Submitted:
10 July 2025
Posted:
15 July 2025
You are already at the latest version
Abstract

Keywords:
1. Introduction
2. Materials and Methods
3. Results
3.1. Overall Findings



4. Discussion
5. Conclusions
Author Contributions
Data Availability Statement
Acknowledgments
Conflicts of Interest
Abbreviations
| APTT | Activated partial thromboplastin time |
| APTT-HR | APTT with heparin resistant recalcifying solution |
| AXA | Anti factor Xa activity-based heparin assay |
| ATA | Anti thrombin activity-based heparin assay |
| IU/ml | International units/ml |
| ECMO | Extracorporeal membrane oxygenation |
| CABG | Coronary artery bypass graft |
| DVT | Deep Vein Thrombosis |
| PMT | Porto mesenteric thrombosis |
| RVAD.Oxy | Right vascular assist device on oxygen |
| Cardio. Mon | Cardiology monitoring |
References
- Antihepca™-HRRS. Heparin Resistant Recalcifying Solution. [Online] 2024. [Cited: 21 October 2024.] https://www.haematex.com/haematex-products/antihepca-hrrs.
- Marlar RA, Clement B, Gausman J. Activated Partial Thromboplastin Time Monitoring of Unfractionated Heparin Therapy: Issues and Recommendations. Semin Thromb Hemost. 2017; 43: 253-260.
- Favaloro EJ, Kershaw G, Mohammed S, Lippi G. How to Optimize Activated Partial Thromboplastin Time (APTT) Testing: Solutions to Establishing and Verifying Normal Reference Intervals and Assessing APTT Reagents for Sensitivity to Heparin, Lupus Anticoagulant, and Clotting Factors. Semin. Thromb Hemost.2019; 45: 22-35.
- Arachchillage DJ, Kitchen S. Pleiotropic Effects of Heparin and its Monitoring in Clinical Practice. Semin Thromb Hemost.2024; 50; 1153-1162.
- Li S, Li A, Beckman JA, Kim C, Granich MA, Mondin J, Sabath DE, Garcia DA, Mahr C. Discordance between aPTT and anti-Xa in monitoring heparin anticoagulation in mechanical circulatory support. ESC Heart Fail. 2024; 11: 2742-2748.
- van Roessel S, Middeldorp S, Cheung YW, Zwinderman AH, de Pont AC. Accuracy of aPTT monitoring in critically ill patients treated with unfractionated heparin. Neth J Med. 2014; 72: 305-10.
- Jin J, Gummidipundi S, Hsu J, Sharifi H, Boothroyd D, Krishnan A, Zehnder JL. Discordant High Activated Partial Thromboplastin Time Relative to Anti-Xa Values in Hospitalized Patients is an Independent Risk Factor for Increased 30-day Mortality. Semin Thromb. Hemost. 2024. https://doi.org/10.1055/s-0044-1789020. Epub ahead of print. PMID: 39191408.
- Bartlett R, Arachchillage DJ, Chitlur M, Hui SR, Neunert C, Doyle A, Retter A, Hunt BJ, Lim HS, Saini A, Renné T, Kostousov V, Teruya J. The History of Extracorporeal Membrane Oxygenation and the Development of Extracorporeal Membrane Oxygenation Anticoagulation. Semin Thromb. Hemost. 2024; 50: 81-90.
- Kitchen S, Adcock DM, Dauer R, Kristoffersen AH, Lippi G, Mackie I, Marlar RA, Nair S. International Council for Standardization in Haematology (ICSH) recommendations for processing of blood samples for coagulation testing. Int J Lab Hematol. 2021; 43: 1272-1283.
- Toulon P, Smahi M, De Pooter N. APTT therapeutic range for monitoring unfractionated heparin therapy. Significant impact of the anti-Xa reagent used for correlation. J Thromb Haemost. 2021,19: 2002-2006.
- Cumming AM, Jones GR, Wensley RT, Cundall RB. In vitro neutralization of heparin in plasma prior to the activated partial thromboplastin time test: an assessment of four heparin antagonists and two anion exchange resins. Thromb Res. 1986; 1; 41: 43-56.
- Newall F. Protamine titration. Methods Mol Biol. 2013; 992: 279-87.
- van den Besselaar AM, Meeuwisse-Braun J. Enzymatic elimination of heparin from plasma for activated partial thromboplastin time and prothrombin time testing. Blood Coagul Fibrinolysis. 1993; 4: 635-8.
- Exner T, Favresse J, Lesire S, Douxfils J, Mullier F. Clotting test results correlate better with DOAC concentrations when expressed as a “Correction Ratio”; results before/after extraction with DOAC Stop reagent. Thromb. Res. 2019; 179: 69-72.
- Streng AS, Delnoij TSR, Mulder MMG, Sels JWEM, Wetzels RJH, Verhezen PWM, Olie RH, Kooman JP, van Kuijk SMJ, Brandts L, Ten Cate H, Lorusso R, van der Horst ICC, van Bussel BCT, Henskens YMC. Monitoring of Unfractionated Heparin in Severe COVID-19: An Observational Study of Patients on CRRT and ECMO. TH Open. 2020; 19: 4: e365-e375.
- van den Besselaar AM, Meeuwisse-Braun J, Bertina RM. Monitoring heparin therapy: relationships between the activated partial thromboplastin time and heparin assays based on ex-vivo heparin samples. Thromb Haemost. 1990; 63:16-23.
- Aubron C, Chapalain X, Bailey M, Board J, Buhr H, Cartwright B, Dennis M, Hodgson C, Forrest P, McIlroy D, Murphy D, Murray L, Pellegrino V, Pilcher D, Sheldrake J, Tran H, Vallance S, Cooper DJ, McQuilten Z. Anti-Factor-Xa and Activated Partial Thromboplastin Time Concordance and Outcomes in Adults Undergoing Extracorporeal Membrane Oxygenation: A Secondary Analysis of the Pilot Low-Dose Heparin in Critically Ill Patients Undergoing Extracorporeal Membrane Oxygenation Randomized Trial. Crit Care Explor. 2023; 8; 5(11): e0999.
- Geli J, Capoccia M, Maybauer DM, Maybauer MO. Argatroban Anticoagulation for Adult Extracorporeal Membrane Oxygenation: A Systematic Review. J Intensive Care Med. 2022; 37: 459-471.
- Rajsic S, Treml B, Jadzic D, Breitkopf R, Oberleitner C, Bachler M, Bösch J, Bukumiric Z. aPTT-guided anticoagulation monitoring during ECMO support: A systematic review and meta-analysis. J Crit Care. 2023; 77:154332.
- Vandiver JW, Vondracek TG. Antifactor Xa levels versus activated partial thromboplastin time for monitoring unfractionated heparin. Pharmacotherapy. 2012; 32: 546-58.





| APTT | APTT-HR | Correction Ratio (CR) |
Heparin by AXA |
Heparin by ATA | FVIII | Sample Number |
Clinical notes |
| sec | sec | ratio | IU/ml | IU/ml | % | ||
| 55.9 | 35.8 | 1.56 | 0.55 | 0.39 | 187 | 5 | Palliative care |
| 58.2 | 29.5 | 1.97 | 0.84 | 0.73 | 249 | 28 | CABG |
| 65.6 | 36.1 | 1.82 | 0.63 | 0.42 | 209 | 4 | Palliative care |
| 67.1 | 36.8 | 1.82 | 0.75 | 0.39 | 225 | 74 | Post-op aneurism |
| 67.5 | 35.3 | 1.91 | 0.42 | 0.29 | 199 | 34 | CABG |
| 72.4 | 36.6 | 1.98 | 0.69 | 0.58 | 184 | 3 | Palliative care |
| 73.8 | 36.2 | 2.04 | 0.60 | 0.63 | 157 | 2 | Palliative care |
| 78.0 | 37.0 | 2.11 | 0.58 | 0.58 | 127 | 43 | DVT |
| 84.4 | 36.6 | 2.31 | 0.54 | 0.59 | 131 | 44 | DVT |
| 86.9 | 37.5 | 2.32 | 0.65 | 0.81 | 218 | 39 | CABG |
| APTT | APTT-HR | Correction Ratio (CR) | Heparin by AXA | Heparin by ATA | FVIII | Sample Number |
Clinical notes |
| sec | sec | ratio | IU/ml | IU/ml | % | ||
| 72.5 | 51.4 | 1.41 | 0.22 | 0.11 | 168 | 123 | RVAD.Oxy |
| 66.8 | 52.4 | 1.27 | 0.24 | 0.16 | 185 | 12 | ECMO |
| 63.6 | 53.8 | 1.18 | 0.19 | 0.12 | 306 | 88 | PMT |
| 77.0 | 60.4 | 1.27 | 0.04 | 0.06 | 117 | 79 | ECMO |
| 69.6 | 65.0 | 1.07 | 0.08 | 0.07 | 265 | 8 | ECMO |
| 76.1 | 68.1 | 1.12 | 0.03 | 0.10 | 122 | 80 | ECMO |
| 80.9 | 68.4 | 1.18 | 0.05 | 0.09 | 306 | 103 | Post.op |
| 95.6 | 72.1 | 1.33 | 0.07 | 0.11 | 45 | 85 | DVT |
| 103 | 74.7 | 1.38 | 0.08 | 0.09 | 203 | 87 | PMT |
| 136 | 90.7 | 1.50 | 0.07 | 0.10 | 203 | 86 | PMT |
| APTT | APTT-HR | Correction Ratio (CR) | Heparin by AXA | Heparin by ATA | FVIII | Sample number | Clinical Information |
| sec | sec | ratio | IU/ml | IU/ml | % | ||
| 37.6 | 39.1 | 0.96 | 0.06 | 0.07 | 64 | 121 | ECMO |
| 38.8 | 40.3 | 0.96 | 0.05 | 0.05 | 48 | 122 | ECMO |
| 39.4 | 40.0 | 0.99 | 0.11 | 0.10 | 127 | 51 | Post-op |
| 40.9 | 42.0 | 0.97 | 0.12 | 0.07 | 219 | 14 | ECMO |
| 46.7 | 47.0 | 0.99 | 0.08 | 0.05 | 43 | 63 | na |
| 47.3 | 50.3 | 0.94 | 0.02 | 2.47 | 56 | 33 | Argatroban |
| 49.3 | 52.9 | 0.93 | 0.07 | 0.10 | 61 | 95 | ECMO |
| 49.6 | 52.9 | 0.94 | 0.06 | 0.03 | 64 | 94 | ECMO |
| 50.6 | 54.4 | 0.93 | 0.03 | na | 59 | 32 | Cardio.mon |
| 51.8 | 56.9 | 0.91 | 0.06 | 0.08 | 76 | 97 | ECMO |
| 61.1 | 66.6 | 0.92 | 0.07 | 0.08 | 35 | 98 | ECMO |
| 63.1 | 67.4 | 0.94 | 0.07 | 0.19 | 31 | 96 | ECMO |
| 72.7 | 77.9 | 0.93 | 0.04 | 2.33 | 24 | 160 | Argatroban |
| 80.0 | 89.8 | 0.89 | 0.03 | na | 46 | 148 | Cardio.mon |
| 89.1 | 99.6 | 0.89 | 0.05 | 0.00 | 32 | 149 | Cardio.mon |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).