Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Scanning Accuracy of Bracket Features and Slot Base Angle in Different Bracket Materials by Four Intraoral Scanners

Version 1 : Received: 9 December 2020 / Approved: 10 December 2020 / Online: 10 December 2020 (08:17:43 CET)

A peer-reviewed article of this Preprint also exists.

Shin, S.-H.; Yu, H.-S.; Cha, J.-Y.; Kwon, J.-S.; Hwang, C.-J. Scanning Accuracy of Bracket Features and Slot Base Angle in Different Bracket Materials by Four Intraoral Scanners: An In Vitro Study. Materials 2021, 14, 365. Shin, S.-H.; Yu, H.-S.; Cha, J.-Y.; Kwon, J.-S.; Hwang, C.-J. Scanning Accuracy of Bracket Features and Slot Base Angle in Different Bracket Materials by Four Intraoral Scanners: An In Vitro Study. Materials 2021, 14, 365.

Abstract

Accurate expression of bracket prescription is important for successful orthodontic treatment. The aim of this study was to evaluate the accuracy of digital scan images of brackets produced by four different intraoral scanners (IOSs) in terms of the height, position, and angle of the bracket slot when scanning the surface of dental model attached with bracket materials made from different composition of materials. Brackets made from stainless steel, polycrystalline alumina, composite and composite/stainless steel slot were considered, which have been scanned from 4 different IOSs (Primescan, Trios, CS3600 and i500). SEM images were used as references. Each bracket axis was set in the reference scan image, and the axis was set identically by superimposing with the IOS image, and then only the brackets were divided and analyzed. The difference between the manufacturer's nominal torque and bracket slot base angle was 0.39 in SEM, 1.96 in Primescan, 2.04 in Trios, and 5.21 in CS3600 (P <0.001). The parallelism, which is the difference between the upper and lower angles of the slot wall, was 0.55 in SEM, 7.55 in Primescan, 6.74 in Trios3, 6.59 in CS3600, and 24.95 in i500 (p <0.001). This study evaluated the accuracy of the bracket only and it must be admitted that there is some error in recognizing slots through scanning in general

Keywords

intraoral scanner; orthodontic bracket; accuracy; precision; trueness

Subject

Chemistry and Materials Science, Biomaterials

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.