Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Accuracy of Magnetometer-Guided Sentinel Lymphadenectomy after Intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles in Prostate Cancer: The SentiMag Pro II Study

Version 1 : Received: 31 October 2019 / Approved: 3 November 2019 / Online: 3 November 2019 (15:38:28 CET)

A peer-reviewed article of this Preprint also exists.

Winter, A.; Engels, S.; Goos, P.; Süykers, M.-C.; Gudenkauf, S.; Henke, R.-P.; Wawroschek, F. Accuracy of Magnetometer-Guided Sentinel Lymphadenectomy after Intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles in Prostate Cancer: The SentiMag Pro II Study. Cancers 2020, 12, 32. Winter, A.; Engels, S.; Goos, P.; Süykers, M.-C.; Gudenkauf, S.; Henke, R.-P.; Wawroschek, F. Accuracy of Magnetometer-Guided Sentinel Lymphadenectomy after Intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles in Prostate Cancer: The SentiMag Pro II Study. Cancers 2020, 12, 32.

Abstract

Targeted radioisotope-guided sentinel lymph node dissection (sLND) has shown high diagnostic accuracy in prostate cancer (PCa). To overcome the downsides of the radioactive tracers, magnetometer-guided sLND using superparamagnetic iron oxide nanoparticles (SPIONs) was successfully applied in PCa. This prospective study (SentiMag Pro II, DRKS00007671) determined the diagnostic accuracy of magnetometer-guided sLND in intermediate- and high-risk PCa. Fifty intermediate- or high-risk PCa patients (PSA≥10 ng/ml and/or Gleason score ≥7; median PSA 10.8 ng/ml, IQR 7.4–19.2 ng/ml) were enrolled. After intraprostatic SPIONs injection a day earlier, patients underwent magnetometer-guided sLND and eLND, followed by radical prostatectomy. SLNs were detected in vivo and in ex vivo samples. Diagnostic accuracy of sLND was assessed using eLND as the reference. SLNs were detected in all patients (detection rate 100%), with 447 SLNs (median 9, IQR 6–12) being identified and 966 LNs (median 18, IQR 15-23) being removed. Thirty-six percent (18/50) of patients had LN metastases (median 2, IQR 1–3). Magnetometer-guided sLND had 100% sensitivity, 97.0% specificity, 94.4% positive predictive value, 100% negative predictive value, 0.0% false negative rate, and 3.0% additional diagnostic value (LN metastases only in SLNs outside the eLND template). In vivo, one positive SLN/LN-positive patient was missed, resulting in a sensitivity of 94.4%. In conclusion, this new magnetic sentinel procedure has high accuracy for nodal staging in intermediate- and high-risk PCa. The reliability of intraoperative SLN detection using this magnetometer system requires verification in further multicentric studies.

Keywords

lymphadenectomy; magnetometer; prostate cancer; sentinel lymph node dissection; spion; superparamagnetic iron oxide nanoparticles

Subject

Medicine and Pharmacology, Urology and Nephrology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.