Acta Plane: A New Reference for Virtual Orientation of Cone Beam Computed Tomography Scans

Version 1 : Received: 14 November 2023 / Approved: 15 November 2023 / Online: 15 November 2023 (09:58:07 CET)

A peer-reviewed article of this Preprint also exists.

Sanders-Mello, F.; de Menezes, L.M.; Puetter, U.T.; Azeredo, F.; Griekspoor, T.C.A.; de Windt, S.; Livas, C.; Jonkman, R.E.G.; Rozema, F.R.; Koolstra, J.H. Acta Plane—A New Reference for Virtual Orientation of Cone Beam Computed Tomography Scans: A Pilot Study. Appl. Sci. 2024, 14, 347. Sanders-Mello, F.; de Menezes, L.M.; Puetter, U.T.; Azeredo, F.; Griekspoor, T.C.A.; de Windt, S.; Livas, C.; Jonkman, R.E.G.; Rozema, F.R.; Koolstra, J.H. Acta Plane—A New Reference for Virtual Orientation of Cone Beam Computed Tomography Scans: A Pilot Study. Appl. Sci. 2024, 14, 347.

Abstract

Introduction Cone Beam Computed Tomography (CBCT) scans should be digitally oriented using a reference plane before being evaluated for patient growth and treatment outcome. Current orientation planes are usually dependent on the Porion points. Using more reliable landmarks than the Porion, we introduce the Acta plane and investigate its reliability as an alternative reference plane for cases in which the Porion point is inaccessible. Methods To test its reliability, a dental student and an orthodontist located sixteen skeletal and dental landmarks in sixteen CBCT scans, before and after reorientation. Also, four measurements were calculated based on these landmarks’ coordinates. The reorientation of these CBCT scans with the Acta plane was done by another dental student. Intraclass Correlation Coefficient (ICC) was calculated before and after orientation, intra- and inter-examiner. The data were tested for significance through the Shapiro Wilk test with a threshold set at 0.05. Through the ICC variation of the points’ coordinates, this article also evaluated the reliability of this plane with the t-paired and exact-sign tests. Results: The identification of landmarks was more reliable in the reoriented CBCT images than in the original images, with a significant increase of 0.012 in the median of the ICC. Linear and angular measures showed no significant differences between groups. Conclusion This plane is a reliable alternative for the orientation of CBCT images. The design of the Acta plane might allow the use of a smaller field of view and, consequently, a reduction in the radiation dose.

Keywords

diagnostic imaging; cone-beam computed tomography; three-dimensional imaging; patient positioning; spatial orientation; observer variation; reproducibility of results

Subject

Medicine and Pharmacology, Dentistry and Oral Surgery

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.