQuillan, B. M. False-positive cardiac troponin in clinical practice: causes, assessment and implications. Cardiol. Today 2025, 15, 68–73. [Google Scholar]
  42. Yin, Q.; Wang, F.; Zhang, C.; et al. Case report: false-positive B-type natriuretic peptide results with the cyclic amplified fluorescence immunoassay. J. Int. Med. Res. 2025, 53, Publlish online. [Google Scholar] [CrossRef] [PubMed]
  43. Li, S.; Yao, J. Systematic identification of human anti-mouse antibody interference causing falsely elevated B-type natriuretic peptide: A case study. Ann. Clin. Biochem 2026. [Google Scholar] [CrossRef]
  44. Ghazal, K.; Barbant, S.; Prie, D.; Piketty, M.-L. Hormone immunoassay interference: Ann Lab Med. 2022, 42, 3–23. [Google Scholar] [CrossRef] [PubMed]
  45. Wauthier, L.; Mario Plebani, M.; Favresse, J. Interferences in immunoassays: review and practical algorithm. Clin. Chem. Lab Med. 2022, 60, 808–820. [Google Scholar] [CrossRef] [PubMed]
  46. Ismail Adel, A. A.; Ismail Abbas, A.; Ismail, Y. Probabilistic Bayesian reasoning can help identifying potentially wrong immunoassays results in clinical practice: Even when they appear ‘not-unreasonable’. Ann. Clin. Biochem 2010. [Google Scholar] [CrossRef] [PubMed]
  47. Ismail, A. A. A. Serological tests for COVID-19 antibodies: Limitations must be recognized. Ann. Clin. Biochem 2020, 57, 274–76. [Google Scholar] [CrossRef] [PubMed]
  48. Bonini, P.; Plebani, M.; Ceriotti, F.; Rubboli. Errors Lab. Med. Clin. Chem. 2002, 48, 691–698.
  49. Moore, D.; Walker, P. L.; Ismail, A. A. A/ The alteration of serum potassium levels during sample transport. The Practitioner 1989, 233, 395–7. [Google Scholar] [PubMed]
  50. Master, P. W.; Ismail, A. A. A.; Gourlay, N.; McArthur, C. BMJ 1997, 315, 190. [CrossRef] [PubMed]
  51. Ismail, A. A. A. The effects of repeated freeze–thaw cycles on endocrine parameters in plasma and serum. Ann. Clin. Biochem 2017, 54, 622–23. [Google Scholar] [CrossRef] [PubMed]
  52. Ismail, A. A. A. When laboratory tests can mislead even when they appear plausible. Clin. Med. 2017, 17, 329–332. [Google Scholar] [CrossRef] [PubMed]
  53. Conrad, N.; Misra, S.; Verbakel, J. Y.; Verbeke, G.; Molenberghs, G.; et al. Incidence, prevalence, and co-occurrence of autoimmune disorders over time and by age, sex, and socioeconomic status: a population-based cohort study of 22 million individuals in the UK. Lancet 2023, 401(10391), 1878–90. [Google Scholar] [CrossRef] [PubMed]
  54. Dittadi, R. Interferences in immunoassay: an estimate based on ‘real-world’ experience. Ann. Clin. Biochem 2024, 61, 327–28. [Google Scholar] [CrossRef] [PubMed]
  55. Ismail, A. A. A. Detecting interference from endogenous antibodies in immunoassays by doubling dilutions test. Clin. Chem. Lab Med. 2007, 45, 851–854. [Google Scholar] [CrossRef] [PubMed]
  56. Ismail, A. A. A. On the interpretation of affirmative follow-up tests in immunoassays: what must not be done? Ann. Clin. Biochem 2006, 43, 249–51. [Google Scholar] [CrossRef]
  57. Ismail, A. A. A.; Ismail, A. A. A. Pitfalls of immunoassays for diagnosis of hypoglycemia of undetermined etiology. Clin Chem Lab Med. published online. 2025. [CrossRef]
  58. Perrotta, P. L.; Karcher, D. S. Validating Laboratory Results in Electronic Health Records: A College of American Pathologists Q-Probes Study”. Arch. Pathol. Lab Med. 2016, 140, 926–931. [Google Scholar] [CrossRef] [PubMed]
  59. Electronic reporting of all reference laboratory results: An important step toward a truly all-encompassing, integrated health record. Health Inform. J. 2016, 22, 496–504. [CrossRef] [PubMed]
  60. Bietenbeck, A.; Streichert, T. Preparing Laboratories for Interconnected Health Care”. Diagnostics 2021, 11, 1487. [Google Scholar] [CrossRef] [PubMed]
  61. Manukyan, E.; Levine, B.; Manukyan, A.; Lulejian, A. Integration of Laboratory Data into a National Electronic Health Record (EHR)”. In Studies in Health Technology and Informatics; 2023. [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.
Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

© 2026 MDPI (Basel, Switzerland) unless otherwise stated

Accessibility

Disclaimer

Terms of Use

Privacy Policy

Privacy Settings