Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Experimental Study on Convection and Heat Conduction Heating of Air Conditioning Bed System Under Winter Lunch Break Mode

Version 1 : Received: 4 July 2023 / Approved: 5 July 2023 / Online: 5 July 2023 (14:36:25 CEST)

A peer-reviewed article of this Preprint also exists.

Jin, J.; Duan, P.; Liu, Y.; Chen, H.; Yu, T. Experimental Study on Convection and Heat Conduction Heating of an Air-Conditioned Bed System under Winter Lunch Break Mode. Processes 2023, 11, 2391. Jin, J.; Duan, P.; Liu, Y.; Chen, H.; Yu, T. Experimental Study on Convection and Heat Conduction Heating of an Air-Conditioned Bed System under Winter Lunch Break Mode. Processes 2023, 11, 2391.

Abstract

In this paper, the experimental study of heating in 2 h lunch mode of air-conditioned bed system is carried out. The results show that the power consumption of heat conduction heating is only 0.34 kW·h, and the average heat dissipation is 81.3 W, while the power consumption of convection heating is 1.43 kW·h, with an average heat dissipation of 748.7 W. Regardless of power consumption or heat dissipation, convection heating is significantly higher than heat conduction heating, resulting in the room air temperature of the former increased from 12.3 °C to 17.3 °C, while the latter only increased from 14.4 °C to 15.2 °C. The study found that the water temperature of heat conduction heating can meet the thermal comfort needs of the human body in the range of 38~40 °C, while convection heating requires a higher temperature range, In contrast, the grade of hot water required for heat conduction heating is lower. Through the experiment, it is also found that the temperature of convection heating rises fast, but it is easy to appear dry feeling after a long time, while heat conductive heating has a slow temperature rise. there is a cool feeling within 20 min after the heating starts, and then the thermal comfort is better. The air conditioning system in this paper is used for the heating experiment in the winter lunch break mode, compared with convection heating, the overall thermal comfort of heat conduction heating is better and more energy efficient. it is suggested to adopt heat conduction heating mode in the winter heating of this system.

Keywords

air-conditioned bed system; heat conduction heating; convection heating; thermal comfort; Energy conservation

Subject

Engineering, Energy and Fuel Technology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.